Study guide

6.2 Iron and Manganese Removal Technologies

Missouri Water and Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Missouri State Laws, Regulations & Operator Certification

1.1 MoDNR Regulatory Framework & Operator Classification 1.2 Operator Certification, Experience Requirements & Reciprocity 1.3 Certification Renewal, Continuing Education & Compliance 1.4 Federal & State Drinking Water & Clean Water Acts 1.5 Missouri Design Standards, Construction Permits & the Design Guides 1.6 Utility Management, Administration & Recordkeeping

2 Chapter 2: Water Sources, Hydrology & Raw Water Quality

2.1 Hydrologic Cycle, Groundwater & Surface Water Sources 2.2 Well Construction, Sanitary Protection & Groundwater Hydraulics 2.3 Physical, Chemical & Biological Characteristics of Raw Water 2.4 Water Chemistry Fundamentals for Operators

3 Chapter 3: Coagulation, Flocculation & Sedimentation Processes

3.1 Coagulation Principles & Chemical Additives 3.2 Flocculation Hydraulics & Floc Formation 3.3 Sedimentation Basin Design, Clarifiers & Solids Separation 3.4 Aeration, Taste & Odor Control 3.5 Jar Testing Procedure & Chemical Feed Equipment

4 Chapter 4: Granular Media Filtration & Membrane Technologies

4.1 Conventional Rapid Sand & Dual/Multi-Media Filtration 4.2 Filter Operations, Backwashing & Turbidity Optimization 4.3 Membrane Filtration: Microfiltration, Ultrafiltration, Nanofiltration & Reverse Osmosis

5 Chapter 5: Water Disinfection & Chemical Handling Safety

5.1 Chlorination Chemistry, Breakpoint & Residual Monitoring 5.2 Alternative Disinfectants: Chloramines, Chlorine Dioxide, Ozone & UV 5.3 Disinfection Byproducts & Regulatory Compliance 5.4 Chlorine Gas Safety, Storage & Emergency Containment 5.5 CT Values, Contact Time & Log Inactivation Compliance 5.6 Wastewater Effluent Disinfection & Dechlorination

6 Chapter 6: Softening, Stabilization, Iron/Manganese Removal & Fluoridation

6.1 Lime-Soda Ash Softening & Ion Exchange Demineralization 6.2 Iron and Manganese Removal Technologies 6.3 Corrosion Control, Lead & Copper Rule & Stabilization 6.4 Fluoridation Chemistry, Feed Equipment & Safety

7 Chapter 7: Water Distribution Systems & Infrastructure Operations

7.1 Distribution Piping, Main Installation & Appurtenances 7.2 Distribution Storage Facilities & Pressure Management 7.3 Valves, Fire Hydrants & Metering Systems 7.4 Cross-Connection Control & Backflow Prevention

8 Chapter 8: Wastewater Characteristics, Preliminary & Primary Treatment

8.1 Wastewater Characteristics, Flow Variations & Sampling 8.2 Preliminary Treatment: Screening, Grinding & Grit Removal 8.3 Primary Clarification & Sedimentation Operations

9 Chapter 9: Biological Wastewater Treatment & Secondary Processes

9.1 Activated Sludge Fundamentals & Microbiology 9.2 Activated Sludge Process Control & Operational Parameters 9.3 Activated Sludge Variations: Extended Aeration, Oxidation Ditches & SBRs 9.4 Fixed-Film Processes & Waste Stabilization Ponds

10 Chapter 10: Advanced Wastewater Treatment, Nutrient Removal & Sludge Management

10.1 Biological & Chemical Phosphorus Removal 10.2 Biological Nitrogen Removal: Nitrification & Denitrification 10.3 Sludge Thickening, Stabilization & Digestion 10.4 Biosolids Dewatering, Land Application & 40 CFR Part 503 10.5 Thermal Solids Reduction & Sewage Sludge Incineration

