Study guide

6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems

Michigan Roofing Contractor Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The Exam & Michigan Licensing Law

1.1 The Michigan Roofing License Exam: Format, Fees & Test-Day Rules 1.2 Who Must Be Licensed: Residential Builder vs. M&A Roofing & the Exemptions 1.3 Prelicensure Education, Application, Renewal & Continuing Competency 1.4 Company Licenses, Qualifying Officers, Salespersons & Reporting Changes 1.5 Rules of Conduct: Place of Business, Advertising, Written Agreements & Records 1.6 Complaints, Investigations, Hearings, Arbitration & Penalties

2 Chapter 2: Codes, Permits, Civil Rights & Environmental Rules

2.1 The State Construction Code, Permits & Inspections 2.2 Civil Rights, Fair Housing, ADA & Michigan Barrier-Free Design 2.3 EPA Hazardous-Materials Rules: Lead-Safe Renovation, Asbestos & Radon

3 Chapter 3: Business Organization, Contracts & In-Home Sales

3.1 Types of Business Organization: Sole Proprietorship, Partnership, LLC & Corporation 3.2 Contract Essentials: Requirements, Types, Terminology & When a Contract Binds 3.3 Addenda, Change Orders, Allowances, Schedules, Warranties, Financing & Breach 3.4 In-Home Sales: The Home Solicitation Sales Act & Door-to-Door Roofing Sales

4 Chapter 4: Project Management, Accounting, Taxes & Personnel

4.1 Project Management & Administration: Quality, Logistics, Schedules, Draws & Retainage 4.2 Accounting & Finance: Costs, Receivables, Cash Flow, Financial Statements & Ratios 4.3 Payroll & Tax Obligations: Federal, Michigan, Unemployment & Sales/Use Tax 4.4 Personnel: MIOSHA Administration, Recordkeeping, Wages, Minors & Benefits

5 Chapter 5: Insurance, Bonds & Construction Liens

5.1 Insurance for Roofing Contractors: Liability, Workers' Compensation, Vehicles, Property & Builders' Risk 5.2 Bonds, Public Works Bonding & the Building Contract Fund Act 5.3 Construction Lien Act I: Notices of Commencement & Furnishing, Sworn Statements & Waivers 5.4 Construction Lien Act II: Claims of Lien, Foreclosure, Priority & Residential Protections

6 Chapter 6: Roofing Safety & Public Protection (MIOSHA)

6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems 6.2 Guardrails, Safety Nets, Warning Lines, Safety Monitors, Covers & Fall Protection Plans 6.3 Ladders, Scaffolds, Roof Brackets & Aerial Lifts (MIOSHA Parts 11, 12 & 32) 6.4 Hazard Communication, SDS, Silica, Lead & Asbestos Exposure, Power Lines & Heat 6.5 Hoisting & Lift Equipment, Fire Prevention, PPE, Barricades, Debris & Recycling

7 Chapter 7: Planning, Structure & Estimating

7.1 Roof Types, Framing Terminology & Structural Loads 7.2 Pre-Job Walk-Through, Plans & Details, Permits & Selecting the Roof System 7.3 Roof Geometry, Slope, Pitch & Slope Factors for Measuring Roofs 7.4 Material Takeoffs: Squares, Bundles, Waste, Underlayment, Ice Barrier, Metals & Fasteners 7.5 Labor, Subcontractor & Access Costs and Preparing the Estimate

8 Chapter 8: Tear-Off, Deck Preparation & Underlayment

8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing 8.2 Tear-Off vs. Recover, Reroofing Rules & Preparing the Site (MRC R908) 8.3 Michigan's Ice Barrier Requirement: Coverage, Materials & Detailing (R905.1.2) 8.4 Underlayment: Standards, Application by Slope & Attachment (R905.1.1) 8.5 Roof & Ceiling Insulation, Vapor Retarders, Air Sealing & Unvented Assemblies

