Study guide

2.1 Designating the ORC and Back-up ORC: Forms, Deadlines & Legal Duties

North Carolina Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: North Carolina Regulatory Framework, Certification & Classification

1.1 Dual Regulatory Structure: WTFOCB, WPCSOCC & NC DEQ 1.2 Drinking Water Certification Grades, Eligibility & the Apprentice Pathway 1.3 Examinations, Fees, Renewal, Continuing Education & Discipline 1.4 Classifying Drinking Water Facilities: Rating Values, Classes & Required Operators 1.5 Classifying Water Pollution Control Systems Under 15A NCAC 08G .0300 1.6 Wastewater Certification Types, Experience Ladders, OIT & Reciprocity

2 Chapter 2: Operator in Responsible Charge, Oversight & Regulatory Reporting

2.1 Designating the ORC and Back-up ORC: Forms, Deadlines & Legal Duties 2.2 Mandatory Visitation Frequencies & Facility Oversight 2.3 Operational Logs, Records Retention & Compliance Reporting 2.4 Sanitary Sewer Overflows: Reporting, Press Releases & Public Notice 2.5 The Federal Drinking Water Rule Framework Operators Are Tested On

3 Chapter 3: Drinking Water Treatment: Source Water Through Filtration

3.1 Source Water Quality, Raw Water Intake & Rapid Mixing 3.2 Coagulation Chemistry, Flocculation & Sedimentation Basins 3.3 Granular Media Filtration, Head Loss & Backwash Protocols 3.4 Taste and Odor Control, Powdered Activated Carbon & Algae Management

4 Chapter 4: Disinfection, Chemical Conditioning & Advanced Water Treatment

4.1 Chlorination Chemistry, Breakpoint Chlorination & CT Disinfection Inactivation 4.2 Disinfection Byproducts (TTHM & HAA5), Stage 1/2 DBPR & Enhanced Coagulation 4.3 Corrosion Control, Lead & Copper Rule Revisions, Fluoridation & Groundwater Treatment 4.4 Iron and Manganese Control: Oxidation, Greensand & Sequestration 4.5 Softening, Ion Exchange & Membrane Treatment 4.6 Water Plant Residuals, Backwash Recovery & Waste Disposal

5 Chapter 5: Groundwater Sources, Wells & Small Water Systems

5.1 Well Hydrology, Aquifers & North Carolina Well Construction Standards 5.2 Well Pumps, Wellhead Equipment & Source Protection 5.3 Small Water System Operations, Administration & Plant Recordkeeping

6 Chapter 6: Water Distribution Systems, Storage & Cross-Connection Control

6.1 Water Distribution Hydraulics, Storage Facilities & Water Quality Maintenance 6.2 Water Use, Demand Patterns & Distribution System Design 6.3 Pipe Materials, Main Installation, Service Connections & Meters 6.4 Fire Hydrants, Valve Operation & Distribution Operational Practices 6.5 Pump Hydraulics, Valve Operation & Cross-Connection Control / Backflow Prevention 6.6 System Mapping, Records & Information Management 6.7 Utility Security, Emergency Response & Boil Water Advisories

7 Chapter 7: Instrumentation, Electrical Fundamentals, Maintenance & Microbiological Monitoring

7.1 Instrumentation, Electrical Fundamentals & SCADA 7.2 Preventive Maintenance, Pumps, Motors & Mechanical Equipment 7.3 Bacteriology, Sample Siting Plans & RTCR Compliance Sampling

8 Chapter 8: Biological Wastewater Treatment & Secondary Processes

8.1 Wastewater Characterization, Preliminary Screening & Primary Clarification 8.2 Wastewater Lagoons, Stabilization Ponds & Operational Control 8.3 Constructed Wetlands & Natural Treatment Systems 8.4 Septic Tanks, Media Filters, Aerobic Treatment Units & Grease Interceptors 8.5 Attached Growth Systems: Trickling Filters, RBCs & Fixed-Film Processes 8.6 Activated Sludge Microbiology, Aeration Basins & Secondary Clarifiers 8.7 Operational Process Control: F/M Ratio, MCRT / Sludge Age & SVI

9 Chapter 9: Nutrient Removal, Solids Handling & Effluent Management

9.1 Biological Nutrient Removal (BNR) in NC Nutrient-Sensitive Waters (NSW) 9.2 Sludge Stabilization, Aerobic/Anaerobic Digestion & Biosolids Management 9.3 Digester Gas Systems, Heating, Mixing & Explosion Safety 9.4 Composting, Thermal Drying & Alternative Solids Disposal 9.5 Odor Sources, Measurement & Control Technologies 9.6 Tertiary Filtration, Reclaimed Water & Reuse Under 15A NCAC 02U 9.7 Effluent Disinfection, Dechlorination & NPDES Permit Compliance

