5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV
Missouri Water and Wastewater Operator Certification Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Missouri State Laws, Regulations & Operator Certification
1.1 MoDNR Regulatory Framework & Operator Classification 1.2 Operator Certification, Experience Requirements & Reciprocity 1.3 Certification Renewal, Continuing Education & Compliance 1.4 Federal & State Drinking Water & Clean Water Acts 1.5 Missouri Design Standards, Construction Permits & the Design Guides 1.6 Utility Management, Administration & Recordkeeping
2 Chapter 2: Water Sources, Hydrology & Raw Water Quality
2.1 Hydrologic Cycle, Groundwater & Surface Water Sources 2.2 Well Construction, Sanitary Protection & Groundwater Hydraulics 2.3 Physical, Chemical & Biological Characteristics of Raw Water 2.4 Water Chemistry Fundamentals for Operators
3 Chapter 3: Coagulation, Flocculation & Sedimentation Processes
3.1 Coagulation Principles & Chemical Additives 3.2 Flocculation Hydraulics & Floc Formation 3.3 Sedimentation Basin Design, Clarifiers & Solids Separation 3.4 Aeration, Taste & Odor Control 3.5 Jar Testing Procedure & Chemical Feed Equipment
4 Chapter 4: Granular Media Filtration & Membrane Technologies
4.1 Conventional Rapid Sand & Dual/Multi-Media Filtration 4.2 Filter Operations, Backwashing & Turbidity Optimization 4.3 Membrane Filtration: Microfiltration, Ultrafiltration, Nanofiltration & Reverse Osmosis
5 Chapter 5: Water Disinfection & Chemical Handling Safety
5.1 Chlorination Chemistry, Breakpoint & Residual Monitoring 5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV 5.3 Disinfection Byproducts & Regulatory Compliance 5.4 Chlorine Gas Safety, Storage & Emergency Containment 5.5 CT Values, Contact Time & Log Inactivation Compliance 5.6 Wastewater Effluent Disinfection & Dechlorination
6 Chapter 6: Softening, Stabilization, Iron/Manganese Removal & Fluoridation
6.1 Lime-Soda Ash Softening & Ion Exchange Demineralization 6.2 Iron and Manganese Removal Technologies 6.3 Corrosion Control, Lead & Copper Rule & Stabilization 6.4 Fluoridation Chemistry, Feed Equipment & Safety
7 Chapter 7: Water Distribution Systems & Infrastructure Operations
7.1 Distribution Piping, Main Installation & Appurtenances 7.2 Distribution Storage Facilities & Pressure Management 7.3 Valves, Fire Hydrants & Metering Systems 7.4 Cross-Connection Control & Backflow Prevention
8 Chapter 8: Wastewater Characteristics, Preliminary & Primary Treatment
8.1 Wastewater Characteristics, Flow Variations & Sampling 8.2 Preliminary Treatment: Screening, Grinding & Grit Removal 8.3 Primary Clarification & Sedimentation Operations
9 Chapter 9: Biological Wastewater Treatment & Secondary Processes
9.1 Activated Sludge Fundamentals & Microbiology 9.2 Activated Sludge Process Control & Operational Parameters 9.3 Activated Sludge Variations: Extended Aeration, Oxidation Ditches & SBRs 9.4 Fixed-Film Processes & Waste Stabilization Ponds
10 Chapter 10: Advanced Wastewater Treatment, Nutrient Removal & Sludge Management
10.1 Biological & Chemical Phosphorus Removal 10.2 Biological Nitrogen Removal: Nitrification & Denitrification 10.3 Sludge Thickening, Stabilization & Digestion 10.4 Biosolids Dewatering, Land Application & 40 CFR Part 503 10.5 Thermal Solids Reduction & Sewage Sludge Incineration
11 Chapter 11: Wastewater Collection Systems & Lift Station Maintenance
11.1 Gravity Sewer Design, Hydraulics & Inflow/Infiltration 11.2 Lift Stations, Pumps & Level Control Systems 11.3 Collection System Operation, Cleaning & Inspection
12 Chapter 12: Water & Wastewater Laboratory Methods, Process Math & Safety
12.1 Water & Wastewater Laboratory Procedures & QA/QC 12.2 Applied Math: Pounds Formula, Chemical Feed & Flow Conversions 12.3 Applied Math: Process Loading, Weir Rates, SVI & Sludge Age 12.4 Plant Safety, Confined Space Entry, Chemical Hazards & Emergency Protocols 12.5 Pumps, Motors, Electrical Controls & Flow Measurement
5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV
Key Takeaways Explain This Topic AI
Monochloramine is produced by controlled chlorine and ammonia addition; ratios near 4.5:1 to 5:1 Cl2:NH3-N are common starting points, but the approved system-specific control target governs.