11 Chapter 11: Wastewater Collection Systems & Lift Station Maintenance

11.1 Gravity Sewer Design, Hydraulics & Inflow/Infiltration 11.2 Lift Stations, Pumps & Level Control Systems 11.3 Collection System Operation, Cleaning & Inspection

12 Chapter 12: Water & Wastewater Laboratory Methods, Process Math & Safety

12.1 Water & Wastewater Laboratory Procedures & QA/QC 12.2 Applied Math: Pounds Formula, Chemical Feed & Flow Conversions 12.3 Applied Math: Process Loading, Weir Rates, SVI & Sludge Age 12.4 Plant Safety, Confined Space Entry, Chemical Hazards & Emergency Protocols 12.5 Pumps, Motors, Electrical Controls & Flow Measurement

6.2 Iron and Manganese Removal Technologies

Key Takeaways Explain This Topic AI

EPA Secondary Maximum Contaminant Levels (SMCLs) establish non-enforceable aesthetic thresholds for iron at 0.3 mg/L (red/brown staining) and manganese at 0.05 mg/L (black staining).

Iron and manganese exist in anaerobic groundwater in soluble reduced forms (ferrous Fe2+ and manganous Mn2+) that must be oxidized into insoluble precipitates (ferric hydroxide Fe(OH)3 and manganese dioxide MnO2) prior to media filtration.

Aeration supplies dissolved oxygen to oxidize ferrous iron at pH 7.0–7.5 (0.14 mg O2 per 1.0 mg Fe2+), but atmospheric oxygen oxidizes manganese very slowly unless the pH exceeds 9.5.

Potassium permanganate (KMnO4) rapidly oxidizes both iron (0.94 mg KMnO4 per mg Fe2+) and manganese (1.92 mg KMnO4 per mg Mn2+), but overfeeding must be avoided to prevent pink or purple finished water.

Manganese greensand filters utilize Continuous Regeneration (CR) with permanganate feed for iron-dominant waters or Intermittent Regeneration (IR) for manganese-dominant waters.

Last updated: September 2026

6.2 Iron and Manganese Removal Technologies

Iron ( Fe \text{Fe} Fe ) and manganese ( Mn \text{Mn} Mn ) are naturally occurring minerals abundant in the earth's crust. In deep groundwater aquifers and anoxic reservoir bottoms (hypolimnions) common throughout Missouri, anaerobic conditions and dissolved carbon dioxide dissolve these minerals into soluble, reduced divalent ionic states: ferrous iron ( Fe 2 + \text{Fe}^{2+} Fe 2 + ) and manganous manganese ( Mn 2 + \text{Mn}^{2+} Mn 2 + ) .

While iron and manganese are not regulated under primary National Primary Drinking Water Regulations because they do not present acute toxicity at typical environmental levels, they create severe aesthetic, operational, and customer relations problems. When water containing soluble Fe 2 + \text{Fe}^{2+} Fe 2 + and Mn 2 + \text{Mn}^{2+} Mn 2 + is exposed to atmospheric oxygen or chlorine in distribution systems, the minerals oxidize into insoluble particles, causing stained laundry, discolored plumbing fixtures, metallic tastes, and heavy pipe deposits.

Secondary Standards & Operational Thresholds

The United States Environmental Protection Agency (EPA) and the Missouri Department of Natural Resources (MoDNR) have established Secondary Maximum Contaminant Levels (SMCLs) to manage aesthetic water quality:

Mineral Parameter Secondary MCL (SMCL) Ionic States (Reduced → \rightarrow → Oxidized) Aesthetic & Operational Impacts

Iron ( Fe \text{Fe} Fe ) 0.3 mg/L 0.3\text{ mg/L} 0.3 mg/L ( 300 μ g/L 300\text{ }\mu\text{g/L} 300 μ g/L ) Soluble Ferrous ( Fe 2 + \text{Fe}^{2+} Fe 2 + ) → \rightarrow → Insoluble Ferric ( Fe 3 + \text{Fe}^{3+} Fe 3 + ) Reddish-brown water; rust-colored staining of laundry, sinks, and bathtubs; metallic, astringent taste; sediment buildup.

