Study guide
2.3 Site Assessment, Orientation, Tilt, Azimuth, and Shading Analysis
NABCEP Photovoltaic Associate PVA
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Safety & Job Site Hazard Prevention
1.1 OSHA Regulations, Job Site Safety Standards, and Personal Protective Equipment 1.2 Fall Protection Systems, Ladder Safety, and Roof Access Protocols 1.3 Electrical Safety, Arc Flash Hazards, and Lockout/Tagout (LOTO) Procedures
2 Chapter 2: Solar Resource, Sun-Earth Geometry & Site Assessment
2.1 Solar Radiation Principles, Irradiance vs. Insolation, and Peak Sun Hours 2.2 Sun-Earth Geometry, Solar Angles, Sun Path Charts, and the Solar Window 2.3 Site Assessment, Orientation, Tilt, Azimuth, and Shading Analysis
3 Chapter 3: Electrical Fundamentals & Circuit Principles
3.1 Electrical Quantities, Ohm's Law, and Power Relationships 3.2 Series and Parallel DC Circuits, Voltage, Current, and Resistance Relationships 3.3 National Electrical Code (NEC) Overview, Article 690, and Key Definitions
4 Chapter 4: PV Module Technologies & Performance Characteristics
4.1 Photovoltaic Cell Physics and Module Manufacturing Technologies 4.2 Module Electrical Characteristics, I-V Curves, and Key Nameplate Ratings 4.3 Environmental Impacts: Temperature Coefficients, Irradiance, and Degradation
5 Chapter 5: Inverters, Power Electronics & Rapid Shutdown
5.1 Inverter Classifications, Topologies, and System Configurations 5.2 Inverter Efficiency, MPPT Algorithms, and Grid-Support Features 5.3 Rapid Shutdown Systems, Emergency Disconnects, and NEC 690.12 Requirements
6 Chapter 6: Energy Storage Systems & Battery Integration
6.1 Battery Chemistries, Electrochemical Operation, and Energy Density 6.2 Battery Storage Capacity, Depth of Discharge (DoD), and Cycle Life 6.3 Charge Controller Topologies, Operating Stages, and ESS System Architecture
7 Chapter 7: System Sizing, Electrical Design & NEC Calculations
7.1 Load Profiling, Energy Consumption Analysis, and Sizing Principles 7.2 String Sizing Calculations, Temperature Correction, and Voltage Limits 7.3 Conductor Sizing, Overcurrent Protection Devices (OCPD), and Voltage Drop
8 Chapter 8: Mechanical Integration, Roof Attachments & Structural Loading
8.1 Structural Load Analysis: Dead Loads, Wind Uplift, and Snow Loads 8.2 Roof Attachments, Waterproof Flashing, and Racking Systems 8.3 Ground Mounts, Single-Axis Trackers, Carports, and Mechanical Fasteners
9 Chapter 9: Electrical Installation, Grounding & System Commissioning
9.1 DC and AC Wire Management, Conduit Applications, and Expansion Fittings 9.2 Equipment Grounding, System Grounding, Bonding, and Surge Protection 9.3 System Commissioning, Verification Testing, Labeling, and Handover
10 Chapter 10: Operations, Maintenance, Troubleshooting & Solar Economics
10.1 Preventative Maintenance Programs, Routine Inspections, and Monitoring 10.2 Diagnostic Troubleshooting, Fault Finding, and Performance Testing 10.3 Solar Project Economics, Net Energy Metering, Incentives, and Interconnection
2.3 Site Assessment, Orientation, Tilt, Azimuth, and Shading Analysis
Key Takeaways Explain This Topic AI
A rigorous site assessment surveys structural roof integrity, electrical service panel capacity, physical dimensions, and solar access before finalizing system engineering.
Magnetic declination is the site- and date-dependent angular offset between magnetic north and true north; apply it when converting a compass reading to true array azimuth, then evaluate orientation against the project objective.
Standard rule-of-thumb array tilts specify tilt equal to latitude for maximum annual yield, latitude - 15° for summer production, and latitude + 15° for winter optimization.
Total Solar Resource Fraction (TSRF) is the product of Solar Availability and the Tilt & Azimuth Factor (TAF), quantifying real-world solar potential against an ideal unshaded array.
