Study guide
4.3 Membrane Filtration: Microfiltration, Ultrafiltration, Nanofiltration & Reverse Osmosis
Missouri Water and Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Missouri State Laws, Regulations & Operator Certification
1.1 MoDNR Regulatory Framework & Operator Classification 1.2 Operator Certification, Experience Requirements & Reciprocity 1.3 Certification Renewal, Continuing Education & Compliance 1.4 Federal & State Drinking Water & Clean Water Acts 1.5 Missouri Design Standards, Construction Permits & the Design Guides 1.6 Utility Management, Administration & Recordkeeping
2 Chapter 2: Water Sources, Hydrology & Raw Water Quality
2.1 Hydrologic Cycle, Groundwater & Surface Water Sources 2.2 Well Construction, Sanitary Protection & Groundwater Hydraulics 2.3 Physical, Chemical & Biological Characteristics of Raw Water 2.4 Water Chemistry Fundamentals for Operators
3 Chapter 3: Coagulation, Flocculation & Sedimentation Processes
3.1 Coagulation Principles & Chemical Additives 3.2 Flocculation Hydraulics & Floc Formation 3.3 Sedimentation Basin Design, Clarifiers & Solids Separation 3.4 Aeration, Taste & Odor Control 3.5 Jar Testing Procedure & Chemical Feed Equipment
4 Chapter 4: Granular Media Filtration & Membrane Technologies
4.1 Conventional Rapid Sand & Dual/Multi-Media Filtration 4.2 Filter Operations, Backwashing & Turbidity Optimization 4.3 Membrane Filtration: Microfiltration, Ultrafiltration, Nanofiltration & Reverse Osmosis
5 Chapter 5: Water Disinfection & Chemical Handling Safety
5.1 Chlorination Chemistry, Breakpoint & Residual Monitoring 5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV 5.3 Disinfection Byproducts & Regulatory Compliance 5.4 Chlorine Gas Safety, Storage & Emergency Containment 5.5 CT Values, Contact Time & Log Inactivation Compliance 5.6 Wastewater Effluent Disinfection & Dechlorination
6 Chapter 6: Softening, Stabilization, Iron/Manganese Removal & Fluoridation
6.1 Lime-Soda Ash Softening & Ion Exchange Demineralization 6.2 Iron and Manganese Removal Technologies 6.3 Corrosion Control, Lead & Copper Rule & Stabilization 6.4 Fluoridation Chemistry, Feed Equipment & Safety
7 Chapter 7: Water Distribution Systems & Infrastructure Operations
7.1 Distribution Piping, Main Installation & Appurtenances 7.2 Distribution Storage Facilities & Pressure Management 7.3 Valves, Fire Hydrants & Metering Systems 7.4 Cross-Connection Control & Backflow Prevention
8 Chapter 8: Wastewater Characteristics, Preliminary & Primary Treatment
8.1 Wastewater Characteristics, Flow Variations & Sampling 8.2 Preliminary Treatment: Screening, Grinding & Grit Removal 8.3 Primary Clarification & Sedimentation Operations
9 Chapter 9: Biological Wastewater Treatment & Secondary Processes
9.1 Activated Sludge Fundamentals & Microbiology 9.2 Activated Sludge Process Control & Operational Parameters 9.3 Activated Sludge Variations: Extended Aeration, Oxidation Ditches & SBRs 9.4 Fixed-Film Processes & Waste Stabilization Ponds
10 Chapter 10: Advanced Wastewater Treatment, Nutrient Removal & Sludge Management
10.1 Biological & Chemical Phosphorus Removal 10.2 Biological Nitrogen Removal: Nitrification & Denitrification 10.3 Sludge Thickening, Stabilization & Digestion 10.4 Biosolids Dewatering, Land Application & 40 CFR Part 503 10.5 Thermal Solids Reduction & Sewage Sludge Incineration
11 Chapter 11: Wastewater Collection Systems & Lift Station Maintenance
11.1 Gravity Sewer Design, Hydraulics & Inflow/Infiltration 11.2 Lift Stations, Pumps & Level Control Systems 11.3 Collection System Operation, Cleaning & Inspection
12 Chapter 12: Water & Wastewater Laboratory Methods, Process Math & Safety
12.1 Water & Wastewater Laboratory Procedures & QA/QC 12.2 Applied Math: Pounds Formula, Chemical Feed & Flow Conversions 12.3 Applied Math: Process Loading, Weir Rates, SVI & Sludge Age 12.4 Plant Safety, Confined Space Entry, Chemical Hazards & Emergency Protocols 12.5 Pumps, Motors, Electrical Controls & Flow Measurement
4.3 Membrane Filtration: Microfiltration, Ultrafiltration, Nanofiltration & Reverse Osmosis
Key Takeaways Explain This Topic AI
Membrane processes differ by separation range: MF removes suspended solids, protozoa and bacteria; UF also rejects smaller colloids and may remove viruses, but organism credit must be demonstrated; NF rejects many divalent ions and organics; RO rejects a broad range of dissolved salts.
