Study guide
9.3 Wood Framing, Species/Grades, and Fasteners
NASCLA Contractor Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Coverage Map & Exam Overview
Coverage Map & Exam Overview
2 Business Organization, Licensing & Law
1.1 Business Entity Types and Formation 1.2 NASCLA Trade-Exam Waiver and Agency Licensing Boundaries 1.3 Construction Contract Law and Types of Contracts 1.4 Lien Law, Bond Claims, and Dispute Resolution
3 Financial Management, Tax & Labor Law
2.1 Financial Statements, Job Costing, and Cash Flow 2.2 Payroll, Federal/State Tax, and Recordkeeping 2.3 Labor & Employment Law (FLSA, immigration/I-9, EEO) 2.4 Insurance, Surety Bonds, and Risk Management
4 Estimating, Bidding & Plan Reading
3.1 Reading Construction Drawings and Specifications (CSI MasterFormat) 3.2 Quantity Takeoff and Material Estimating 3.3 Bidding, Markup, Overhead, and Profit 3.4 Change Orders, Allowances, and Unit Pricing
5 Project Management & Scheduling
4.1 Project Delivery Methods and the Submittal/RFI Process 4.2 Scheduling (CPM, Bar Charts, Critical Path) 4.3 Quality Control, Inspections, and Closeout 4.4 Permits, Codes, and the Inspection Process
6 Construction Safety & OSHA (29 CFR 1926)
5.1 OSHA Administration, Recordkeeping, and the General Duty Clause 5.2 Fall Protection, Scaffolds, and Ladders 5.3 Excavation/Trenching, Electrical, and Hazard Communication 5.4 PPE, Fire Protection, Cranes, and Confined Spaces
7 General Requirements & Sitework
6.1 Division 01 General Requirements and Temporary Facilities 6.2 Surveying, Site Layout, and Excavation 6.3 Soils, Compaction, and Erosion/Sediment Control 6.4 Foundations, Footings, and Site Drainage
8 Concrete (CSI Division 03)
7.1 Concrete Materials, Mix Design, and Water-Cement Ratio 7.2 Formwork and Reinforcement Placement 7.3 Placing, Finishing, Curing, and Testing (slump, cylinders) 7.4 Concrete Defects, Joints, and Cold-Weather Practices
9 Masonry (CSI Division 04)
8.1 Masonry Units, Mortar Types (M/S/N/O), and Grout 8.2 Brick and CMU Bonds, Reinforcement, and Coursing 8.3 Lintels, Control/Expansion Joints, and Flashing 8.4 Masonry Estimating and Cold/Hot Weather Construction
10 Metals & Wood (CSI Divisions 05 & 06)
9.1 Structural Steel, Connections, and Welding/Bolting 9.2 Light-Gauge Metal Framing 9.3 Wood Framing, Species/Grades, and Fasteners 9.4 Engineered Wood, Trusses, and Load Paths
11 Thermal & Moisture Protection (CSI Division 07)
10.1 Waterproofing, Dampproofing, and Below-Grade Protection 10.2 Insulation, R-Values, and Vapor Barriers 10.3 Roofing Systems (steep-slope and low-slope) and Underlayment 10.4 Flashing, Sealants, and Air Barriers
12 Openings & Finishes (CSI Divisions 08 & 09)
11.1 Doors, Windows, Glazing, and Hardware 11.2 Gypsum Board, Plaster, and Framing 11.3 Flooring, Tile, and Acoustical Ceilings 11.4 Painting, Coatings, and Finish Schedules
13 Mechanical, Plumbing & Electrical Overview
12.1 Plumbing Systems, Fixtures, and DWV/Supply Basics 12.2 HVAC Systems and Load Concepts 12.3 Electrical Systems, Service, and NEC Basics 12.4 Coordination, Rough-In, and Energy Code
9.3 Wood Framing, Species/Grades, and Fasteners
Key Takeaways Explain This Topic AI
Wood framing (CSI 06 10 00) follows IBC Chapter 23, the AWC NDS, and IRC/IBC span tables.
Lumber is sold nominal but installed dressed: a 2x10 is actually 1-1/2 x 9-1/4 in; use actual size in calcs.
No. 2 is the default framing grade; DF-L spans farther than SPF at equal size due to higher Fb.
Floor joist allowable span shortens as spacing widens (16 to 24 in o.c.) at deflection limit L/360.
Treated lumber (AWPA U1) needs hot-dip galvanized (A153) or stainless fasteners; follow IBC Table 2304.10.1 nailing.
Last updated: June 2026
9.3 Wood Framing, Species/Grades, and Fasteners
Wood framing is CSI Division 06 10 00 (Rough Carpentry). Your references are IBC Chapter 23 , the AWC National Design Specification (NDS) for Wood Construction , and the AWC Wood Frame Construction Manual (WFCM) . Allowable spans come from IBC span tables and the International Residential Code (IRC) for light-frame work. Know nominal vs. actual lumber sizes cold.
Nominal vs. Actual Dimensions
Lumber is sold by nominal size but installed at actual (dressed, S4S) size:
- Nominal Actual
- 1x 3/4 in
- 2x4 1-1/2 x 3-1/2 in
- 2x6 1-1/2 x 5-1/2 in
- 2x8 1-1/2 x 7-1/4 in
- 2x10 1-1/2 x 9-1/4 in
- 2x12 1-1/2 x 11-1/4 in
Trap: a 2x10 joist is 9-1/4 in deep, not 10 in. Section properties for span checks use the actual depth.
Species, Grades, and Design Values
Common framing species/groups: Douglas Fir-Larch (DF-L) , Southern Pine (SP) , Spruce-Pine-Fir (SPF) , Hem-Fir . Visual grades from best to worst: Select Structural, No. 1, No. 2, No. 3, Stud, Construction, Standard, Utility. No. 2 is the typical framing default.
Design values from the NDS include Fb (bending), Fv (shear), Fc-perp (compression perpendicular to grain), and E (modulus of elasticity). DF-L No. 2 2x10 has higher Fb than SPF No. 2, so it spans farther.
Span Example and Spacing
Floor joists carry live + dead load and are sized from IRC/IBC tables by species, grade, size, spacing, and deflection limit L/360 for floors (L/240 for roofs with plaster, L/180 typical roof).
Worked example: DF-L No. 2 2x10 joists at 16 in o.c., 40 psf live / 10 psf dead span roughly 16 ft 1 in per the IRC table. Increase spacing to 24 in o.c. and the same joist drops to about 13 ft 1 in . Wider spacing = shorter allowable span. Always confirm against the printed table — do not interpolate from memory.
Header sizing over openings follows IRC Table R602.7: a built-up (2) 2x10 DF-L header spans roughly 7-8 ft carrying one floor plus roof, depending on snow load and building width. Notching and boring limits protect framing: a joist notch may not exceed 1/6 the depth and must avoid the middle third of the span; bored holes are limited to 1/3 the depth , kept 2 in from edges (IRC R502.8). Over-notching a joist for plumbing is a classic field and inspection failure.
Pressure-Treated Lumber and Moisture
Wood in contact with concrete/masonry or exposed to weather must be preservative-treated per AWPA U1 with retention by use category (e.g. UC4A ground contact ~0.40 pcf for ACQ). Treated lumber is corrosive to steel, so fasteners must be hot-dip galvanized (ASTM A153) or stainless — plain or electro-galvanized fasteners fail prematurely. A sill plate on a foundation must be treated and anchored.
Fasteners and the IBC Fastening Schedule
Nails are specified by penny (d) size: a 16d common nail is 3-1/2 in long, a 10d is 3 in, an 8d is 2-1/2 in. The IBC Table 2304.10.1 (Fastening Schedule) dictates nailing — e.g., a stud to top/bottom plate is end-nailed with 2-16d or toe-nailed with 4-8d . Anchor bolts for sill plates are typically 1/2-inch min, 6 ft o.c. max, within 12 in of plate ends (IBC/IRC), with a minimum of two bolts per piece , and embedded at least 7 inches into concrete or grouted masonry.
Moisture content at installation should be 19% or less ('S-DRY' or 'KD' stamp) for dimension lumber; higher MC ('S-GRN') leads to shrinkage, nail-pop, and crowning. Read the grade stamp for mill number, species/group, grade, MC, and grading-agency mark (e.g. WWPA, SPIB). A worked board-foot takeoff: board feet = (thickness-in x width-in x length-ft) / 12 . A 2x10 x 16 ft = (2 x 10 x 16) / 12 = 26.7 bd ft ; multiply by the joist count for the order.