Study guide

12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams

Michigan Roofing Contractor Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The Exam & Michigan Licensing Law

1.1 The Michigan Roofing License Exam: Format, Fees & Test-Day Rules 1.2 Who Must Be Licensed: Residential Builder vs. M&A Roofing & the Exemptions 1.3 Prelicensure Education, Application, Renewal & Continuing Competency 1.4 Company Licenses, Qualifying Officers, Salespersons & Reporting Changes 1.5 Rules of Conduct: Place of Business, Advertising, Written Agreements & Records 1.6 Complaints, Investigations, Hearings, Arbitration & Penalties

2 Chapter 2: Codes, Permits, Civil Rights & Environmental Rules

2.1 The State Construction Code, Permits & Inspections 2.2 Civil Rights, Fair Housing, ADA & Michigan Barrier-Free Design 2.3 EPA Hazardous-Materials Rules: Lead-Safe Renovation, Asbestos & Radon

3 Chapter 3: Business Organization, Contracts & In-Home Sales

3.1 Types of Business Organization: Sole Proprietorship, Partnership, LLC & Corporation 3.2 Contract Essentials: Requirements, Types, Terminology & When a Contract Binds 3.3 Addenda, Change Orders, Allowances, Schedules, Warranties, Financing & Breach 3.4 In-Home Sales: The Home Solicitation Sales Act & Door-to-Door Roofing Sales

4 Chapter 4: Project Management, Accounting, Taxes & Personnel

4.1 Project Management & Administration: Quality, Logistics, Schedules, Draws & Retainage 4.2 Accounting & Finance: Costs, Receivables, Cash Flow, Financial Statements & Ratios 4.3 Payroll & Tax Obligations: Federal, Michigan, Unemployment & Sales/Use Tax 4.4 Personnel: MIOSHA Administration, Recordkeeping, Wages, Minors & Benefits

5 Chapter 5: Insurance, Bonds & Construction Liens

5.1 Insurance for Roofing Contractors: Liability, Workers' Compensation, Vehicles, Property & Builders' Risk 5.2 Bonds, Public Works Bonding & the Building Contract Fund Act 5.3 Construction Lien Act I: Notices of Commencement & Furnishing, Sworn Statements & Waivers 5.4 Construction Lien Act II: Claims of Lien, Foreclosure, Priority & Residential Protections

6 Chapter 6: Roofing Safety & Public Protection (MIOSHA)

6.1 MIOSHA Part 45 Fall Protection & Personal Fall Arrest Systems 6.2 Guardrails, Safety Nets, Warning Lines, Safety Monitors, Covers & Fall Protection Plans 6.3 Ladders, Scaffolds, Roof Brackets & Aerial Lifts (MIOSHA Parts 11, 12 & 32) 6.4 Hazard Communication, SDS, Silica, Lead & Asbestos Exposure, Power Lines & Heat 6.5 Hoisting & Lift Equipment, Fire Prevention, PPE, Barricades, Debris & Recycling

7 Chapter 7: Planning, Structure & Estimating

7.1 Roof Types, Framing Terminology & Structural Loads 7.2 Pre-Job Walk-Through, Plans & Details, Permits & Selecting the Roof System 7.3 Roof Geometry, Slope, Pitch & Slope Factors for Measuring Roofs 7.4 Material Takeoffs: Squares, Bundles, Waste, Underlayment, Ice Barrier, Metals & Fasteners 7.5 Labor, Subcontractor & Access Costs and Preparing the Estimate

8 Chapter 8: Tear-Off, Deck Preparation & Underlayment

8.1 Roof Sheathing: Panel Grades, Spans, Edge Support & Nailing 8.2 Tear-Off vs. Recover, Reroofing Rules & Preparing the Site (MRC R908) 8.3 Michigan's Ice Barrier Requirement: Coverage, Materials & Detailing (R905.1.2) 8.4 Underlayment: Standards, Application by Slope & Attachment (R905.1.1) 8.5 Roof & Ceiling Insulation, Vapor Retarders, Air Sealing & Unvented Assemblies

9 Chapter 9: Steep-Slope Roof Systems

9.1 Asphalt Shingles: Types, ASTM D3462, Wind Classes, Impact & Fire Ratings 9.2 Installing Asphalt Shingles: Starter, Exposure, Nailing, Steep Slopes & Caps 9.3 Valleys: Linings, Open Metal, Closed-Cut & Woven Valleys 9.4 Metal Roof Systems, Tile, Slate & Wood Shingles and Shakes

10 Chapter 10: Low-Slope Roof Systems & Drainage

10.1 Single-Ply Membranes: EPDM, TPO & PVC 10.2 Built-Up Roofing & Modified Bitumen: Materials, Application, Kettles & Torch Safety 10.3 Low-Slope Drainage: Positive Drainage, Roof Drains, Overflow Scuppers & Correcting Ponding

11 Chapter 11: Flashings, Transitions & Penetrations

11.1 Drip Edge & Roof-Edge Metals (R905.2.8.5 and R903.2) 11.2 Sidewalls, Headwalls, Kick-Outs, Counterflashing & Pitch Transitions 11.3 Chimneys & Crickets, Skylights, Pipes, Flues, Exhaust Vents & Solar

12 Chapter 12: Ventilation, Inspection & Repair

12.1 Attic Ventilation Requirements & Net Free Vent Area Calculations (MRC R806) 12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams 12.3 Roof Inspections, Leak Diagnosis, Repairs & Roofovers

12.2 Balanced Airflow, Vent Installation Practice & Preventing Ice Dams

Key Takeaways Explain This Topic AI

Air should enter low at the eaves and leave high near the ridge, so the upper vents must stay within the 40–50 percent share if the balanced 1/300 option is used.