Operating flux is expressed in gallons per square foot per day (GFD), and transmembrane pressure is commonly calculated as the average feed-channel pressure minus permeate pressure.
Dead-end MF/UF sends feed through the membrane between backwashes, while cross-flow NF/RO maintains tangential concentrate flow to limit concentration polarization.
Backwash and manufacturer-approved chemical cleaning restore permeability; select acid, alkaline, chelant, oxidant or biocide chemistry from the identified foulant and membrane compatibility limits.
Under LT2, removal credit is the lower of challenge-test performance and what the operating direct-integrity test can verify. Direct testing is normally daily, continuous indirect monitoring runs between tests, and control limits come from the approved membrane protocol—not a universal pressure-decay number.
Last updated: September 2026
Membrane Separation Spectrum and Classifications
Membrane filtration utilizes semipermeable synthetic barriers to physically separate dissolved and suspended constituents from water under an applied pressure differential. In modern drinking water treatment, membrane technologies can provide a compact, directly testable particulate-pathogen barrier. Performance depends on membrane selection, pretreatment, integrity and operation; no membrane should be described as an infallible barrier.
Membrane processes are classified into four distinct operational regimes based on nominal pore diameter, Molecular Weight Cut-Off ( MWCO , measured in Daltons, Da \text{Da} Da ), and operating pressure:
Membrane Classification Nominal Pore Size MWCO Range Operating Pressure Target Contaminants Removed Typical Applications
Microfiltration (MF) 0.1 to 1.0 μ m 0.1\text{ to }1.0\text{ }\mu\text{m} 0.1 to 1.0 μ m > 100 , 000 Da > 100,000\text{ Da} > 100 , 000 Da 3 to 30 psi 3\text{ to }30\text{ psi} 3 to 30 psi ( 0.2 – 2.0 bar 0.2\text{--}2.0\text{ bar} 0.2 – 2.0 bar ) Suspended solids, turbidity, protozoan cysts ( Cryptosporidium , Giardia ), bacteria ( E. coli , Legionella ). (Does not reliably remove viruses) . Surface water clarification, pre-treatment to RO, secondary effluent polishing.
Ultrafiltration (UF) 0.01 to 0.1 μ m 0.01\text{ to }0.1\text{ }\mu\text{m} 0.01 to 0.1 μ m 1 , 000 to 100 , 000 Da 1,000\text{ to }100,000\text{ Da} 1 , 000 to 100 , 000 Da 10 to 50 psi 10\text{ to }50\text{ psi} 10 to 50 psi ( 0.7 – 3.5 bar 0.7\text{--}3.5\text{ bar} 0.7 – 3.5 bar ) MF targets plus smaller colloids and macromolecules; virus removal varies with product, water quality and operating conditions and must be demonstrated. Surface-water particulate-pathogen barrier and direct filtration; regulatory credit is validated, not inferred from nominal pore size.
Nanofiltration (NF) (Membrane Softening) 0.001 to 0.01 μ m 0.001\text{ to }0.01\text{ }\mu\text{m} 0.001 to 0.01 μ m ( 1 – 10 nm 1\text{--}10\text{ nm} 1 – 10 nm ) 200 to 1 , 000 Da 200\text{ to }1,000\text{ Da} 200 to 1 , 000 Da 50 to 250 psi 50\text{ to }250\text{ psi} 50 to 250 psi ( 3.5 – 17 bar 3.5\text{--}17\text{ bar} 3.5 – 17 bar ) Divalent ions ( C a 2 + , M g 2 + , S O 4 2 − Ca^{2+}, Mg^{2+}, SO_4^{2-} C a 2 + , M g 2 + , S O 4 2 − ), total organic carbon (TOC), DBP precursors (THM/HAA precursors), PFAS/PFOS, pesticides, micro-pollutants. Groundwater softening and rejection of color, organics and selected PFAS; the membrane separates contaminants into concentrate rather than destroying them.
