Study guide
Fire and Emergency Response
Montana Certified Nursing Assistant CNA
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
The Montana CNA Knowledge Exam: Format, Fees, and Content Outline Eligibility, Training Requirements, and Testing Attempts Scheduling, Test-Day Rules, and Getting Your Results The Montana Nurse Aide Registry, Renewal, and Your Career
2 Safety
Fall Prevention Fire and Emergency Response Body Mechanics Restraints and Restraint Alternatives
3 Infection Control
Hand Hygiene and Standard Precautions Personal Protective Equipment and Transmission-Based Precautions Asepsis, Biohazard Waste, and OSHA Bloodborne Pathogens Rules
4 Personal Care
Bathing and Skin Care Oral Hygiene, Grooming, and Dressing Elimination and Urinary Catheter Care Bed Making and Resident Comfort
5 Communication
Therapeutic Communication Documentation and Reporting Team Communication and Barriers
6 Resident Rights
OBRA Resident Rights, Dignity, and Freedom from Abuse Privacy, HIPAA, and Advance Directives Refusal of Care, Grievances, and the Montana Ombudsman
7 Role and Responsibility
Scope of Practice: What a CNA May and May Not Do Delegation and Supervision Mandatory Reporting and Abuse Professionalism and Montana Certification Rules
8 Basic Nursing Skills
8.1 Vital Signs 8.2 Positioning and Range of Motion 8.3 Transfers and Mobility Devices 8.4 Nutrition, Hydration, and Intake & Output
9 Data Collection and Reporting
Observation and Reporting Measuring and Recording Data
10 Disease Process
10.1 Cardiovascular and Respiratory Conditions 10.2 Diabetes and Metabolic Conditions 10.3 Wounds, Skin Breakdown, and Chronic Conditions
11 Mental Health and Psychosocial Care
Depression, Anxiety, and Grief Understanding and Supporting Behavior End-of-Life Care
12 Care of the Cognitively Impaired
Dementia and Alzheimer's Disease Basics Communication and Validation Techniques Wandering, Sundowning, and Environmental Safety
13 Older Adult Growth and Development
Normal Aging Changes by Body System Psychosocial Needs and Restorative Care
14 The Montana Clinical Skills Test
Skill Test Format and Scoring Hygiene and Grooming Skill Tasks Elimination, Nutrition, and Measurement Skill Tasks Mobility, Positioning, and Vital Signs Skill Tasks
Fire and Emergency Response
Key Takeaways Explain This Topic AI
RACE: Rescue (remove residents from danger), Alarm (activate the alarm), Contain (close doors to confine smoke and fire), Extinguish or Evacuate
PASS for a fire extinguisher: Pull the pin, Aim at the base of the fire, Squeeze the handle, Sweep side to side
Oxygen does not burn but makes everything around it burn faster and hotter — no smoking, open flames, or sparking equipment near oxygen in use
Evacuate horizontally first (through smoke/fire doors on the same floor), moving ambulatory residents first, then wheelchair, then bed-bound residents
For a conscious choking resident who cannot speak or cough, give abdominal thrusts; for cardiac arrest, call for help and begin CPR within your scope
Last updated: August 2026
Fire Response: RACE and PASS
Every healthcare worker must respond to fire the same way, because seconds matter and residents cannot always save themselves. The two acronyms you must know exactly are RACE and PASS .
RACE — What to Do When You Discover a Fire
- Letter Step What it means
- R Rescue Remove residents in immediate danger from the fire area — anyone in the room of the fire comes first
- A Alarm Activate the fire alarm and call the emergency number; give the exact location
- C Contain Confine the fire and smoke by closing doors and windows; never prop fire doors open
- E Extinguish / Evacuate Put out a small fire if you can do so safely, or begin evacuation as directed
The order matters: residents come before the alarm, and the alarm comes before any attempt to fight the fire. Smoke and toxic gases kill more people than flames, which is why containing the fire by closing doors is a rescue measure in itself.
- PASS — Using a Fire Extinguisher
- P — Pull the pin on the extinguisher
- A — Aim at the base of the fire, not the flames
- S — Squeeze the handle to release the agent
- S — Sweep from side to side across the base
Only attempt to extinguish a small fire, keep your exit behind you, and never let the fire get between you and the door.
Oxygen Safety
Oxygen does not burn, but it supports combustion — it makes other materials ignite faster and burn hotter. When oxygen is in use:
- No smoking anywhere in the area; post "Oxygen in Use" signs
- No open flames, candles, lighters, or matches
Avoid sparks — use only facility-approved electrical equipment, avoid wool blankets and synthetic fabrics that create static electricity
- Keep oxygen cylinders secured upright in a holder or cart so they cannot fall and become a projectile
- Keep grease and oil away from oxygen connections
Evacuation and Disaster Preparedness
Facilities use a defend-in-place strategy: because moving residents is dangerous, evacuation happens in stages.
- Horizontal evacuation first — move residents through smoke or fire doors to a safe area on the same floor
- Vertical evacuation (stairs, never elevators) only if the fire cannot be contained
Move order: ambulatory residents first (they can follow instructions quickly), then residents in wheelchairs, then bed-bound residents last using blankets or carries
Before any emergency, know your facility's fire exits, alarm locations, extinguisher locations, and the disaster plan. Facilities hold regular fire drills — take them seriously and know your assigned role. For disasters such as Montana's winter storms, wildfires, or power outages, the facility's emergency plan covers backup power for oxygen and refrigeration, resident identification, and evacuation destinations.
During any evacuation, never use elevators , keep doors closed behind you, stay low if smoke is present, and check doors for heat with the back of your hand before opening them. Bed-bound residents are moved with a blanket drag or carry by enough staff to do it safely — speed matters, but dropping a resident does not save time. Account for every resident at the assembly area using the census list. Facilities also announce emergencies with codes (for example, a fire code); learn your facility's code words and what each one requires of you. Report anything that smells like smoke or looks like faulty electrical equipment — frayed cords and overloaded outlets are common ignition sources, and reporting them is part of the CNA's safety role.
- Choking, Cardiac Arrest, and Poisoning
- Choking (Foreign-Body Airway Obstruction)
If the resident can speak, cough, or breathe , encourage coughing and stay with them — do not slap the back or reach into the mouth
If the resident cannot speak, breathe, or cough (or clutches the throat — the universal choking sign), call for help and give abdominal thrusts (the Heimlich maneuver) : stand behind the resident, make a fist just above the navel, and thrust inward and upward until the object is expelled or the resident becomes unresponsive
For a pregnant or very large resident, use chest thrusts instead
If the resident becomes unresponsive, lower them to the floor, activate the emergency response, and begin CPR, looking in the mouth before giving breaths
Cardiac Arrest
Call for help first (activate the emergency response or call 911 per facility policy), then begin cardiopulmonary resuscitation (CPR) if it is within your scope and the resident does not have a valid do-not-resuscitate (DNR) order. Push hard and fast in the center of the chest; send someone for the automated external defibrillator (AED). Always check the code status — performing CPR on a resident with a DNR violates their rights.
Poisoning and Chemical Hazards
Under OSHA's Hazard Communication Standard, every facility keeps Safety Data Sheets (SDS) for each chemical — cleaning solutions, disinfectants, and medications you handle. The SDS explains the hazards, safe handling, required protective equipment, and first-aid measures. If a chemical contacts skin or eyes, flush with water and report immediately. For a suspected poisoning, call the Poison Control Center at 1-800-222-1222 and follow the nurse's directions — never induce vomiting unless instructed, because some substances cause more damage coming back up. Store all chemicals in their original labeled containers, never in food or drink containers.