Study guide

8.5 NAVA, Edi & Proportional Support

NBRC RRT-NPS Neonatal/Pediatric Specialist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Neonatal and Pediatric Patient Assessment

1.1 Maternal, Obstetric & Perinatal History 1.2 Fetal Surveillance & Antepartum Diagnostics 1.3 Gestational Age & Baseline Neonatal Examination 1.4 Apgar, Respiratory Distress & Thoracic Assessment 1.5 Pediatric Assessment Triangle & Vital Signs 1.6 Neurologic Assessment, Respiratory Failure & Triage

2 Chapter 2: Diagnostic Evaluation & Gas Exchange Monitoring

2.1 Pulse Oximetry, Pre/Postductal & Transcutaneous Monitoring 2.2 Capnography, Waveforms & Dead-Space Evaluation 2.3 Arterial & Capillary Blood-Gas Sampling 2.4 Umbilical Lines, Acid-Base & Laboratory Evaluation 2.5 Chest Imaging & Airway Radiography 2.6 Pulmonary Function, Bronchoscopy & Specimen Diagnostics

3 Chapter 3: Airway Management & Secretion Clearance

3.1 Pediatric Airway Anatomy & ETT Sizing 3.2 Cuffed Airways, Intubation & Difficult-Airway Management 3.3 Tracheostomy Devices & Routine Care 3.4 Tracheostomy Emergencies, Speaking & Decannulation 3.5 Airway Suctioning Technique & Safety 3.6 Airway Clearance, Home Care & Discharge Planning

4 Chapter 4: Pharmacology & Medical Gas Therapy

4.1 Aerosol Physics & Delivery Devices 4.2 Respiratory & Systemic Pharmacology 4.3 Oxygen Interfaces & Delivery Systems 4.4 Oxygen Blenders, Targets & Toxicity 4.5 HFNC Physiology, Sizing & Flow 4.6 HFNC Indications, Monitoring & Escalation

5 Chapter 5: Shared Neonatal & Pediatric Pulmonary Disorders

5.1 Neonatal RDS Pathophysiology & Management 5.2 TTN, Pneumonia & the Neonatal Differential 5.3 Meconium Aspiration & PPHN 5.4 BPD, Apnea & Chronic Neonatal Lung Disease 5.5 Bronchiolitis, Croup & Epiglottitis 5.6 Asthma, Cystic Fibrosis & Foreign-Body Aspiration

6 Chapter 6: Resuscitation, Emergency Protocols & Patient Safety

6.1 NRP Cord Management, Initial Steps & Ventilation 6.2 NRP Corrective Steps, Compressions & Medications 6.3 PALS Assessment, CPR & Cardiac Arrest 6.4 PALS Dysrhythmia & Shock Management 6.5 Neonatal & Pediatric Transport 6.6 Patient Safety, Teamwork & Family-Centered Care

7 Chapter 7: Noninvasive & Conventional Mechanical Ventilation

7.1 Bubble CPAP & Neonatal NIV 7.2 Pediatric NIV, Interfaces & Failure Recognition 7.3 Conventional Ventilation Physics & Modes 7.4 Initial Settings & ABG-Guided Titration 7.5 Ventilator Scalars & Loops 7.6 Ventilator Dyssynchrony & Troubleshooting 7.7 Weaning Readiness & Spontaneous Breathing Trials 7.8 Extubation & Post-Extubation Airway Risk

8 Chapter 8: High-Frequency Ventilation & Advanced Modes

8.1 HFOV Mechanics & Gas Transport 8.2 HFOV Controls & Clinical Management 8.3 HFJV Circuit & Controls 8.4 HFJV Servo Pressure & Clinical Indications 8.5 NAVA, Edi & Proportional Support 8.6 APRV in Pediatric Respiratory Failure

9 Chapter 9: Specialty Inhaled Gases & Exogenous Surfactant Therapy

9.1 Inhaled Nitric Oxide: Mechanism, Indications & Dose 9.2 Inhaled Nitric Oxide: Toxicity, Monitoring & Weaning 9.3 Heliox Physics & Delivery 9.4 Volatile Anesthetic & Subambient Gas Therapy 9.5 Surfactant Biology, Products & Dosing 9.6 Surfactant Administration & Response

10 Chapter 10: Pediatric ARDS & Parenchymal Critical Illness

10.1 PALICC-2 Diagnosis & Severity 10.2 PALICC-2 NIV & Possible PARDS 10.3 PARDS Lung-Protective Ventilation 10.4 PARDS Refractory Hypoxemia & Adjuncts 10.5 PIE & Pneumothorax Recognition 10.6 Thoracic Decompression & Chest Drains

11 Chapter 11: Congenital Heart Disease & Hemodynamic Management

11.1 Left-to-Right Shunts & Qp/Qs Physiology 11.2 Acyanotic Lesions & Respiratory Management 11.3 Cyanotic Lesions & the Five Ts 11.4 Ductal Dependence, PGE1 & the Hyperoxia Test 11.5 Single-Ventricle Physiology & Staged Palliation 11.6 Gas Balancing, Hemodynamics & NIRS