Reverse Osmosis (RO) (Hyperfiltration) < 0.001 μ m < 0.001\text{ }\mu\text{m} < 0.001 μ m ( < 1 nm < 1\text{ nm} < 1 nm ) (Dense polymer matrix) < 200 Da < 200\text{ Da} < 200 Da 150 to 1 , 000 + psi 150\text{ to }1,000+\text{ psi} 150 to 1 , 000 + psi ( 10 – 70 bar 10\text{--}70\text{ bar} 10 – 70 bar ) Monovalent ions ( N a + , C l − Na^+, Cl^- N a + , C l − ), TDS, nitrates, heavy metals (arsenic, lead), radionuclides, many dissolved organic solutes, with rejection governed by membrane and solute properties. Brackish water and seawater desalination, advanced water reuse, TDS reduction.
Loading diagram... Membrane Separation Spectrum and Target Contaminant Rejection
- Flow Regimes and Module Configurations
- 1. Hydraulic Flow Configurations
Dead-End Filtration : 100 % 100\% 100% of feed water is driven perpendicular through the membrane barrier, converting the entire volume into filtrate (permeate). Retained solids accumulate directly on the membrane surface as a cake layer. Dead-end mode is energy-efficient and standard for low-pressure hollow-fiber MF/UF, relying on periodic automated air-water backwashes every 15 to 60 minutes 15\text{ to }60\text{ minutes} 15 to 60 minutes .
Cross-Flow (Tangential) Filtration : Feed water is pumped tangentially across the membrane surface at high velocity. The feed stream splits into two streams: purified permeate ( 75 % to 85 % 75\%\text{ to }85\% 75% to 85% ) that passes through the membrane, and a concentrated reject (concentrate/brine) stream ( 15 % to 25 % 15\%\text{ to }25\% 15% to 25% ) that sweeps accumulated solutes away from the membrane face. Cross-flow is the usual NF/RO configuration used to control concentration polarization and carry rejected solutes to the concentrate stream.
2. Physical Module Designs
Hollow-Fiber Modules : Bundles of thousands of microscopic hollow polymer capillaries (PVDF, PES, or polysulfone) potted in resin. Water flows either outside-in (feed on outer shell, filtrate drawn from inner lumen; easy to clean, handles high solids) or inside-out (feed pumped through lumen; uniform hydraulics). Hollow fibers are fully backwashable and dominate municipal MF/UF surface water plants.
Spiral-Wound Elements : Flat-sheet membrane envelopes separated by porous permeate carriers and mesh feed spacers wound around a central perforated permeate collection tube. Spiral-wound elements provide exceptionally high surface area packing density but cannot be hydraulically backwashed (solids lodge in mesh spacers). Standard for NF and RO.
3. Vacuum-Immersed vs. Pressure-Driven Skid Vessels
Vacuum-Driven (Immersed / Submerged) : Hollow-fiber membrane cassettes are submerged directly in open concrete process tanks. Permeate is drawn inward through fiber walls under negative pressure (vacuum of − 3 to − 12 psig -3\text{ to }-12\text{ psig} − 3 to − 12 psig ) generated by suction pumps. Allows direct visual inspection, coarse aeration for scouring, and lower operating energy.
Pressure-Driven Skids : Membrane modules are enclosed in cylindrical fiberglass reinforced plastic (FRP) pressure vessels mounted on skids. High-pressure pumps drive feed water into vessels at 30 to 1 , 000 psig 30\text{ to }1,000\text{ psig} 30 to 1 , 000 psig .
Key Membrane Operating Parameters and Hydraulic Calculations
Plant operators monitor membrane health, hydraulic productivity, and fouling rates using standardized parameters:
1. Membrane Flux ( J J J )
Flux is the volumetric filtration rate of permeate produced per unit of active membrane surface area, expressed in gallons per square foot per day (GFD) or liters per square meter per hour (LMH): J = Q p A m J = \frac{Q_p}{A_m} J = A m Q p
Where:
- Q p Q_p Q p = Permeate flow rate (Gallons per Day, GPD)
- A m A_m A m = Total active membrane surface area ( ft 2 \text{ft}^2 ft 2 )
Typical Design Values : 20 to 45 GFD 20\text{ to }45\text{ GFD} 20 to 45 GFD for low-pressure MF/UF; 10 to 20 GFD 10\text{ to }20\text{ GFD} 10 to 20 GFD for NF/RO.
