Study guide

2.1 OSHA Construction Safety, PPE & Hazard Communication

Maryland Journeyman Plumber Journey Plumber/Gas Fitter

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Maryland Licensing, Code Administration & the Exam

1.1 Maryland Plumbing Regulations & Licensing 1.2 The Journey Plumber/Gas Fitter Exam: Format, References & Open-Book Strategy

2 Chapter 2: Job-Site Safety & OSHA 29 CFR 1926

2.1 OSHA Construction Safety, PPE & Hazard Communication 2.2 Excavation & Trenching Safety (29 CFR 1926 Subpart P) 2.3 Confined Spaces, Ladders, Scaffolds & Hot Work

3 Chapter 3: Materials, Uses & Specifications

3.1 Approved Plumbing Materials, Pipes & Jointing 3.2 Hanger Spacing, Structural Protection & System Testing 3.3 Valves, Fittings, Fitting Selection & Prohibited Connections

4 Chapter 4: Sanitary Drainage & Waste Piping

4.1 Drainage Fixture Units (DFU) & Drain Pipe Sizing 4.2 Building Sewers, Cleanout Clearances & Underground Piping 4.3 Indirect & Special Waste Systems 4.4 Backwater Valves, Sump Pumps & Sewage Ejectors

5 Chapter 5: Venting Systems

5.1 Vent Sizing, Termination & Soil Stacks 5.2 Individual, Branch & Common Vents 5.3 Wet Venting & Circuit Venting 5.4 Air Admittance Valves (AAVs) & Special Venting

6 Chapter 6: Traps, Interceptors & Backwater Valves

6.1 Traps, Trap Seals & Trap Arm Requirements 6.2 Grease, Oil & Special-Waste Interceptors and Separators

7 Chapter 7: Water Supply & Distribution Systems

7.1 Water Supply Sizing & Fixture Unit (WSFU) Method 7.2 Water Heaters & Safety Devices 7.3 Pressure Regulation, Booster Systems & Disinfection 7.4 Water Service Piping, Meters, Valves & System Protection

8 Chapter 8: Backflow Prevention & Cross-Connection Control

8.1 Backflow Prevention & Cross-Connection Control 8.2 Air Gaps, Vacuum Breakers & Their Application Limits 8.3 Double Check & Reduced Pressure Principle (RPZ) Assemblies 8.4 Backflow Assembly Field Testing Procedures & Gauge Use 8.5 Maryland Backflow Program: 32-Hour Course, Certification & Reporting

9 Chapter 9: Fuel Gas Fundamentals, Materials & Pipe Sizing

9.1 Fuel Gas Properties, Heating Values & IFGC Scope 9.2 Fuel Gas Pipe Sizing & Materials 9.3 Approved Gas Piping Materials, CSST & Bonding 9.4 Gas Pipe Sizing Tables: Longest-Length & Branch-Length Methods 9.5 LP-Gas Systems, NFPA 58 & Propane-Specific Rules

10 Chapter 10: Gas Piping Installation, Testing & Purging

10.1 Gas Piping Installation, Testing & Purging 10.2 Gas Piping Support, Protection, Prohibited Locations & Concealed Piping 10.3 Shutoff Valves, Drips, Unions, Sediment Traps & Appliance Connectors 10.4 Gas Meters, Regulators, Pressure Levels & Overpressure Protection 10.5 Gas Leak Detection, Odorization & Emergency Response

11 Chapter 11: Gas Appliance Venting & Combustion Air

11.1 Gas Appliance Venting & Combustion Air 11.2 Appliance Categories I-IV, Vent Materials & Vent Connectors 11.3 Chimney & Vent Sizing Tables (Type B, Masonry & Common Venting) 11.4 Vent Termination, Clearances & Direct-Vent Systems 11.5 Combustion Air: Indoor & Outdoor Methods and Opening Sizing

12 Chapter 12: Gas Appliance Installation & Service

12.1 Gas Water Heaters, Furnaces & Boilers: Installation Rules 12.2 Appliance Clearances to Combustibles, Access & Location Limits 12.3 Gas Appliance Troubleshooting, Combustion Analysis & CO Safety

13 Chapter 13: Plumbing Fixtures, Fittings & Appliances

13.1 Fixture Clearances, Accessibility & Installation 13.2 Water Conservation Standards & Flow Rates 13.3 Commercial & Specialty Fixture Requirements

14 Chapter 14: Plumbing Mathematics

14.1 Plumbing Math I: Areas, Volumes, Capacities & Water Weight 14.2 Plumbing Math II: Offsets, Travel, Grade & Pipe Layout 14.3 Plumbing Math III: Gas Math, Meter Readings, BTU & Pressure Conversions

2.1 OSHA Construction Safety, PPE & Hazard Communication

Key Takeaways Explain This Topic AI

29 CFR 1926.95(d)(1) requires the employer to provide PPE at no cost to employees; the main exceptions are non-specialty safety-toe footwear and non-specialty prescription safety eyewear permitted to be worn off site.

