Study guide
7.4 Wood Shingles & Wood Shakes (IBC 1507.8–1507.9): Grades, Slopes, Sheathing, Exposure, Spacing & Fasteners
Louisiana Residential Roofing Contractor Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Louisiana Licensing Law & Act 422 Regulatory Framework
1.1 Act 422 (2025): The Residential Roofing Classification, the $7,500 Threshold & Licensing Requirements 1.2 Act 239 (2025) Roof Permits & Inspections, Permit-Related Violations & Louisiana's Construction Code 1.3 LSLBC Enforcement: Violations, Cease-and-Desist Orders, Civil Fines & Criminal Penalties
2 Chapter 2: Louisiana Business Law, Contracts & Liens
2.1 Louisiana Private Works Act (La. R.S. 9:4801 et seq.): Privileges, Notices of Contract & Termination, and Lien Deadlines 2.2 Residential Roofing Contracts: Required Contents (R.S. 37:2159) & Property-Insurance Claim Rules (R.S. 37:2159.1) 2.3 Contractor Insurance (Liability & Workers' Compensation), the Statutory Employer Rule & Business Records
3 Chapter 3: Roofing Estimating, Plan Reading & Mathematics
3.1 Architectural Roof Plans, Symbols, Dimensions & Structural Pitch Calculations 3.2 Surface Area Calculations, Roofing Squares, Pitch Multipliers & Slope Formulas 3.3 Material Takeoff, Wastage Factors (Hips, Valleys, Rakes), and Jobsite Cost Estimating
4 Chapter 4: Roof Deck Preparation, Substrates & Re-Roofing Codes
4.1 Roof Deck Substrates (Plywood, OSB, Wood Board) & Structural Inspection Criteria 4.2 Reroofing Rules (IBC 1512 / IRC R908): Roof Replacement vs. Roof Recover, the Two-Layer Limit & Tear-Off Triggers 4.3 Deck Fastening, Nail Patterns, Damaged Sheathing Replacement & Clean Substrate Preparation
5 Chapter 5: Hurricane-Resistant Roofing, Wind Codes & FORTIFIED Standards
5.1 Louisiana Wind Speeds, Exposure, Wind-Borne Debris Regions & Roof Uplift Zones (IBC Chapter 16 / ASCE 7) 5.2 High-Wind Underlayment Rules (IBC Table 1507.1.1) & Sealed Roof Deck Options (Taped Seams, Two Layers, Full Self-Adhered) 5.3 IBHS FORTIFIED Roof (2025 Standard), the Louisiana Fortify Homes Program & Louisiana FORTIFIED Incentives 5.4 High-Wind Fastening Protocols: 6-Nail Shingle Patterns, Ring-Shank Nails & ASTM D3161/D7158 Wind Ratings
6 Chapter 6: Asphalt Shingles & Steep-Slope Assemblies
6.1 Asphalt Shingle Types (3-Tab vs. Laminated Architectural), ASTM Classifications & Thermal Behavior 6.2 Underlayment Specifications: Felt vs. Synthetic Underlayments & Self-Adhering High-Temperature Membranes 6.3 Shingle Application Mechanics: Starter Courses, Offsets, Fastener Placement & Wind Sealant Activation 6.4 Valley Construction Assemblies (Open Metal, Woven, Closed-Cut) & Ridge / Hip Cap Installations
7 Chapter 7: Metal, Tile, Slate & Wood Steep-Slope Systems
7.1 Metal Roof Panels & Metal Roof Shingles: Standing Seam, Exposed Fasteners, Minimum Slopes & Thermal Movement 7.2 Concrete & Clay Tile Roof Systems: Battens, Direct-to-Deck, Wind Uplift Resistance & Foam/Mortar Adhesion 7.3 Natural Slate & Synthetic Tile Roofing: Installation Fundamentals, Headlap & Fastening 7.4 Wood Shingles & Wood Shakes (IBC 1507.8–1507.9): Grades, Slopes, Sheathing, Exposure, Spacing & Fasteners
8 Chapter 8: Low-Slope Membranes & Built-Up Roofing (BUR)
8.1 Built-Up Roofing (BUR) Systems: Asphalt vs. Coal Tar Pitch, Organic/Glass Felts & Surfacings 8.2 Polymer-Modified Bitumen Systems: SBS vs. APP, Torched, Hot-Mopped, Cold-Adhesive & Self-Adhered Sheets 8.3 Single-Ply Roofing Membranes: TPO, PVC, and EPDM (Attachment Methods, Seam Welding & Ballast) 8.4 Low-Slope Rigid Insulation, Cover Boards, Vapor Retarders & Thermal Barriers
9 Chapter 9: Flashing, Penetrations & Roof Ventilation
9.1 Edge Metal & Drip Edge: Code Rules (IBC 1507.2.8.3 / IRC R905.2.8.5), FORTIFIED Upgrades & ES-1 Edge Securement 9.2 Step Flashing, Counterflashing, Chimney Crickets & Reglet Details 9.3 Plumbing Vents, Mechanical Exhausts, Skylight Curbs & Roof Penetration Seals 9.4 Attic Ventilation: Net Free Ventilating Area (1/150 vs. 1/300 Rule, IBC 1202.2 / IRC R806), Balanced Airflow & Unvented Attics
