Study guide

2.1 Thermodynamic Principles: Pressure, Temperature, Sensible vs. Latent Heat & Steam Tables

Montana Boiler Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Boiler Construction, Classifications & Mechanical Design

1.1 Fire-Tube Boiler Designs, Gas Passes & Operating Principles 1.2 Water-Tube Boilers, Circulation Loops & Pressure Capabilities 1.3 Cast-Iron Sectional, Scotch Marine, Packaged & Electric Boilers

2 Chapter 2: Normal Boiler Operations & Thermodynamic Fundamentals

2.1 Thermodynamic Principles: Pressure, Temperature, Sensible vs. Latent Heat & Steam Tables 2.2 Pre-Startup Inspection Protocols, Boiler Filling & Slow Warm-Up Curves 2.3 Bringing Boilers On-Line, Header Valving, Swell, Shrinkage & Carryover 2.4 Normal Shutdown, Banking & Securing a Boiler Off Line

3 Chapter 3: Auxiliary Pumping Systems, Valves & Steam Distribution

3.1 Boiler Feedwater Pumps, NPSH Requirements & Cavitation Prevention 3.2 Piping Specialties, Stop Valves, Check Valves & PRV Stations 3.3 Steam Traps (F&T, Inverted Bucket, Thermodynamic) & Condensate Return Systems

4 Chapter 4: Safety Relief Devices & Water Level Protection Systems

4.1 Safety Valves & Safety Relief Valves: ASME Standards, Relieving Capacity & Testing 4.2 Water Columns, Gauge Glasses, Try Cocks & Blowdown Protocols 4.3 Low-Water Fuel Cutoffs (Float vs. Probe), Redundancy & Testing Procedures 4.4 Operating Controls, Limit Controls, Gauges & Feedwater Regulators

5 Chapter 5: Fuels, Fuel Systems & Combustion Equipment

5.1 Fuel Oil Systems: Grades, Storage, Heating, Pumping & Atomization 5.2 Natural Gas & Propane Fuel Trains: Regulators, Valve Sequence & Gas Properties 5.3 Solid Fuels, Stokers, Burner Registers & Combustion Equipment

6 Chapter 6: Burner Management, Combustion Safeguards & Emergency Response

6.1 Burner Management Systems, Flame Scanners & Pre/Post-Purge Cycles 6.2 Combustion Controls, Firing Rate Modulation & Draft Systems 6.3 Emergency Procedures: Low Water, Furnace Explosions, Tube Ruptures & Gas Leaks 6.4 Instrumentation & Control Systems: Sensors, Transmitters, Controllers & Loops

7 Chapter 7: Feedwater Chemistry, Water Treatment & Combustion Efficiency

7.1 Boiler Water Impurities, Hardness Scale, Oxygen Pitting & Caustic Embrittlement 7.2 Feedwater Pretreatment, Deaeration, Chemical Scavengers & pH Control 7.3 Boiler Blowdown Dynamics (Bottom vs. Continuous) & Combustion Analysis

8 Chapter 8: Maintenance Routines, Inspections & System Preservation

8.1 Shift Routines, Operator Logbooks & Preventive Maintenance Schedules 8.2 Jurisdictional Inspections, Hydrostatic Pressure Testing & Tube/Refractory Care 8.3 Nameplate Data, ASME/NBIC Stamps & Boiler Layup (Wet vs. Dry)

9 Chapter 9: Hot-Water & Hydronic Boiler Systems

9.1 Hot Water Heating & Supply Boilers: Fittings, Controls & Relief Devices 9.2 Hydronic Accessories: Expansion Tanks, Circulators, Air Control & Zoning

10 Chapter 10: Cooling Systems & Boiler Room Safety

10.1 Cooling Systems: Refrigeration Principles, Chillers & Chilled-Water Loops 10.2 Boiler Room Safety: PPE, Confined Space, Lockout/Tagout & Hazard Control

