Study guide
1.1 MoDNR Regulatory Framework & Operator Classification
Missouri Water and Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Missouri State Laws, Regulations & Operator Certification
1.1 MoDNR Regulatory Framework & Operator Classification 1.2 Operator Certification, Experience Requirements & Reciprocity 1.3 Certification Renewal, Continuing Education & Compliance 1.4 Federal & State Drinking Water & Clean Water Acts 1.5 Missouri Design Standards, Construction Permits & the Design Guides 1.6 Utility Management, Administration & Recordkeeping
2 Chapter 2: Water Sources, Hydrology & Raw Water Quality
2.1 Hydrologic Cycle, Groundwater & Surface Water Sources 2.2 Well Construction, Sanitary Protection & Groundwater Hydraulics 2.3 Physical, Chemical & Biological Characteristics of Raw Water 2.4 Water Chemistry Fundamentals for Operators
3 Chapter 3: Coagulation, Flocculation & Sedimentation Processes
3.1 Coagulation Principles & Chemical Additives 3.2 Flocculation Hydraulics & Floc Formation 3.3 Sedimentation Basin Design, Clarifiers & Solids Separation 3.4 Aeration, Taste & Odor Control 3.5 Jar Testing Procedure & Chemical Feed Equipment
4 Chapter 4: Granular Media Filtration & Membrane Technologies
4.1 Conventional Rapid Sand & Dual/Multi-Media Filtration 4.2 Filter Operations, Backwashing & Turbidity Optimization 4.3 Membrane Filtration: Microfiltration, Ultrafiltration, Nanofiltration & Reverse Osmosis
5 Chapter 5: Water Disinfection & Chemical Handling Safety
5.1 Chlorination Chemistry, Breakpoint & Residual Monitoring 5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV 5.3 Disinfection Byproducts & Regulatory Compliance 5.4 Chlorine Gas Safety, Storage & Emergency Containment 5.5 CT Values, Contact Time & Log Inactivation Compliance 5.6 Wastewater Effluent Disinfection & Dechlorination
6 Chapter 6: Softening, Stabilization, Iron/Manganese Removal & Fluoridation
6.1 Lime-Soda Ash Softening & Ion Exchange Demineralization 6.2 Iron and Manganese Removal Technologies 6.3 Corrosion Control, Lead & Copper Rule & Stabilization 6.4 Fluoridation Chemistry, Feed Equipment & Safety
7 Chapter 7: Water Distribution Systems & Infrastructure Operations
7.1 Distribution Piping, Main Installation & Appurtenances 7.2 Distribution Storage Facilities & Pressure Management 7.3 Valves, Fire Hydrants & Metering Systems 7.4 Cross-Connection Control & Backflow Prevention
8 Chapter 8: Wastewater Characteristics, Preliminary & Primary Treatment
8.1 Wastewater Characteristics, Flow Variations & Sampling 8.2 Preliminary Treatment: Screening, Grinding & Grit Removal 8.3 Primary Clarification & Sedimentation Operations
9 Chapter 9: Biological Wastewater Treatment & Secondary Processes
9.1 Activated Sludge Fundamentals & Microbiology 9.2 Activated Sludge Process Control & Operational Parameters 9.3 Activated Sludge Variations: Extended Aeration, Oxidation Ditches & SBRs 9.4 Fixed-Film Processes & Waste Stabilization Ponds
10 Chapter 10: Advanced Wastewater Treatment, Nutrient Removal & Sludge Management
10.1 Biological & Chemical Phosphorus Removal 10.2 Biological Nitrogen Removal: Nitrification & Denitrification 10.3 Sludge Thickening, Stabilization & Digestion 10.4 Biosolids Dewatering, Land Application & 40 CFR Part 503 10.5 Thermal Solids Reduction & Sewage Sludge Incineration
11 Chapter 11: Wastewater Collection Systems & Lift Station Maintenance
11.1 Gravity Sewer Design, Hydraulics & Inflow/Infiltration 11.2 Lift Stations, Pumps & Level Control Systems 11.3 Collection System Operation, Cleaning & Inspection
12 Chapter 12: Water & Wastewater Laboratory Methods, Process Math & Safety
12.1 Water & Wastewater Laboratory Procedures & QA/QC 12.2 Applied Math: Pounds Formula, Chemical Feed & Flow Conversions 12.3 Applied Math: Process Loading, Weir Rates, SVI & Sludge Age 12.4 Plant Safety, Confined Space Entry, Chemical Hazards & Emergency Protocols 12.5 Pumps, Motors, Electrical Controls & Flow Measurement
1.1 MoDNR Regulatory Framework & Operator Classification
Key Takeaways Explain This Topic AI
MoDNR enforces drinking water operator rules under 10 CSR 60-14 and wastewater operator rules under 10 CSR 20-9, authorized by RSMo Chapters 640 and 644.
Drinking water treatment facilities are classified by source water and treatment process, not population; the only numeric treatment threshold is 1.5 MGD of surface water capacity, which separates Level A from Level B.
