Study guide
14.3 Plumbing Math III: Gas Math, Meter Readings, BTU & Pressure Conversions
Maryland Journeyman Plumber Journey Plumber/Gas Fitter
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Maryland Licensing, Code Administration & the Exam
1.1 Maryland Plumbing Regulations & Licensing 1.2 The Journey Plumber/Gas Fitter Exam: Format, References & Open-Book Strategy
2 Chapter 2: Job-Site Safety & OSHA 29 CFR 1926
2.1 OSHA Construction Safety, PPE & Hazard Communication 2.2 Excavation & Trenching Safety (29 CFR 1926 Subpart P) 2.3 Confined Spaces, Ladders, Scaffolds & Hot Work
3 Chapter 3: Materials, Uses & Specifications
3.1 Approved Plumbing Materials, Pipes & Jointing 3.2 Hanger Spacing, Structural Protection & System Testing 3.3 Valves, Fittings, Fitting Selection & Prohibited Connections
4 Chapter 4: Sanitary Drainage & Waste Piping
4.1 Drainage Fixture Units (DFU) & Drain Pipe Sizing 4.2 Building Sewers, Cleanout Clearances & Underground Piping 4.3 Indirect & Special Waste Systems 4.4 Backwater Valves, Sump Pumps & Sewage Ejectors
5 Chapter 5: Venting Systems
5.1 Vent Sizing, Termination & Soil Stacks 5.2 Individual, Branch & Common Vents 5.3 Wet Venting & Circuit Venting 5.4 Air Admittance Valves (AAVs) & Special Venting
6 Chapter 6: Traps, Interceptors & Backwater Valves
6.1 Traps, Trap Seals & Trap Arm Requirements 6.2 Grease, Oil & Special-Waste Interceptors and Separators
7 Chapter 7: Water Supply & Distribution Systems
7.1 Water Supply Sizing & Fixture Unit (WSFU) Method 7.2 Water Heaters & Safety Devices 7.3 Pressure Regulation, Booster Systems & Disinfection 7.4 Water Service Piping, Meters, Valves & System Protection
8 Chapter 8: Backflow Prevention & Cross-Connection Control
8.1 Backflow Prevention & Cross-Connection Control 8.2 Air Gaps, Vacuum Breakers & Their Application Limits 8.3 Double Check & Reduced Pressure Principle (RPZ) Assemblies 8.4 Backflow Assembly Field Testing Procedures & Gauge Use 8.5 Maryland Backflow Program: 32-Hour Course, Certification & Reporting
9 Chapter 9: Fuel Gas Fundamentals, Materials & Pipe Sizing
9.1 Fuel Gas Properties, Heating Values & IFGC Scope 9.2 Fuel Gas Pipe Sizing & Materials 9.3 Approved Gas Piping Materials, CSST & Bonding 9.4 Gas Pipe Sizing Tables: Longest-Length & Branch-Length Methods 9.5 LP-Gas Systems, NFPA 58 & Propane-Specific Rules
10 Chapter 10: Gas Piping Installation, Testing & Purging
10.1 Gas Piping Installation, Testing & Purging 10.2 Gas Piping Support, Protection, Prohibited Locations & Concealed Piping 10.3 Shutoff Valves, Drips, Unions, Sediment Traps & Appliance Connectors 10.4 Gas Meters, Regulators, Pressure Levels & Overpressure Protection 10.5 Gas Leak Detection, Odorization & Emergency Response
11 Chapter 11: Gas Appliance Venting & Combustion Air
11.1 Gas Appliance Venting & Combustion Air 11.2 Appliance Categories I-IV, Vent Materials & Vent Connectors 11.3 Chimney & Vent Sizing Tables (Type B, Masonry & Common Venting) 11.4 Vent Termination, Clearances & Direct-Vent Systems 11.5 Combustion Air: Indoor & Outdoor Methods and Opening Sizing
12 Chapter 12: Gas Appliance Installation & Service
12.1 Gas Water Heaters, Furnaces & Boilers: Installation Rules 12.2 Appliance Clearances to Combustibles, Access & Location Limits 12.3 Gas Appliance Troubleshooting, Combustion Analysis & CO Safety
13 Chapter 13: Plumbing Fixtures, Fittings & Appliances
13.1 Fixture Clearances, Accessibility & Installation 13.2 Water Conservation Standards & Flow Rates 13.3 Commercial & Specialty Fixture Requirements
14 Chapter 14: Plumbing Mathematics
14.1 Plumbing Math I: Areas, Volumes, Capacities & Water Weight 14.2 Plumbing Math II: Offsets, Travel, Grade & Pipe Layout 14.3 Plumbing Math III: Gas Math, Meter Readings, BTU & Pressure Conversions
14.3 Plumbing Math III: Gas Math, Meter Readings, BTU & Pressure Conversions
Key Takeaways Explain This Topic AI
Clocking formula: cfh = (3,600 × dial size) ÷ seconds per revolution, so a 1-cubic-foot dial turning once in 84 seconds equals 3,600 ÷ 84 = 43 cfh.