Inter-row array spacing must be sized to prevent row-to-row self-shading during the winter solstice solar window using the geometric formula: Spacing = Height / tan(Altitude).
Last updated: September 2026
2.3 Site Assessment, Orientation, Tilt, Azimuth, and Shading Analysis
A professional photovoltaic installation begins with a thorough, rigorous site assessment . The goal of the site assessment is to evaluate the solar resource, quantify shading from existing and future vegetation, verify the structural integrity of the mounting structure, determine the electrical integration strategy, and ensure full compliance with the National Electrical Code (NEC) and local building codes.
The Professional Site Assessment Workflow
A complete site assessment combines preliminary remote desktop research with an extensive on-site survey:
1. Preliminary Desktop Audit
Before traveling to the site, the assessor uses satellite imagery, GIS property maps, and digital shading databases to:
Review roof planes, general azimuth, and preliminary module layout capacity.
Examine utility billing history (12 consecutive months of electric utility bills) to determine annual energy consumption (total kWh) and peak power demand (kW).
Identify utility interconnection policies, Net Energy Metering (NEM) guidelines, and local Authority Having Jurisdiction (AHJ) permitting requirements.
2. On-Site Physical and Structural Audit
Roof covering condition: Identify the roofing system, age, warranty, drainage, damage, repair history, and estimated remaining service life with the owner and qualified roofing professional. Compare expected roof work with the PV service plan and economics; reroofing before PV may be prudent, but no universal 15- or 20-year threshold applies to every project.
Roof framing and structural members: Where safe and authorized, inspect or document rafters, trusses, purlins, decking, spacing, spans, connections, alterations, decay, leakage, fire damage, and sagging. Verify dimensions and material from field evidence and approved documents; do not assume standard spacing or a universal minimum sheathing thickness.
Roof obstructions and fire access: Measure vents, HVAC equipment, chimneys, skylights, drains, and access routes. Determine pathways, ridge setbacks, smoke-ventilation areas, edge clearances, and exceptions from the locally adopted fire and building codes and approved plan; a 36-inch dimension is common in some provisions but not universal.
3. Electrical Service and Balance-of-System Audit
Main service panel: Record bus and main ratings, conductor and breaker details, available spaces, and the interconnection point. Evaluate the applicable supply-side or load-side method in the adopted NEC; a 120% bus calculation is one conditional option, not the only compliance path.
Physical Panel Space: Verify available breaker spaces for the PV backfeed overcurrent protection device (OCPD).
Grounding Electrode System (GES): Locate the grounding electrode conductor (GEC), ground rods, copper water pipe bond, and supplemental grounding electrodes required by NEC Article 250.
Service Equipment Location: Determine mounting locations for inverters, DC/AC disconnects, rapid shutdown initiators, and the conduit run path from the roof to the service equipment.
Assessment Domain Critical Items Inspected NABCEP Technical Requirement
Structural Rafter size, spacing, span, decking thickness, roof age Verify building code structural load capacity (dead load + wind uplift + snow load); minimum 15-year roof life.
Electrical Main service panel bus rating, main breaker rating, meter enclosure Verify NEC 705.12 backfeed limit (120% rule) or plan line-side tap (NEC 705.11); verify existing grounding system.
Mechanical Shingle condition, flashing points, attachment spacing Identify structural attachment points (truss centers) and ensure waterproofing with code-compliant flashed mounts.
Fire / Safety Roof ridge, eave, and valley clear access pathways Ensure minimum 36" firefighter access pathways per IFC / NFPA 1 guidelines.
Solar / Shade Roof pitch, azimuth, horizon trees, parapet walls Quantify solar access with shade tools; calculate Total Solar Resource Fraction (TSRF).
Magnetic Declination and Compass Correction
For an unshaded fixed array with a symmetric annual-energy objective in the Northern Hemisphere, true south is a useful reference, not a universal required azimuth. Roof geometry, terrain, weather, morning or evening loads, export tariffs, storage controls, and interconnection limits can make an east, west, or split orientation preferable. Convert magnetic observations to true azimuth using current site declination.
Understanding Magnetic Declination
Magnetic Declination (also called magnetic variation) is the angular difference between True Geographic North and Magnetic North at a specific location on Earth's surface.