11 Chapter 11: Montana Statutes, Administrative Rules & Licensing Compliance

11.1 MCA Title 50, Chapter 74: Jurisdiction, Exemptions & Operator Duties 11.2 The Six Engineer License Classes, the Traction License & Qualifying Experience 11.3 ARM 24.122: Application, Examination, Fees, Renewal & Discipline 11.4 Montana Inspections, Operating Certificates & Safe Working Pressure (MCA 50-74 Part 2)

2.1 Thermodynamic Principles: Pressure, Temperature, Sensible vs. Latent Heat & Steam Tables

Key Takeaways Explain This Topic AI

Sensible heat causes a direct temperature change in water (approximately 1.0 Btu/lb-°F), while latent heat of vaporization causes a phase change from liquid to vapor at constant saturation temperature.

At standard atmospheric pressure (14.696 psia or 0 psig), water boils at 212°F and absorbs 970.3 Btu/lb of latent heat of vaporization to transition into dry saturated steam.

As boiler operating pressure increases, the saturation temperature increases while the latent heat of vaporization (h_fg) decreases, reaching zero at the thermodynamic critical point of 3,206.2 psia and 705.4°F.

Absolute pressure (psia) equals gauge pressure (psig) plus atmospheric pressure (standard 14.7 psi at sea level); all thermodynamic steam property calculations must be referenced to psia.

One Boiler Horsepower (BHP) is defined as the evaporation of 34.5 lb of water/hr from and at 212°F (33,475 Btu/hr); the companion rule of thumb that 10 sq ft of heating surface equals one BHP is a traditional trade rating convention, not a definition written into Montana law.

Last updated: September 2026

2.1 Thermodynamic Principles: Pressure, Temperature, Sensible vs. Latent Heat & Steam Tables

Quick Technical Summary: Water inside a steam boiler undergoes two distinct thermal stages: sensible heating (raising liquid temperature by absorbing approximately 1.0 Btu/lb per °F) and latent heat of vaporization (absorbing thermal energy at constant saturation temperature to convert liquid water into vapor—specifically 970.3 Btu/lb at atmospheric pressure 14.7 psia / 0 psig). As operating pressure increases, the boiling temperature rises while the latent heat required to evaporate each pound of water decreases. Boiler Horsepower (BHP) is standardized as the evaporation of 34.5 pounds of water per hour from and at 212°F (33,475 Btu/hr), historically rated at 10 square feet of heating surface.

Operating a stationary steam boiler safely and efficiently requires a solid command of thermodynamics. A licensed boiler operator does not simply monitor gauges; they manage phase transitions, heat transfer rates, and massive stored energy reserves. In high-pressure and low-pressure systems alike, pressure and temperature are inextricably linked by physical laws governed by the properties of water and steam.

Fundamental Thermodynamic Units and Temperature Scales

Thermal energy in stationary engineering is quantified using the British Thermal Unit (Btu) .

Definition of a Btu: The amount of heat energy required to raise the temperature of 1 pound of pure water by 1 degree Fahrenheit at maximum density (standardized from 59°F to 60°F or 60°F to 61°F at standard atmospheric pressure).

Specific Heat Capacity ( c p c_p c p ​ ): The ratio of heat required to raise the temperature of a unit mass of a substance by 1 degree compared to water. For liquid water under standard boiler operating ranges, the specific heat is taken as c p = 1.0 Btu / ( lb ⋅ ∘ F ) c_p = 1.0 \text{ Btu}/(\text{lb}\cdot^\circ\text{F}) c p ​ = 1.0 Btu / ( lb ⋅ ∘ F ) .