Manganese ( Mn \text{Mn} Mn ) 0.05 mg/L 0.05\text{ mg/L} 0.05 mg/L ( 50 μ g/L 50\text{ }\mu\text{g/L} 50 μ g/L ) Soluble Manganous ( Mn 2 + \text{Mn}^{2+} Mn 2 + ) → \rightarrow → Insoluble Manganic ( Mn 4 + \text{Mn}^{4+} Mn 4 + ) Black to dark brown water; severe black staining of porcelain, clothing, and fixtures; bitter metallic taste; turbidity. +-----------------------------------------------------------------------------------------+

  • | IRON BACTERIA ISSUES |
  • +-----------------------------------------------------------------------------------------+
  • | - Genera: Gallionella, Crenothrix, Leptothrix, Sphaerotilus. |
  • | - Metabolism: Chemotrophic bacteria that oxidize soluble Fe2+ into insoluble Fe3+ |
  • | hydrated ferric oxide sheath matrices. |
  • | - Operational Problems: |
  • | 1. Massive gelatinous, slimy biomass clogs well screens, pumps, and distribution. |
  • | 2. Severe "rotten egg" (H2S), swamplike, or musty taste and odor complaints. |
  • | 3. Induces Microbially Influenced Corrosion (MIC), creating severe pipe pitting. |
  • | - Control Measures: Shock chlorination of wells (500 - 1000 mg/L free chlorine), |
  • | well acidification/surfactants, and maintaining a distribution chlorine residual. |
  • +-----------------------------------------------------------------------------------------+
  • Oxidation Chemistry: Converting Soluble Ions to Insoluble Precipitates

To remove iron and manganese, water treatment plants convert soluble Fe 2 + \text{Fe}^{2+} Fe 2 + and Mn 2 + \text{Mn}^{2+} Mn 2 + into insoluble ferric hydroxide ( Fe(OH) 3 \text{Fe(OH)}_3 Fe(OH) 3 ​ ) and manganese dioxide ( MnO 2 \text{MnO}_2 MnO 2 ​ ) precipitates that can be removed by depth or surface filtration: Soluble Ferrous Iron (Fe2+) ──[ Oxidation ]──► Insoluble Ferric Hydroxide (Fe(OH)3↓)

  • Soluble Manganous Manganese (Mn2+) ──[ Oxidation ]──► Insoluble Manganese Dioxide (MnO2↓)
  • 1. Aeration (Physical Atmospheric Oxidation)

Aeration introduces atmospheric oxygen ( O 2 \text{O}_2 O 2 ​ ) into raw water. It is highly effective and economical for iron oxidation, while simultaneously stripping dissolved gases like carbon dioxide ( CO 2 \text{CO}_2 CO 2 ​ , which raises pH) and hydrogen sulfide ( H 2 S \text{H}_2\text{S} H 2 ​ S , which removes rotten egg odors).

Iron Aeration Reaction : 4 Fe 2 + + O 2 + 10 H 2 O → 4 Fe(OH) 3 ↓ + 8 H + 4\text{Fe}^{2+} + \text{O}_2 + 10\text{H}_2\text{O} \rightarrow 4\text{Fe(OH)}_3\downarrow + 8\text{H}^+ 4 Fe 2 + + O 2 ​ + 10 H 2 ​ O → 4 Fe(OH) 3 ​ ↓ + 8 H +

Stoichiometric Oxygen Demand : 1.0 mg/L of Fe 2 + 1.0\text{ mg/L of Fe}^{2+} 1.0 mg/L of Fe 2 + requires 0.14 mg/L of dissolved oxygen (O 2 ) 0.14\text{ mg/L of dissolved oxygen (O}_2) 0.14 mg/L of dissolved oxygen (O 2 ​ ) .

