Study guide

9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes

Michigan Roofing Contractor Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The Exam & Michigan Licensing Law

1.1 The Michigan Roofing License Exam: Format, Fees & Test-Day Rules 1.2 Who Must Be Licensed: Residential Builder vs. M&A Roofing & the Exemptions 1.3 Prelicensure Education, Application, Renewal & Continuing Competency 1.4 Company Licenses, Qualifying Officers, Salespersons & Reporting Changes 1.5 Rules of Conduct: Place of Business, Advertising, Written Agreements & Records 1.6 Complaints, Investigations, Hearings, Arbitration & Penalties

2 Chapter 2: Codes, Permits, Civil Rights & Environmental Rules

2.1 The State Construction Code, Permits & Inspections 2.2 Civil Rights, Fair Housing, ADA & Michigan Barrier-Free Design 2.3 EPA Hazardous-Materials Rules: Lead-Safe Renovation, Asbestos & Radon

3 Chapter 3: Business Organization, Contracts & In-Home Sales

3.1 Types of Business Organization: Sole Proprietorship, Partnership, LLC & Corporation 3.2 Contract Essentials: Requirements, Types, Terminology & When a Contract Binds 3.3 Addenda, Change Orders, Allowances, Schedules, Warranties, Financing & Breach 3.4 In-Home Sales: The Home Solicitation Sales Act & Door-to-Door Roofing Sales

4 Chapter 4: Project Management, Accounting, Taxes & Personnel

4.1 Project Management & Administration: Quality, Logistics, Schedules, Draws & Retainage 4.2 Accounting & Finance: Costs, Receivables, Cash Flow, Financial Statements & Ratios 4.3 Payroll & Tax Obligations: Federal, Michigan, Unemployment & Sales/Use Tax 4.4 Personnel: MIOSHA Administration, Recordkeeping, Wages, Minors & Benefits

5 Chapter 5: Insurance, Bonds & Construction Liens

5.1 Insurance for Roofing Contractors: Liability, Workers' Compensation, Vehicles, Property & Builders' Risk 5.2 Bonds, Public Works Bonding & the Building Contract Fund Act 5.3 Construction Lien Act I: Notices of Commencement & Furnishing, Sworn Statements & Waivers 5.4 Construction Lien Act II: Claims of Lien, Foreclosure, Priority & Residential Protections

6 Chapter 6: Roofing Safety & Public Protection (MIOSHA)

6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems 6.2 Guardrails, Safety Nets, Warning Lines, Safety Monitors, Covers & Fall Protection Plans 6.3 Ladders, Scaffolds, Roof Brackets & Aerial Lifts (MIOSHA Parts 11, 12 & 32) 6.4 Hazard Communication, SDS, Silica, Lead & Asbestos Exposure, Power Lines & Heat 6.5 Hoisting & Lift Equipment, Fire Prevention, PPE, Barricades, Debris & Recycling

7 Chapter 7: Planning, Structure & Estimating

7.1 Roof Types, Framing Terminology & Structural Loads 7.2 Pre-Job Walk-Through, Plans & Details, Permits & Selecting the Roof System 7.3 Roof Geometry, Slope, Pitch & Slope Factors for Measuring Roofs 7.4 Material Takeoffs: Squares, Bundles, Waste, Underlayment, Ice Barrier, Metals & Fasteners 7.5 Labor, Subcontractor & Access Costs and Preparing the Estimate

8 Chapter 8: Tear-Off, Deck Preparation & Underlayment

8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing 8.2 Tear-Off vs. Recover, Reroofing Rules & Preparing the Site (MRC R908) 8.3 Michigan's Ice Barrier Requirement: Coverage, Materials & Detailing (R905.1.2) 8.4 Underlayment: Standards, Application by Slope & Attachment (R905.1.1) 8.5 Roof & Ceiling Insulation, Vapor Retarders, Air Sealing & Unvented Assemblies

9 Chapter 9: Steep-Slope Roof Systems

9.1 Asphalt Shingles: Types, ASTM D3462, Wind Classes, Impact & Fire Ratings 9.2 Installing Asphalt Shingles: Starter, Exposure, Nailing, Steep Slopes & Caps 9.3 Valleys: Linings, Open Metal, Closed-Cut & Woven Valleys 9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes

10 Chapter 10: Low-Slope Roof Systems & Drainage

10.1 Single-Ply Membranes: EPDM, TPO & PVC 10.2 Built-Up Roofing & Modified Bitumen: Materials, Application, Kettles & Torch Safety 10.3 Low-Slope Drainage: Positive Drainage, Roof Drains, Overflow Scuppers & Correcting Ponding

11 Chapter 11: Flashings, Transitions & Penetrations

11.1 Drip Edge & Roof-Edge Metals (R905.2.8.5 and R903.2) 11.2 Sidewalls, Headwalls, Kick-Outs, Counterflashing & Pitch Transitions 11.3 Chimneys & Crickets, Skylights, Pipes, Flues, Exhaust Vents & Solar

12 Chapter 12: Ventilation, Inspection & Repair

12.1 Attic Ventilation Requirements & Net Free Vent Area Calculations (MRC R806) 12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams 12.3 Roof Inspections, Leak Diagnosis, Repairs & Roofovers

9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes

Key Takeaways Explain This Topic AI

Minimum slopes for metal panels are 3:12 for lapped, nonsoldered seams without sealant, 1/2:12 with applied lap sealant, and 1/4:12 for standing-seam systems, and metal shingles need at least 3:12.

Without manufacturer instructions, steel roofs use galvanized fasteners, copper roofs use copper, brass, bronze, copper alloy, or 300-series stainless fasteners, and stainless fasteners are acceptable for metal roofs (R905.10.4).

Clay and concrete tile need at least 2 1/2:12, with double underlayment up to 4:12, and in areas subject to snow each tile needs at least two fasteners.

Slate requires at least 4:12, a solid deck, two fasteners per slate, and headlaps of 4 inches below 8:12, 3 inches from 8:12 to below 20:12, and 2 inches at steeper slopes.

Wood shingles and shakes need at least 3:12. Shakes are interlaid with 18-inch strips of No. 30 felt, and solid sheathing is required under the ice barrier area in cold climates.

Last updated: September 2026

Metal Roof Panels (R905.10)

  • Item Rule
  • Deck Solid or spaced sheathing, unless the covering is designed for spaced supports (R905.10.1)

Minimum slope (R905.10.2) 3:12 for lapped, nonsoldered-seam roofs without applied lap sealant. 1/2:12 with lap sealant applied per the manufacturer. 1/4:12 for standing-seam systems

Materials (Table R905.10.3(1)) Galvanized steel ASTM A653 G90 . Stainless steel ASTM A240 300 series. Aluminum ASTM B209, 0.024 inch minimum for roll-formed panels. Cold-rolled copper 16 oz per square foot (12 oz high-yield). Zinc 0.027 inch

Corrosion resistance (Table R905.10.3(2)) 55% aluminum-zinc coated steel AZ50. Galvanized G-90. Prepainted steel over one of the listed metallic coatings

Structural panels Systems with supporting structural members must be designed to the building code

Fasteners (R905.10.4) Follow the manufacturer. If there are no instructions: galvanized fasteners for steel roofs; copper, brass, bronze, copper alloy, or 300-series stainless for copper roofs. Stainless fasteners are acceptable for metal roofs generally

Underlayment (R905.10.5) Per R905.1.1. For metal panels at design wind speeds below 140 mph, apply per the manufacturer's instructions

Standing Seam vs. Exposed Fastener

Standing-seam panels join at raised seams and are held by concealed clips . Many clips let panels expand and contract with temperature. Mechanically seamed profiles suit the lowest slopes, down to 1/4:12, if the manufacturer rates them for it.

Exposed-fastener panels, such as ribbed or corrugated panels, are screwed through the face with sealing washers. They need the steeper slopes above unless the laps are sealed, and the washers age, so they need periodic inspection.

Thermal Movement, Dissimilar Metals, and Snow

Long panels move with temperature. Use the manufacturer's clips, expansion details, and trim so panels are not pinned at both ends.