Nitrification is assessed from trends such as falling chloramine residual and dissolved oxygen, rising nitrite or nitrate, pH/alkalinity loss, and biological activity rather than from one universal trigger.
Chlorine dioxide is generated on site and can limit formation of regulated TTHMs and HAA5, but its 0.8 mg/L MRDL, 1.0 mg/L chlorite MCL, and required monitoring still apply.
Ozone is a powerful site-generated oxidant that can inactivate protozoa and viruses, forms bromate when bromide is present, and does not provide a lasting distribution residual.
UV damages microbial nucleic acids without creating a disinfectant residual; regulatory credit depends on validated reactor performance at the operating flow, UV transmittance, lamp status, and sensor conditions.
Last updated: September 2026
5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV
While free chlorine remains the most common municipal disinfectant, stringent regulatory limits on disinfection byproducts (DBPs) —such as trihalomethanes and haloacetic acids—along with chlorine's relative ineffectiveness against protozoan pathogens like Cryptosporidium , have led many utilities to implement alternative disinfection technologies.
Water utilities frequently employ a multi-barrier disinfection strategy , combining a high-potency primary disinfectant (such as ozone, UV, or free chlorine) at the treatment plant to achieve rapid pathogen log-inactivation, followed by a persistent secondary disinfectant (such as chloramines or free chlorine) to safeguard the distribution network.
Chloramination: Chemistry, Dosing Ratios & Distribution Persistence
Chloramines are chemical compounds formed by intentionally reacting chlorine with ammonia in treated water. Chloramines serve almost exclusively as a secondary disinfectant in long, complex distribution systems.
The Chloramination Reaction & Dosing Ratios
Chlorine and ammonia are added under controlled conditions to favor monochloramine (NH2Cl):
NH3 + HOCl → NH2Cl + H2O
Control target: Many utilities operate near 4.5:1 to 5:1 Cl2:NH3-N by weight , but this is a common operating range, not a universal setpoint. Feed strengths, pH, temperature, demand, contact sequence, distribution behavior, and the approved operating plan determine the target.
Too little chlorine: Can leave excess free ammonia that supports nitrification and weakens residual control.
Too much chlorine: Can move the reaction toward breakpoint and free-chlorine conditions; off-ratio operation may also increase taste-and-odor complaints.
Operator method: Verify both chlorine and ammonia feeds, calculate the ratio on an ammonia-nitrogen basis, and trend monochloramine, free ammonia, nitrite, nitrate, pH, alkalinity, dissolved oxygen, temperature, and water age.
Advantages and Limitations of Chloramines
Operational Advantages Critical Limitations
Extended Persistence : Often decays more slowly than free chlorine under comparable conditions, although water age, demand, temperature and biofilm still control the actual residual. Weak Primary Disinfectant : Significantly slower pathogen kill rates; requires 50 to 100 times higher CT values than free chlorine to inactivate Giardia . Ineffective against Cryptosporidium .