9 Chapter 9: Steep-Slope Roof Systems

9.1 Asphalt Shingles: Types, ASTM D3462, Wind Classes, Impact & Fire Ratings 9.2 Installing Asphalt Shingles: Starter, Exposure, Nailing, Steep Slopes & Caps 9.3 Valleys: Linings, Open Metal, Closed-Cut & Woven Valleys 9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes

10 Chapter 10: Low-Slope Roof Systems & Drainage

10.1 Single-Ply Membranes: EPDM, TPO & PVC 10.2 Built-Up Roofing & Modified Bitumen: Materials, Application, Kettles & Torch Safety 10.3 Low-Slope Drainage: Positive Drainage, Roof Drains, Overflow Scuppers & Correcting Ponding

11 Chapter 11: Flashings, Transitions & Penetrations

11.1 Drip Edge & Roof-Edge Metals (R905.2.8.5 and R903.2) 11.2 Sidewalls, Headwalls, Kick-Outs, Counterflashing & Pitch Transitions 11.3 Chimneys & Crickets, Skylights, Pipes, Flues, Exhaust Vents & Solar

12 Chapter 12: Ventilation, Inspection & Repair

12.1 Attic Ventilation Requirements & Net Free Vent Area Calculations (MRC R806) 12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams 12.3 Roof Inspections, Leak Diagnosis, Repairs & Roofovers

6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems

Key Takeaways Explain This Topic AI

MIOSHA Part 45 adopts 29 CFR 1926.500 to 1926.503 by reference, so federal Subpart M rules are Michigan's fall protection rules for construction.

Workers in residential construction and on steep roofs (slope greater than 4:12) must be protected at 6 feet or more by guardrails, safety nets, or personal fall arrest systems.

Personal fall arrest anchorages must hold 5,000 pounds per attached worker, or be designed with a safety factor of at least 2 under a qualified person.

A harness system must limit arresting force to 1,800 pounds, free fall to 6 feet, and deceleration distance to 3.5 feet, and only locking snaphooks may be used.

Equipment that has arrested a fall must be removed from service until a competent person inspects it and finds it undamaged, and the employer must provide for prompt rescue.

Last updated: September 2026

Michigan's Fall Protection Rule

Michigan runs its own OSHA-approved state plan, MIOSHA , under 1974 PA 154. For construction fall protection, Part 45 (R 408.44501–44502, amended April 2015) adopts by reference 29 CFR 1926.500, .501, .502, and .503 , known as federal Subpart M. Part 45 also points to other MIOSHA parts for special situations: ladders in Part 11 , scaffolds in Part 12 , and aerial work platforms in Part 32 (Section 6.3).

Key definitions from 1926.500:

Low-slope roof: slope less than or equal to 4 in 12 .

Steep roof: slope greater than 4 in 12 .

Competent person: someone able to identify hazards who has authority to correct them promptly.

Qualified person: someone with a degree, certificate, or extensive experience who can solve problems related to the subject.

Who Must Be Protected (1926.501)

Situation Trigger Acceptable protection

Residential construction (b)(13) 6 feet or more above a lower level Guardrails, safety nets, or personal fall arrest. A written site-specific fall protection plan only if the employer shows those are infeasible or create a greater hazard

Steep roofs (b)(11) 6 feet or more Guardrails with toeboards , safety nets, or personal fall arrest

Low-slope roofing work (b)(10) 6 feet or more Guardrails, nets, personal fall arrest, or a warning line combined with one of those or with a safety monitor. On roofs 50 feet or less wide , a safety monitor alone (Section 6.2)

Holes, including skylights (b)(4) More than 6 feet Personal fall arrest, covers, or guardrails around the hole (Section 6.2)

Subpart M presumes that at least one conventional system is feasible for residential work. A fall protection plan is the exception, not the default.

Personal Fall Arrest Systems (1926.502(d))

A personal fall arrest system combines three parts: an anchorage , a full-body harness , and a connector (lanyard, self-retracting lifeline, or rope grab on a lifeline).