East (Positive) Declination: Magnetic North lies to the East of True North (typical in the Western United States, ranging from + 10 ∘ +10^\circ + 1 0 ∘ to + 16 ∘ +16^\circ + 1 6 ∘ in California, Oregon, and Washington).
West (Negative) Declination: Magnetic North lies to the West of True North (typical in the Eastern United States, ranging from − 10 ∘ -10^\circ − 1 0 ∘ to − 16 ∘ -16^\circ − 1 6 ∘ in New England).
Agonic Line: The irregular line connecting locations where magnetic declination is exactly 0 ∘ 0^\circ 0 ∘ (running roughly from Lake Superior down through the Mississippi valley to Florida).
Compass Calibration Rules:
Before recording any azimuth measurement on a roof, the site assessor must adjust the compass for local declination:
If local declination is East (e.g., + 12 ∘ E +12^\circ\text{E} + 1 2 ∘ E ) , rotate the internal compass azimuth bezel or turn the declination adjustment screw 12 ∘ 12^\circ 1 2 ∘ clockwise (to the East).
If local declination is West (e.g., − 14 ∘ W -14^\circ\text{W} − 1 4 ∘ W ) , rotate the internal bezel 14 ∘ 14^\circ 1 4 ∘ counterclockwise (to the West). True Azimuth = Magnetic Heading ± Magnetic Declination \text{True Azimuth} = \text{Magnetic Heading} \pm \text{Magnetic Declination} True Azimuth = Magnetic Heading ± Magnetic Declination
NABCEP Exam Tip: Failing to adjust for magnetic declination in regions with high declination (such as the Pacific Northwest or Maine, where declination approaches 15 ∘ 15^\circ 1 5 ∘ ) will cause an installer to orient an array 15 ∘ 15^\circ 1 5 ∘ off True South, causing an unexpected 3% to 6% reduction in modeled annual energy harvest.
- Array Tilt and Azimuth Optimization Strategies
- Array Azimuth Orientation
Maximum Annual Generation: In the Northern Hemisphere, an azimuth of True South ( 180 ∘ 180^\circ 18 0 ∘ ) collects the greatest total solar energy over an entire calendar year. Orientations between 160 ∘ 160^\circ 16 0 ∘ and 200 ∘ 200^\circ 20 0 ∘ generally achieve over 96 % 96\% 96% to 98 % 98\% 98% of peak annual potential.
Time-of-Use (TOU) Rate Optimization: In utility territories with aggressive Time-of-Use rate structures (such as California under NEM 3.0), electricity is most expensive during the late afternoon and early evening peak window (e.g., 4:00 PM to 9:00 PM). In these markets, orienting arrays toward the Southwest ( 210 ∘ – 225 ∘ 210^\circ–225^\circ 21 0 ∘ –22 5 ∘ ) or West ( 240 ∘ – 270 ∘ 240^\circ–270^\circ 24 0 ∘ –27 0 ∘ ) intentionally sacrifices 10% to 15% of total annual kWh production in exchange for generating valuable power when peak utility credits are highest.
Array Tilt Angle Strategies
The tilt angle ( β \beta β ) is the angle of the PV module surface relative to the horizontal plane:
Annual Yield Optimization (Rule of Thumb): β o p t i m a l ≈ Latitude \beta_{optimal} \approx \text{Latitude} β o pt ima l ≈ Latitude
Tilted approximately equal to local latitude (e.g., a 35 ∘ 35^\circ 3 5 ∘ tilt at 35 ∘ N 35^\circ\text{N} 3 5 ∘ N latitude).
Summer Generation Optimization: β s u m m e r ≈ Latitude − 15 ∘ \beta_{summer} \approx \text{Latitude} - 15^\circ β s u mm er ≈ Latitude − 1 5 ∘
A flatter tilt exposes modules more directly to the high summer sun. Used for grid-tied systems designed to offset heavy summer air-conditioning loads under high summer utility rates.
Winter Generation Optimization: β w i n t e r ≈ Latitude + 15 ∘ \beta_{winter} \approx \text{Latitude} + 15^\circ β w in t er ≈ Latitude + 1 5 ∘
A steeper tilt aligns modules perpendicular to the low winter sun. Critical for off-grid battery-based systems where winter insolation is the primary design bottleneck; the steep angle also encourages accumulated snow to slide off.