2. Transmembrane Pressure (TMP)
Transmembrane Pressure (TMP) represents the average net pressure differential driving water molecules across the membrane barrier: TMP = ( P i n l e t + P o u t l e t 2 ) − P f i l t r a t e \text{TMP} = \left( \frac{P_{inlet} + P_{outlet}}{2} \right) - P_{filtrate} TMP = ( 2 P in l e t + P o u tl e t ) − P f i lt r a t e
Where:
- P i n l e t P_{inlet} P in l e t = Feed pressure at module inlet (psig)
- P o u t l e t P_{outlet} P o u tl e t = Concentrate pressure at module outlet (psig)
- P f i l t r a t e P_{filtrate} P f i lt r a t e = Permeate pressure on clean side (psig)
For vacuum immersed membranes: TMP = P b a s i n _ s t a t i c − P p e r m e a t e _ v a c u u m \text{TMP} = P_{basin\_static} - P_{permeate\_vacuum} TMP = P ba s in _ s t a t i c − P p er m e a t e _ v a c uu m .
3. Temperature Correction and Specific Flux
Because water viscosity increases by approximately 2.5 % for every 1 ∘ C 2.5\%\text{ for every }1^\circ\text{C} 2.5% for every 1 ∘ C drop in water temperature , measured flux must be normalized to standard temperature ( 20 ∘ C 20^\circ\text{C} 2 0 ∘ C or 25 ∘ C 25^\circ\text{C} 2 5 ∘ C ) to distinguish temperature-induced resistance from true chemical fouling: J 20 ∘ C = J T × ( μ T μ 20 ∘ C ) J_{20^\circ\text{C}} = J_T \times \left( \frac{\mu_T}{\mu_{20^\circ\text{C}}} \right) J 2 0 ∘ C = J T × ( μ 2 0 ∘ C μ T ) Specific Flux = Normalized Flux (GFD) TMP (psi) \text{Specific Flux} = \frac{\text{Normalized Flux (GFD)}}{\text{TMP (psi)}} Specific Flux = TMP (psi) Normalized Flux (GFD)
Trend temperature-normalized permeability or specific flux against the manufacturer’s and facility’s approved cleaning trigger; a fixed percentage decline is not universal.
4. Recovery Rate ( R R R ) and Concentration Factor ( C F CF CF ) % Recovery = ( Q p e r m e a t e Q f e e d ) × 100 % \%\text{ Recovery} = \left( \frac{Q_{permeate}}{Q_{feed}} \right) \times 100\% % Recovery = ( Q f ee d Q p er m e a t e ) × 100% Concentration Factor (CF) = 1 1 − ( Recovery / 100 ) \text{Concentration Factor (CF)} = \frac{1}{1 - (\text{Recovery}/100)} Concentration Factor (CF) = 1 − ( Recovery /100 ) 1
Example : A nanofiltration system operating at 80 % 80\% 80% recovery ( R = 0.80 R = 0.80 R = 0.80 ) concentrates rejected minerals by a factor of C F = 1 / ( 1 − 0.80 ) = 5.0 × CF = 1 / (1 - 0.80) = 5.0\times CF = 1/ ( 1 − 0.80 ) = 5.0 × in the brine stream.
Membrane Fouling Pathology and Clean-in-Place (CIP) Regimes
Membrane fouling increases TMP, drives up energy consumption, and degrades permeate quality. Fouling is classified into four operational categories:
Particulate / Colloidal Fouling : Clays, silts, and metal hydroxides forming a cake layer on membrane surfaces.
Organic Fouling : Adsorption of natural organic matter (NOM), humic and fulvic acids, biopolymers, and proteins onto polymer pores.
Mineral Scaling : Precipitation of sparingly soluble salts ( C a C O 3 , C a S O 4 , B a S O 4 , S r S O 4 CaCO_3, CaSO_4, BaSO_4, SrSO_4 C a C O 3 , C a S O 4 , B a S O 4 , S r S O 4 , and silica S i O 2 SiO_2 S i O 2 ) exceeding their solubility limits in the concentrate stream of NF/RO units.
Biofouling : Attachment and growth of living bacterial biofilms and secretion of extracellular polymeric substances (EPS).
Clean-in-Place (CIP) Chemical Protocols
When standard backwashes or maintenance washes fail to restore permeability, a full Clean-in-Place (CIP) may be required. The table gives representative chemistries—not universal recipes. Operators must follow the membrane manufacturer’s approved concentration, pH, temperature, exposure-time, neutralization and waste-disposal limits:
Fouling Class Targeted Scale / Foulant Primary CIP Chemical Cleaning Agents Cleaning Mechanism & Conditions
Inorganic Scale / Metals Calcium carbonate ( C a C O 3 CaCO_3 C a C O 3 ), iron/manganese oxides, metal hydroxides. Low-pH Acid Solution : 1.0 % to 2.0 % 1.0\%\text{ to }2.0\% 1.0% to 2.0% Citric acid or Hydrochloric acid ( H C l HCl H Cl ), p H ≈ 2.0 to 2.5 pH\approx 2.0\text{ to }2.5 p H ≈ 2.0 to 2.5 . Acid dissolves mineral scale and solubilizes multivalent metal ions. Recirculated at 35 – 40 ∘ C 35\text{--}40^\circ\text{C} 35 – 4 0 ∘ C for 1 to 2 hours followed by soak.