12 Chapter 12: Advanced Critical Care: ECMO, Neurotrauma & Palliative Care

12.1 ECMO Candidacy & Modality 12.2 ECMO Circuit, Lung Rest & Anticoagulation 12.3 Neurotrauma, ICP & Ventilation 12.4 Neonatal Therapeutic Hypothermia & Respiratory Care 12.5 Death by Neurologic Criteria: Examination & Apnea Testing 12.6 DNC Timing, Ancillary Testing, Palliation & Donation

8.5 NAVA, Edi & Proportional Support

Key Takeaways Explain This Topic AI

NAVA captures the Electrical Activity of the Diaphragm (Edi) in microvolts (uV) via an array of miniature bipolar electrodes on a specialized nasogastric/orogastric catheter, providing a signal that reflects neural respiratory drive and diaphragmatic activation.

NAVA uses the diaphragmatic electrical signal for triggering, proportional assist, and cycling, so synchrony is often less disrupted by pneumatic leaks; catheter position, signal quality, apnea, and neuromuscular blockade still matter.

Delivered airway pressure is governed by the equation: Airway Pressure = PEEP + (NAVA Level x [Edi_peak - Edi_min]), where the clinician-set NAVA level (cmH2O/uV) acts as a proportional amplification factor.

Last updated: September 2026

8.5 NAVA, Edi & Proportional Support

Patient-ventilator dyssynchrony can increase work of breathing, discomfort, sedation exposure, and ineffective ventilation in neonatal and pediatric intensive care. Conventional pneumatic modes rely on pressure or flow sensors located in the ventilator or proximal circuit. In infants with compliant chest walls, high airway resistance, rapid respiratory rates, and uncuffed endotracheal tubes, pneumatic triggering is notoriously vulnerable to auto-triggering (from circuit leaks or cardiogenic oscillation) or missed triggers (inability of weak inspiratory efforts to overcome intrinsic PEEP).

Neurally Adjusted Ventilatory Assist (NAVA) and advanced proportional modes bypass pneumatic limitations by coupling the ventilator directly to the patient's neurological respiratory drive.

Electrophysiological Foundations of NAVA

NAVA uses the patient's own central neural drive to dictate the onset, size, and termination of each assisted breath. The physiological sequence operates as follows: +-----------------------------------------------------------------------------+

  • | THE NAVA NEURO-VENTILATORY AXIS |
  • +-----------------------------------------------------------------------------+
  • | |
  • | 1. Respiratory Center (Medulla / Pons) |
  • | | |
  • | v |
  • | 2. Phrenic Nerve Conduction |
  • | | |
  • | v |
  • | 3. Diaphragmatic Depolarization (Action Potentials at Crural Motor Units) |
  • | | |
  • | v |
  • | 4. Edi Catheter Detection (Miniature Bipolar Electrodes) |
  • | | |
  • | v |
  • | 5. Microprocessor Amplification (Proportional Pressure Delivery) |
  • | |
  • +-----------------------------------------------------------------------------+

Because diaphragmatic electrical activity precedes the pneumatic pressure or flow change, NAVA can reduce trigger delay and improve synchrony. Actual delay and proportionality depend on catheter position, signal processing, ventilator, apnea settings, leak, and the patient's neural drive; they are not guaranteed to be below one universal millisecond value.

The Edi Catheter: Sizing, Insertion & Anatomical Verification

The Edi catheter is a medical-grade feeding tube (available in sizes 6 to 16 French 6\text{ to }16\text{ French} 6 to 16 French ) equipped with an array of 9 miniature ring electrodes that form 8 sequential bipolar electrode pairs near its distal tip. +-----------------------------------------------------------------------------+

  • | EDI CATHETER POSITIONING SCREEN CRITERIA |
  • +------------------------------------+----------------------------------------+
  • | Anatomical Channel | Electrophysiological Signal Profile |
  • +------------------------------------+----------------------------------------+

| Positioning display | Interpret the catheter’s ECG lead pattern and the device’s Edi-position highlight together. |

+------------------------------------+----------------------------------------+

| Expected transition | P-wave visibility and QRS amplitude change as electrodes cross the diaphragm; the exact highlighted leads depend on catheter position and system display. |

+------------------------------------+----------------------------------------+

| Confirmation | Follow the current ventilator and catheter manual, then verify a stable Edi signal and feeding-tube position before use. |

  • +------------------------------------+----------------------------------------+
  • Insertion & Verification Technique

Depth Estimation: Catheter insertion depth is estimated using the modified Nose-Ear-Xiphoid (NEX) distance formula or manufacturer nomograms based on crown-to-rump length and weight.

The 4-Channel Verification Window: On the ventilator interface (e.g., Getinge Servo-u / Servo-n), the system displays four real-time bipolar electromyographic tracings derived from the electrode pairs.

Confirm position: Use the manufacturer’s Edi catheter positioning screen: evaluate which leads are highlighted, the direction of P-wave and QRS changes across the electrode array, signal stability, and the system’s on-screen guidance.