Minimum Tilt Requirement: Low tilt can increase soiling and standing-water risk, but there is no universal 10-degree minimum. Use the module and mounting-system installation limits, roof drainage design, wind and structural analysis, row spacing, and the project performance model. Some listed systems use very low tilt successfully when drainage and maintenance are addressed.
Pitch (Rise : Run) Angle in Degrees ( ∘ ^\circ ∘ ) Common Structural Application
2 : 12 9.5 ∘ 9.5^\circ 9. 5 ∘ Low-slope commercial roofs; minimum recommended PV self-cleaning angle.
3 : 12 14.0 ∘ 14.0^\circ 14. 0 ∘ Low-pitch residential roofs.
4 : 12 18.4 ∘ 18.4^\circ 18. 4 ∘ Very common residential asphalt shingle roof pitch.
6 : 12 26.6 ∘ 26.6^\circ 26. 6 ∘ Moderate residential pitch; excellent compromise for latitudes 28 ∘ – 35 ∘ N 28^\circ–35^\circ\text{N} 2 8 ∘ –3 5 ∘ N .
8 : 12 33.7 ∘ 33.7^\circ 33. 7 ∘ Standard residential pitch; matches optimal latitude tilt for mid-latitude US.
12 : 12 45.0 ∘ 45.0^\circ 45. 0 ∘ Steep residential roof; requires specialized fall protection and staging.
Fixed-Tilt vs. Tracking Mounts
Fixed-Tilt Arrays: Mechanically simple, zero moving parts, lowest capital and operating cost. Dominates residential and commercial rooftops.
Single-Axis Horizontal Trackers: Rotate East-to-West along a North-South horizontal torque tube. Boosts annual energy production by 15 % 15\% 15% to 25 % 25\% 25% over fixed-tilt arrays, flattening the daily production curve into an extended square wave. Standard in utility-scale solar projects.
Dual-Axis Trackers: Continuously adjust both azimuth and altitude to maintain a 90 ∘ 90^\circ 9 0 ∘ normal angle to the sun. Boosts production by 30 % 30\% 30% to 40 % 40\% 40% , but high mechanical complexity, motor maintenance, and wind loading limit their use to niche off-grid or research applications.
Shading Analysis Tools and Technologies
Shading is the single greatest cause of underperformance and warranty claims in photovoltaic systems. Professional site assessment employs dedicated optical and digital tools to quantify shade.
1. The Solar Pathfinder
Operating Principle: A non-electronic, mechanical instrument consisting of a calibrated reflective convex transparent dome mounted on a levelable base with an internal compass.
How It Works: A site-specific sun path diagram (calibrated for the site's latitude) is inserted beneath the dome. When placed at the proposed array location, the convex dome reflects an image of the entire 360 ∘ 360^\circ 36 0 ∘ horizon skyline—including trees, chimneys, and neighboring rooflines. The surveyor looks straight down through the dome and traces the reflected skyline onto the sun path diagram.
Advantages: Completely passive (no batteries required); fast; works on cloudy, overcast days because it relies on physical reflection rather than digital camera exposure.
2. Electronic Shade Assessment Tools (Solmetric SunEye)
Operating Principle: An electronic handheld instrument containing a calibrated digital fisheye camera, an electronic compass, and tilt/level sensors.
How It Works: The device captures a panoramic hemispherical photograph of the sky dome at the proposed module location. On-board software automatically identifies obstructions, traces the open sky, superimposes monthly sun paths, and calculates hourly and monthly solar access percentages.
Advantages: Stores digital records for engineering reports, eliminates manual tracing errors, and exports digital shading files directly into design software.
3. Drone Photogrammetry and LiDAR 3D Modeling
Operating Principle: Autonomous aerial drones capture high-resolution overlapping aerial photographs and LiDAR point clouds of the property.
How It Works: Specialized software (e.g., Aurora Solar, HelioScope) reconstructs an exact 3D digital surface model (DSM) of the building, roof planes, and surrounding trees, simulating sub-module shading losses for every hour of the year.
