Study guide
8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing
Michigan Roofing Contractor Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The Exam & Michigan Licensing Law
1.1 The Michigan Roofing License Exam: Format, Fees & Test-Day Rules 1.2 Who Must Be Licensed: Residential Builder vs. M&A Roofing & the Exemptions 1.3 Prelicensure Education, Application, Renewal & Continuing Competency 1.4 Company Licenses, Qualifying Officers, Salespersons & Reporting Changes 1.5 Rules of Conduct: Place of Business, Advertising, Written Agreements & Records 1.6 Complaints, Investigations, Hearings, Arbitration & Penalties
2 Chapter 2: Codes, Permits, Civil Rights & Environmental Rules
2.1 The State Construction Code, Permits & Inspections 2.2 Civil Rights, Fair Housing, ADA & Michigan Barrier-Free Design 2.3 EPA Hazardous-Materials Rules: Lead-Safe Renovation, Asbestos & Radon
3 Chapter 3: Business Organization, Contracts & In-Home Sales
3.1 Types of Business Organization: Sole Proprietorship, Partnership, LLC & Corporation 3.2 Contract Essentials: Requirements, Types, Terminology & When a Contract Binds 3.3 Addenda, Change Orders, Allowances, Schedules, Warranties, Financing & Breach 3.4 In-Home Sales: The Home Solicitation Sales Act & Door-to-Door Roofing Sales
4 Chapter 4: Project Management, Accounting, Taxes & Personnel
4.1 Project Management & Administration: Quality, Logistics, Schedules, Draws & Retainage 4.2 Accounting & Finance: Costs, Receivables, Cash Flow, Financial Statements & Ratios 4.3 Payroll & Tax Obligations: Federal, Michigan, Unemployment & Sales/Use Tax 4.4 Personnel: MIOSHA Administration, Recordkeeping, Wages, Minors & Benefits
5 Chapter 5: Insurance, Bonds & Construction Liens
5.1 Insurance for Roofing Contractors: Liability, Workers' Compensation, Vehicles, Property & Builders' Risk 5.2 Bonds, Public Works Bonding & the Building Contract Fund Act 5.3 Construction Lien Act I: Notices of Commencement & Furnishing, Sworn Statements & Waivers 5.4 Construction Lien Act II: Claims of Lien, Foreclosure, Priority & Residential Protections
6 Chapter 6: Roofing Safety & Public Protection (MIOSHA)
6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems 6.2 Guardrails, Safety Nets, Warning Lines, Safety Monitors, Covers & Fall Protection Plans 6.3 Ladders, Scaffolds, Roof Brackets & Aerial Lifts (MIOSHA Parts 11, 12 & 32) 6.4 Hazard Communication, SDS, Silica, Lead & Asbestos Exposure, Power Lines & Heat 6.5 Hoisting & Lift Equipment, Fire Prevention, PPE, Barricades, Debris & Recycling
7 Chapter 7: Planning, Structure & Estimating
7.1 Roof Types, Framing Terminology & Structural Loads 7.2 Pre-Job Walk-Through, Plans & Details, Permits & Selecting the Roof System 7.3 Roof Geometry, Slope, Pitch & Slope Factors for Measuring Roofs 7.4 Material Takeoffs: Squares, Bundles, Waste, Underlayment, Ice Barrier, Metals & Fasteners 7.5 Labor, Subcontractor & Access Costs and Preparing the Estimate
8 Chapter 8: Tear-Off, Deck Preparation & Underlayment
8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing 8.2 Tear-Off vs. Recover, Reroofing Rules & Preparing the Site (MRC R908) 8.3 Michigan's Ice Barrier Requirement: Coverage, Materials & Detailing (R905.1.2) 8.4 Underlayment: Standards, Application by Slope & Attachment (R905.1.1) 8.5 Roof & Ceiling Insulation, Vapor Retarders, Air Sealing & Unvented Assemblies
9 Chapter 9: Steep-Slope Roof Systems
9.1 Asphalt Shingles: Types, ASTM D3462, Wind Classes, Impact & Fire Ratings 9.2 Installing Asphalt Shingles: Starter, Exposure, Nailing, Steep Slopes & Caps 9.3 Valleys: Linings, Open Metal, Closed-Cut & Woven Valleys 9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes
10 Chapter 10: Low-Slope Roof Systems & Drainage
10.1 Single-Ply Membranes: EPDM, TPO & PVC 10.2 Built-Up Roofing & Modified Bitumen: Materials, Application, Kettles & Torch Safety 10.3 Low-Slope Drainage: Positive Drainage, Roof Drains, Overflow Scuppers & Correcting Ponding
11 Chapter 11: Flashings, Transitions & Penetrations
11.1 Drip Edge & Roof-Edge Metals (R905.2.8.5 and R903.2) 11.2 Sidewalls, Headwalls, Kick-Outs, Counterflashing & Pitch Transitions 11.3 Chimneys & Crickets, Skylights, Pipes, Flues, Exhaust Vents & Solar
12 Chapter 12: Ventilation, Inspection & Repair
12.1 Attic Ventilation Requirements & Net Free Vent Area Calculations (MRC R806) 12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams 12.3 Roof Inspections, Leak Diagnosis, Repairs & Roofovers
8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing
Key Takeaways Explain This Topic AI
Asphalt shingles must be fastened to solidly sheathed decks (R905.2.1), and spaced lumber sheathing is allowed only for wood shingles and shakes.
Wood structural panels must carry a grade mark showing grade, bond classification, and performance category, and roof sheathing exposed only on its underside may be Exposure 1.
A 24/16 panel (7/16 inch) spans 24 inches on a roof with edge support, and 24 inches without edge support. A 24/0 panel (3/8 inch) spans 24 inches with edge support but only 20 inches without.
