11.4 Air Admittance Valves (AAVs) & Michigan Part 7 Restrictions

Michigan Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Michigan Plumbing Law, Administration & Licensing

1.1 Michigan Skilled Trades Regulation Act (PA 407 Article 11) & Licensing Hierarchy 1.2 Permits, Applications, Inspections & Code Enforcement 1.3 Essential Plumbing Code Definitions & Terminology

2 Chapter 2: General Regulations & Structural Safety

2.1 Piping Protection, Trenching, Bedding & Backfill 2.2 Structural Safety: Boring, Notching & Cutting of Structural Members 2.3 Pipe Hangers, Supports & Spacing Requirements 2.4 Michigan Frost Protection & Underground Piping Depths

3 Chapter 3: Fixtures, Faucets & Fixture Fittings

3.1 Minimum Plumbing Fixtures, Occupancy Calculations & ADA Accessibility 3.2 Installation of Fixtures: Setting, Clearances, Connections & Access 3.3 Water Closets, Urinals & Flushing Devices 3.4 Showers, Bathtubs & Scald Prevention Standards 3.5 Sinks, Lavatories, Drinking Fountains & Emergency Fixtures

4 Chapter 4: Water Heaters & Hot Water Safety

4.1 Water Heater Sizing, Location, Clearances & Combustion Air 4.2 Temperature & Pressure (T&P) Relief Valves & Discharge Piping 4.3 Thermal Expansion Control, Safety Pans & Drain Terminations

5 Chapter 5: Water Supply Sizing & Distribution

5.1 Water Service Sizing & Water Supply Fixture Units (WSFU) 5.2 Water Distribution Pipe Sizing, Velocity & Pressure Drop 5.3 Potable Water Piping Materials, Joining Methods & Valves 5.4 Potable Water System Testing, Disinfection & Commissioning 5.5 Health Care Plumbing: Hospitals, Labs & Medical Offices (MPC 609)

6 Chapter 6: Cross-Connection Control & Backflow Prevention

6.1 Backflow Principles: Backpressure, Backsiphonage & Hazard Levels 6.2 Backflow Prevention Assemblies & Devices 6.3 Installation, Testing & Certification of Backflow Preventers

7 Chapter 7: Sanitary Drainage: Sizing & System Layout

7.1 Drainage Fixture Units (DFU) & Building Drain / Sewer Sizing 7.2 Minimum Slopes, Flow Velocity & Horizontal Drainage Piping 7.3 Soil & Waste Stacks, Stack Offsets & Base Fittings 7.4 Sump Pumps, Sewage Ejectors & Macerating Toilet Systems

8 Chapter 8: Sanitary Drainage: Cleanouts, Materials & Testing

8.1 Cleanout Sizing, Location, Clearances & Direction of Flow 8.2 Drainage Pipe Materials, Drainage Fittings & Prohibited Fittings 8.3 Drainage System Testing: Water, Air & Final Inspection Tests

9 Chapter 9: Indirect & Special Waste Systems

9.1 Air Gaps vs. Air Breaks: Code Definitions, Sizing & Applications 9.2 Food Handling Establishments, Commercial Dishwashers & Beverage Lines 9.3 Chemical, Corrosive & Special Laboratory Waste Systems

10 Chapter 10: Vents & Venting: Principles & Sizing

10.1 Venting Fundamentals: Atmospheric Pressure & Trap Seal Protection 10.2 Vent Stacks, Stack Vents & Individual Vent Sizing Rules 10.3 Vent Terminations, Roof Penetrations & Michigan Frost Closure

11 Chapter 11: Advanced Venting Systems

11.1 Wet Venting: Horizontal & Vertical Rules and Pipe Sizing 11.2 Circuit & Loop Venting: Sizing, Fixture Limits & Relief Vents 11.3 Combination Waste & Vent Systems (CWV) 11.4 Air Admittance Valves (AAVs) & Michigan Part 7 Restrictions

12 Chapter 12: Traps, Interceptors & Separators

12.1 Fixture Trap Design, Trap Seal Depth & Maximum Trap-to-Vent Distance 12.2 Prohibited Traps, Double Trapping & Trap Seal Primer Mechanisms 12.3 Grease Interceptors: Hydromechanical (HGI) vs. Gravity (GGI) 12.4 Oil Separators, Sand Interceptors & Flammable Liquid Separation