Assessment Tool Sensor Technology Weather Dependency Primary Benefit
Solar Pathfinder Reflective convex dome + paper sun chart Can be used in any weather (sunny or cloudy) 100% passive, zero batteries, fast on-roof audit
Solmetric SunEye Digital fisheye lens + electronic compass/tilt Sunny or evenly overcast; difficult in rain Automated digital reports, direct CAD export
Drone LiDAR / 3D CAD Aerial photogrammetry point cloud Requires flyable weather (low wind, no precipitation) Remote assessment; no roof climbing required
Quantifying Solar Access: Solar Availability, TAF, and TSRF
To standardize solar resource reporting across the industry, three interrelated metrics are defined:
1. Solar Availability (Solar Access %)
The percentage of total solar radiation available at a given location after accounting for shading from surrounding trees, structures, and horizon obstacles. Solar Availability = Actual Unshaded Insolation at Site Potential Insolation with Zero Obstructions \text{Solar Availability} = \frac{\text{Actual Unshaded Insolation at Site}}{\text{Potential Insolation with Zero Obstructions}} Solar Availability = Potential Insolation with Zero Obstructions Actual Unshaded Insolation at Site
2. Tilt and Azimuth Factor (TAF)
The ratio of solar radiation received by an array at its actual tilt and azimuth compared to the solar radiation it would receive if oriented at the optimal tilt and azimuth (typically True South at latitude tilt) for that location. TAF = Insolation at Actual Tilt and Azimuth Insolation at Optimal Tilt and True South Azimuth \text{TAF} = \frac{\text{Insolation at Actual Tilt and Azimuth}}{\text{Insolation at Optimal Tilt and True South Azimuth}} TAF = Insolation at Optimal Tilt and True South Azimuth Insolation at Actual Tilt and Azimuth
3. Total Solar Resource Fraction (TSRF)
The Master Metric: TSRF combines both the effect of orientation and the effect of shading into a single unified percentage: TSRF = Solar Availability × Tilt and Azimuth Factor (TAF) \text{TSRF} = \text{Solar Availability} \times \text{Tilt and Azimuth Factor (TAF)} TSRF = Solar Availability × Tilt and Azimuth Factor (TAF)
Realistic Calculation Scenario: An assessor surveys a residential roof plane in Raleigh, North Carolina. The roof faces Southwest ( 225 ∘ 225^\circ 22 5 ∘ azimuth) with an 18° tilt, resulting in a TAF of 0.92 0.92 0.92 (92%) . A Solar Pathfinder analysis indicates that surrounding pine trees reduce Solar Availability to 0.85 0.85 0.85 (85%) .
TSRF = 0.85 × 0.92 = 0.782 = 78.2 % \text{TSRF} = 0.85 \times 0.92 = 0.782 = 78.2\% TSRF = 0.85 × 0.92 = 0.782 = 78.2%
Many state incentive programs (such as NY-Sun or MassCEC) mandate a minimum TSRF (typically ≥ 70 % \ge 70\% ≥ 70% to 75 % 75\% 75% ) for a solar installation to qualify for public rebates.
Inter-Row Spacing to Prevent Self-Shading
On flat commercial roofs and ground-mounted arrays, PV modules are mounted on tilted racks arranged in successive parallel rows. If adjacent rows are spaced too closely together, the front row will cast a shadow across the lower portion of the row behind it.
Design Baseline: The Winter Solstice Benchmark
To ensure zero row-to-row shading during the valuable solar window, inter-row spacing must be designed for the day of the year when the sun is at its lowest altitude angle: the Winter Solstice (December 21) .
Minimum Row Spacing Formula: d = h tan ( α ) d = \frac{h}{\tan(\alpha)} d = tan ( α ) h
where:
d d d = Minimum horizontal clear spacing distance between the back of the front row and the front of the rear row (or row pitch).
h h h = Vertical height difference between the top edge of the front module row and the bottom edge of the rear module row.
- α \alpha α = Solar altitude angle at the critical design time on December 21. Sun's Rays at Altitude Angle (α)
- \
- \
- \
- [Front Row] \
- /| \
- / | \
- / | Height (h) \
- /___| \__________ [Rear Row]
- |<---- Spacing (d) ------>|
- d = h / tan(α)
Sizing Calculation Example:
A commercial installer is laying out tilted ballasted racks on a flat roof in Richmond, Virginia ( 37.5 ∘ N 37.5^\circ\text{N} 37. 5 ∘ N latitude):
Rack Dimensions: Each module row is tilted at 20 ∘ 20^\circ 2 0 ∘ , creating a vertical height rise h = 0.90 meters h = 0.90 \text{ meters} h = 0.90 meters (35.4 inches).