Edge support can be lumber blocking, tongue-and-groove edges, or panel edge clips: one clip midway between supports, and two clips where the span is 48 inches.
Roof sheathing 3/8 to 1/2 inch thick is nailed with 8d common nails (2 1/2 by 0.131 inch) at 6 inches on center at supported edges and 12 inches in the field, with tighter gable-end and intermediate spacing where the wind rules require.
Last updated: September 2026
Why the Deck Matters
The deck is the base of the whole roof. It carries loads to the framing, acts as a diaphragm against wind, and holds the fasteners. R905.2.1 says asphalt shingles shall be fastened to solidly sheathed decks. PSI's outline includes installing deck sheathing and identifying and correcting unacceptable framing or sheathing.
- Materials
- Wood Structural Panels (R803.2)
Plywood and OSB panels must meet DOC PS 1, DOC PS 2 , or the listed CSA standards. They must bear a grade mark showing grade, bond classification (for example, Exposure 1), and performance category . Panels permanently exposed outdoors must be exterior-grade. Roof sheathing exposed only on its underside may be Exposure 1 . Allowable spans come from Table R503.2.1.1(1) .
Lumber Sheathing (R803.1)
Solid lumber sheathing must meet Table R803.1. For 24-inch rafter spacing, the minimum net thickness is 5/8 inch . Spaced lumber sheathing is permitted only for wood shingle and shake roofs (R905.7, R905.8), so a shingle roof over spaced boards needs new solid sheathing.
Many older Michigan homes have 1-by board decks. Before shingling over boards, check for rot, large gaps, knotholes, and cupping. Many shingle manufacturers limit board width and gap size, and require panel overlay where boards are too wide, too open, or too uneven. Follow their instructions and the solid-deck rule.
Reading the Span Rating
A panel stamped 32/16 may span up to 32 inches as roof sheathing and 16 inches as subflooring, with its long dimension across the supports and continuous over two or more spans. Key roof spans from Table R503.2.1.1(1):
- Span rating Minimum nominal thickness Roof span with edge support Roof span without edge support
- 16/0 3/8 in 16 in 16 in
- 20/0 3/8 in 20 in 20 in
- 24/0 3/8 in 24 in 20 in
- 24/16 7/16 in 24 in 24 in
- 32/16 15/32, 1/2 in 32 in 28 in
- 40/20 19/32, 5/8 in 40 in 32 in
- 48/24 23/32, 3/4 in 48 in 36 in
The table's loads assume a 10 psf dead load. If dead load exceeds that, as with tile or heavy snow design, the live load must be reduced accordingly. That is one reason heavy coverings and northern Michigan loads call for thicker panels or closer framing. The rafters or trusses themselves must also be designed for the snow load (Section 7.1).
Edge Support
"With edge support" means one of these (table footnote):
- lumber blocking;
- panel edge clips , one midway between each support, or two equally spaced where the span is 48 inches ;
- tongue-and-groove panel edges;
another approved type of edge support.
Without edge support, an unsupported panel edge can deflect under a worker's foot and crack shingle seal strips.
Fastening (Table R602.3(1))
- Panel thickness Fastener Edges Intermediate supports
- 3/8 to 1/2 in 8d common (2 1/2 × 0.131 in) for roof sheathing 6 in 12 in
- 19/32 to 1 in 8d common 6 in 12 in
- 1 1/8 to 1 1/4 in 10d common or 8d deformed 6 in 12 in
The table's wind footnote:
Where the ultimate design wind speed is 130 mph or less , nails attaching roof sheathing to gable end wall framing are spaced 6 inches on center .
Where the ultimate design wind speed is greater than 130 mph , nails at intermediate supports are spaced 6 inches on center within 48 inches of ridges, eaves, and gable end walls, and 4 inches at gable end walls.
Michigan's design table lists a 90 mph basic wind speed, and most of the state is well under the 130 mph ultimate threshold. The usual Michigan schedule is therefore 6 inches at edges and 12 inches in the field , plus 6 inches along gable-end framing. Table R602.3(2) lists alternate staples and nails.
Installation Practice
Orientation: long dimension (strength axis) perpendicular to rafters or trusses, continuous over at least two spans.
Joints: end joints bear on framing. Stagger end joints between courses, following APA and panel-maker instructions.
Spacing: APA recommends a gap of about 1/8 inch at panel ends and edges to allow for moisture expansion, unless the manufacturer says otherwise. Butted panels can buckle and telegraph ridges through shingles.
Nailing: drive nails flush, about 3/8 inch from panel edges, into the framing. Overdriven nails reduce holding power. Nails that miss framing ("shiners") should be pulled and re-driven.
Moisture: protect panels from prolonged wetting. OSB edges that swell may not recover.
Matching thickness: when replacing decking, match the existing thickness so there is no step that will show through the roofing or cut the underlayment.
Replacing Damaged Deck During Tear-Off
Cut back rotted or delaminated sheathing to the centers of framing members so new and old panels both bear on framing.
Use pieces large enough to span at least two framing bays where practical, with blocking under any unsupported edges.
Check framing under the rot. Soft rafter tails and fascia often come with deck rot at the eaves.
Record the quantity for the unit-price change order (Sections 3.3 and 7.5).
Deck Problems to Correct Before Roofing
- Problem Correction
- Spaced boards under a shingle roof Install solid sheathing (R905.2.1)
- Soft, delaminated, or rotted areas Replace to framing centers
Panels too thin for the framing spacing, or unsupported edges Add clips or blocking, or overlay with properly rated panels
- Protruding nails and ridges Re-nail, plane, or replace the high spots
- Excessive deflection between framing Evaluate the framing. Sister or repair with design guidance if needed