Study guide
3.4 Infection Control and Precautions
NBRC Certified Respiratory Therapist CRT
Track your progress as you read
Finished sections get a check mark.
1 CRT Pathway and TMC Exam Strategy
1.1 Current CRT and TMC Exam Facts 1.2 Eligibility, Application, and PSI Scheduling 1.3 Low Cut, High Cut, and the RRT Pathway 1.4 Three-Hour TMC Pacing Plan
2 Patient Data Evaluation
2.1 Assessment and Trend Recognition 2.2 ABG, Oxygenation, and Ventilation Data 2.3 Labs, ECG, Imaging, and PFT Clues 2.4 Turning Data Into Recommendations 2.5 Patient Data Practice Routine
3 Equipment, Quality Control, and Infection Control
3.1 Oxygen Devices and Cylinder Safety 3.2 Ventilator Alarms and Circuit Troubleshooting 3.3 Humidification, Aerosol Delivery, and Device Quality Control 3.4 Infection Control and Precautions
4 Initiation and Modification of Interventions
4.1 Oxygen Therapy and Noninvasive Support 4.2 Airway Clearance and Lung Expansion 4.3 Aerosol Medications and Gas Therapy 4.4 Artificial Airways and Suctioning 4.5 Mechanical Ventilation Initiation and Adjustment 4.6 Weaning, Emergencies, and Special Procedures
5 Timed TMC Integration and Credential Maintenance
5.1 Mixed-Domain Case Strategy 5.2 Final Two-Week Remediation Plan 5.3 Test-Day Safety and Ethics 5.4 After CRT: CMP and Next Steps
3.4 Infection Control and Precautions
Key Takeaways Explain This Topic AI
Standard Precautions apply to EVERY patient and include hand hygiene plus PPE chosen by anticipated exposure (blood/body-fluid, splash, soiling).
Contact = gown + gloves; Droplet = surgical mask within ~3-6 feet; Airborne = fit-tested N95 (or PAPR) plus an airborne infection isolation room (negative pressure, ≥6-12 air changes/hour).
Spaulding classification drives reprocessing: noncritical items get low/intermediate disinfection, semicritical (mucous-membrane contact) get high-level disinfection, critical (sterile tissue) get sterilization.
C. difficile and other spore-formers require SOAP-AND-WATER hand hygiene because alcohol-based rub does not kill spores; aerosol-generating procedures warrant airborne-level protection.
Last updated: June 2026
Infection Control on the TMC
Infection-control items are NOT separate from equipment safety — they share the official Troubleshooting and Quality Control of Devices / Infection Control domain, 20 of 140 scored items (~14%) . Most stems ask one of two things: what protection is needed before entering the room , or how a respiratory device should be cleaned before reuse . Answer from transmission route and device contact level , not from how sick the patient appears.
Standard Precautions
Standard Precautions apply to all patients regardless of diagnosis. They include hand hygiene before and after contact, gloves for blood/body-fluid contact, and a mask, eye protection, and/or gown when splashes, sprays, or soiling are reasonably anticipated. Because respiratory therapists carry shared equipment between rooms — stethoscopes, pulse-oximeter probes, spacers, masks, transport ventilators, bag-valve-mask devices — cleaning between patients is part of Standard Precautions.
Transmission-Based Precautions
- Precaution Route PPE and Room Respiratory Example
- Contact Touch / contaminated surfaces Gown + gloves MRSA wound, VRE, draining secretions
Enteric (special) contact Spore-forming GI organisms Gown, gloves, SOAP-AND-WATER hygiene C. difficile after antibiotics
Droplet Large droplets (~within 3-6 ft) Surgical mask; eye protection per policy Influenza, pertussis, Neisseria meningitis
Airborne Small particles that stay suspended Fit-tested N95 or PAPR; negative-pressure AIIR Tuberculosis, measles, varicella
Airborne + Contact Airborne spread plus lesion contact N95 + gown + gloves Disseminated zoster, smallpox
An airborne infection isolation room (AIIR) is a negative-pressure room with ≥6-12 air changes per hour , exhausted outside or HEPA-filtered, with the door kept closed.
Quick Comparison
- Decision Point Contact Droplet Airborne
- Main spread Hands, surfaces, environment Coughing/sneezing at close range Suspended micro-particles
- Typical mask Per splash risk Surgical mask Fit-tested N95 or higher
- Room Private if uncontrolled drainage Private or cohort per policy Negative-pressure AIIR
Equipment emphasis Dedicated/disinfected shared tools Mask patient during transport Limit aerosol-generating exposure
Common exam miss Forgetting gown AND gloves Choosing N95 for plain influenza Using a surgical mask for suspected TB
Hand Hygiene
Alcohol-based hand rub (ABHR) is appropriate for most routine encounters when hands are not visibly soiled and is faster and more effective than soap for vegetative bacteria. Soap and water is required when hands are visibly dirty and is preferred after caring for C. difficile or other spore-formers , because alcohol does not kill spores — only the mechanical action of washing removes them. Follow the WHO "5 Moments" : before touching the patient, before an aseptic task, after body-fluid exposure risk, after touching the patient, and after touching the patient environment. Gloves do NOT replace hand hygiene.
Donning and Doffing Order
Don: gown, then mask/respirator, then goggles/face shield, then gloves.
Doff: gloves, then goggles/face shield, then gown, then mask/respirator — performing hand hygiene as you go and removing the respirator LAST, outside the room when airborne precautions apply.
Aerosol-generating procedures (open suctioning, bronchoscopy, nebulized therapy, intubation, manual ventilation) increase exposure risk and warrant respirator-level protection when an airborne pathogen is suspected.
Equipment Reprocessing — the Spaulding Classification
The Spaulding classification ranks devices by infection risk and dictates the minimum processing level:
Spaulding Class Tissue Contact Minimum Processing Respiratory Examples
Noncritical Intact skin Low/intermediate-level disinfection Stethoscope, BP cuff, ventilator surfaces, reusable O2 mask
Semicritical Mucous membranes / non-intact skin HIGH-level disinfection (or sterilization) Flexible bronchoscope, laryngoscope blades, nasopharyngeal airways
Critical Sterile tissue / vascular system STERILIZATION Surgical airway instruments, items entering the bloodstream
- Equipment Class Concept Exam Warning
- Stethoscope diaphragm Noncritical Disinfect between patients Don't move room-to-room without cleaning
Reusable O2 mask between patients Noncritical Facility-approved disinfection before reuse "Patient-specific" is not "reusable forever"
Reusable nebulizer, same patient Patient-care item Clean, rinse, dry, store per policy Standing water grows organisms
Flexible bronchoscope Semicritical High-level disinfection or sterilization Leak-test meticulously before reprocessing
- Surgical airway instrument Critical Sterilization High-level disinfection is NOT enough
- Respiratory Infection Traps
Moist environments breed microbes: do not top off humidifier water (drain and refill), do not leave nebulizer reservoirs wet between treatments, and never drain ventilator condensate toward the patient. Replace filters, suction systems, and disposables per policy and when visibly soiled. Closed (in-line) suction preserves PEEP and limits circuit breaks but still requires aseptic technique; open suctioning of the lower airway requires sterile technique because the catheter enters a normally sterile airway.
TMC Decision Pattern
When the stem names a disease, match the route first (TB → airborne; influenza → droplet; MRSA → contact). When it names equipment, ask what tissue it contacts (mucous membrane → high-level disinfection). When it describes diarrhea after antibiotics , think C. difficile → enteric contact precautions and soap-and-water hand hygiene.