Subpart E assigns foot protection to 1926.96, head protection to 1926.100, hearing to 1926.101, eye and face to 1926.102, and respiratory protection to 1926.103; there is no 1926.98 because it is reserved.

Under 29 CFR 1904.39 a work-related fatality must be reported to OSHA within 8 hours, and an in-patient hospitalization, amputation, or loss of an eye within 24 hours.

The OSHA respirable crystalline silica PEL is 50 micrograms per cubic meter as an 8-hour TWA with a 25 microgram action level (1926.1153); lead is 50 micrograms with a 30 microgram action level (1926.62).

Fall protection in general construction is triggered at 6 feet under 1926.501(b)(1), but on a scaffold the trigger is more than 10 feet under 1926.451(g)(1).

Last updated: July 2026

2.1 OSHA Construction Safety, PPE & Hazard Communication

Quick Answer: 29 CFR Part 1926 - the OSHA construction standards - is one of only five references you may bring into the PSI testing room, and it feeds the 8-item "Plumbing Fundamentals and Safety" domain. Memorize three numbers first: personal protective equipment must be supplied by the employer at no cost to the employee (1926.95(d)(1)); fall protection in construction is triggered at 6 feet (1926.501(b)(1)); and a work-related fatality must be reported to OSHA within 8 hours , while an in-patient hospitalization, amputation, or loss of an eye must be reported within 24 hours (29 CFR 1904.39).

Why Part 1926 Is on a Plumbing Exam

29 CFR Part 1926 , "Safety and Health Regulations for Construction," applies to construction work - construction, alteration, and repair, including painting and decorating. Part 1910 covers general industry. When you are roughing in a building, replacing a water service, or repiping a boiler room, you are working under Part 1926. Because 1926 is an open-book reference on this exam, the Board expects you to navigate it, not recite it. Learn the subpart letters and the section numbers, and most safety questions become a 30-second lookup.

Three general-duty provisions drive everything else:

1926.20(b)(1) - the employer must initiate and maintain the programs necessary to comply with Part 1926.

1926.20(b)(2) - those programs must provide for frequent and regular inspections of job sites, materials, and equipment by competent persons designated by the employer.

1926.21(b)(2) - the employer must instruct each employee in the recognition and avoidance of unsafe conditions .

A competent person is someone capable of identifying existing and predictable hazards in the surroundings or working conditions that are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them . The authority half of that definition is what exam writers test: a foreman who can spot a hazard but cannot stop the work is not a competent person.

Subpart E - Personal Protective and Life Saving Equipment

  • Section Title Typical plumbing trigger
  • 1926.95 Criteria for personal protective equipment Umbrella rule plus the employer-payment rule
  • 1926.96 Occupational foot protection Handling pipe and fittings, jackhammer work
  • 1926.97 Electrical protective equipment Work near live panels, bonding and grounding
  • 1926.98 [Reserved] Nothing - see the Exam Trap below
  • 1926.100 Head protection Overhead rough-in, trench and crane zones
  • 1926.101 Hearing protection Hammer drills, concrete saws, jackhammers
  • 1926.102 Eye and face protection Soldering, brazing, cutting, chemical drain work
  • 1926.103 Respiratory protection (identical to 1910.134) Silica dust, solvent cement vapors, sewer work
  • 1926.104 Safety belts, lifelines, and lanyards Roof vent terminations
  • 1926.105 Safety nets High steel and open deck work
  • 1926.106 Working over or near water Marine and dock service piping
  • Who pays for PPE

1926.95(d)(1) states that protective equipment used to comply with Part 1926 "shall be provided by the employer at no cost to employees." The exceptions are narrow:

Non-specialty safety-toe protective footwear and non-specialty prescription safety eyewear , provided the employer permits the item to be worn off the job site (1926.95(d)(2)).

Shoes or boots with built-in metatarsal protection , when the employer provides separate metatarsal guards and the employee chooses the built-in version instead (1926.95(d)(3)).

Everyday clothing and ordinary weather-related gear (1926.95(d)(4)).

Replacement PPE is the employer's cost except when the employee has lost or intentionally damaged it (1926.95(d)(5)).

Filter shades for torch work

Table E-1 in 1926.102 gives guide shade numbers you can look up in seconds:

  • Operation Shade number
  • Soldering 2
  • Torch brazing 3 or 4
  • Light cutting, up to 1 inch 3 or 4
  • Medium cutting, 1 inch to 6 inches 4 or 5
  • Gas welding (light), up to 1/8 inch 4 or 5

Exam Trap: Fall protection triggers are not the same number everywhere. General construction work triggers at 6 feet (1926.501(b)(1)), and 6 feet also governs holes (1926.501(b)(4)) and the edge of an excavation, well, pit, or shaft (1926.501(b)(7)). But on a scaffold the trigger is more than 10 feet (1926.451(g)(1)). Candidates who memorize "6 feet, always" miss the scaffold question; candidates who memorize "10 feet" miss every trench-edge question. Note also that there is no Sec. 1926.98 - it is reserved, so flipping to it burns open-book time.