Organic / NOM Fouling Humic/fulvic acids, oils, grease, polysaccharides, natural organics. High-pH Alkaline Solution : Sodium hydroxide ( N a O H NaOH N a O H ), p H ≈ 11.0 to 12.0 pH\approx 11.0\text{ to }12.0 p H ≈ 11.0 to 12.0 , combined with surfactants (SDS) or EDTA chelating agents. Saponifies fatty organics, hydrolyzes biopolymers, and imparts negative electrical charges that repel organics off membrane surfaces.
Biofouling & Biofilm Microbial slime, algae, bacterial cell masses. Oxidizing Biocidal Wash : Sodium hypochlorite ( N a O C l NaOCl N a OCl , 100 – 1 , 000 mg/L 100\text{--}1,000\text{ mg/L} 100 – 1 , 000 mg/L free chlorine) or Hydrogen Peroxide / Peracetic Acid. Oxidizes bacterial cell walls and lyses EPS matrix. (Note: Standard polyamide NF/RO membranes cannot tolerate chlorine; use non-oxidizing biocides such as DBNPA or isothiazolin).
Colloidal Silica Amorphous polymerized silica scale ( S i O 2 SiO_2 S i O 2 ). Specialized high-pH ammonium bifluoride or caustic/EDTA cleaners at elevated temperature ( 40 ∘ C 40^\circ\text{C} 4 0 ∘ C ). Silica scale is extremely difficult to remove once crystallized; prevention via scale inhibitors (antiscalants) is essential.
Membrane Integrity Testing: Direct vs. Indirect Protocols
Under the EPA Long Term 2 Enhanced Surface Water Treatment Rule (LT2) , a membrane used for Cryptosporidium treatment credit receives the lower of (1) removal demonstrated by product-specific challenge testing or (2) the log-removal value the direct integrity test can verify during operation. The rule does not assign one default credit from membrane type or nominal pore size.
1. Direct Integrity Testing (High Sensitivity)
A qualifying direct integrity test must meet the approved resolution, sensitivity and frequency criteria. LT2 generally requires a resolution of 3 µm or smaller and testing at least once each day the membrane unit is in operation, although the state may approve less frequent testing under the rule’s reliability provisions:
Pressure Decay Test (PDT) : The isolated, wetted module is pressurized with clean air below the intact membrane’s bubble point, the source is isolated, and pressure loss is monitored for the approved test duration.
Pass/Fail criterion : An integral unit has little diffusive loss. Failure occurs when the measured decay exceeds the state- and manufacturer-approved control limit for that membrane unit and test setup ; 0.1–0.3 psi/min may appear in example protocols but is not an EPA-wide limit.
Resolution : Calculates the Log Removal Value ( LRV ) verified by the test: LRV = log 10 ( Q p × C f e e d Q b r e a c h × C f i l t r a t e ) \text{LRV} = \log_{10}\left(\frac{Q_p \times C_{feed}}{Q_{breach} \times C_{filtrate}}\right) LRV = lo g 10 ( Q b re a c h × C f i lt r a t e Q p × C f ee d )
Diffusive Air Flow Test : Measures the volumetric flow rate of air diffusing through wetted membranes at elevated test pressure.
Bubble Point Test : Determines the critical pressure required to force air through the largest wet pore ( P = 4 γ cos θ d P = \frac{4\gamma \cos\theta}{d} P = d 4 γ c o s θ ). Used to test flat-sheet integrity.
2. Indirect Integrity Monitoring (Continuous)
Online Permeate Turbidimetry : Continuous turbidimeters on each skid permeate header recording data every 15 minutes. Compare the signal with the approved indirect-integrity control limit and investigate a significant excursion; no single 0.05–0.10 NTU band applies to every membrane installation.
Laser Particle Counters : Measures particles in the 2 to 5 μ m 2\text{ to }5\text{ }\mu\text{m} 2 to 5 μ m range. A sudden spike in particle counts indicates a fiber break before turbidity rises.
3. Fiber Pinning and Repair
When a Pressure Decay Test fails, operators locate the compromised fiber using sonic acoustic detectors or sight-glass bubble inspection during low-pressure air injection. The damaged fiber is isolated or the module repaired using the manufacturer-approved method, which may include pinning or plugging both lumen ends. The unit must pass its direct integrity test before return to credited service.