Distribution systems are classified by population served: DS III above 10,000, DS II from 3,301 to 10,000, and DS I up to 3,300, with storage, blending and disinfection criteria able to raise the level.
Missouri wastewater plants are classified by a point total under 10 CSR 20-9: Level D is 25 points or less, Level C is 26 to 50, Level B is 51 to 70, and Level A is 71 or more.
The system owner must notify the department in writing within fifteen (15) calendar days after the chief operator is replaced.
Last updated: September 2026
The protection of Missouri's water resources and public health relies on a strict legal and administrative framework. The Missouri Department of Natural Resources (MoDNR) serves as the primary environmental regulatory agency in the state. Operating through its Division of Environmental Quality, MoDNR oversees the permitting, compliance monitoring, and operator licensing programs across thousands of public water supply systems and wastewater treatment works.
Two citizen commissions establish environmental policy, adopt formal rules, and adjudicate appeals in Missouri:
The Missouri Safe Drinking Water Commission , authorized under Revised Statutes of Missouri ( RSMo Chapter 640 ), establishes drinking water standards and rules codified in Title 10 of the Missouri Code of State Regulations, Division 60 ( 10 CSR 60 ).
The Missouri Clean Water Commission , authorized under RSMo Chapter 644 (the Missouri Clean Water Law), establishes water quality standards, wastewater discharge limits, and operating regulations codified in Title 10, Division 20 ( 10 CSR 20 ).
Within this administrative code, 10 CSR 60-14 governs the certification and classification of drinking water operators, while 10 CSR 20-9 establishes the certification and classification requirements for wastewater operators. +-----------------------------------------------------------------------------------------+
- | MISSOURI REGULATORY GOVERNANCE |
- +-----------------------------------------------------------------------------------------+
- | RSMo Chapter 640 (Drinking Water Law) | RSMo Chapter 644 (Clean Water Law) |
- | -> Safe Drinking Water Commission | -> Clean Water Commission |
- | -> 10 CSR 60-14 (Drinking Water Operators) | -> 10 CSR 20-9 (Wastewater Operators) |
- +-----------------------------------------------+-----------------------------------------+
- | MoDNR Water Protection Program |
- | (Permitting, Compliance, Inspections & Certification) |
- +-----------------------------------------------------------------------------------------+
- Drinking Water Facility Classification (10 CSR 60-14.010, Table 1)
Under 10 CSR 60-14 , a drinking water treatment facility is classified by its source water and the treatment processes it operates — not by the population it serves. The rule works as a checklist: you find every row in Table 1 that applies to the plant, and the highest level applicable to the system is the classification of the system . The operator certificate required for the chief operator matches that classification, with Level A highest and Level D lowest.
The single numeric threshold in the treatment table is a capacity figure, and it applies only to surface water:
Classification Source-water and treatment characteristics that trigger this level
Level A (highest) Surface water source with treatment facility capacity greater than 1.5 million gallons per day (MGD)
Level B Surface water source with capacity less than or equal to 1.5 MGD ; Ground Water Under the Direct Influence of surface water (GWUDI) ; ground water (not GWUDI) with capacity greater than 1.5 MGD performing lime softening ; coagulation of surface water ; chlorine dioxide ; reverse osmosis, membrane filtration, ultrafiltration
Level C Gas chlorination using one-ton containers ; chemical oxidation (for example potassium permanganate); coagulation of groundwater ; ion exchange for purposes other than softening (such as nitrate removal); lime/soda softening ; pH and alkalinity adjustment ; adsorption (for example activated carbon); filtration (greensand, pressure, rapid gravity, slow sand)
Level D Ultraviolet light ; gas chlorination, calcium or sodium hypochlorination in combination with other treatment other than ion exchange softening; chloramines ; fluoridation ; sequestration ; aeration (cascade, diffused, packed tower, slat tray, spray); purchased water with further treatment by the purchasing system other than chlorination or ion exchange softening; ground water (not GWUDI) with treatment other than chlorination or ion exchange softening
Two rules catch candidates out repeatedly:
Ion exchange for softening is included in all treatment and distribution certifications. It never sets the level by itself; the level is determined by the plant's other treatment or distribution characteristics.
A system using only chlorination or ion exchange softening on ground water (not GWUDI) or purchased water, or using no treatment at all , is classified from the distribution table (Table 2) instead of the treatment table.
Worked example. A plant draws from a reservoir, runs coagulation, flocculation, sedimentation and dual-media filtration, and treats 6 MGD. Surface water above 1.5 MGD is a Level A row, so the plant is Level A and needs a Level A chief operator — the answer comes from the source and capacity , not from the 40,000 people it happens to serve.