Correct malposition: Advance or withdraw only according to the device display and catheter instructions, then reconfirm both Edi signal and feeding-tube position. Do not infer direction from a memorized color rule that may differ by display or software version.

Clinical Metrics of the Edi Signal

The E d i Edi E d i signal is quantified in microvolts ( μ V \mu\text{V} μ V ) and continuously monitored as two distinct clinical values: Microvolts (uV)

  • ^
  • | /\ /\
  • Peak |---- / \ / \ <-- Edi_peak (Effort / Drive)
  • | / \ / \
  • | / \ / \
  • Min |---- /________\ /________\ <-- Edi_min (Tonic Activity)
  • +--------------------------------------------------> Time
  • 1. E d i peak Edi_{\text{peak}} E d i peak ​ (Peak Diaphragmatic Activity)

Definition: The maximum electrical activity recorded during the inspiratory phase of neural breathing.

Clinical Significance: Reflects the total neural respiratory drive generated by the brainstem. It represents the patient's physical effort to breathe.

Interpretation: There is no universal normal Edi_peak target. Trend the patient’s own signal with respiratory effort, comfort, tidal volume, gas exchange, sedation, neural disease, catheter position, and changes in support. A low value may reflect over-assistance, low drive, medication, weakness, or signal loss; a high value may reflect load, distress, insufficient assist, agitation, or artifact.

2. E d i min Edi_{\text{min}} E d i min ​ (Tonic Diaphragmatic Activity)

Definition: The baseline electrical activity recorded during the expiratory pause.

Clinical Significance: Represents basal diaphragmatic tone. In neonates, active tonic contraction of the crural diaphragm prevents end-expiratory alveolar collapse and preserves functional residual capacity (FRC).

Interpretation: Edi_min varies with age, lung volume, sleep, support, and signal quality; use trends rather than a universal normal range.

Machine Controls & The NAVA Proportional Assist Equation

In NAVA, the clinician does not set an inspiratory pressure or tidal volume. Instead, the clinician sets the NAVA Level , which acts as a proportional multiplier: Delivered Airway Pressure = PEEP + ( NAVA Level × [ E d i peak − E d i min ] ) \text{Delivered Airway Pressure} = \text{PEEP} + (\text{NAVA Level} \times [Edi_{\text{peak}} - Edi_{\text{min}}]) Delivered Airway Pressure = PEEP + ( NAVA Level × [ E d i peak ​ − E d i min ​ ])

Where:

Airway Pressure: Instantaneous pressure delivered at the airway opening ( cmH 2 O \text{cmH}_2\text{O} cmH 2 ​ O ).

PEEP: Positive end-expiratory pressure set by the clinician ( cmH 2 O \text{cmH}_2\text{O} cmH 2 ​ O ).

NAVA Level: Proportional assist factor set in units of cmH 2 O / μ V \text{cmH}_2\text{O} / \mu\text{V} cmH 2 ​ O / μ V (selected and titrated using the manufacturer’s method, the patient’s response, and the local protocol).

E d i peak − E d i min Edi_{\text{peak}} - Edi_{\text{min}} E d i peak ​ − E d i min ​ : Net neural drive for that individual breath ( μ V \mu\text{V} μ V ). +-----------------------------------------------------------------------------+

  • | NAVA PROPORTIONAL ASSIST DYNAMICS |
  • +-----------------------------------------------------------------------------+
  • | |
  • | Quiet, Resting Breath (Edi = 6 uV) --> Low Pressure Assist Delivered |
  • | Deep, Stressed Breath (Edi = 18 uV) --> High Pressure Assist Delivered |
  • | Cough / Sigh (Edi = 25 uV) --> Maximum Assist (Up to P_max) |
  • | |
  • +-----------------------------------------------------------------------------+
  • Cycling Mechanics: Neural Cycling-Off

Conventional pressure support often cycles when inspiratory flow falls to a set fraction of peak flow, which can be disrupted by leak. NAVA cycles from the fall in Edi; some Servo implementations use a default around 70% of peak Edi. Verify the ventilator software and settings rather than treating that percentage as universal or equating it exactly with cessation of neural drive.

Safety Settings & Back-Up Ventilation

Upper Pressure Limit ( P max P_{\text{max}} P max ​ ): An essential safety parameter set to prevent excessive pressure delivery during high E d i Edi E d i spikes (e.g., crying, vigorous coughing). Set the upper pressure limit and alarms according to the current ventilator instructions; verify how that model limits NAVA pressure rather than assuming one offset.

Apnea Back-Up Ventilation: If the E d i Edi E d i signal is lost due to catheter displacement, central apnea, or administration of neuromuscular blocking agents, the ventilator can transition after the configured apnea interval to preset backup ventilation. Verify apnea time, backup settings, alarms, and the model-specific transition.

Noninvasive NAVA (NIV-NAVA)

NAVA can be delivered noninvasively via nasal prongs, nasal masks, or a RAM cannula. Because neural triggering and cycling do not depend on a pneumatic leak signal, NIV-NAVA can improve synchrony despite substantial interface leak. Leak still affects pressure transmission, oxygen delivery, monitoring, comfort, and backup ventilation, so it must be assessed and managed.