Temperature is the measure of molecular kinetic intensity (thermal potential), whereas heat is the total thermal energy transferred. Operators must be comfortable converting between the two primary engineering temperature scales: Degrees Fahrenheit ( ∘ F ) = ( ∘ C × 1.8 ) + 32 \text{Degrees Fahrenheit } (^\circ\text{F}) = (^\circ\text{C} \times 1.8) + 32 Degrees Fahrenheit ( ∘ F ) = ( ∘ C × 1.8 ) + 32 Degrees Celsius ( ∘ C ) = ∘ F − 32 1.8 \text{Degrees Celsius } (^\circ\text{C}) = \frac{^\circ\text{F} - 32}{1.8} Degrees Celsius ( ∘ C ) = 1.8 ∘ F − 32 ​ Degrees Rankine (Absolute) = ∘ F + 459.67 \text{Degrees Rankine (Absolute)} = ^\circ\text{F} + 459.67 Degrees Rankine (Absolute) = ∘ F + 459.67

Pressure Fundamentals: Gauge vs. Absolute Pressure

Boiler pressure gauges display gauge pressure (psig) , which represents pressure exerted above local atmospheric pressure. However, all thermodynamic formulas, steam tables, and gas laws require absolute pressure (psia) .

Standard Atmospheric Pressure: At sea level, atmospheric air exerts a baseline pressure of 14.696 psi (commonly rounded to 14.7 psi) , equivalent to 29.92 inches of mercury (in. Hg) or 33.9 feet of water column .

Converting Gauge to Absolute Pressure: P psia = P psig + 14.7 P_{\text{psia}} = P_{\text{psig}} + 14.7 P psia ​ = P psig ​ + 14.7

For example, if a boiler steam drum gauge indicates 150 psig , the absolute pressure within the drum is: 150 psig + 14.7 psi = 164.7 psia 150 \text{ psig} + 14.7 \text{ psi} = 164.7 \text{ psia} 150 psig + 14.7 psi = 164.7 psia

Vacuum Measurement: Condensers and sub-atmospheric deaerators are calibrated in inches of mercury vacuum ( i n . Hg vac in. \text{ Hg vac} in . Hg vac ). To convert vacuum readings to absolute pressure: P psia = ( 29.92 − in. Hg vacuum ) × 0.491 P_{\text{psia}} = (29.92 - \text{in. Hg vacuum}) \times 0.491 P psia ​ = ( 29.92 − in. Hg vacuum ) × 0.491

An operator reading 24 in. Hg vacuum on a surface condenser calculates absolute pressure as ( 29.92 − 24 ) × 0.491 = 2.91 psia (29.92 - 24) \times 0.491 = 2.91 \text{ psia} ( 29.92 − 24 ) × 0.491 = 2.91 psia .

Sensible Heat vs. Latent Heat

Heat transferred into boiler water manifests as either sensible heat or latent heat, depending on whether a phase change occurs.

1. Sensible Heat ( h f h_f h f ​ )

Sensible heat is heat that causes a measurable change in temperature without changing the physical state (liquid, vapor, or solid) of the substance. It is called "sensible" because the change can be sensed by a thermometer or thermocouple.

The sensible heat added to liquid water is calculated as: Q s = m × c p × ( T 2 − T 1 ) Q_s = m \times c_p \times (T_2 - T_1) Q s ​ = m × c p ​ × ( T 2 ​ − T 1 ​ )

Where m m m is the mass in pounds, c p c_p c p ​ is 1.0 Btu / ( lb ⋅ ∘ F ) 1.0 \text{ Btu}/(\text{lb}\cdot^\circ\text{F}) 1.0 Btu / ( lb ⋅ ∘ F ) , and Δ T \Delta T Δ T is the temperature differential.

Thermodynamic Reference Baseline: In standard ASME steam tables, the baseline for sensible heat ( h f = 0.00 Btu/lb h_f = 0.00 \text{ Btu/lb} h f ​ = 0.00 Btu/lb ) is set at 32.0°F (0.0°C) for liquid water.

