Study guide

11.1 Imaging Technology

NBCE Part II Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts 1.2 Format, Sessions, and Test Day 1.3 Scoring, Fees, and Retakes 1.4 Study Strategy by Domain Weight

2 General Diagnosis: History and Physical Examination

2.1 Case History 2.2 Vital Signs 2.3 Head and Neck Examination/Findings 2.4 Thorax Examination/Findings

3 General Diagnosis: Abdomen, Urogenital Exam, and Labs

3.1 Abdominal Examination/Findings 3.2 Rectal and Male Urogenital Examination/Findings 3.3 Laboratory Interpretation

4 General Diagnosis: Clinical Impression — EENT through Blood

4.1 Eyes, Ears, Nose, and Throat Diseases 4.2 Respiratory Diseases 4.3 Cardiovascular Diseases 4.4 Blood and Lymphatic Diseases

5 General Diagnosis: Clinical Impression — GI, GU, Endocrine

5.1 Gastrointestinal Diseases 5.2 Genitourinary Diseases 5.3 Endocrine and Metabolic Disorders

6 General Diagnosis: Clinical Impression — Immune, Nutrition, Infection

6.1 Immunological Disorders 6.2 Nutritional Disorders 6.3 Infectious Diseases

7 NMS Diagnosis: History, Posture, and Cervical/Thoracic Orthopedics

7.1 NMS Case History 7.2 Posture and Gait Assessment 7.3 Orthopedic Examination: Cervical Spine 7.4 Orthopedic Examination: Thoracic Spine

8 NMS Diagnosis: Lumbar/Extremity Orthopedics and Neuro Exam Basics

8.1 Orthopedic Examination: Lumbar Spine and Pelvis 8.2 Orthopedic Examination: Extremities 8.3 Neurologic Examination: Cranial Nerve and CNS Testing 8.4 Neurologic Examination: Motor and Sensory Testing

9 NMS Diagnosis: Reflexes, CNS, and Peripheral Disorders

9.1 Neurologic Examination: Reflex Testing 9.2 Diagnosis: CNS Disorders 9.3 Diagnosis: Peripheral Neurologic and Neurovascular Disorders

10 NMS Diagnosis: Muscular and Bone/Joint Disorders

10.1 Diagnosis: Muscular Disorders 10.2 Diagnosis: Bone and Joint Disorders

11 Diagnostic Imaging: Technology and Positioning

11.1 Imaging Technology 11.2 Radiographic Positioning and Normal Anatomy: Spine and Pelvis 11.3 Radiographic Positioning and Normal Anatomy: Extremities, Thorax, and Abdomen

12 Diagnostic Imaging: Congenital, Trauma, Arthritis, Tumors

12.1 Congenital Anomalies and Normal Variants 12.2 Trauma 12.3 Arthritides 12.4 Tumors and Tumor-like Processes

13 Diagnostic Imaging: Metabolic, Infectious, and Visceral Findings

13.1 Nutritional, Metabolic, Endocrine, and Hematologic Imaging Findings 13.2 Infectious and Miscellaneous Skeletal Conditions 13.3 Thoracic and Abdominal Imaging Conditions

14 Diagnostic Imaging: Interpretation Methods and Special Imaging

14.1 Methods of Interpretation 14.2 Clinical Applications of Special Imaging

15 Principles of Chiropractic: Paradigm and Subluxation Models

15.1 The Chiropractic Paradigm 15.2 Subluxation Models: Neural and Reflex Theories 15.3 Subluxation Models: Vascular, Trophic, Immune, and Biomechanical

16 Principles of Chiropractic: Basic Science and Applied Principles

16.1 Basic Science Concepts in Chiropractic 16.2 Applied Chiropractic Principles

17 Chiropractic Practice: Analysis, Technique, and Case Management

17.1 Spinal Analysis and Patient Evaluation 17.2 Chiropractic Adjustive Technique: Cervical and Thoracic 17.3 Chiropractic Adjustive Technique: Lumbar, Pelvic, Costal, and Extremity 17.4 Patient Care: Case Management and Contraindications

18 Chiropractic Practice: Rehab, Community, and Occupational Health

18.1 Patient Care: Home Care, Prevention, and Rehabilitation 18.2 Community Health and Wellness 18.3 Occupational and Environmental Health

19 Associated Clinical Sciences: Geriatrics, Dermatology, and STDs

19.1 Geriatrics 19.2 Dermatology 19.3 Sexually Transmitted Diseases

20 Associated Clinical Sciences: Toxicology, Emergency, and Psychology

20.1 Toxicology 20.2 Emergency Procedures 20.3 Psychology

21 Associated Clinical Sciences: OB/GYN, Pediatrics, and Jurisprudence

21.1 Gynecology and Obstetrics 21.2 Pediatrics 21.3 Jurisprudence, Ethics, and Basic Economics

11.1 Imaging Technology

Key Takeaways Explain This Topic AI

X-ray image quality depends on technique factors — kVp controls beam penetration and contrast, mAs controls the number of photons and overall image density, and SID/OID affect magnification and sharpness.

Digital radiography (DR) uses flat-panel detectors for immediate image display; computed radiography (CR) uses photostimulable phosphor plates that require a separate reader — both replace film-screen systems.

The ALARA principle (As Low As Reasonably Achievable) governs radiologic protection through justification of every exposure, optimization of technique, and shielding for staff and patients.

Operator protection relies on time, distance, and shielding; the inverse square law means doubling distance from the source reduces radiation intensity to one-fourth.

Common image quality faults include overexposure (too dark), underexposure (too light), motion blur, scatter fog, grid cutoff, and poor collimation — each has a distinct cause and corrective action.

Last updated: July 2026

11.1 Imaging Technology

Quick Answer: NBCE Part II expects you to understand how X-rays are produced and how technique factors (kVp, mAs, SID, OID) shape image quality, how digital and computed radiography systems work, the ALARA radiation-protection framework, and how to recognize common quality faults such as overexposure, motion blur, and scatter fog.

X-Ray Physics and Image Formation

Diagnostic radiography uses ionizing radiation — photons with enough energy to remove electrons from atoms as they pass through tissue. An X-ray tube generates photons when electrons accelerated from the cathode strike a tungsten anode (the target). The resulting beam exits through a window and passes through the patient before reaching an image receptor.

As photons traverse the body, they are attenuated (absorbed or scattered) at different rates depending on tissue density and atomic number. Bone (high atomic number, dense) absorbs more photons than soft tissue; air absorbs very little. This differential attenuation creates the contrast pattern that forms the radiographic image — dense structures appear radiopaque (white/light), air-filled structures appear radiolucent (dark), and soft tissues fall between.

Two types of interaction matter for image quality:

Photoelectric effect : photon is fully absorbed; contributes to useful image contrast

Compton scatter : photon changes direction with partial energy loss; degrades image contrast by adding fog to the receptor

Scatter increases with thicker body parts, higher kVp, and larger field size — which is why collimation (restricting the beam to the anatomy of interest) is both a quality and a safety measure.

Technique Factors

Four primary variables control the radiographic exposure:

Factor What It Controls Clinical Effect

kVp (kilovoltage peak) Beam energy/penetration Higher kVp = more penetration, lower contrast, more scatter; lower kVp = less penetration, higher contrast

mAs (milliampere-seconds) Total number of photons produced Directly proportional to receptor exposure (density); doubling mAs doubles image density

SID (source-to-image distance) Distance from tube to receptor Standard is 40 inches (102 cm) for most extremity and spine work; longer SID reduces magnification and geometric unsharpness

OID (object-to-image distance) Distance from patient to receptor Greater OID increases magnification and unsharpness — keep the patient as close to the receptor as practical

The 15% rule is a useful adjustment guide: increasing kVp by 15% while halving mAs maintains approximately the same receptor exposure but alters contrast. Part II may test whether you understand that mAs is the primary density control while kVp is the primary contrast and penetration control .

Radiographic Imaging Systems

Modern chiropractic offices use digital systems that have largely replaced film-screen radiography:

Computed Radiography (CR) : uses photostimulable phosphor (PSP) plates inside cassettes. After exposure, the cassette is fed into a reader that laser-stimulates the plate and digitizes the signal. CR offers digital workflow but requires plate handling and reader processing time.

Direct Digital Radiography (DR) : uses flat-panel detectors (either indirect with scintillator + photodiode array, or direct with amorphous selenium). Images appear on screen within seconds — no cassette reader step. DR generally offers higher detective quantum efficiency (DQE) and lower dose for equivalent image quality.

Both systems allow post-processing — window/level adjustment, edge enhancement, and magnification — which is an advantage over film but can mask technique errors if relied upon too heavily.

Quality Assurance

A structured QA program ensures consistent, diagnostic-quality images and equipment safety:

Daily checks : receptor cleanliness, display monitor calibration, technique chart availability

Weekly/monthly : repeat-rate analysis (percentage of images repeated due to positioning or technique errors — target typically below 5–8%)

Periodic physicist evaluation : beam alignment, kVp/mAs accuracy, half-value layer (HVL) measurement, receptor response uniformity

Documentation : maintain logs of QA results, equipment service records, and technique charts updated for each body part and patient size category

Repeat-rate monitoring is particularly important in chiropractic practice where high-volume spinal radiography is common — a rising repeat rate often signals technique drift, equipment malfunction, or staff training gaps.

Radiologic Protection

Protection is governed by the ALARA principle — As Low As Reasonably Achievable. Every exposure must be justified (clinical benefit outweighs risk), optimized (lowest dose that still answers the clinical question), and limited (only the necessary views and field size).

Operator protection uses three classic strategies:

Time : minimize duration near the active beam; step behind a lead barrier during exposure

Distance : radiation intensity follows the inverse square law — doubling distance from the source reduces intensity to one-fourth

Shielding : lead aprons (minimum 0.25 mm Pb equivalent, preferably 0.5 mm), thyroid collars, lead-glass barriers, and lead-lined walls in the X-ray room

Patient protection includes:

  • Tight collimation to the region of interest
  • Gonadal and thyroid shielding when it does not obscure diagnostic anatomy
  • Appropriate technique selection (avoid excessive mAs or repeat exposures)
  • Pregnancy screening before any ionizing study in patients of childbearing potential

Occupational dose limits for radiation workers are set by regulatory bodies (typically 50 mSv/year whole-body effective dose in the United States under ALARA oversight, with a 5-year average of 20 mSv/year). Patient doses from individual plain-film studies are much lower — a chest X-ray delivers roughly 0.02 mSv, while a lumbar spine series may deliver 1–2 mSv.

Common Image Quality Faults

Recognizing faults and their causes is a high-yield Part II topic:

  • Fault Appearance Common Cause
  • Overexposure Image too dark (high density) Excessive mAs or kVp; incorrect automatic exposure control setting
  • Underexposure Image too light (low density) Insufficient mAs or kVp; wrong technique chart entry
  • Motion blur Loss of edge sharpness, streaking Patient movement, breathing, or long exposure time

Scatter fog Overall gray haze, reduced contrast Large field size, high kVp, thick body part without adequate grid use

Grid cutoff Uniform or graduated loss of density across image Grid not centered to the beam, incorrect SID, or upside-down grid

Poor collimation Unnecessary anatomy exposed; increased scatter Light field not aligned with radiation field; field too large

Quantum mottle Grainy, speckled appearance Insufficient mAs (underexposure) in digital systems

Geometric distortion Magnification or shape distortion Short SID, excessive OID, or angled beam relative to receptor

When a fault is identified, the corrective action targets the root cause — not simply re-processing the image. A motion-blurred cervical lateral requires re-positioning and coaching the patient on breath-hold, not increasing mAs.