Lower regulated chlorinated DBPs : Usually forms less TTHM and HAA5 than free chlorine, but operators must still monitor the regulated DBPs and consider other chloramine-related byproducts. Dialysis Toxicity : Chloramines are toxic to kidney dialysis patients because they pass through dialysis membranes into the bloodstream, oxidizing hemoglobin into methemoglobin. Dialysis clinics must install carbon adsorption filters.
Biofilm Penetration : Penetrates deeper into thick distribution pipe biofilms than free chlorine due to slower reactivity. Aquatic Toxicity : Highly lethal to tropical fish and amphibians in home aquariums; requires chemical dechlorination with sodium thiosulfate.
Distribution System Nitrification: Mechanics & Control
The greatest operational hazard in chloraminated distribution networks is nitrification —a two-step biological oxidation of excess unreacted free ammonia carried out by autotrophic nitrifying bacteria:
Step 1: Ammonia Oxidation (by Nitrosomonas bacteria): 2 NH 3 + 3 O 2 → Nitrosomonas 2 NO 2 − (Nitrite) + 2 H + + 2 H 2 O 2\text{NH}_3 + 3\text{O}_2 \xrightarrow{\text{Nitrosomonas}} 2\text{NO}_2^- \text{ (Nitrite)} + 2\text{H}^+ + 2\text{H}_2\text{O} 2 NH 3 + 3 O 2 Nitrosomonas 2 NO 2 − (Nitrite) + 2 H + + 2 H 2 O
Step 2: Nitrite Oxidation (by Nitrobacter bacteria): 2 NO 2 − + O 2 → Nitrobacter 2 NO 3 − (Nitrate) 2\text{NO}_2^- + \text{O}_2 \xrightarrow{\text{Nitrobacter}} 2\text{NO}_3^- \text{ (Nitrate)} 2 NO 2 − + O 2 Nitrobacter 2 NO 3 − (Nitrate)
Warning Signs of a Nitrification Episode
No single measurement proves nitrification. Operators look for a pattern : falling total-chlorine or monochloramine residual, rising nitrite or nitrate above the system baseline, decreasing dissolved oxygen, pH or alkalinity loss, warmer water, and increased biological activity. Each utility establishes action levels from its own history and approved nitrification-control plan.
Nitrification Mitigation Strategies
Reduce water age through approved storage operation and targeted flushing.
Verify chlorine and ammonia feed calibration and reduce uncontrolled free-ammonia carryover.
Increase monitoring frequency and map the affected area before choosing a response.
If the approved plan calls for a temporary free-chlorine conversion, coordinate dose, duration, DBP monitoring, public communication, sensitive-customer protection and return to chloramines with the primacy agency. A fixed annual frequency or duration is not universal.
Chlorine Dioxide (ClO₂): Generation, Oxidation & Chlorite Control
Chlorine dioxide ( ClO 2 \text{ClO}_2 ClO 2 ) is a synthetic, dark reddish-yellow gas with a sharp, pungent odor. Unlike chlorine gas, chlorine dioxide does not hydrolyze in water ; it dissolves purely as a dissolved neutral gas molecule, maintaining full oxidation strength across a wide pH range ( pH 6.0 to 10.0 ). ┌───────────────────────────────────────────────────────────────┐
- │ CHLORINE DIOXIDE ONSITE GENERATION │
- │ 2 NaClO2 + Cl2 (g) ──► 2 ClO2 (aq) + 2 NaCl │
- │ Sodium Chlorite + Chlorine Gas ──► Chlorine Dioxide │
- └───────────────────────────────────────────────────────────────┘
- Chemical Properties and Generation
Because concentrated chlorine dioxide gas is unstable and violently explosive at partial pressures above 10 % in air 10\%\text{ in air} 10% in air ( > 76 mm Hg >76\text{ mm Hg} > 76 mm Hg ), ClO 2 \text{ClO}_2 ClO 2 cannot be compressed, liquefied, or shipped in commercial cylinders . It must always be generated on-site at the water plant at the moment of application.