Shingle and vent manufacturers generally say not to combine different exhaust vent types, such as a ridge vent with gable or box vents, on the same attic space, because one exhaust can pull air through the other.

Eave baffles keep air-permeable insulation from blocking the vents (N1102.2.3), and R806.3 requires a 1-inch space between insulation and sheathing at the vent.

Ice dams come from heat leaking into the attic, so the first fixes are air sealing and insulation to R-38 (zone 5A) or R-49 (zones 6A and 7), backed by ventilation.

The Michigan ice barrier protects the roof from meltwater that backs up behind an ice dam, but it does not stop the ice dam from forming.

Last updated: September 2026

How Attic Airflow Works

Attic ventilation depends on wind and the stack effect . Cooler outside air enters low, at the eave (intake) vents, absorbs heat and moisture, rises, and leaves through high (exhaust) vents near the ridge. For this to work:

Intake at the bottom and exhaust at the top , on each separate attic space (R806.1 requires cross ventilation for each separate space).

Enough intake: R806.2's balanced option caps upper vents at 50 percent of the required area. Many manufacturers recommend at least as much intake as exhaust. If exhaust is larger than intake, the exhaust vents may pull air from the house through ceiling leaks.

An open air path: insulation, blocking, or a closed soffit must not cut off the eave vents.

Don't Mix Exhaust Types

When two kinds of exhaust vents serve the same attic, such as a ridge vent and gable louvers or box vents , the higher or stronger one can pull its air through the other exhaust vent instead of from the soffits. Air then short-circuits across the top of the attic and leaves the lower attic unventilated. Weather can also enter through the vent acting as intake. Most shingle and vent manufacturers therefore say to use one type of exhaust per attic space. When adding a ridge vent, close off gable louvers and box vents on that attic space, as the manufacturer directs. This is industry practice rather than a written code rule, but R806.4 requires installation per the manufacturer's instructions.

  • Installing the Vents
  • Soffit and Eave Intake

Remove paint, blocking, or insulation that plugs existing soffit vents.

Install eave baffles (rafter vents) in every rafter bay with a vent. N1102.2.3 requires a baffle in vented attics with air-permeable insulation (such as blown fiberglass or cellulose) at the eave vents. It must keep an opening at least as large as the vent and extend over the top of the insulation. R806.3 requires at least a 1-inch air space between insulation and sheathing at the vent.

Where there is no soffit, use a vented drip edge or a roof-deck intake vent installed per its instructions, and confirm that the NFVA is enough.

Ridge Vents

Mark and cut the ridge slot to the width the manufacturer specifies on each side of the ridge. Stop the slot short of the gable ends and of hip or chimney intersections as directed. Do not cut rafters or the ridge board.

Install the vent, with its external baffle or filter, over the slot, and nail it with the longer nails the maker specifies to reach through the vent into the deck.

Cap it with ridge cap shingles made for that purpose, using the specified nail length.

In Michigan, choose a ridge vent with an external baffle or filter rated for wind-driven snow and rain. Snow infiltration is a common complaint with poorly baffled vents.

Static and Turbine Vents

Place them within 3 feet of the ridge so they count as upper vents.

Flash them like any penetration. The lower flange goes over the shingles below, and the shingles above cover the upper flange (R806.4 and R903).

Powered, Solar, and Whole-House Fans

Powered attic ventilators (PAVs) are not required by the MRC. A PAV lowers the attic pressure. If the ceiling leaks, it pulls conditioned air and moisture from the house into the attic, which raises energy use. In a tight or leaky house, that suction can also contribute to backdrafting of chimneys and atmospherically vented appliances. Many building scientists and shingle manufacturers discourage PAVs, and some shingle warranties say not to combine them with ridge vents. Seal the ceiling first if a PAV is used.

Solar attic fans have the same issues on a smaller scale.

Whole-house fans pull house air into the attic to cool the home. M1501.1 allows whole-house ventilation attic fans to discharge into the attic of a dwelling with a private attic. They need large attic vent area, often several times the normal NFVA, sized by the fan maker.

Wiring for fans is electrical work for a licensed electrical contractor, unless an exemption applies.

Ice Dams: Cause and Prevention

An ice dam forms when heat from the house warms the upper roof, snow melts, and the water refreezes at the colder eave overhang. Water then pools behind the ice and can back up under the shingles. Michigan's heavy snow makes ice dams common. Prevention works in this order:

Air seal the ceiling plane. Most attic heat and moisture arrive by air leakage through recessed lights, top plates, chimney and duct chases, plumbing and wiring holes, and attic hatches. N1102.2.4 requires attic hatches to be weatherstripped and insulated.

Insulate to at least R-38 in zone 5A and R-49 in zones 6A and 7 (Table N1102.1.1), keeping full depth over the wall plates where possible.

Ventilate with continuous soffit intake and ridge exhaust, so the roof deck stays close to outdoor temperature.

Exhaust fans must discharge outdoors , never into the attic (M1501.1 and M1507.2). Bath exhaust into an attic is a leading cause of attic frost.

Protect the roof anyway. The ice barrier required at Michigan eaves (Section 8.3) keeps backed-up water out of the building if an ice dam forms. It does not prevent the ice dam itself.

Dealing With an Existing Ice Dam

Don't chip at ice with axes or shovels, because that damages shingles. Professional removal uses low-pressure steam.

Roof rakes from the ground remove snow near the eaves.

Heat cables are a symptom treatment. Install listed cables per the maker, and leave the electrical work to the right trade.

Diagnose the cause in the attic, and recommend air sealing and insulation to the owner in writing.