Study guide
10.1 Single-Ply Membranes: EPDM, TPO & PVC
Michigan Roofing Contractor Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The Exam & Michigan Licensing Law
1.1 The Michigan Roofing License Exam: Format, Fees & Test-Day Rules 1.2 Who Must Be Licensed: Residential Builder vs. M&A Roofing & the Exemptions 1.3 Prelicensure Education, Application, Renewal & Continuing Competency 1.4 Company Licenses, Qualifying Officers, Salespersons & Reporting Changes 1.5 Rules of Conduct: Place of Business, Advertising, Written Agreements & Records 1.6 Complaints, Investigations, Hearings, Arbitration & Penalties
2 Chapter 2: Codes, Permits, Civil Rights & Environmental Rules
2.1 The State Construction Code, Permits & Inspections 2.2 Civil Rights, Fair Housing, ADA & Michigan Barrier-Free Design 2.3 EPA Hazardous-Materials Rules: Lead-Safe Renovation, Asbestos & Radon
3 Chapter 3: Business Organization, Contracts & In-Home Sales
3.1 Types of Business Organization: Sole Proprietorship, Partnership, LLC & Corporation 3.2 Contract Essentials: Requirements, Types, Terminology & When a Contract Binds 3.3 Addenda, Change Orders, Allowances, Schedules, Warranties, Financing & Breach 3.4 In-Home Sales: The Home Solicitation Sales Act & Door-to-Door Roofing Sales
4 Chapter 4: Project Management, Accounting, Taxes & Personnel
4.1 Project Management & Administration: Quality, Logistics, Schedules, Draws & Retainage 4.2 Accounting & Finance: Costs, Receivables, Cash Flow, Financial Statements & Ratios 4.3 Payroll & Tax Obligations: Federal, Michigan, Unemployment & Sales/Use Tax 4.4 Personnel: MIOSHA Administration, Recordkeeping, Wages, Minors & Benefits
5 Chapter 5: Insurance, Bonds & Construction Liens
5.1 Insurance for Roofing Contractors: Liability, Workers' Compensation, Vehicles, Property & Builders' Risk 5.2 Bonds, Public Works Bonding & the Building Contract Fund Act 5.3 Construction Lien Act I: Notices of Commencement & Furnishing, Sworn Statements & Waivers 5.4 Construction Lien Act II: Claims of Lien, Foreclosure, Priority & Residential Protections
6 Chapter 6: Roofing Safety & Public Protection (MIOSHA)
6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems 6.2 Guardrails, Safety Nets, Warning Lines, Safety Monitors, Covers & Fall Protection Plans 6.3 Ladders, Scaffolds, Roof Brackets & Aerial Lifts (MIOSHA Parts 11, 12 & 32) 6.4 Hazard Communication, SDS, Silica, Lead & Asbestos Exposure, Power Lines & Heat 6.5 Hoisting & Lift Equipment, Fire Prevention, PPE, Barricades, Debris & Recycling
7 Chapter 7: Planning, Structure & Estimating
7.1 Roof Types, Framing Terminology & Structural Loads 7.2 Pre-Job Walk-Through, Plans & Details, Permits & Selecting the Roof System 7.3 Roof Geometry, Slope, Pitch & Slope Factors for Measuring Roofs 7.4 Material Takeoffs: Squares, Bundles, Waste, Underlayment, Ice Barrier, Metals & Fasteners 7.5 Labor, Subcontractor & Access Costs and Preparing the Estimate
8 Chapter 8: Tear-Off, Deck Preparation & Underlayment
8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing 8.2 Tear-Off vs. Recover, Reroofing Rules & Preparing the Site (MRC R908) 8.3 Michigan's Ice Barrier Requirement: Coverage, Materials & Detailing (R905.1.2) 8.4 Underlayment: Standards, Application by Slope & Attachment (R905.1.1) 8.5 Roof & Ceiling Insulation, Vapor Retarders, Air Sealing & Unvented Assemblies
9 Chapter 9: Steep-Slope Roof Systems
9.1 Asphalt Shingles: Types, ASTM D3462, Wind Classes, Impact & Fire Ratings 9.2 Installing Asphalt Shingles: Starter, Exposure, Nailing, Steep Slopes & Caps 9.3 Valleys: Linings, Open Metal, Closed-Cut & Woven Valleys 9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes
10 Chapter 10: Low-Slope Roof Systems & Drainage
10.1 Single-Ply Membranes: EPDM, TPO & PVC 10.2 Built-Up Roofing & Modified Bitumen: Materials, Application, Kettles & Torch Safety 10.3 Low-Slope Drainage: Positive Drainage, Roof Drains, Overflow Scuppers & Correcting Ponding
11 Chapter 11: Flashings, Transitions & Penetrations
11.1 Drip Edge & Roof-Edge Metals (R905.2.8.5 and R903.2) 11.2 Sidewalls, Headwalls, Kick-Outs, Counterflashing & Pitch Transitions 11.3 Chimneys & Crickets, Skylights, Pipes, Flues, Exhaust Vents & Solar
12 Chapter 12: Ventilation, Inspection & Repair
12.1 Attic Ventilation Requirements & Net Free Vent Area Calculations (MRC R806) 12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams 12.3 Roof Inspections, Leak Diagnosis, Repairs & Roofovers
10.1 Single-Ply Membranes: EPDM, TPO & PVC
Key Takeaways Explain This Topic AI
Thermoset (EPDM) and thermoplastic (TPO, PVC) single-ply roofs need a design slope of at least 1/4:12 (2%) for drainage.