Generation Method : Generated by reacting sodium chlorite solution ( NaClO 2 \text{NaClO}_2 NaClO 2 , 25 % – 31 % 25\%–31\% 25%–31% ) with chlorine gas or hydrochloric acid ( HCl \text{HCl} HCl ) inside a specialized vacuum-driven generation chamber.
Oxidation Characteristics : Highly selective oxidant. Extremely effective at oxidizing dissolved iron ( Fe 2 + \text{Fe}^{2+} Fe 2 + ) and manganese ( Mn 2 + \text{Mn}^{2+} Mn 2 + ), destroying phenolic taste and odor compounds, and neutralizing geosmin and 2-methylisoborneol (MIB) produced by cyanobacteria.
DBP Advantage : Does not chlorinate organic matter . It does not form regulated trihalomethanes (TTHMs) or haloacetic acids (HAA5).
Regulatory Byproduct Limits & Monitoring
When chlorine dioxide oxidizes contaminants, it is reduced primarily to chlorite ( ClO 2 − \text{ClO}_2^- ClO 2 − ) and to a lesser extent chlorate ( ClO 3 − \text{ClO}_3^- ClO 3 − ): ClO 2 + e − ⟶ ClO 2 − ( Chlorite Ion Formation ) \text{ClO}_2 + e^- \longrightarrow \text{ClO}_2^- \quad (\text{Chlorite Ion Formation}) ClO 2 + e − ⟶ ClO 2 − ( Chlorite Ion Formation )
Chlorite Maximum Contaminant Level (MCL) : 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L . Chlorite induces hemolytic anemia and methemoglobinemia in sensitive populations.
Maximum Residual Disinfectant Level (MRDL) : 0.8 mg/L 0.8\text{ mg/L} 0.8 mg/L for ClO 2 \text{ClO}_2 ClO 2 .
Monitoring Rules : Operators must test for chlorine dioxide and chlorite daily at the plant point of entry (POE) . If entry chlorite exceeds 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L , the utility must collect a 3-sample distribution set (near first customer, middle, and maximum residence point) within 24 hours.
Ozone (O₃): Strong Oxidant, Corona Discharge & Bromate Formation
Ozone ( O 3 \text{O}_3 O 3 ) is an allotrope of oxygen consisting of three oxygen atoms. It is one of the most powerful chemical oxidants known in water treatment (Oxidation Potential E ∘ = 2.07 V E^\circ = 2.07\text{ V} E ∘ = 2.07 V , compared to 1.36 V 1.36\text{ V} 1.36 V for chlorine gas). OZONE GENERATION & OFF-GAS CYCLE
- ┌─────────────────┐ ┌─────────────────┐ ┌─────────────────┐
- │ Clean, Dry Air │ │ High-Voltage │ │ Ozone Contactor │
- │ or Pure Oxygen │ ────► │ Corona Discharge│ ────► │ (Deep Bubble │
- │ (Dew Point <-60)│ │ Dielectric Cell │ │ Diffusion Tank)│
- └─────────────────┘ └─────────────────┘ └────────┬────────┘
- │ Off-Gas
- ▼
- ┌─────────────────┐
- │ Thermal/Catalyt.│
- │ Ozone Destructor│
- │ (Converts O3->O2)│
- └─────────────────┘
- Generation and Contactor Architecture
Site Generation via Corona Discharge : Ozone is unstable and is generated on site from conditioned dry air or oxygen using a high-voltage corona-discharge generator. The manufacturer and approved design establish feed-gas quality and electrical operating limits.
Contactor and credit : Diffusers or injectors transfer ozone into a contactor. Pathogen inactivation credit depends on the approved contactor hydraulics, ozone residual profile, temperature and demonstrated operating conditions, not on one universal basin depth or CT claim.