10 Chapter 10: Wastewater Collection Systems, Lift Stations & Field Operations

10.1 Wastewater Collection System Design, Lift Stations & Inflow and Infiltration (I/I) 10.2 Manholes, Service Taps, Laterals & Sewer Construction Practice 10.3 Sewer Cleaning, Root Control & Preventive Maintenance Programs 10.4 Collection System Inspection & Acceptance Testing 10.5 Job-Site Pre-Planning, Traffic Control & Field Work Safety

11 Chapter 11: Industrial Pretreatment & Physical/Chemical Treatment

11.1 Industrial Pretreatment Programs & Protecting the POTW 11.2 Physical/Chemical Treatment Processes for Industrial Wastewater 11.3 Groundwater Remediation Systems, Flow Equalization & Flow Measurement

12 Chapter 12: Laboratory, Safety, Utility Management & Applied Mathematics

12.1 Laboratory Analytical Methods, Sampling Procedures & QA/QC 12.2 Chemical Safety, Gaseous Chlorine Handling & Hazard Communication 12.3 Permit-Required Confined Space Entry & Excavation / Trenching Safety 12.4 Electrical Safety, Lockout/Tagout & Machine Guarding 12.5 Biological Hazards, PPE, Heat Stress & Personal Hygiene 12.6 Applied Water & Wastewater Mathematics & Process Calculations 12.7 Process Control Mathematics: Loading, Efficiency, Removal & Solids 12.8 Hydraulics, Pressure & Unit Conversion Mathematics 12.9 Utility Management: Personnel, Budgeting, Public Relations & Plant Security

2.1 Designating the ORC and Back-up ORC: Forms, Deadlines & Legal Duties

Key Takeaways Explain This Topic AI

Under 15A NCAC 08G .0201 a wastewater owner must designate one ORC holding a certificate of the same type and at least the same grade as the system, plus one or more Back-up ORCs holding the same type and no more than one grade lower.

Wastewater Operator Designation Forms are due 60 days before wastewater enters a new system, within 120 days after a classification change or a single vacancy, and within seven days when both the ORC and Back-up ORC positions are vacant.

Drinking water owners must notify the Board in writing within 10 days of a vacancy that causes noncompliance (18D .0206(a)) and within 10 days when an ORC takes on or gives up a system (18D .0701(e)); a surface water plant vacancy must be reported within 24 hours and filled within 90 days.

The 50-mile figure in drinking water is not a residency rule: 18D .0701(b)(8) makes written Board permission necessary before one person is ORC of any facility more than a 50-mile radius from where the operator resides.

A wastewater Back-up ORC may act as surrogate for no more than 40 percent of the required annual visitations, or up to 120 consecutive days when the ORC position is vacant or the ORC is absent for personal or family illness.

Last updated: September 2026

2.1 Designating the ORC and Back-up ORC: Forms, Deadlines & Legal Duties

Important

Owning a plant does not authorize operating it. G.S. 90A-29(a) obligates the owner of a water treatment facility to ensure the ORC is certified, and G.S. 90A-44 forbids an owner of a water pollution control system from letting it be operated by anyone without a valid certificate of the appropriate grade and type. The designation is a formal, signed filing — not an internal job assignment.

Wastewater designation: who and how (15A NCAC 08G .0201)

For each classification a system carries, the owner shall:

Designate one ORC who possesses a valid certificate of the type and at least the grade of the system.

Designate one or more Back-up ORCs who possess a valid certificate of the same type and no more than one grade less than the system's grade. The only exception: no Back-up ORC is required for systems whose minimum visitation requirement is twice per year .

Submit a signed Operator Designation Form to the Commission (or to the local health department for subsurface systems), countersigned by the designated operators, showing the owner's name, contact information, and signature; the system name, location, permit number, type, and classification; and each operator's name, contact information, certificate type and grade, and signature.

The wastewater filing deadlines — memorize these

  • Trigger Deadline
  • Before wastewater or residuals are introduced into a new system 60 days prior

Notification of a classification change requiring a new ORC/Back-up ORC of proper type and grade within 120 days

A vacancy in the ORC or Back-up ORC position within 120 days

Vacancies in both the ORC and Back-up ORC positions within 7 days , replacing or designating one of the responsibilities

Separately, an operator vacating an ORC or Back-up ORC position must send written notice within 14 days to the Commission and the appropriate regional office (or local health department for subsurface systems) under 08G .0204(9) and .0205(3).