Kinetics : Iron oxidation proceeds rapidly at pH 7.0 − 7.5 \text{pH } 7.0 - 7.5 pH 7.0 − 7.5 (reaction completes in 5 − 15 minutes 5 - 15\text{ minutes} 5 − 15 minutes ). Cold temperatures or low pH ( < 6.5 < 6.5 < 6.5 ) substantially retard reaction rates.

Manganese Aeration Limitation :

Dissolved oxygen reacts extremely slowly with manganous manganese ( Mn 2 + \text{Mn}^{2+} Mn 2 + ) at normal groundwater pH levels.

Direct aeration oxidation of Mn 2 + \text{Mn}^{2+} Mn 2 + requires a pH ≥ 9.5 \text{pH } \ge 9.5 pH ≥ 9.5 and reaction contact times exceeding 30 − 60 minutes 30 - 60\text{ minutes} 30 − 60 minutes , making aeration alone impractical for manganese removal.

Common Aerator Configurations

Cascade Aerators : Water flows downward over a series of concrete steps or baffles, creating thin liquid sheets that absorb oxygen.

Tray (Coke-Tray) Aerators : Water trickles through a vertical stack of perforated trays packed with coke, limestone, or ceramic media. The coke provides a high surface area and catalytic oxide coating that accelerates oxidation.

Draft / Induced-Draft Aerators : Enclosed vertical towers where water sprays downward while an electric blower forces air upward through plastic contact packing.

Diffused Bubble Aeration : Compressed air is bubbled through submerged porous diffusers in a contact basin.

2. Chemical Oxidation

When manganese is present, iron concentrations are elevated, or detention space is limited, utilities rely on strong chemical oxidants:

Potassium Permanganate ( KMnO 4 \text{KMnO}_4 KMnO 4 ​ )

Potassium permanganate is a dark purple crystalline chemical that dissolves to form a deep violet oxidant solution. It is widely considered the most effective chemical oxidant for both iron and manganese across a wide pH range ( 6.0 − 9.0 6.0 - 9.0 6.0 − 9.0 ).

Iron Oxidation by Permanganate : 3 Fe 2 + + KMnO 4 + 7 H 2 O → 3 Fe(OH) 3 ↓ + MnO 2 ↓ + K + + 5 H + 3\text{Fe}^{2+} + \text{KMnO}_4 + 7\text{H}_2\text{O} \rightarrow 3\text{Fe(OH)}_3\downarrow + \text{MnO}_2\downarrow + \text{K}^+ + 5\text{H}^+ 3 Fe 2 + + KMnO 4 ​ + 7 H 2 ​ O → 3 Fe(OH) 3 ​ ↓ + MnO 2 ​ ↓ + K + + 5 H +

Dosage Stoichiometry : 0.94 mg/L of KMnO 4 0.94\text{ mg/L of KMnO}_4 0.94 mg/L of KMnO 4 ​ per 1.0 mg/L of Fe 2 + 1.0\text{ mg/L of Fe}^{2+} 1.0 mg/L of Fe 2 + .

Manganese Oxidation by Permanganate : 3 Mn 2 + + 2 KMnO 4 + 2 H 2 O → 5 MnO 2 ↓ + 2 K + + 4 H + 3\text{Mn}^{2+} + 2\text{KMnO}_4 + 2\text{H}_2\text{O} \rightarrow 5\text{MnO}_2\downarrow + 2\text{K}^+ + 4\text{H}^+ 3 Mn 2 + + 2 KMnO 4 ​ + 2 H 2 ​ O → 5 MnO 2 ​ ↓ + 2 K + + 4 H +

Dosage Stoichiometry : 1.92 mg/L of KMnO 4 1.92\text{ mg/L of KMnO}_4 1.92 mg/L of KMnO 4 ​ per 1.0 mg/L of Mn 2 + 1.0\text{ mg/L of Mn}^{2+} 1.0 mg/L of Mn 2 + .