Convert appliance input to volume by dividing BTU/h by 1,000 for natural gas and by 2,500 for propane; a 150,000 BTU/h propane furnace demands 60 cfh.
One psi equals 27.7 inches of water column, 2.31 feet of head and 2.036 inches of mercury; 2.31 ft × 12 = 27.7 in, the same column measured two ways.
IFGC 2018 Section 406.4.1 sets a minimum gas test pressure of 3 psig, which equals 83.1 inches of water column and is therefore beyond any manometer's range.
Water-heater recovery in GPH = (input BTU/h × efficiency) ÷ (8.33 × temperature rise); 40,000 BTU/h at 75 percent with a 90°F rise gives 40.0 GPH.
Last updated: July 2026
14.3 Plumbing Math III: Gas Math, Meter Readings, BTU & Pressure Conversions
Quick Answer: cfh = (3,600 × dial size) ÷ seconds per revolution. The official PSI sample question — a one-cubic-foot hand that revolves once in 84 seconds — gives 3,600 ÷ 84 = 42.86, which rounds to 43 cubic feet per hour .
Gas Appliances and Piping is 40 of the 100 scored questions, so the gas-flavored arithmetic inside the Plumbing Mathematics domain is worth far more than its 7-question share suggests. All of it rests on three ideas: a gas meter is a volume counter you can time with a stopwatch, gas volume converts to heat through a heating value , and fuel-gas pressure is measured in a unit that must be converted before it means anything in psi.
Clocking a Diaphragm Gas Meter
A residential diaphragm meter carries one or two small test dials (also called proving dials), each labeled with the volume that one full revolution represents — typically 1/2, 1, 2, 5 or 10 cubic feet . To clock an appliance, shut off every other gas appliance including standing pilots, fire the appliance under test at high fire until it reaches steady state, then time one complete revolution of the test hand.
cfh = (3,600 × dial size in cubic feet) ÷ time in seconds
The 3,600 is nothing more than the number of seconds in an hour, so the formula reads "cubic feet per second, scaled up to an hour."
Worked Example 1 — The Official PSI Sample Question
"The one-cubic-foot hand revolves once in 84 seconds. Gas is passing through the meter at how many cubic feet per hour?"
- (3,600 × 1) ÷ 84 = 3,600 ÷ 84 = 42.857
- Rounded: 43 cubic feet per hour
- Worked Example 2 — The Same Timing on a 2-Cubic-Foot Dial
You timed the 2 ft³ hand because the 1 ft³ hand was spinning too fast to read, and it took the same 84 seconds:
(3,600 × 2) ÷ 84 = 7,200 ÷ 84 = 85.7 cfh
Twice the volume per revolution in the same time means exactly twice the flow. Dropping the dial-size multiplier is the most common arithmetic error on this problem type.
Worked Example 3 — A 1/2-Cubic-Foot Dial
A furnace turns the 1/2 ft³ hand once in 22 seconds: