Study guide
8.3 Constructed Wetlands & Natural Treatment Systems
North Carolina Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: North Carolina Regulatory Framework, Certification & Classification
1.1 Dual Regulatory Structure: WTFOCB, WPCSOCC & NC DEQ 1.2 Drinking Water Certification Grades, Eligibility & the Apprentice Pathway 1.3 Examinations, Fees, Renewal, Continuing Education & Discipline 1.4 Classifying Drinking Water Facilities: Rating Values, Classes & Required Operators 1.5 Classifying Water Pollution Control Systems Under 15A NCAC 08G .0300 1.6 Wastewater Certification Types, Experience Ladders, OIT & Reciprocity
2 Chapter 2: Operator in Responsible Charge, Oversight & Regulatory Reporting
2.1 Designating the ORC and Back-up ORC: Forms, Deadlines & Legal Duties 2.2 Mandatory Visitation Frequencies & Facility Oversight 2.3 Operational Logs, Records Retention & Compliance Reporting 2.4 Sanitary Sewer Overflows: Reporting, Press Releases & Public Notice 2.5 The Federal Drinking Water Rule Framework Operators Are Tested On
3 Chapter 3: Drinking Water Treatment: Source Water Through Filtration
3.1 Source Water Quality, Raw Water Intake & Rapid Mixing 3.2 Coagulation Chemistry, Flocculation & Sedimentation Basins 3.3 Granular Media Filtration, Head Loss & Backwash Protocols 3.4 Taste and Odor Control, Powdered Activated Carbon & Algae Management
4 Chapter 4: Disinfection, Chemical Conditioning & Advanced Water Treatment
4.1 Chlorination Chemistry, Breakpoint Chlorination & CT Disinfection Inactivation 4.2 Disinfection Byproducts (TTHM & HAA5), Stage 1/2 DBPR & Enhanced Coagulation 4.3 Corrosion Control, Lead & Copper Rule Revisions, Fluoridation & Groundwater Treatment 4.4 Iron and Manganese Control: Oxidation, Greensand & Sequestration 4.5 Softening, Ion Exchange & Membrane Treatment 4.6 Water Plant Residuals, Backwash Recovery & Waste Disposal
5 Chapter 5: Groundwater Sources, Wells & Small Water Systems
5.1 Well Hydrology, Aquifers & North Carolina Well Construction Standards 5.2 Well Pumps, Wellhead Equipment & Source Protection 5.3 Small Water System Operations, Administration & Plant Recordkeeping
6 Chapter 6: Water Distribution Systems, Storage & Cross-Connection Control
6.1 Water Distribution Hydraulics, Storage Facilities & Water Quality Maintenance 6.2 Water Use, Demand Patterns & Distribution System Design 6.3 Pipe Materials, Main Installation, Service Connections & Meters 6.4 Fire Hydrants, Valve Operation & Distribution Operational Practices 6.5 Pump Hydraulics, Valve Operation & Cross-Connection Control / Backflow Prevention 6.6 System Mapping, Records & Information Management 6.7 Utility Security, Emergency Response & Boil Water Advisories
7 Chapter 7: Instrumentation, Electrical Fundamentals, Maintenance & Microbiological Monitoring
7.1 Instrumentation, Electrical Fundamentals & SCADA 7.2 Preventive Maintenance, Pumps, Motors & Mechanical Equipment 7.3 Bacteriology, Sample Siting Plans & RTCR Compliance Sampling
8 Chapter 8: Biological Wastewater Treatment & Secondary Processes
8.1 Wastewater Characterization, Preliminary Screening & Primary Clarification 8.2 Wastewater Lagoons, Stabilization Ponds & Operational Control 8.3 Constructed Wetlands & Natural Treatment Systems 8.4 Septic Tanks, Media Filters, Aerobic Treatment Units & Grease Interceptors 8.5 Attached Growth Systems: Trickling Filters, RBCs & Fixed-Film Processes 8.6 Activated Sludge Microbiology, Aeration Basins & Secondary Clarifiers 8.7 Operational Process Control: F/M Ratio, MCRT / Sludge Age & SVI
9 Chapter 9: Nutrient Removal, Solids Handling & Effluent Management
9.1 Biological Nutrient Removal (BNR) in NC Nutrient-Sensitive Waters (NSW) 9.2 Sludge Stabilization, Aerobic/Anaerobic Digestion & Biosolids Management 9.3 Digester Gas Systems, Heating, Mixing & Explosion Safety 9.4 Composting, Thermal Drying & Alternative Solids Disposal 9.5 Odor Sources, Measurement & Control Technologies 9.6 Tertiary Filtration, Reclaimed Water & Reuse Under 15A NCAC 02U 9.7 Effluent Disinfection, Dechlorination & NPDES Permit Compliance
10 Chapter 10: Wastewater Collection Systems, Lift Stations & Field Operations
10.1 Wastewater Collection System Design, Lift Stations & Inflow and Infiltration (I/I) 10.2 Manholes, Service Taps, Laterals & Sewer Construction Practice 10.3 Sewer Cleaning, Root Control & Preventive Maintenance Programs 10.4 Collection System Inspection & Acceptance Testing 10.5 Job-Site Pre-Planning, Traffic Control & Field Work Safety
11 Chapter 11: Industrial Pretreatment & Physical/Chemical Treatment
11.1 Industrial Pretreatment Programs & Protecting the POTW 11.2 Physical/Chemical Treatment Processes for Industrial Wastewater 11.3 Groundwater Remediation Systems, Flow Equalization & Flow Measurement
12 Chapter 12: Laboratory, Safety, Utility Management & Applied Mathematics
12.1 Laboratory Analytical Methods, Sampling Procedures & QA/QC 12.2 Chemical Safety, Gaseous Chlorine Handling & Hazard Communication 12.3 Permit-Required Confined Space Entry & Excavation / Trenching Safety 12.4 Electrical Safety, Lockout/Tagout & Machine Guarding 12.5 Biological Hazards, PPE, Heat Stress & Personal Hygiene 12.6 Applied Water & Wastewater Mathematics & Process Calculations 12.7 Process Control Mathematics: Loading, Efficiency, Removal & Solids 12.8 Hydraulics, Pressure & Unit Conversion Mathematics 12.9 Utility Management: Personnel, Budgeting, Public Relations & Plant Security
8.3 Constructed Wetlands & Natural Treatment Systems
Key Takeaways Explain This Topic AI
Constructed wetlands and their appurtenances are classified as Grade I biological water pollution control systems under 15A NCAC 08G .0302(a).