Theoretical Permanganate Demand Equation : KMnO 4 Demand (mg/L) = ( 0.94 × Fe 2 + mg/L ) + ( 1.92 × Mn 2 + mg/L ) \text{KMnO}_4\text{ Demand (mg/L)} = (0.94 \times \text{Fe}^{2+}\text{ mg/L}) + (1.92 \times \text{Mn}^{2+}\text{ mg/L}) KMnO 4 ​ Demand (mg/L) = ( 0.94 × Fe 2 + mg/L ) + ( 1.92 × Mn 2 + mg/L )

Caution

Overfeeding Hazard : Operators must calibrate permanganate feed pumps accurately. Overfeeding KMnO 4 \text{KMnO}_4 KMnO 4 ​ leaves unreacted permanganate in the finished water, producing a distinctive pink or purple color in the distribution system and generating widespread customer complaints.

Chlorine Oxidation ( Cl 2 \text{Cl}_2 Cl 2 ​ )

Free chlorine (gas or sodium hypochlorite NaOCl \text{NaOCl} NaOCl ) oxidizes iron and manganese according to:

Iron : 2 Fe 2 + + Cl 2 + 6 H 2 O → 2 Fe(OH) 3 ↓ + 2 Cl − + 6 H + 2\text{Fe}^{2+} + \text{Cl}_2 + 6\text{H}_2\text{O} \rightarrow 2\text{Fe(OH)}_3\downarrow + 2\text{Cl}^- + 6\text{H}^+ 2 Fe 2 + + Cl 2 ​ + 6 H 2 ​ O → 2 Fe(OH) 3 ​ ↓ + 2 Cl − + 6 H +

Stoichiometry: 0.64 mg/L Cl 2 0.64\text{ mg/L Cl}_2 0.64 mg/L Cl 2 ​ per 1.0 mg/L Fe 2 + 1.0\text{ mg/L Fe}^{2+} 1.0 mg/L Fe 2 + (completes in < 5 minutes < 5\text{ minutes} < 5 minutes at pH 6.5 − 7.5 \text{pH } 6.5 - 7.5 pH 6.5 − 7.5 ).

Manganese : Mn 2 + + Cl 2 + 2 H 2 O → MnO 2 ↓ + 2 Cl − + 4 H + \text{Mn}^{2+} + \text{Cl}_2 + 2\text{H}_2\text{O} \rightarrow \text{MnO}_2\downarrow + 2\text{Cl}^- + 4\text{H}^+ Mn 2 + + Cl 2 ​ + 2 H 2 ​ O → MnO 2 ​ ↓ + 2 Cl − + 4 H +

Stoichiometry: 1.29 mg/L Cl 2 1.29\text{ mg/L Cl}_2 1.29 mg/L Cl 2 ​ per 1.0 mg/L Mn 2 + 1.0\text{ mg/L Mn}^{2+} 1.0 mg/L Mn 2 + (requires elevated pH ≥ 8.0 − 8.5 \text{pH } \ge 8.0 - 8.5 pH ≥ 8.0 − 8.5 and 20 − 30 minutes 20 - 30\text{ minutes} 20 − 30 minutes contact time).

Caution: Adding high chlorine doses ahead of raw water containing Natural Organic Matter (NOM) accelerates Trihalomethane (THM) and Haloacetic Acid (HAA5) formation.