Drinking water designation (15A NCAC 18D .0206 and .0701)

Treatment facilities. Every public water system must have a certified ORC for each water treatment facility that alters the physical, chemical, or microbiological characteristics of the water, has approved plans for such alterations, or has equipment installed for them. The owner must notify the Board in writing within 10 days of a vacancy that results in noncompliance.

Surface water staffing. An operator holding at least a Grade C-Surface certificate must be on duty on the premises whenever a surface water treatment facility is treating water . On a vacancy causing noncompliance, the owner notifies the Board within 24 hours or at the start of the next business day and must fill the position with a certified Grade C-Surface operator, or one holding a temporary Grade C-Surface certificate, within 90 days .

Distribution and cross-connection control. Community and non-transient non-community systems need a distribution ORC whose grade equals or exceeds the distribution classification; systems with five or more testable backflow assemblies need a Cross-Connection Control ORC.

Changes in responsibility. Under 18D .0701(e), an ORC who takes responsibility for an additional system or relinquishes a system must notify the Board in writing within 10 days . Under .0701(d), the ORC reports the names and PWSID numbers of all systems they are ORC for with the annual certification renewal .

How many systems may one drinking water ORC hold? (18D .0701(b))

Without written permission from the Board , no person shall be in responsible charge of more than any one of the following:

  • one surface water treatment facility;
  • five community public water systems with well water facilities;
  • ten non-community public water systems with well water facilities;
  • one distribution system serving over 3,300 service connections;
  • five distribution systems serving over 500 and fewer than 3,300 connections;
  • ten total distribution systems;
  • ten total cross-connection control systems; or

any facility located more than a 50-mile radius from where the operator resides .

Nor may anyone be ORC of a combination of these facility types without written Board permission. A request must document that the facilities will be managed in compliance with 15A NCAC 18C.

Warning

Trap — the ‘50-mile rule.’ It is not a prohibition on living far away and it is not a response-time standard. It is one of the eight limits in 18D .0701(b) that require written Board permission before an operator serves as ORC of a facility outside a 50-mile radius of their residence.

Duties the ORC personally carries

Wastewater (08G .0204). The ORC must hold the proper certificate; visit the system at the required frequency; operate and maintain the system and attempt to ensure permit compliance; certify by signature the validity of all monitoring and reporting information and give the owner a copy; document operation, maintenance, and all visitation in a log maintained at the system ; notify the owner within 24 hours and in writing within five days of first knowledge of any overflow, bypass, or permit violation; notify the owner in writing of needed repairs and modifications; be available on an on-call basis for in-person interactions with the owner, regulators, and emergencies, and to provide facility access; and give written notice within 14 days of vacating the position.

Drinking water (18D .0701). The ORC manages daily operation and maintenance; must establish standard operating procedures for each facility so that decisions affecting water quality or quantity are carried out and uncertified staff refer public-health decisions to a certified operator; must be available for consultation on the premises in an emergency, equipment malfunction, or breakdown; and may designate a temporary ORC holding a certification equal to or exceeding the system's classification when it is impossible to be on the premises — notifying the Board of any temporary designation lasting longer than 14 days .

The Back-up ORC's surrogate authority (08G .0205)

A Back-up ORC holding a valid certificate of the appropriate type and grade may act as surrogate for the ORC:

for a period not to exceed 40 percent of the system visitations required per calendar year under .0204(2); or

for not more than 120 consecutive days when the ORC is absent due to a vacancy in the ORC position or personal or familial illness.

While acting as surrogate, the Back-up ORC must fulfill all of the ORC duties in .0204.

Who may not be designated

A drinking water Apprentice "shall not act as a certified operator or an Operator in Responsible Charge for a facility" (18D .0201(13)).

A wastewater Operator in Training "must not be designated as the Operator in Responsible Charge (ORC) or Back-up Operator In Responsible Charge" (08G .0408(c)).

An operator whose certificate has expired or become invalid holds no valid certificate and therefore cannot serve in either role.

Penalties for operating without a certified ORC

Program Authority Exposure

Drinking water G.S. 90A-30 Administrative civil penalty of not more than $100 per day , each day a separate violation; the statute states this is the only civil or criminal penalty for failing to have a certified ORC

Wastewater G.S. 143-215.6A Civil penalties up to $25,000 per day for violations of Article 21, including permit violations; criminal penalties under G.S. 143-215.6B ; injunctive relief under G.S. 143-215.6C

Either G.S. 90A-26 / 90A-41 Reprimand, suspension, or revocation of the individual operator's certificate

Contract operations firms do not escape these duties: G.S. 90A-45 requires a commercial wastewater operating firm to designate a certified employee as ORC, and G.S. 90A-31 does the same for commercial water treatment operation firms.