Critical Solar Altitude at Solar Noon on Dec 21: α n o o n = 90 ∘ − 37.5 ∘ − 23.45 ∘ = 29.05 ∘ \alpha_{noon} = 90^\circ - 37.5^\circ - 23.45^\circ = 29.05^\circ α n oo n = 9 0 ∘ − 37. 5 ∘ − 23.4 5 ∘ = 29.0 5 ∘
Calculate Tangent: tan ( 29.05 ∘ ) ≈ 0.555 \tan(29.05^\circ) \approx 0.555 tan ( 29.0 5 ∘ ) ≈ 0.555
Calculate Minimum Spacing Distance ( d d d ): d = 0.90 m 0.555 ≈ 1.62 meters (63.8 inches) d = \frac{0.90 \text{ m}}{0.555} \approx 1.62 \text{ meters} \text{ (63.8 inches)} d = 0.555 0.90 m ≈ 1.62 meters (63.8 inches)
If the system designer wishes to prevent shading throughout the entire 9:00 AM to 3:00 PM solar window (rather than just at solar noon), the solar altitude at 9:00 AM ( ≈ 15 ∘ – 18 ∘ \,\approx 15^\circ–18^\circ ≈ 1 5 ∘ –1 8 ∘ ) and the azimuth angle of the shadow must be used, requiring even wider row spacing.
Impact of Partial Shading on Electrical Performance
Partial shading on a photovoltaic array does not behave like a shadow falling on a solar thermal collector. In a solar thermal collector, shading 10% of the collector reduces heat gain by approximately 10%. In a photovoltaic module, shading just one or two solar cells can collapse the power output of an entire string by 30% to 100% .
Physics of Shaded Cells and Reverse Bias
A typical crystalline silicon module consists of 60, 72, or 120/144 half-cut cells connected in series . In a series circuit, current must remain identical throughout the entire loop ( I t o t a l = I 1 = I 2 = I 3 I_{total} = I_1 = I_2 = I_3 I t o t a l = I 1 = I 2 = I 3 ).
When a single solar cell is shaded:
Its ability to generate photocurrent drops proportional to the reduction in light.
The remaining unshaded cells in the series string continue generating high photocurrent.
The unshaded cells force their high current through the shaded cell.
The shaded cell can no longer operate in forward bias; it is driven into reverse bias , acting as an electrical resistor.
The shaded cell dissipates electrical energy generated by the rest of the string as intense localized heat .
Without protection, this localized heating causes hot spots , which can crack the silicon wafer, degrade solder joints, blister the backsheet, and permanently destroy the module.
Bypass Diode Operation
To prevent catastrophic hot-spot destruction, module manufacturers integrate bypass diodes inside the module junction box:
In a standard 60-cell module, cells are divided into three series groups of 20 cells each, with one bypass diode wired in parallel across each group.
Normal Unshaded Operation: The cell groups generate voltage, reverse-biasing the bypass diodes so that no current flows through them.
Shaded Operation: When a cell is shaded and driven into reverse bias, the voltage across that 20-cell group reverses. This forward-biases the bypass diode, allowing string current to flow around the shaded cell group.
The Consequence on String Voltage and MPPT
While bypass diodes prevent module destruction, their activation causes significant electrical consequences:
When a bypass diode conducts, that entire 20-cell sub-string is bypassed, causing the module to lose one-third of its operating voltage (approx. 10V to 13V DC) .
If multiple modules in a series string experience shading, string DC voltage drops dramatically.
If string voltage falls below the inverter's minimum MPPT operating voltage ( V m p p t , m i n V_{mppt,min} V m ppt , min ) , the inverter can no longer track the string's maximum power point, causing the entire string to disconnect or collapse its electrical harvest.
Mitigation Strategies
Module-Level Power Electronics (MLPE): Utilizing DC power optimizers or microinverters isolates Maximum Power Point Tracking to each individual module. If one module is shaded, only that module's power is reduced; adjacent unshaded modules continue operating at their full independent maximum power point.
Landscape vs. Portrait Orientation: On arrays subject to ground-level or row-to-row shading, orienting modules in landscape aligns the bypass diode sub-strings parallel to the shadow line, allowing two-thirds of the module to continue operating even when the bottom edge is shaded.