Requirement Rule

Anchorage strength Holds 5,000 pounds per attached employee , or is designed, installed, and used as part of a complete system with a safety factor of at least 2 , under a qualified person ((d)(15))

Maximum arresting force 1,800 pounds with a body harness ((d)(16)(ii))

Free fall Rigged so the worker can neither free fall more than 6 feet nor contact any lower level ((d)(16)(iii))

Deceleration distance Worker stopped within 3.5 feet of deceleration ((d)(16)(iv))

Snaphooks Locking type only since January 1, 1998. Not clipped to each other, to webbing, or to a D-ring already holding another connector unless designed for it ((d)(5)–(6))

  • Body belts Prohibited for fall arrest since January 1, 1998. A full-body harness is required
  • Vertical lifelines One employee per lifeline, and lanyards and lifelines rated at 5,000 pounds ((d)(9)–(10))
  • Attachment Not tied to guardrail systems or to hoists ((d)(23))
  • Roof Anchors

Install roof anchors exactly as the manufacturer instructs. Most require fastening through the sheathing into rafters or truss top chords with specified fasteners, not just into the deck. Place the anchor as nearly above or up-slope of the work as possible to limit swing falls , where a worker offset from the anchor swings sideways into walls or off a rake.

Inspection, Impact, and Rescue

Inspect the system before each use for wear, damage, and deterioration, and remove defective parts from service ((d)(21)). Check webbing for cuts, burns from torches or hot asphalt, and chemical damage. Check hardware for cracks and distortion, and check impact indicators.

Equipment that arrests a fall, or is otherwise impact loaded , must be removed from service immediately and not reused until a competent person inspects it and finds it undamaged and suitable ((d)(19)). Many manufacturers require retiring impact-loaded lanyards and self-retracting lifelines, so follow their instructions.

The employer must provide for prompt rescue of a fallen worker or make sure workers can rescue themselves ((d)(20)). Suspension in a harness quickly becomes a medical emergency, so plan the rescue before work starts.

Training and Certification (1926.503)

Each employee exposed to fall hazards must be trained by a competent person to recognize hazards and use the systems.

The employer keeps a written certification record with the employee's name, the training dates, and the signature of the trainer or employer.

Retrain when the workplace, the equipment, or the worker's performance shows the training is out of date.

MIOSHA publishes a Part 45 quick guide and a sample fall protection plan for residential construction . The sample is useful for seeing what a site-specific plan must contain. It does not replace conventional protection when conventional protection is feasible.

Estimating Fall Clearance

A lanyard that stops a fall after the worker hits the ground is useless. Clearance below the anchor depends on the equipment. Manufacturers publish clearance charts, and a typical estimate for a 6-foot shock-absorbing lanyard attached at back level adds these items:

  • Component Typical value
  • Lanyard length (free fall) 6.0 ft
  • Deceleration distance (maximum) 3.5 ft
  • D-ring to feet, including harness stretch About 5.0 ft
  • Safety margin Commonly 2 to 3 ft
  • Total below the anchor About 16.5 to 17.5 ft

On a single-story ranch with an 8-foot eave, a 6-foot shock-absorbing lanyard at deck level cannot keep a falling worker off the ground. Use a self-retracting lifeline rated for the setup (leading-edge rated if anchored at foot level), a rope grab on a ridge-anchored lifeline kept short, guardrails, or roof brackets with guardrails.

Worked Scenario

A crew reroofs a two-story colonial with a 9:12 roof and eaves 18 feet above grade. The roof is steep, and the work is more than 6 feet up, so the crew needs guardrails with toeboards, nets, or personal fall arrest. The foreman installs two anchors near the ridge into rafters, following the manufacturer's instructions. Each worker has a full-body harness and a rope grab on a separate vertical lifeline, kept adjusted to limit slack. Every harness is inspected at the start of the shift, and a ladder and trained coworker are available for rescue.