Sensible Heat to Boiling at Atmospheric Pressure: To heat 1 pound of water from 32°F to its atmospheric boiling point of 212°F requires: 1 lb × 1.0 Btu / ( lb ⋅ ∘ F ) × ( 212 ∘ F − 32 ∘ F ) = 180 Btu of sensible heat ( h f ) 1 \text{ lb} \times 1.0 \text{ Btu}/(\text{lb}\cdot^\circ\text{F}) \times (212^\circ\text{F} - 32^\circ\text{F}) = 180 \text{ Btu of sensible heat } (h_f) 1 lb × 1.0 Btu / ( lb ⋅ ∘ F ) × ( 21 2 ∘ F − 3 2 ∘ F ) = 180 Btu of sensible heat ( h f ​ )

2. Latent Heat

Latent heat is heat absorbed or released when a substance changes its physical state at constant temperature and pressure . No temperature change registers on a thermometer during latent heat transfer.

Latent Heat of Fusion: The heat absorbed to change 1 pound of ice at 32°F into liquid water at 32°F ( 144 Btu/lb ).

Latent Heat of Vaporization ( h f g h_{fg} h f g ​ ): The heat required to change 1 pound of saturated liquid water into 1 pound of saturated steam at the same boiling temperature. At standard atmospheric pressure (14.696 psia / 0 psig, boiling at 212°F), the latent heat of vaporization is exactly 970.3 Btu/lb .

Total Heat of Saturated Steam (Enthalpy, h g h_g h g ​ )

The total heat content (enthalpy) of dry saturated steam is the algebraic sum of the sensible heat of the liquid plus the latent heat of vaporization: h g = h f + h f g h_g = h_f + h_{fg} h g ​ = h f ​ + h f g ​

At atmospheric pressure (0 psig / 14.7 psia): h g = 180.1 Btu/lb + 970.3 Btu/lb = 1 , 150.4 Btu/lb h_g = 180.1 \text{ Btu/lb} + 970.3 \text{ Btu/lb} = 1,150.4 \text{ Btu/lb} h g ​ = 180.1 Btu/lb + 970.3 Btu/lb = 1 , 150.4 Btu/lb

More than 84% of the total energy contained in steam at 212°F resides in its latent heat of vaporization. This high latent energy density makes steam the premier industrial medium for heating, process energy, and power generation.

The Pressure-Temperature Saturation Relationship

Water does not boil at a fixed temperature; its boiling point depends entirely upon the absolute pressure exerted upon its surface. The temperature at which water boils at a given pressure is called the saturation temperature ( T sat T_{\text{sat}} T sat ​ ) .

Core Thermodynamic Rules for Boilers:

Saturation Temperature Rises with Pressure: As boiler operating pressure increases, the saturation boiling temperature increases. Water boils at 212°F at 0 psig, 298°F at 50 psig, 338°F at 100 psig, and 366°F at 150 psig.

Latent Heat Decreases as Pressure Rises: As pressure increases, molecules in the liquid state are forced closer together and already possess higher thermal agitation. Consequently, less latent energy is required to tear the liquid molecules apart into vapor. Latent heat of vaporization ( h f g h_{fg} h f g ​ ) decreases from 970.3 Btu/lb at 0 psig down to 857.0 Btu/lb at 150 psig, and 729.8 Btu/lb at 600 psig.

Specific Volume Shrinks Drastically: As pressure increases, steam vapor is compressed. One pound of dry saturated steam occupies 26.80 cubic feet at 0 psig, but shrinks to 2.75 cubic feet at 150 psig, and 0.74 cubic feet at 600 psig. Higher operating pressures allow smaller piping and equipment to transport equivalent thermal energy.

The Thermodynamic Critical Point: At an absolute pressure of 3,206.2 psia and a saturation temperature of 705.4°F , liquid water and dry steam reach identical densities ( 19.7 lb/ft 3 19.7 \text{ lb/ft}^3 19.7 lb/ft 3 ). At this critical point, the latent heat of vaporization drops to h f g = 0 Btu/lb h_{fg} = 0 \text{ Btu/lb} h f g ​ = 0 Btu/lb . Liquid water flashes instantaneously into steam without any boiling plateau or bubbling.