Free water surface wetlands expose open water and are effective for polishing, while subsurface flow wetlands keep water below a gravel bed surface, avoiding mosquito habitat and public contact.
Treatment occurs through sedimentation, filtration, microbial attached growth on media and root surfaces, plant uptake, and adsorption — not primarily through the plants themselves.
Wetlands are polishing systems: they require preliminary and primary or secondary treatment upstream and perform poorly when loaded with raw solids that clog the bed.
Operational control is mostly hydraulic — managing water level, flow distribution, short-circuiting, vegetation health, and mosquito and nuisance control — with routine inspection of berms, inlets, and outlet structures.
Last updated: September 2026
8.3 Constructed Wetlands & Natural Treatment Systems
15A NCAC 08G .0302(a)(3) lists "constructed wetlands and associated appurtenances" as Grade I biological systems, and the Biological Grade 1 course dedicates an hour to the topic.
1. Types
Type Water surface Typical use Notes
Free water surface (FWS) Open water above a soil bed Polishing secondary effluent; stormwater; wildlife habitat Public access and mosquito issues; strong TSS and nutrient polishing
Subsurface flow — horizontal (HSSF) Below the surface of a gravel bed Small domestic systems, schools, parks No exposed water; less odor and mosquito risk; clogging is the main failure
Subsurface flow — vertical (VF) Dosed onto the surface, percolates down Higher oxygen transfer; nitrification Requires dosing pumps or siphons
Floating treatment wetlands Plants on floating mats over open water Retrofits into ponds and lagoons Roots provide attached growth surface
2. How treatment actually happens
The plants are the visible part, but most of the work is done by physical and microbial processes:
Sedimentation and filtration of suspended solids in the slow, shallow flow and within the gravel matrix.
Attached microbial growth on gravel, litter, and root surfaces — the same biofilm chemistry as a trickling filter, oxidizing BOD and, where oxygen is available, nitrifying.
Denitrification in anoxic zones deeper in the bed, using the carbon available in the wastewater and plant litter.
Plant uptake of nitrogen and phosphorus — real but modest, and only permanently removed if the biomass is harvested.
Adsorption and precipitation of phosphorus and metals onto media and soils, a finite capacity that eventually saturates.
Typical vegetation: cattail ( Typha ), bulrush ( Schoenoplectus ), soft rush ( Juncus ), and common reed. Plants stabilize the bed, transfer a small amount of oxygen to the root zone, provide surface area, and shade the bed against algae.
3. Design and loading
- Parameter Typical range
- Water depth (FWS) 0.5–1.5 ft
- Bed depth (HSSF) 1.5–2.5 ft of gravel, water level kept 2–4 in below the surface
- Media (HSSF) Washed gravel, commonly 0.75–1.5 in
- Hydraulic retention time 2–10 days
- Length-to-width ratio Commonly 2:1 to 4:1 to limit short-circuiting
- Pretreatment Required — septic tank, primary clarifier, or secondary treatment
Cold weather slows microbial kinetics and can reduce nitrification substantially; North Carolina's climate is favorable, but winter performance should be expected to fall.
4. Operating a wetland
Manage the water level. In an HSSF wetland the level is kept just below the gravel surface using an adjustable outlet — high enough to keep the bed saturated, low enough to prevent surfacing. Surfacing water in an HSSF bed is the first sign of clogging .
Distribute the flow. Inspect and clean inlet manifolds and distribution piping; uneven distribution creates short-circuiting and dead zones. Dye testing confirms actual residence time.
Watch for clogging. Caused by excessive solids from inadequate pretreatment, biomass accumulation, and root growth. Remedies range from resting the bed and adjusting flow to replacing the inlet-zone media — which is why solids removal upstream is non-negotiable.
Vegetation management. Maintain healthy stands, replant bare areas, control invasive species, and harvest where nutrient removal is credited. Do not let woody vegetation establish on berms.
Mosquito and nuisance control. FWS wetlands need mosquito management — water-level manipulation, mosquito fish, or larvicide. Subsurface flow designs avoid the problem entirely, which is why they dominate at schools and parks.
Structures. Inspect berms and liners for erosion and burrowing animals, keep outlet structures free of debris, and confirm that flow measurement devices remain accurate.
5. What wetlands do well — and what they do not
Do well: BOD and TSS polishing, pathogen reduction with adequate retention, nitrogen removal where aerobic and anoxic zones both exist, buffering of flow variations, and very low operating cost and energy use.
Do not do well: handle raw wastewater solids; produce consistently low ammonia in cold weather without a vertical flow or aerated design; remove phosphorus indefinitely (adsorption sites saturate); or tolerate hydraulic overloading, which short-circuits the bed and can wash out accumulated solids.
Note
Reclaimed water and reuse. Where a wetland or other natural system produces effluent destined for reuse, North Carolina's reclaimed water rules in 15A NCAC 02U govern the treatment reliability, monitoring, storage, and permitted uses. A constructed wetland is not by itself a reclaimed water treatment system.