Avoid galvanic corrosion : keep copper away from galvanized steel and aluminum, including copper runoff onto them. Use compatible fasteners, and separate dissimilar metals. The code requires compatible materials (R904.2).

Snow slides off metal roofs suddenly. Snow guards, placed where the manufacturer and site conditions call for them, protect walkways, decks, gutters, and lower roofs.

Metal Roof Shingles (R905.4)

Applied to a solid or closely fitted deck , unless designed for spaced sheathing.

Minimum slope 3:12. Underlayment per R905.1.1, and ice barrier where required, which means every Michigan home (R905.4.3.1).

Materials per Table R905.10.3(1), with corrosion resistance per Table R905.10.3(2). Aluminum press-formed shingles are at least 0.019 inch.

Valley flashing at least 8 inches each side of center, with a 3/4-inch diverter rib (Section 9.3).

Clay and Concrete Tile (R905.3)

  • Item Rule
  • Deck Solid sheathing or spaced structural sheathing boards
  • Slope At least 2 1/2:12 . Double underlayment from 2 1/2:12 to 4:12
  • Standards Clay tile ASTM C1167. Concrete tile ASTM C1492

Nails Corrosion-resistant, at least 11 gauge, 5/16-inch head, penetrating the deck at least 3/4 inch or through it. Tile wire at least 0.083 inch

Fastening Per the manufacturer and R905.3.7. Perimeter tiles get at least one fastener each. In areas subject to snow, at least two fasteners per tile

  • Weight Tile is heavy. The framing and deck must be designed for the load (R908.2; Section 7.1)
  • Slate (R905.6)
  • Item Rule
  • Deck Solidly sheathed
  • Slope At least 4:12
  • Standard ASTM C406
  • Fastening Two fasteners per slate

Headlap (Table R905.6.5) 4 inches for 4:12 to below 8:12. 3 inches for 8:12 to below 20:12. 2 inches at 20:12 and steeper

Valleys and flashing Sheet metal flashing and counterflashing. Valley flashing at least 15 inches wide, at least 0.0179-inch G90

Fire Slate over underlayment on a combustible deck counts as Class A (Michigan R902.1)

Exposure for slate is calculated from length and headlap:

Exposure = Slate length − Headlap 2 \text{Exposure} = \frac{\text{Slate length} - \text{Headlap}}{2} Exposure = 2 Slate length − Headlap ​

An 18-inch slate on a 10:12 roof, which takes a 3-inch headlap, has an exposure of (18 − 3) ÷ 2 = 7.5 inches .

Existing slate may be reinstalled, but damaged, cracked, or broken slate may not (R908.5). Slate repairs typically use copper or stainless nails and slate hooks or bibs as trade practice directs.

Wood Shingles (R905.7) and Wood Shakes (R905.8)

Item Wood shingles Wood shakes

Deck Solid, or spaced boards at least 1×4 spaced on centers equal to the exposure Same, with extra boards where 1×4s are spaced at 10 inches

Cold climate Solid sheathing where the ice barrier is required, in areas with an average January temperature of 25°F or less Same

Minimum slope 3:12 3:12

Grades No. 1, 2, or 3 (Cedar Shake and Shingle Bureau) No. 1 for naturally durable shakes. Tapersawn No. 1 or 2

  • Spacing between pieces 1/4 to 3/8 inch 3/8 to 5/8 inch
  • Side lap At least 1 1/2 inches, and no two joints aligned in any three adjacent courses At least 1 1/2 inches

Fasteners Stainless 304 or 316, or hot-dip galvanized ASTM A153 Class D. Two per piece, penetrating 3/4 inch or through the sheathing. Stainless 316 within 15 miles of salt water Same

Interlayment None specified 18-inch-wide strips of at least No. 30 felt between courses. The bottom edge of each strip sits above the shake butt by twice the weather exposure (R905.8.7). The starter course at the eave is doubled

Exposure Table R905.7.5(1) by length, grade, and slope. Example: 16-inch No. 1 at 5 inches on 4:12 and steeper Table R905.8.6. Example: 18-inch No. 1 at 7 1/2 inches

A recover with metal or tile over existing shakes must cover the old surface where it creates a combustible concealed space (R908.4; Section 8.2).