13 Chapter 13: Storm Drainage Systems

13.1 Roof Drainage Sizing & Michigan Rainfall Rates 13.2 Primary vs. Secondary (Emergency) Overflow Roof Drainage 13.3 Conductors, Leaders, Building Storm Drains & Sump Systems

14 Chapter 14: Gas Piping Systems: Fuel Gas & Medical Gas

14.1 Fuel Gas Sizing Methods: Longest Length & Branch Sizing 14.2 Fuel Gas Piping Materials, Fittings, Joining & Hangers 14.3 Appliance Shutoffs, Regulators, Sediment Traps & Pressure Testing 14.4 Medical Gas, Vacuum & Nonmedical Oxygen Piping (MPC Chapter 12)

15 Chapter 15: Isometric Drawings & Blueprint Reading

15.1 Isometric Drawing Fundamentals: 30-Degree Axes & Fitting Symbols 15.2 Reading & Interpreting DWV Isometric Riser Diagrams 15.3 Reading & Interpreting Water Supply & Gas Isometric Layouts 15.4 Identifying Code Violations & Layout Errors in Isometric Drawings

16 Chapter 16: Plumbing Math, Calculations & Practical Skills

16.1 45-Degree Offsets, Rolling Offsets & Fitting Allowances 16.2 Grade, Fall, Percentage of Slope & Invert Elevation Calculations 16.3 Volume, Capacity, Head Pressure & Flow Rate Calculations 16.4 Michigan Practical Examination: Soldering, Brazing, Assembly & Safety

11.4 Air Admittance Valves (AAVs) & Michigan Part 7 Restrictions

Key Takeaways Explain This Topic AI

Air Admittance Valves (AAVs) are mechanical one-way pressure-relief devices certified under ASSE 1051 (individual/branch) and ASSE 1050 (stacks) that open on negative pressure and seal by gravity under static or positive pressure.

MPC Section 918.7 requires that within each plumbing system, not less than one stack vent or vent stack extend outdoors to the open air, so a building cannot be vented exclusively with air admittance valves.

AAVs are strictly prohibited on chemical waste systems, sumps, sewage ejector basins, grease interceptor discharge lines, and exterior locations subject to freezing temperatures.

Individual and branch-type AAVs must be located not less than 4 inches above the horizontal branch drain or fixture drain being vented, not less than 6 inches above insulation materials, and above the trap weir of the fixture served.

AAVs must be installed in a location that allows air to enter the valve and be rated for the temperature range of their listing; MPC 918.8 prohibits them in supply or return air plenums and prohibits their use to vent sumps or tanks of any type.

Last updated: September 2026

11.4 Air Admittance Valves (AAVs) & Michigan Part 7 Restrictions

Exam Focus: Air Admittance Valves are regulated by MPC Section 918 , which Michigan adopts without a Part 7 amendment. The Michigan Journey Plumber licensing examination tests MPC 918.7 (every plumbing system must still have at least one stack vent or vent stack extending outdoors to the open air), the physical installation clearances in MPC 918.3.1 and 918.4 ( 4 inches above the horizontal branch drain, 6 inches above insulation materials, above the trap weir, accessible with air able to enter the valve ), and the prohibitions in MPC 918.8 , including the ban on using an AAV to vent a sump or tank of any type.

1. Operating Mechanics & Product Standards (ASSE 1051 & 1050)

An Air Admittance Valve (AAV) is a specialized mechanical valve designed to provide venting without requiring an individual vent pipe to penetrate the roof envelope. AAVs are precision-manufactured devices governed by strict national standards: +-----------------------------------------------------------------------------+