Steam Classifications: Wet, Dry Saturated, and Superheated

Boiler operators must distinguish between three distinct steam conditions:

Steam Classification Physical State Moisture Content Enthalpy Characteristics

Wet Steam Mixture of saturated vapor and suspended liquid droplets Contains > 0 % > 0\% > 0% liquid moisture h = h f + ( x ⋅ h f g ) h = h_f + (x \cdot h_{fg}) h = h f ​ + ( x ⋅ h f g ​ ) where x < 1.0 x < 1.0 x < 1.0

Dry Saturated Steam Pure vapor at saturation temperature ( T sat T_{\text{sat}} T sat ​ ) 0 % 0\% 0% moisture ( 100 % 100\% 100% vapor, quality x = 1.0 x = 1.0 x = 1.0 ) Contains full latent heat ( h g = h f + h f g h_g = h_f + h_{fg} h g ​ = h f ​ + h f g ​ )

Superheated Steam Pure vapor heated above saturation temperature at constant pressure Completely dry ( 0 % 0\% 0% moisture) h = h g + c p , steam ⋅ ( T actual − T sat ) h = h_g + c_{p,\text{steam}} \cdot (T_{\text{actual}} - T_{\text{sat}}) h = h g ​ + c p , steam ​ ⋅ ( T actual ​ − T sat ​ )

Steam Quality ( x x x )

Wet steam is quantified by its steam quality ( x x x ) , which represents the percentage by weight of dry vapor in the steam-water mixture: x = m dry vapor m total mixture × 100 % x = \frac{m_{\text{dry vapor}}}{m_{\text{total mixture}}} \times 100\% x = m total mixture ​ m dry vapor ​ ​ × 100%

If steam contains 3% entrained liquid water droplets, its quality is 97 % 97\% 97% ( x = 0.97 x = 0.97 x = 0.97 ). Wet steam reduces heat exchanger efficiency and causes severe erosion on high-speed turbine blades and piping elbows.

Superheated Steam

When dry saturated steam is piped out of the boiler drum and passed through a separate heat exchanger exposed to furnace flue gases (a superheater ), its temperature rises above saturation without an increase in pressure.

Degree of Superheat: The difference between actual steam temperature and saturation temperature: Superheat ( ∘ F ) = T actual − T sat \text{Superheat } (^\circ\text{F}) = T_{\text{actual}} - T_{\text{sat}} Superheat ( ∘ F ) = T actual ​ − T sat ​ .

Advantages: Superheated steam contains no moisture droplets, preventing blade erosion in steam turbines; it has higher thermodynamic cycle efficiency (Rankine cycle); and it can travel long distribution distances without premature condensation.

ASME Saturated Steam Table Reference

Understanding the numerical values in saturated steam tables is a core requirement of the Montana boiler operator licensing examination. Below is an extract of properties across typical commercial and industrial operating pressures:

Gauge Pressure (psig) Absolute Pressure (psia) Saturation Temp T sat T_{\text{sat}} T sat ​ (°F) Sensible Heat Liquid h f h_f h f ​ (Btu/lb) Latent Heat Vapor h f g h_{fg} h f g ​ (Btu/lb) Total Heat Vapor h g h_g h g ​ (Btu/lb) Specific Volume Vapor v g v_g v g ​ (ft³/lb)

  • 0.0 14.7 212.0 180.1 970.3 1,150.4 26.80
  • 15.0 29.7 249.8 218.5 945.7 1,164.2 13.75
  • 50.0 64.7 297.7 267.5 911.6 1,179.1 6.66
  • 100.0 114.7 337.9 309.0 880.6 1,189.6 3.88
  • 150.0 164.7 366.0 338.5 857.0 1,195.5 2.75
  • 200.0 214.7 387.9 362.0 837.4 1,199.4 2.14
  • 300.0 314.7 421.8 398.7 804.5 1,203.2 1.47
  • 600.0 614.7 488.9 474.7 729.8 1,204.5 0.74

Exam Key Insight: Observe how the latent heat ( h f g h_{fg} h f g ​ ) column steadily decreases from 970.3 Btu/lb at atmospheric pressure to 857.0 Btu/lb at 150 psig, while sensible heat ( h f h_f h f ​ ) increases from 180.1 Btu/lb to 338.5 Btu/lb . Total heat ( h g h_g h g ​ ) rises only slightly because the gain in sensible heat is largely offset by the loss in latent heat.