Catalytic Media Filtration Technologies

Following oxidation, precipitated ferric hydroxide and manganese dioxide must be filtered out. Most modern groundwater plants utilize specialized catalytic media beds: +-----------------------------------------------------------------------------------------+

  • | CATALYTIC FILTER MEDIA CHARACTERISTICS |
  • +-----------------------------------------------------------------------------------------+
  • | 1. Manganese Greensand (Glauconite): |
  • | - Natural mined glauconite sand coated with higher manganese oxides (MnO2). |
  • | - Bulk density: ~85 lb/cu ft. |
  • | - Catalytically oxidizes soluble Mn2+ and Fe2+ directly on contact. |
  • +-----------------------------------------------------------------------------------------+
  • | 2. GreensandPlus: |
  • | - Synthetic silica sand core with fused manganese dioxide coating. |
  • | - Operates at higher differential pressures and temperatures; tolerates low-TDS |
  • | and low-silica waters without glauconite core degradation. |
  • +-----------------------------------------------------------------------------------------+
  • | 3. Birm (Birm Media): |
  • | - Insoluble aluminum silicate coated with manganese dioxide. |
  • | - Acts strictly as an unregenerated catalyst for dissolved oxygen oxidation. |
  • | - Requires: DO >= 15% of Fe concentration, pH >= 6.8 (iron) or >= 8.0 (manganese). |
  • | - Cannot tolerate H2S, oil, polyphosphates, or residual chlorine (> 0.5 mg/L). |
  • +-----------------------------------------------------------------------------------------+
  • Operational Modes for Manganese Greensand

Continuous Regeneration (CR) :

Potassium permanganate (or chlorine plus a minor permanganate trim) is continuously fed into the raw water pipeline immediately upstream of the greensand filter.

The chemical oxidant precipitates the bulk of iron and manganese in the pipe/contact chamber, while the greensand media polishes remaining dissolved ions and acts as a buffer against oxidant underfeeding or overfeeding.

Application : Preferred when iron is high ( > 1.0 mg/L > 1.0\text{ mg/L} > 1.0 mg/L ) or iron exceeds manganese.

Intermittent Regeneration (IR) :

Raw water passes through the regenerated greensand bed without continuous chemical oxidant feed. The greensand media's active MnO 2 \text{MnO}_2 MnO 2 ​ coating directly oxidizes and adsorbs Fe 2 + \text{Fe}^{2+} Fe 2 + and Mn 2 + \text{Mn}^{2+} Mn 2 + .

When the media's oxidative adsorption capacity is exhausted (typically after treating 500 − 1 , 000 gallons per cu ft 500 - 1,000\text{ gallons per cu ft} 500 − 1 , 000 gallons per cu ft of media), the bed is backwashed and regenerated with a concentrated potassium permanganate solution ( 1.5 ounces of KMnO 4 per cubic foot of greensand 1.5\text{ ounces of KMnO}_4\text{ per cubic foot of greensand} 1.5 ounces of KMnO 4 ​ per cubic foot of greensand ).

Application : Preferred when manganese predominates and iron is low ( < 0.5 mg/L < 0.5\text{ mg/L} < 0.5 mg/L ).

Chemical Sequestration (Polyphosphates)

In small groundwater systems where iron and manganese concentrations are low, utilities may avoid installing filtration infrastructure by using sequestration .

Mechanism : Polyphosphate compounds (such as sodium hexametaphosphate, polyphosphate blends, or sodium silicates) are injected into the water. Polyphosphate molecules bind and chemically "wrap" around soluble Fe 2 + \text{Fe}^{2+} Fe 2 + and Mn 2 + \text{Mn}^{2+} Mn 2 + ions, forming stable soluble complexes that prevent them from reacting with oxygen or chlorine and precipitating.

Application Thresholds : Sequestration is only acceptable when combined iron and manganese concentrations are less than 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L , and manganese is ≤ 0.1 mg/L \le 0.1\text{ mg/L} ≤ 0.1 mg/L .

Critical Dosing Rule : Polyphosphate must ALWAYS be injected ahead of chlorine or aeration . If chlorine contacts the water first, it oxidizes the iron and manganese to insoluble Fe(OH) 3 \text{Fe(OH)}_3 Fe(OH) 3 ​ and MnO 2 \text{MnO}_2 MnO 2 ​ , which polyphosphates cannot sequester.

Loading diagram... Iron & Manganese Continuous Regeneration (CR) Greensand Filtration Train