Study guide
4.5 Light Pollution Reduction
LEED AP Building Design + Construction BD+C
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & Exam Overview
1.1 Current Exam Facts 1.2 How to Use This Guide
2 Chapter 2: Integrative Process
2.1 Integrative Process Philosophy and Workflow 2.2 Integrative Process Credit (IP) 2.3 Prerequisites and Project Setup 2.4 Certification Levels and Scorecard
3 Chapter 3: Location & Transportation + Surroundings
3.1 LEED for Neighborhood Development Location 3.2 Sensitive Land Protection & High Priority Site 3.3 Surrounding Density and Diverse Uses 3.4 Access to Quality Transit 3.5 Bicycle Facilities, Reduced Parking, Green Vehicles 3.6 Building Surroundings and Joint Use
4 Chapter 4: Sustainable Sites (SS)
4.1 SS Prerequisite: Construction Activity Pollution Prevention 4.2 Site Assessment and Site Development 4.3 Open Space and Rainwater Management 4.4 Heat Island Reduction 4.5 Light Pollution Reduction
5 Chapter 5: Water Efficiency (WE)
5.1 WE Prerequisites 5.2 Outdoor and Indoor Water Use Reduction Credits 5.3 Cooling Tower Water Use, Process Water, and Metering 5.4 Non-Potable and Reclaimed Water Strategies
6 Chapter 6: Energy & Atmosphere (EA)
6.1 EA Prerequisites 6.2 Optimize Energy Performance 6.3 Enhanced Commissioning 6.4 Advanced Energy Metering and Grid Harmonization 6.5 Renewable Energy and Carbon Offsets 6.6 ASHRAE 90.1-2016 Fundamentals
7 Chapter 7: Materials & Resources (MR)
7.1 MR Prerequisites 7.2 Building Life-Cycle Impact Reduction (BLIR) 7.3 Building Product Disclosure and Optimization (BPDO) 7.4 Construction and Demolition Waste Management 7.5 PBT Source Reduction and Furniture Material
8 Chapter 8: Indoor Environmental Quality (EQ)
8.1 EQ Prerequisites 8.2 Enhanced IAQ Strategies and Low-Emitting Materials 8.3 Construction IAQ Management and Assessment 8.4 Thermal Comfort 8.5 Interior Lighting and Daylight 8.6 Quality Views and Acoustic Performance
9 Chapter 9: Innovation, Regional Priority & Project Types
9.1 Innovation Credits 9.2 Regional Priority Credits 9.3 BD+C Project Types and Scope 9.4 Project Registration, Documentation, and Certification Process 9.5 Last-Minute Exam Tips
4.5 Light Pollution Reduction
Key Takeaways Explain This Topic AI
SS Credit: Light Pollution Reduction is worth 1 point and uses the IES TM-15-11 Backlight-Uplight-Glare (BUG) rating system to limit uplight and trespass.
Projects must classify the site into one of five lighting zones, LZ0 (intrinsically dark) through LZ4 (high activity urban), and apply zone-specific BUG limits and curfew rules.
Indoor light pollution from interior fixtures must also be reduced after curfew (10pm in most zones) using shielded fixtures, automated controls, or building automation.
Compliance can be demonstrated using either the BUG method for all exterior luminaires or the IES LM-83 interior trespass calculation method.
Sports fields, signage, and architectural facade lighting have separate, more restrictive curfew and shutoff requirements that often trip up otherwise compliant projects.
Last updated: May 2026
The final SS credit, Light Pollution Reduction , often feels esoteric until candidates see the photographs: poorly designed parking-lot lighting that turns a suburban street into perpetual twilight, or a building facade visible from miles away on Google Earth at 2 a.m. This credit limits four kinds of light pollution: sky glow , light trespass onto adjacent property, glare , and interior light escaping through windows after curfew .
- SS Credit: Light Pollution Reduction (1 point)
- Intent
To increase night sky access, improve nighttime visibility, and reduce the consequences of development for wildlife and people.
Lighting Zone Classification
Before any calculation, the project team classifies the site into one of five lighting zones defined by the IES (Illuminating Engineering Society) and the IDA (International Dark-Sky Association) :
- Zone Description Typical Setting
- LZ0 Intrinsically dark National parks, wilderness, undeveloped rural
- LZ1 Low ambient lighting Rural residential, agricultural
- LZ2 Moderate ambient lighting Suburban neighborhoods, light commercial
- LZ3 Moderately high ambient lighting Urban mixed use, light industrial
- LZ4 High ambient lighting Major city centers, entertainment districts
The zone determines all subsequent BUG and trespass limits. Misclassifying a site into a more permissive zone is one of the most common reasons this credit is denied at review.
The BUG Rating System (IES TM-15-11)
Every outdoor luminaire is assigned three letter-and-number ratings under IES TM-15-11 :
- B (Backlight) — light cast behind the luminaire toward adjacent properties; rated B0 (lowest) to B5 (highest)
- U (Uplight) — light cast above the horizontal; rated U0 to U5
- G (Glare) — light at high angles toward observers; rated G0 to G5
The credit specifies maximum allowable B, U, and G ratings by lighting zone:
- Zone Max U Max B (boundary luminaires) Max G
- LZ0 U0 B0 G0
- LZ1 U1 B1 G1
- LZ2 U2 B2 G2
- LZ3 U3 B3 G3
- LZ4 U4 B4 G4
Exact values are taken from the LEED v4.1 reference guide; the pattern above shows the progressive relaxation as zones become more developed.
Uplight Limit
A stricter independent limit applies: the percentage of total initial fixture lumens emitted above 90° must not exceed a zone-specific cap (e.g., 0% for LZ0, up to 6% for LZ4). U0 fixtures emit virtually zero uplight and are required in LZ0 and LZ1.
Indoor Light Trespass (IES LM-83 Method)
Light escaping interior fixtures through windows after curfew is also regulated. The compliance options are:
- Shielded fixtures that direct interior light away from windows after curfew
- Automated controls that reduce interior lighting power by at least 50% after curfew
- Building automation system that turns off non-essential interior lighting after curfew
- IES LM-83 calculation method demonstrating compliance through whole-building modeling
- Curfew Definition
For LEED purposes the standard curfew is 10:00 p.m. (sometimes the project may use the locally adopted curfew if different). After curfew, both exterior trespass and interior light escape must be reduced.
- Special Restrictions
- Sports field lighting — must be turned off within one hour of the event ending
- Signage — illuminated signs have separate luminance limits and curfew shutoff
Facade and architectural lighting — must be shut off at curfew except in LZ3/LZ4 entertainment districts (which still have limits)
- Emergency and security lighting — generally exempt but must use motion sensors where feasible
- Documentation
- Site plan showing every exterior luminaire with its BUG rating, mounting height, and aiming
- Photometric calculations at the property line showing trespass values
- Lighting zone determination memo with supporting context
- Controls narrative for indoor and outdoor curfew compliance
- Cut sheets for each fixture confirming TM-15-11 BUG values
- Common Exam Traps
The credit is 1 point , not stackable.
BUG ratings come from IES TM-15-11 ; interior trespass uses IES LM-83 . Mixing these up is common.
The five zones are LZ0–LZ4 , with LZ0 the darkest. LZ5 does not exist in the LEED system.
The default curfew is 10pm , not midnight.
Uplight is the single most heavily restricted component — even a small amount of U2 or higher fixtures can fail a project in LZ0 or LZ1.
A vegetated roof or PV array does not exempt a project from this credit if exterior site lighting is present.