10 Chapter 10: Roof Drainage, Maintenance & Emergency Repairs
10.1 Roof Drainage Design: Primary Drains, Secondary Overflow Scuppers & Sizing Calculations 10.2 Gutters, Downspouts, Splash Blocks & Stormwater Runoff Management 10.3 Post-Storm Emergency Tarping, Temporary Shoring, Moisture Assessment & Insurance Scope Documentation
11 Chapter 11: OSHA Safety, Fall Protection & Jobsite Environmental Controls
11.1 OSHA 29 CFR 1926 Subpart M: Fall Protection Systems (Guardrails, Safety Nets, PFAS, Warning Lines & Monitors) 11.2 Ladder & Scaffolding Safety (29 CFR 1926 Subpart L & X, 4:1 Extension Rule, Tie-Off & Pitch) 11.3 PPE, Tool Safety, Hot Kettle/Torch Safety & Hazardous Material Communication (Lead, Asbestos, Silica) 11.4 Heat Illness Prevention & Louisiana High-Humidity Environmental Field Controls
7.4 Wood Shingles & Wood Shakes (IBC 1507.8–1507.9): Grades, Slopes, Sheathing, Exposure, Spacing & Fasteners
Key Takeaways Explain This Topic AI
Wood shingles need a slope of at least 3:12 and wood shakes at least 4:12 (IBC 1507.8.2 and 1507.9.2).
Both may go on solid or spaced sheathing; spaced boards are at least 1 x 4 inches nominal, spaced on centers equal to the weather exposure.
Each shingle or shake gets two corrosion-resistant fasteners penetrating 3/4 inch into the sheathing; Table 1507.8 calls for hot-dipped galvanized or Type 304 stainless, with Type 316 in coastal areas.
Keyways are 1/4 to 3/8 inch for shingles and 3/8 to 5/8 inch for naturally durable shakes, with side laps of at least 1-1/2 inches between courses.
Shakes require an interlayment of ASTM D226 Type I felt; bundles must carry a grading-agency label such as the Cedar Shake and Shingle Bureau (CSSB).
Last updated: September 2026
Why Wood Roofs Are on a Louisiana Exam
Wood roofs are less common in Louisiana than shingles or metal, but they appear on historic homes, custom houses, and porches. Both the IBC and the NRCA steep-slope manual treat them separately, and repairs and reroofs over wood are common on older houses. The exam's open-book references (IBC 1507.8–1507.9, NRCA's wood shake and shingle section, and Atcheson) cover:
- the difference between shingles and shakes ;
- minimum slopes and sheathing;
- maximum exposure tables;
spacing (keyways) and fasteners.
Shingles vs. Shakes
- Feature Wood shingles Wood shakes
- Manufacture Sawn both faces; smooth, tapered Split on at least one face (handsplit), or taper sawn
- Appearance Thin, uniform lines Thick, rustic texture
- Common lengths 16, 18, 24 inches 18, 24 inches
- Minimum slope 3:12 (IBC 1507.8.2) 4:12 (IBC 1507.9.2)
- Interlayment Not required Required : ASTM D226 Type I (IBC 1507.9.5)
Keyway spacing 1/4 to 3/8 inch 3/8 to 5/8 inch (naturally durable shakes and taper-sawn shakes); 1/4 to 3/8 inch for preservative-treated taper-sawn shakes
Grades and Labels
Wood shingles and shakes must be graded by an approved agency and each bundle labeled (IBC 1507.8.9 and 1507.9.10). The Cedar Shake and Shingle Bureau (CSSB) grades most cedar products.
Shingles of naturally durable wood: Grades No. 1, No. 2, or No. 3 (Table 1507.8.5). No. 1 is all heartwood, edge grain, and clear.
Shakes of naturally durable wood: Grade No. 1 . Taper-sawn shakes : No. 1 or No. 2 (Table 1507.9.6).
Preservative-treated taper-sawn shakes of Southern pine are graded under Texas Forest Service rules and treated per AWPA U1.
Deck: Solid or Spaced Sheathing
Wood shingles and shakes may go on solid or spaced sheathing (IBC 1507.8.1 and 1507.9.1):
Spaced boards are at least 1 × 4 inches nominal , spaced on centers equal to the weather exposure so every course's fasteners land on a board.
For shakes, where 1 × 4 spaced sheathing is installed at 10 inches on center , add boards between the sheathing boards.
Solid sheathing is required where the January average daily temperature is 25°F or less or ice may form along the eaves. That is rarely the case in Louisiana, but many designers still use solid sheathing for wind, fire, or FORTIFIED reasons.
Spaced sheathing lets the wood dry from both sides. That helps durability in Louisiana's humidity, where wood that stays wet decays.
Maximum Weather Exposure
Exposure is how much of each course shows to the weather. Longer pieces and steeper roofs allow more exposure.
Wood shingles, naturally durable wood (IBC Table 1507.8.7), in inches:
- Length Grade 3:12 up to 4:12 4:12 and steeper
- 16 in. No. 1 3.75 5
- 16 in. No. 2 3.5 4
- 16 in. No. 3 3 3.5
- 18 in. No. 1 4.25 5.5
- 18 in. No. 2 4 4.5
- 18 in. No. 3 3.5 4
- 24 in. No. 1 5.75 7.5
- 24 in. No. 2 5.5 6.5
- 24 in. No. 3 5 5.5
Wood shakes at 4:12 or steeper (IBC Table 1507.9.8), in inches:
Product 18 in. 24 in.
- Shakes of naturally durable wood, No. 1 7.5 10 (7.5 for 24 in. × 3/8 in. handsplit)
- Taper-sawn shakes, naturally durable wood, No. 1 7.5 10
- Taper-sawn shakes, naturally durable wood, No. 2 5.5 7.5
- Preservative-treated taper-sawn Southern pine, No. 1 7.5 10
- Preservative-treated taper-sawn Southern pine, No. 2 5.5 7.5
Worked example: No. 1 18-inch cedar shingles on a 5:12 roof may be laid at up to 5.5 inches exposure. On a 3.5:12 porch roof, the same shingle is limited to 4.25 inches .
Application Rules (IBC 1507.8.7 and 1507.9.8; Table 1507.8)
Two fasteners per shingle or shake.
Side lap: at least 1-1/2 inches between joints in adjacent courses. For shingles, no two joints in any three adjacent courses may line up.
Keyways (spacing): 1/4 to 3/8 inch for shingles; 3/8 to 5/8 inch for naturally durable shakes; 1/4 to 3/8 inch for preservative-treated taper-sawn shakes. The gaps let the wood swell when wet without buckling.
Fasteners: corrosion resistant, penetrating at least 3/4 inch into the sheathing, or through sheathing less than 1/2 inch thick. Table 1507.8 names hot-dipped galvanized or Type 304 stainless steel , with Type 316 stainless for coastal areas . That matters on the Louisiana coast, where salt air and the extractives in cedar corrode ordinary fasteners.
Placement: put fasteners where the next course will cover them, near each edge. The CSSB and the NRCA manual show the exact distances.
Shake interlayment: shakes are laid with strips of ASTM D226 Type I felt interlaid between courses (IBC 1507.9.5). The felt is placed so it is covered by the next course and does not show at the butt line.
Underlayment: per IBC 1507.1.1. Below 140 mph, D226 Type I or II or D4869 Types I to IV; at 140 mph or more, D226 Type II or D4869 Type IV. Wood shingles laid from 3:12 up to 4:12 get the two-layer application.
Flashing and Valleys (IBC 1507.8.8 and 1507.9.9)
Wall flashing and counterflashing per the manufacturer; metal at least 0.019 inch (No. 26 galvanized) .
Valley flashing extends at least 11 inches from the centerline each way with a splash diverter rib at least 1 inch high , and sections lap at least 4 inches .
For slopes of 3:12 and over , a 36-inch-wide underlayment goes under the valley: one layer of Type I underlayment the full length of the valley, or an ASTM D1970 sheet, in addition to the other underlayment.
Fire Classification
Untreated wood shingles and shakes are usually nonclassified . IBC Table 1505.1 allows nonclassified roofing on Group R-3 and U buildings with at least 6 feet of fire separation. It also allows No. 1 cedar or redwood shakes and No. 1 shingles on buildings of two stories or less and 6,000 square feet or less of projected roof area, with 10 feet of separation on all sides. Fire-retardant-treated shakes and shingles are pressure-treated per AWPA C1, tested for weathering per ASTM D2898, and labeled with their class (IBC 1505.6). Special-purpose wood roofs add a 5/8-inch Type X gypsum layer under the sheathing (IBC 1505.7).
Reroofing Over Wood
The code does not ban recovering wood roofs. Metal panels, metal shingles, and clay or concrete tile may be installed over existing wood shakes (IBC 1512.2.1). Where the new covering over wood shingles or shakes creates a combustible concealed space , the whole existing surface must first be covered with gypsum board, mineral fiber, glass fiber, or another approved material (IBC 1512.3). Most asphalt-shingle manufacturers require wood roofs to be removed first.