Distribution System Classification (10 CSR 60-14.010, Table 2)
Distribution systems are classified DS I through DS III , with DS III highest. Here population is a criterion, and the same "highest applicable row wins" logic applies:
- Criterion Trigger Classification
- Population served by distribution Greater than 10,000 DS III
- 3,301 to 10,000 DS II
- Up to 3,300 DS I
Distribution source water Multiple sources — distributed water is blended from more than one treatment facility, well or purchased source, and the finished waters differ substantially in chemical characteristics DS III
- System storage Multiple gravity storage facilities DS II
- Two or more pressure reducing valves (excluding those on customer service lines) DS II
- Disinfection Gas chlorination is the only distribution system treatment DS II
- Calcium or sodium hypochlorite is the only distribution system treatment DS I
- Water in the distribution system from a surface water source is re-chlorinated DS III
Note the asymmetry the exam likes to test: gas chlorination in the distribution system pushes you to DS II, while hypochlorite only reaches DS I — the hazard of the chemical, not the disinfection itself, drives the level.
Wastewater Facility Classification: The Point System (10 CSR 20-9.010)
Missouri classifies wastewater treatment facilities completely differently from drinking water plants. Instead of a "highest row wins" table, 10 CSR 20-9 assigns points for every item that applies and totals them. The point total sets the classification:
- Classification Point total
- Level D 25 points and less
- Level C 26 to 50 points
- Level B 51 to 70 points
- Level A (highest) 71 points and greater
Selected point values operators are expected to recognise:
- Category Item Points
- Size Maximum population equivalent (P.E.) served, peak day 1 pt per 10,000 P.E. (max 10)
- Size Design flow or peak month's flow, whichever is larger 1 pt per MGD (max 10)
- Effluent discharge Missouri or Mississippi River 0
- Effluent discharge All other stream discharges except losing streams / whole-body-contact reaches 1
- Effluent discharge Losing stream, lake or reservoir supporting whole body contact recreation 3
- Effluent discharge Direct reuse or recycle of effluent 6
- Preliminary Screening and/or comminution; grit removal; plant pumping of main flow 3 each
- Preliminary Flow equalization 5
- Primary Primary clarifiers 5
- Secondary Activated sludge (incl. extended aeration, oxidation ditches, SBRs, MBRs, contact stabilization) 15
- Secondary Trickling filter and other fixed-film media 10
- Secondary Stabilization ponds without aeration 5
- Secondary Aerated lagoon 8
- Secondary Advanced lagoon treatment (aerobic cells, anaerobic cells, covers, fixed film) 10
- Solids Anaerobic digestion 10
- Solids Aerobic digestion 6
- Solids Mechanical dewatering 8
- Solids Solids reduction (incineration, wet oxidation) 12
- Disinfection Chlorination or comparable 5
- Disinfection Ultraviolet light 4
- Laboratory Advanced determinations (BOD seeding, fecal coliform, nutrients) 7
- Laboratory Highly sophisticated instrumentation (atomic absorption, gas chromatograph) 10
Worked example. A 2 MGD plant serving 18,000 P.E. discharging to an ordinary stream, with screening (3), grit removal (3), primary clarifiers (5), activated sludge (15), aerobic digestion (6), mechanical dewatering (8), chlorination (5) and BOD/DO/titration lab work (5): size 2 + 2 = 4, discharge 1, unit processes 45, lab 5 → 55 points → Level B . Adding anaerobic digestion (10) instead of aerobic (6) would push the total to 59 — still B; adding incineration (12) would carry it past 71 into Level A .
The rule also gives the department discretion: if unique treatment plant conditions distort the point total, the department may adjust the facility classification.
Staffing Mandates: Chief Operator and Process Control Decisions
Missouri requires clear lines of operational responsibility. Every permitted drinking water system and wastewater treatment facility must designate a qualified chief operator .
Certification rule: the chief operator must hold an active certificate of the appropriate type at a level equal to or higher than the facility's classification. A Level A surface water plant needs a Level A drinking water treatment operator as chief operator.
Vacancy notification: under 10 CSR 60-14.010(4) , the system owner shall notify the department in writing within fifteen (15) calendar days after the chief operator is replaced. This deadline is a favourite exam item — it is fifteen calendar days, not thirty, and not "the next monthly report".
Contract operators: a water system that hires a contract operator must have a written agreement setting out the operator's responsibilities, containing at minimum the information required by 10 CSR 60-14.010(4)(F).
Responsibilities: establishing standard operating procedures, supervising staff, reviewing and signing Monthly Operating Reports (MORs) and Discharge Monitoring Reports (DMRs), coordinating with MoDNR inspectors, and directing process optimisation.
Process control decisions and uncertified personnel
A process control decision is a judgement that directly changes water quality or effluent quality — adjusting coagulant or disinfectant dosing, changing filter backwash intervals, altering return activated sludge (RAS) or waste activated sludge (WAS) rates, or shifting hydraulic flows between unit processes. Missouri's experience rules define qualifying experience in exactly these terms: making or acting upon day-to-day process control and system integrity decisions , including the subsequent adjustment of chemical feeders.
Non-certified personnel — labourers, maintenance technicians, clerks, operators-in-training — may perform mechanical maintenance, read meters, pull samples and log data. They may not independently make process control decisions or alter chemical feed rates without the direction of a certified operator.