Boiler Horsepower (BHP) and Evaporation Ratings

Boiler capacity in stationary engineering is rated in pounds of steam generated per hour (lb/hr), MBtu/hr (million Btu per hour), or Boiler Horsepower (BHP) .

Historical Centennial Standard (1876)

At the 1876 Philadelphia Centennial Exhibition, one boiler horsepower was defined as the capacity to evaporate 30 pounds of water per hour from a feedwater temperature of 100°F into saturated steam at 70 psig . Under modern steam tables that duty works out to roughly 33,450 Btu/hr, close enough to the modern figure that the two ratings are treated as equivalent.

Modern Standard ASME / Licensing Definition

To establish an absolute baseline independent of feedwater temperature or steam pressure, Boiler Horsepower was redefined strictly "from and at 212°F": 1 Boiler Horsepower (BHP) = 34.5 lb of water evaporated per hour "from and at 212°F" \mathbf{1 \text{ Boiler Horsepower (BHP)} = 34.5 \text{ lb of water evaporated per hour "from and at 212°F"}} 1 Boiler Horsepower (BHP) = 34.5 lb of water evaporated per hour "from and at 212°F"

Since evaporating 1 pound of water from and at 212°F requires exactly the latent heat of vaporization at atmospheric pressure ( 970.3 Btu/lb 970.3 \text{ Btu/lb} 970.3 Btu/lb ), the equivalent heat output of one BHP is: BHP Thermal Equivalent = 34.5 lb/hr × 970.3 Btu/lb = 33 , 475.35 ≈ 33 , 475 Btu/hr (or 9.81 kW) \text{BHP Thermal Equivalent} = 34.5 \text{ lb/hr} \times 970.3 \text{ Btu/lb} = \mathbf{33,475.35 \approx 33,475 \text{ Btu/hr}} \text{ (or } 9.81 \text{ kW)} BHP Thermal Equivalent = 34.5 lb/hr × 970.3 Btu/lb = 33 , 475.35 ≈ 33 , 475 Btu/hr (or 9.81 kW)

Heating Surface Rating Convention

Before modern high-efficiency heat transfer designs and forced-draft combustion, boilers were rated based purely on their heating surface area.

Traditional Trade Rating Convention: For fire-tube and water-tube boilers, 10 square feet of heating surface has historically been rated as equivalent to 1 Boiler Horsepower . Treat this as an industry rule of thumb for sizing and comparison. Neither MCA Title 50, chapter 74 nor ARM 24.122 defines boiler horsepower, and ARM 24.122.301(1) classifies a boiler for licensing purposes by the conditions under which it is actually operated — pressure, temperature, and Btu per hour or horsepower per hour — expressly not by the nameplate.

A Scotch marine fire-tube boiler with 1,500 square feet of heating surface is rated at: 1 , 500 sq ft 10 sq ft/BHP = 150 BHP \frac{1,500 \text{ sq ft}}{10 \text{ sq ft/BHP}} = 150 \text{ BHP} 10 sq ft/BHP 1 , 500 sq ft ​ = 150 BHP Thermal Capacity = 150 BHP × 33 , 475 Btu/hr = 5 , 021 , 250 Btu/hr \text{Thermal Capacity} = 150 \text{ BHP} \times 33,475 \text{ Btu/hr} = 5,021,250 \text{ Btu/hr} Thermal Capacity = 150 BHP × 33 , 475 Btu/hr = 5 , 021 , 250 Btu/hr

Factor of Evaporation (FE) and Equivalent Evaporation

In real operations, feedwater enters a boiler colder than 212°F, and steam is generated at pressures higher than 0 psig. To compare a boiler's actual evaporation to standard BHP, operators calculate the Factor of Evaporation (FE) : FE = h g − h feedwater 970.3 \text{FE} = \frac{h_g - h_{\text{feedwater}}}{970.3} FE = 970.3 h g ​ − h feedwater ​ ​

Where h g h_g h g ​ is total enthalpy of the generated steam, and h feedwater h_{\text{feedwater}} h feedwater ​ is the sensible enthalpy of the incoming feedwater ( T feedwater − 32 T_{\text{feedwater}} - 32 T feedwater ​ − 32 ).