  • | AAV MECHANICAL OPERATING MODES |
  • +-----------------------------------------------------------------------------+
  • | |
  • | [1] STATIC (RESTING) STATE: |
  • | - No water flowing in drain. |
  • | - Internal atmospheric pressure equals room pressure. |
  • | - Gravity and light spring hold elastomeric diaphragm tightly seated. |
  • | - SEALS GAS-TIGHT: Prevents sewer gas from entering building. |
  • | |
  • | [2] DYNAMIC (OPENING) STATE: |
  • | - Fixture drains; falling water creates NEGATIVE PRESSURE (vacuum). |
  • | - Atmospheric pressure in room lifts the diaphragm off its seat. |
  • | - ROOM AIR ENTERS DRAIN: Satisfies vacuum, protects trap seal. |
  • | |
  • | [3] POSITIVE BACKPRESSURE STATE: |
  • | - Downstream blockage or surging effluent creates POSITIVE PRESSURE. |
  • | - Positive pressure pushes UP against the diaphragm. |
  • | - VALVE SLAMS SHUT: Prevents sewer gas/waste backup through valve. |
  • +-----------------------------------------------------------------------------+
  • The Fundamental Limitation of AAVs

Exam Core Concept: An Air Admittance Valve is a ONE-WAY VALVE . It can ONLY relieve negative pressure (vacuum) . It CANNOT relieve positive pressure (backpressure) . It can breathe in , but it cannot breathe out . Understanding this physical limitation is essential to understanding why model codes and Michigan state rules place rigorous constraints on where and how AAVs are installed.

Governing Standards

ASSE 1051: Standard for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems. Rated for individual fixtures and horizontal branch lines up to specified DFU ratings.

ASSE 1050: Standard for Stack-Mounted Air Admittance Valves for Sanitary Drainage Systems. Rated for larger volume air admittance on vertical soil and waste stacks.

2. The Open-Vent Requirement: MPC 918.7

Michigan's Part 7 rules contain no amendment to MPC Section 918 , so the air admittance valve rules a Michigan candidate must know are the adopted 2021 IPC provisions themselves. The one that governs whole-building design is 918.7 (Vent required) : +-----------------------------------------------------------------------------+

  • | MANDATORY OPEN VENT RULE: MPC SECTION 918.7 |
  • +-----------------------------------------------------------------------------+
  • | |
  • | "Within each plumbing system, not less than one stack vent or vent stack |
  • | shall extend outdoors to the open air." |
  • | |
  • | In Michigan that terminal must also satisfy R 408.30754a (3-inch minimum |
  • | diameter through the roof) and the amended 903.1 (12 inches above roof). |
  • | |
  • | CRITICAL STATUTORY IMPLICATION: |
  • | - A contractor CANNOT construct a building vented EXCLUSIVELY with AAVs! |
  • | - Every building MUST have at least ONE full-size conventional vent pipe |
  • | open to the outdoor atmosphere. |
  • +-----------------------------------------------------------------------------+
  • Why the Code Still Requires One Open Vent

Municipal sanitary sewer systems are dynamic environments subject to massive pressure fluctuations caused by storm surges, municipal main flushing, and atmospheric barometric changes. In addition, anaerobic digestion of organic matter produces methane and hydrogen sulfide gases that naturally expand. If a building were plumbed entirely with AAVs, all valves would remain sealed shut under positive pressure. Expanding sewer gases would have no outdoor escape path, forcing their way past water closet and P-trap water seals, bubbling into living spaces, and creating an imminent health hazard.

3. Strictly Prohibited AAV Applications (MPC 918.8)

MPC Section 918.8 (Prohibited installations) states that air admittance valves shall not be installed in supply or return air plenums, and shall not be used to vent sumps or tanks of any type . The additional restrictions below follow from the ASSE 1050/1051 listings and from the sections of the code that require an open atmospheric vent: +-----------------------------------------------------------------------------+

  • | STRICTLY PROHIBITED AAV APPLICATIONS |
  • +-----------------------------------------------------------------------------+
  • | |
  • | [1] SEWAGE EJECTOR BASINS & SUMPS: |
  • | - PROHIBITED: AAV cannot vent a sealed sewage ejector pit. |
  • | - Reason: When ejector pump runs, incoming waste displaces air |
  • | (positive pressure). An AAV stays closed, creating an air lock. |
  • | |
  • | [2] CHEMICAL, ACID & LABORATORY DRAINAGE: |
  • | - PROHIBITED: Toxic and corrosive fumes deteriorate the rubber seals. |
  • | |
  • | [3] GREASE INTERCEPTORS: |
  • | - PROHIBITED: Grease aerosols and volatile fatty acids foul the seat. |
  • | |
  • | [4] OUTDOOR & FREEZING LOCATIONS (< 32°F / 0°C): |
  • | - PROHIBITED: Condensation freezes the diaphragm to the valve body. |
  • | |
  • | [5] AIR SUPPLY OR RETURN DUCTS / PLENUMS: |
  • | - PROHIBITED: Unless specifically tested and listed for plenum use. |
  • +-----------------------------------------------------------------------------+