Off-gas and worker safety : Collected off-gas is routed through an approved thermal, catalytic or thermal-catalytic destruction system and ambient ozone is monitored. OSHA’s permissible exposure limit is 0.1 ppm as an 8-hour time-weighted average , not an absolute instantaneous ceiling; the facility alarm and response plan may use a more protective setpoint.
The Bromate Hazard
When ozone is applied to raw water containing naturally occurring dissolved bromide ( Br − \text{Br}^- Br − ), ozone oxidizes bromide to bromate ( BrO 3 − \text{BrO}_3^- BrO 3 − ), a potent human carcinogen: Br − + O 3 ⟶ OBr − → O 3 BrO 3 − ( Bromate Formation ) \text{Br}^- + \text{O}_3 \longrightarrow \text{OBr}^- \xrightarrow{\text{O}_3} \text{BrO}_3^- \quad (\text{Bromate Formation}) Br − + O 3 ⟶ OBr − O 3 BrO 3 − ( Bromate Formation )
Bromate MCL : 0.010 mg/L 0.010\text{ mg/L} 0.010 mg/L ( 10 μ g/L 10\ \mu\text{g/L} 10 μ g/L ) .
Bromate control : Dose, contact conditions, pH, ammonia addition and other controls can affect formation; the plant selects controls from source-water testing, treatment objectives and its approved process.
No lasting distribution residual : Ozone decays rapidly and is not relied on to protect the distribution system. A system must maintain the secondary disinfectant required by its approved treatment and distribution plan.
Ultraviolet (UV) Disinfection: Photochemical Inactivation & Maintenance
Ultraviolet (UV) disinfection is a physical, non-chemical treatment process that exposes water to electromagnetic radiation in the UV-C spectrum (wavelengths 200 – 280 nm 200–280\text{ nm} 200–280 nm ). Microbial DNA Strands: ... — [ Thymine ] ════ [ Thymine ] — ...
- ▲ ▲
- │ UV-C │
- │ (254 nm) │
- │ │
- Irradiated DNA Strand: ... — [ Thymine ─── Thymine ] — ... (Thymine Dimer Formed)
- (Replication Blocked -> Pathogen Inactivated)
- Germicidal Mechanism: Thymine Dimerization
Peak Germicidal Wavelength : Maximum absorption by microbial nucleic acids occurs at 254 – 260 nm 254–260\text{ nm} 254–260 nm .
Photochemical Disruption : UV photons absorbed by microbial DNA and RNA create pyrimidine photoproducts that disrupt replication and transcription. Cyclobutane thymine dimers are a familiar DNA example; RNA contains uracil rather than thymine.
Loss of Infectivity : The nucleic-acid damage prevents successful replication while the organism may remain physically intact.
Protozoan efficacy and validation : UV can be highly effective against chlorine-resistant protozoa, but regulatory log-inactivation credit comes from the validated reactor dose and the approved operating envelope rather than from a single generic dose.
Key Operational Parameters & Maintenance
UV Transmittance (%UVT) : The percentage of 254-nm light transmitted through the stated path length. Lower UVT means less light reaches organisms; the validated operating limit, not a universal 80% cutoff, controls reactor operation.
Lamp Sleeve Fouling : Low-Pressure High-Output (LPHO) and Medium-Pressure (MP) mercury lamps are housed in transparent fused quartz sleeves . Over time, calcium, magnesium hardness, and iron precipitate onto the hot quartz surface, creating an opaque mineral scale that blocks UV transmission.
Sleeve Cleaning Protocols : Systems operate automated mechanical wipers coupled with periodic offline chemical soaking using mild acid solutions (typically citric acid or phosphoric acid) to strip mineral scale.
Duty Sensors : Calibrated germicidal UV sensors continuously monitor irradiance ( W / m 2 W/m^2 W / m 2 ) to verify delivered UV dose ( mJ/cm 2 = Irradiance × Exposure Time \text{mJ/cm}^2 = \text{Irradiance} \times \text{Exposure Time} mJ/cm 2 = Irradiance × Exposure Time ).