Study guide
9.2 Light-Gauge Metal Framing
NASCLA Contractor Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Coverage Map & Exam Overview
Coverage Map & Exam Overview
2 Business Organization, Licensing & Law
1.1 Business Entity Types and Formation 1.2 NASCLA Trade-Exam Waiver and Agency Licensing Boundaries 1.3 Construction Contract Law and Types of Contracts 1.4 Lien Law, Bond Claims, and Dispute Resolution
3 Financial Management, Tax & Labor Law
2.1 Financial Statements, Job Costing, and Cash Flow 2.2 Payroll, Federal/State Tax, and Recordkeeping 2.3 Labor & Employment Law (FLSA, immigration/I-9, EEO) 2.4 Insurance, Surety Bonds, and Risk Management
4 Estimating, Bidding & Plan Reading
3.1 Reading Construction Drawings and Specifications (CSI MasterFormat) 3.2 Quantity Takeoff and Material Estimating 3.3 Bidding, Markup, Overhead, and Profit 3.4 Change Orders, Allowances, and Unit Pricing
5 Project Management & Scheduling
4.1 Project Delivery Methods and the Submittal/RFI Process 4.2 Scheduling (CPM, Bar Charts, Critical Path) 4.3 Quality Control, Inspections, and Closeout 4.4 Permits, Codes, and the Inspection Process
6 Construction Safety & OSHA (29 CFR 1926)
5.1 OSHA Administration, Recordkeeping, and the General Duty Clause 5.2 Fall Protection, Scaffolds, and Ladders 5.3 Excavation/Trenching, Electrical, and Hazard Communication 5.4 PPE, Fire Protection, Cranes, and Confined Spaces
7 General Requirements & Sitework
6.1 Division 01 General Requirements and Temporary Facilities 6.2 Surveying, Site Layout, and Excavation 6.3 Soils, Compaction, and Erosion/Sediment Control 6.4 Foundations, Footings, and Site Drainage
8 Concrete (CSI Division 03)
7.1 Concrete Materials, Mix Design, and Water-Cement Ratio 7.2 Formwork and Reinforcement Placement 7.3 Placing, Finishing, Curing, and Testing (slump, cylinders) 7.4 Concrete Defects, Joints, and Cold-Weather Practices
9 Masonry (CSI Division 04)
8.1 Masonry Units, Mortar Types (M/S/N/O), and Grout 8.2 Brick and CMU Bonds, Reinforcement, and Coursing 8.3 Lintels, Control/Expansion Joints, and Flashing 8.4 Masonry Estimating and Cold/Hot Weather Construction
10 Metals & Wood (CSI Divisions 05 & 06)
9.1 Structural Steel, Connections, and Welding/Bolting 9.2 Light-Gauge Metal Framing 9.3 Wood Framing, Species/Grades, and Fasteners 9.4 Engineered Wood, Trusses, and Load Paths
11 Thermal & Moisture Protection (CSI Division 07)
10.1 Waterproofing, Dampproofing, and Below-Grade Protection 10.2 Insulation, R-Values, and Vapor Barriers 10.3 Roofing Systems (steep-slope and low-slope) and Underlayment 10.4 Flashing, Sealants, and Air Barriers
12 Openings & Finishes (CSI Divisions 08 & 09)
11.1 Doors, Windows, Glazing, and Hardware 11.2 Gypsum Board, Plaster, and Framing 11.3 Flooring, Tile, and Acoustical Ceilings 11.4 Painting, Coatings, and Finish Schedules
13 Mechanical, Plumbing & Electrical Overview
12.1 Plumbing Systems, Fixtures, and DWV/Supply Basics 12.2 HVAC Systems and Load Concepts 12.3 Electrical Systems, Service, and NEC Basics 12.4 Coordination, Rough-In, and Energy Code
9.2 Light-Gauge Metal Framing
Key Takeaways Explain This Topic AI
Cold-formed steel framing follows IBC Chapter 22 and AISI S100/S240 (structural) or S220 (nonstructural).
The universal designator gives web depth (1/100 in), member type letter, flange (1/100 in), and thickness in mils.