Exam Trap Alert: A classic Michigan licensing question asks: "Can an Air Admittance Valve be installed as the vent for a basement sewage ejector pit?" The answer is ABSOLUTELY NOT . Sewage ejectors require a dedicated, non-mechanical open vent pipe (minimum 2 inches) extending through the roof to allow the rapid exhaust of displaced positive air during pump cycling.

4. Installation Clearances & Mounting Standards (MPC Sections 918.3.1, 918.4 and 918.5)

The code establishes exact dimensional and accessibility requirements for every AAV installation: +-----------------------------------------------------------------------------+

  • | MANDATORY AAV INSTALLATION CLEARANCES |
  • +-----------------------------------------------------------------------------+
  • | |
  • | [1] ELEVATION ABOVE HORIZONTAL BRANCH: |
  • | - Minimum of 4 INCHES (102 mm) vertically above the horizontal branch |
  • | drain or fixture drain being served. |
  • | |
  • | [2] ELEVATION ABOVE THE TRAP WEIR: |
  • | - The valve must be located above the trap weir of the fixture served, |
  • | and manufacturer listings commonly require it above the fixture |
  • | flood level rim as well - follow the listing on the valve. |
  • | |
  • | [3] ELEVATION ABOVE INSULATION: |
  • | - Minimum of 6 INCHES (152 mm) above insulation materials |
  • | (MPC 918.3.1). |
  • | |
  • | [4] ACCESSIBILITY & AIR CIRCULATION: |
  • | - MUST be installed in an accessible location with free air flow. |
  • | - Cannot be entombed inside a sealed drywall wall without an access |
  • | door or louvered grill! |
  • | |
  • | [5] TEMPERATURE RATING: |
  • | - The valve must be rated for the temperature range in its ASSE 1051 |
  • | or ASSE 1050 listing; standard valves are not listed for service |
  • | below freezing, which is why exterior use is not permitted. |

+-----------------------------------------------------------------------------+ AAV INSTALLATION CLEARANCE DIAGRAM

UNDER-SINK / CABINET INSTALLATION: ATTIC INSTALLATION:

  • [AAV]
  • ^
  • | Min. 6" Clearance
  • v
  • [AAV] ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  • ^ [BLOWN-IN ATTIC INSULATION]
  • | Min. 6" above rim =================================
  • v [Ceiling Drywall]
  • Flood Level Rim |
  • +--------------------+ |
  • | KITCHEN SINK | |
  • +--------------------+ |
  • | |
  • v |
  • +-----+ |
  • | |========\ |
  • +-----+ \ |
  • (P-Trap) v |
  • ==========================+====== |
  • ^ | |
  • | Min. 4" Rise +-------------------------+
  • v | (Vertical Vent Riser)
  • [Horizontal Branch] v
  • The Hydraulic Logic of the Clearances

The 4-Inch Branch Clearance (MPC 918.3.1): Mounting the AAV at least 4 inches above the horizontal branch ensures that normal waste flow along the bottom of the drain pipe cannot splash up into the valve chamber. If waste splashing coats the elastomeric diaphragm, grease and solids will dry on the seal, preventing it from closing airtight.

Mounting Above the Trap Weir and Flood Rim (MPC 918.3.1 and manufacturer listing): If a sink or branch drain suffers a complete downstream blockage, sewage backing up into the pipe will rise to the fixture's flood level rim. If the AAV were mounted lower than 6 inches above the rim, raw sewage would submerge the valve, fouling the mechanical mechanism and leaking out into cabinetry.

The 6-Inch Insulation Clearance (MPC 918.3.1): In modern energy-efficient Michigan homes, blown-in cellulose or fiberglass attic insulation can be 14 to 18 inches deep. An AAV terminating inside or resting directly on the insulation will draw loose fibers and dust into the valve seat during negative pressure cycles, causing the valve to stick open and leak sewer gas into the attic.