EPDM is a thermoset rubber (ASTM D4637), joined with primer and seam tape or adhesive, and it cannot be heat-welded.
TPO (ASTM D6878) and PVC (ASTM D4434) are thermoplastics whose seams are fused by hot-air welding, and welded seams should be probed after cooling.
Single-ply membranes are ballasted, mechanically attached, or fully adhered, and the choice depends on the deck, wind exposure, weight limits, and the manufacturer's system approval.
Above-deck insulation under a membrane must meet FM 4450 or UL 1256 and be covered by an approved roof covering (R906).
Last updated: September 2026
Code Basics
- System 2015 MRC section Minimum design slope Material standards
- Thermoset single-ply (EPDM) R905.12 1/4:12 (2%) ASTM D4637, ASTM D5019, or CGSB 37-GP-52M
Thermoplastic single-ply (TPO, PVC, KEE) R905.13 1/4:12 (2%) ASTM D4434 (PVC), D6754 (ketone ethylene ester), D6878 (TPO), or CAN/CGSB 37.54
Both are installed "in accordance with this chapter and the manufacturer's instructions." Because the roof covering sections list no additional details, the membrane manufacturer's system instructions are the working specification. They cover deck and insulation requirements, attachment, seams, flashing heights, and edge details. The PSI roofing references include the NRCA Roofing Manual: Membrane Roof Systems .
Comparing the Membranes
- Property EPDM TPO PVC
- Polymer type Thermoset (vulcanized rubber) Thermoplastic polyolefin Thermoplastic vinyl, with plasticizers
- Seam method Primer plus seam tape , or seam adhesive. Cannot be heat-welded Hot-air welded Hot-air welded
- Typical colors Black, also white White, gray, tan White and colors
Strengths Flexible in cold, long record, easy repairs Reflective, strong welded seams Welded seams, good resistance to many chemicals and greases
Watch-outs Petroleum products and some oils can swell it. Seams depend on clean, primed surfaces Welding window depends on the product and weather. Needs clean, compatible surfaces Plasticized PVC is incompatible with asphalt and some polystyrene insulations unless separated, per the manufacturer
Attachment Methods
Method How it works Notes
Ballasted Loose-laid membrane held down by stone or pavers Heavy. The structure must carry the load, and wind exposure limits its use. Rare on homes
Mechanically attached Fasteners and plates at seams or through the membrane into the deck, covered by the overlapping sheet Light. The membrane can billow in wind, so fastener rows follow the manufacturer's wind design
Fully adhered Bonding adhesive over an approved substrate or cover board. Self-adhered membranes are also available Best appearance and wind resistance. Adhesives have temperature and flash-off limits
On a small residential porch roof, fully adhered EPDM or TPO over a clean, dry deck or insulation board is common. Follow the manufacturer's approved assembly for the deck type and wind zone.
- Seams
- EPDM
Position sheets with the manufacturer's minimum lap.
Clean and prime both surfaces with the specified primer, and let it flash off.
Apply seam tape (or seam adhesive) and roll the seam firmly with a hand roller toward the edge.
Seal the laps at T-joints and cut edges with lap sealant, and install T-joint covers where the manufacturer requires.
TPO and PVC
Set the hot-air welder's temperature and speed for the day's conditions, and make test welds first. Peel them to confirm the membrane tears before the weld does.
Weld the laps with an automatic welder or a hand welder and roller.
After the seams cool, probe every seam with a blunt probe to find voids. Repair voids by rewelding or with a patch.
Keep seams clean. Dirt, moisture, and old coatings cause weak welds. Use the manufacturer's cleaner on aged membrane before welding.
Flashings and Terminations
Base flashings at walls and curbs extend up the wall and terminate under counterflashing or a termination bar sealed per the manufacturer. NRCA commonly recommends base flashing at least 8 inches above the finished roof surface. Follow the manufacturer's minimum.
Penetrations: use prefabricated pipe boots where possible. For irregular shapes, use field-fabricated flashing or pitch pans filled with the manufacturer's sealant, and inspect them often.
Edges: metal drip edge or gravel stop with the membrane stripped in. Where low-slope roofing meets a shingled slope, lap the membrane up under the shingle underlayment and ice barrier so water flows over the joint, not into it.
Drains and scuppers: clamp or weld the membrane into drain bowls and scupper sleeves per the manufacturer (Section 10.3).
Insulation and Cover Boards
R906.1: above-deck thermal insulation is allowed if it is covered by an approved roof covering and complies with FM 4450 or UL 1256 .
Board standards are in Table R906.2: polyiso (ASTM C1289), EPS and XPS (C578), perlite, wood fiberboard, and gypsum boards.
Tapered insulation creates slope to drains (Section 10.3).
Cover boards protect insulation from foot traffic and provide a smooth, compatible surface for adhered membranes.
Never install over wet insulation or a wet deck. Replace wet insulation found during tear-off.
Weather and Temperature
Adhesives, primers, and tapes have minimum temperature and humidity limits, and cold slows flash-off and cure. Welding changes with ambient temperature and wind. Store adhesives warm, follow the instructions, and do not seam over frost or dew.
Maintenance and Repair Basics
EPDM repairs: clean and prime around the damage, then apply a cured or uncured EPDM patch with seam tape. Round the corners and roll the patch firmly.
TPO and PVC repairs: clean with the manufacturer's cleaner, then weld a patch of the same material. Aged membrane may need extra preparation.
Keep walkway pads at service routes, such as around HVAC units, and clear debris from drains regularly.