Thickness is specified in mils, not gauge: 33 mil ≈ 20 ga, 43 mil ≈ 18 ga, 54 mil ≈ 16 ga.
Members are joined with self-drilling self-tapping screws, never field-nailed; exterior uses G90 galvanizing.
Studs lay out at 16 or 24 in o.c.; stud count = (length/spacing) + 1 plus openings and corners.
Last updated: June 2026
9.2 Light-Gauge Metal Framing
Cold-formed steel (CFS) , also called light-gauge metal framing , falls under CSI Division 05 40 00 . Design references are IBC Chapter 22 and the American Iron and Steel Institute (AISI) S100 North American Specification, plus AISI S240 for the standard. CFS is roll-formed from sheet steel rather than hot-rolled, so it behaves and is detailed very differently from structural steel.
The Universal Designator System
CFS members use a four-part code, e.g. 362S162-54 :
- Segment Meaning Example
- First 3 digits Web depth in 1/100 inch 362 = 3.625 in
- Letter Member type S = stud, T = track, U = channel, F = furring
- Next 3 digits Flange width in 1/100 in 162 = 1.625 in
- Last 2 digits Base steel thickness in mils 54 = 54 mils
So 362S162-54 is a 3-5/8-inch stud, 1-5/8-inch flange, 54-mil (≈16 gauge) thickness. Trap: depth and flange are in hundredths of an inch , not gauge.
Gauge-to-Mil Conversion
Modern CFS is specified by mil (thousandths of an inch) of base metal thickness, but the field still talks gauge. Memorize the common equivalents:
- Mils Approx. gauge Base thickness
- 18 25 ga 0.0179 in
- 27 22 ga 0.0269 in
- 33 20 ga 0.0329 in
- 43 18 ga 0.0428 in
- 54 16 ga 0.0538 in
- 68 14 ga 0.0677 in
The color coding (AISI): a painted ID strip identifies thickness on the member.
Structural vs. Nonstructural
Nonstructural (interior partition) studs are typically EQ (equivalent) gauge or thin 25/20-gauge, carrying only drywall and lateral wind/partition loads. Governed by AISI S220 .
Structural / load-bearing studs are 33-mil and heavier, carry axial and bending loads, and follow AISI S240/S100 . Galvanized coating is commonly G60 (interior) or G90 (exterior/high-humidity), where G90 = 0.90 oz zinc per square foot total both sides.
Spacing, Takeoff, and Bridging
Studs are spaced 16 inches or 24 inches on center (o.c.) . Stud count for a wall = (wall length in inches / spacing) + 1, then add studs for openings, corners, and intersections.
Worked takeoff: a 40-foot partition at 16 in o.c. = (480 / 16) + 1 = 31 studs , before adding ~2 per corner and king/jack studs at each door. Track is ordered as top + bottom = 2 x 40 = 80 linear feet .
Bridging/bracing rows control stud rotation and weak-axis buckling and are required at intervals set by the design — commonly one row at mid-height for partition walls and multiple rows for tall load-bearing walls. Cold-rolled channel (CRC) through the stud knockouts plus clip angles, or proprietary flat-strap bracing, satisfies this. Deflection track (slotted or double-track) at the head of non-load-bearing partitions allows the structure above to deflect without loading the studs — omitting it cracks drywall, a frequent callback.
Connections and Common Traps
CFS is joined with self-drilling, self-tapping screws (e.g. #8, #10, #12) — not welded in the field on light members, and never nailed. Bridging/bracing rows control stud rotation and are required at intervals per the design (commonly mid-height for shorter walls).
Practice checks:
Mils, not gauge, is the code unit; convert correctly (33 mil ≈ 20 ga).
Track (T) has no return lip; stud (S) has a stiffening lip — do not interchange in a takeoff.
Fire-rated assemblies require listed screws/spacing; substituting fasteners voids the UL listing.
A stud must seat fully into the track with a code-limited gap (typically 1/8 in max) at the bearing end, and screws are placed each side of the flange.
EQ-gauge studs are thinner steel marketed as equivalent to a heavier gauge for nonstructural use only — never substitute EQ for a load-bearing 33-mil-plus member.