Equivalent Evaporation (lb/hr): Equivalent Evaporation = Actual Evaporation (lb/hr) × FE \text{Equivalent Evaporation} = \text{Actual Evaporation (lb/hr)} \times \text{FE} Equivalent Evaporation = Actual Evaporation (lb/hr) × FE Developed BHP = Equivalent Evaporation 34.5 \text{Developed BHP} = \frac{\text{Equivalent Evaporation}}{34.5} Developed BHP = 34.5 Equivalent Evaporation ​

  • Practical Operator Calculations: Exam Scenarios
  • Scenario 1: Heat Absorption Calculation

A high-pressure steam boiler generates 10,000 lb/hr of dry saturated steam at 150 psig (164.7 psia, h g = 1 , 195.5 Btu/lb h_g = 1,195.5 \text{ Btu/lb} h g ​ = 1 , 195.5 Btu/lb ). The deaerator supplies feedwater at 220°F ( h f ≈ 220 − 32 = 188.1 Btu/lb h_f \approx 220 - 32 = 188.1 \text{ Btu/lb} h f ​ ≈ 220 − 32 = 188.1 Btu/lb ). Calculate the net heat absorbed by the boiler water each hour and the developed BHP.

Heat added per pound of water: Δ h = h g − h feedwater = 1 , 195.5 − 188.1 = 1 , 007.4 Btu/lb \Delta h = h_g - h_{\text{feedwater}} = 1,195.5 - 188.1 = 1,007.4 \text{ Btu/lb} Δ h = h g ​ − h feedwater ​ = 1 , 195.5 − 188.1 = 1 , 007.4 Btu/lb

Total hourly heat transfer: Q total = 10 , 000 lb/hr × 1 , 007.4 Btu/lb = 10 , 074 , 000 Btu/hr Q_{\text{total}} = 10,000 \text{ lb/hr} \times 1,007.4 \text{ Btu/lb} = 10,074,000 \text{ Btu/hr} Q total ​ = 10 , 000 lb/hr × 1 , 007.4 Btu/lb = 10 , 074 , 000 Btu/hr

Developed Boiler Horsepower: Developed BHP = 10 , 074 , 000 Btu/hr 33 , 475 Btu/hr/BHP = 300.9 BHP \text{Developed BHP} = \frac{10,074,000 \text{ Btu/hr}}{33,475 \text{ Btu/hr/BHP}} = \mathbf{300.9 \text{ BHP}} Developed BHP = 33 , 475 Btu/hr/BHP 10 , 074 , 000 Btu/hr ​ = 300.9 BHP

Factor of Evaporation: FE = 1 , 007.4 970.3 = 1.038 \text{FE} = \frac{1,007.4}{970.3} = 1.038 FE = 970.3 1 , 007.4 ​ = 1.038 Equivalent Evaporation = 10 , 000 × 1.038 = 10 , 380 lb/hr \text{Equivalent Evaporation} = 10,000 \times 1.038 = 10,380 \text{ lb/hr} Equivalent Evaporation = 10 , 000 × 1.038 = 10 , 380 lb/hr BHP = 10 , 380 34.5 = 300.9 BHP \text{BHP} = \frac{10,380}{34.5} = \mathbf{300.9 \text{ BHP}} BHP = 34.5 10 , 380 ​ = 300.9 BHP

Loading diagram... Thermodynamic Phase Transitions and Heat Addition for Water at 14.7 psia