Accessibility and Free Air Circulation (MPC 918.5): AAVs must be installed in a location that can be inspected, tested, and replaced. An AAV located inside a wall cavity must be provided with an access panel having a minimum free-air ventilation opening (typically a louvered faceplate) sized according to the manufacturer's listing.

5. Master Summary Table of AAV Rules

  • Design Feature Code Specification Code Reference
  • Product Standards ASSE 1051 (individual/branch) & ASSE 1050 (stack) MPC 918.1

Open Vent Still Required Within each plumbing system, not less than one stack vent or vent stack must extend outdoors to the open air MPC 918.7

Min. Height Above Branch Minimum 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented MPC 918.3.1

Position Relative to Trap Above the trap weir of the fixture served; manufacturer listings commonly add "above the flood level rim" MPC 918.3.1 and product listing

  • Min. Height Above Insulation Minimum 6 inches (152 mm) above insulation materials MPC 918.3.1
  • Prohibited Applications Supply or return air plenums; venting sumps or tanks of any type MPC 918.8

Temperature Rating As listed to ASSE 1051 / ASSE 1050; not listed for sub-freezing exterior service ASSE 1051 / ASSE 1050

  • Access Requirement Must be accessible with free air circulation (no sealed drywall) MPC 918.5
  • 6. Realistic Exam Application Scenarios
  • Scenario A: Residential Kitchen Island Remodel in Grand Rapids

Exam Scenario: A homeowner in Grand Rapids is remodeling a kitchen and installing a center island containing a single-compartment prep sink (1-1/2 DFU). The home was built with a conventional 3-inch stack vent penetrating the roof above the main second-floor bathroom. The remodeling plumber decides to install an ASSE 1051-listed AAV inside the island cabinet to vent the prep sink.

The plumber mounts the AAV 5 inches above the horizontal fixture drain and 7 inches above the sink flood level rim inside the vanity cabinet. Is this installation compliant with the Michigan Plumbing Code?

Code Analysis:

Open Vent Compliance: The home already has an existing 3-inch stack vent extending through the roof, satisfying MPC 918.7 as well as Michigan's 3-inch frost closure rule (R 408.30754a).

Fixture Compatibility: A prep sink is an approved fixture under MPC 918.1, and an ASSE 1051 valve is the correct listing for an individual fixture vent.

Clearance Compliance:

The 5-inch elevation above the horizontal fixture drain exceeds the 4-inch minimum in MPC 918.3.1.

Mounting 7 inches above the sink flood level rim places the valve well above the trap weir, satisfying MPC 918.3.1 and the manufacturer's listing.

Accessibility: The valve is housed within the under-sink cabinet, which is an accessible space with sufficient free air volume.

Conclusion: The installation is 100% compliant and will be approved by the local plumbing inspector.

Scenario B: Basement Sewage Ejector Venting Violation

Exam Scenario: An apprentice plumber is completing a basement bathroom rough-in in a newly constructed home in Warren, Michigan. The basement contains a water closet, shower, and lavatory that drain by gravity into a sealed, gas-tight polyethylene sewage ejector pit. Because running a 2-inch vent pipe up through the two upper finished floors to the roof is difficult, the apprentice installs an ASSE 1050-listed stack AAV on the 2-inch vent connection of the ejector pit lid, terminating the valve 12 inches above the lid in the unfinished basement.

Will the Michigan state plumbing inspector approve this installation?

Code Analysis:

Code Violation: The installation is an immediate failure under MPC Section 918.8 , which states that air admittance valves shall not be used to vent sumps or tanks of any type.

Mechanical Failure Analysis: An AAV is a one-way valve designed solely to admit air. A sewage ejector basin operates by gravity inflow and positive displacement. As wastewater rushes into the sealed basin from the toilet or shower, it displaces air inside the tank. The AAV cannot release this positive air pressure because the valve disc is forced shut by upward pressure. As air pressure builds inside the tank, incoming wastewater will gurgle and stall, eventually blowing past the toilet and shower trap seals.

Mandated Correction: The AAV must be removed immediately. The ejector basin vent must be piped as a continuous, rigid, gas-tight vent extending outdoors through the roof or connecting to an existing vent stack above the highest fixture flood rim.