Study guide
7.3 Bacteriology, Sample Siting Plans & RTCR Compliance Sampling
North Carolina Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: North Carolina Regulatory Framework, Certification & Classification
1.1 Dual Regulatory Structure: WTFOCB, WPCSOCC & NC DEQ 1.2 Drinking Water Certification Grades, Eligibility & the Apprentice Pathway 1.3 Examinations, Fees, Renewal, Continuing Education & Discipline 1.4 Classifying Drinking Water Facilities: Rating Values, Classes & Required Operators 1.5 Classifying Water Pollution Control Systems Under 15A NCAC 08G .0300 1.6 Wastewater Certification Types, Experience Ladders, OIT & Reciprocity
2 Chapter 2: Operator in Responsible Charge, Oversight & Regulatory Reporting
2.1 Designating the ORC and Back-up ORC: Forms, Deadlines & Legal Duties 2.2 Mandatory Visitation Frequencies & Facility Oversight 2.3 Operational Logs, Records Retention & Compliance Reporting 2.4 Sanitary Sewer Overflows: Reporting, Press Releases & Public Notice 2.5 The Federal Drinking Water Rule Framework Operators Are Tested On
3 Chapter 3: Drinking Water Treatment: Source Water Through Filtration
3.1 Source Water Quality, Raw Water Intake & Rapid Mixing 3.2 Coagulation Chemistry, Flocculation & Sedimentation Basins 3.3 Granular Media Filtration, Head Loss & Backwash Protocols 3.4 Taste and Odor Control, Powdered Activated Carbon & Algae Management
4 Chapter 4: Disinfection, Chemical Conditioning & Advanced Water Treatment
4.1 Chlorination Chemistry, Breakpoint Chlorination & CT Disinfection Inactivation 4.2 Disinfection Byproducts (TTHM & HAA5), Stage 1/2 DBPR & Enhanced Coagulation 4.3 Corrosion Control, Lead & Copper Rule Revisions, Fluoridation & Groundwater Treatment 4.4 Iron and Manganese Control: Oxidation, Greensand & Sequestration 4.5 Softening, Ion Exchange & Membrane Treatment 4.6 Water Plant Residuals, Backwash Recovery & Waste Disposal
5 Chapter 5: Groundwater Sources, Wells & Small Water Systems
5.1 Well Hydrology, Aquifers & North Carolina Well Construction Standards 5.2 Well Pumps, Wellhead Equipment & Source Protection 5.3 Small Water System Operations, Administration & Plant Recordkeeping
6 Chapter 6: Water Distribution Systems, Storage & Cross-Connection Control
6.1 Water Distribution Hydraulics, Storage Facilities & Water Quality Maintenance 6.2 Water Use, Demand Patterns & Distribution System Design 6.3 Pipe Materials, Main Installation, Service Connections & Meters 6.4 Fire Hydrants, Valve Operation & Distribution Operational Practices 6.5 Pump Hydraulics, Valve Operation & Cross-Connection Control / Backflow Prevention 6.6 System Mapping, Records & Information Management 6.7 Utility Security, Emergency Response & Boil Water Advisories
7 Chapter 7: Instrumentation, Electrical Fundamentals, Maintenance & Microbiological Monitoring
7.1 Instrumentation, Electrical Fundamentals & SCADA 7.2 Preventive Maintenance, Pumps, Motors & Mechanical Equipment 7.3 Bacteriology, Sample Siting Plans & RTCR Compliance Sampling
8 Chapter 8: Biological Wastewater Treatment & Secondary Processes
8.1 Wastewater Characterization, Preliminary Screening & Primary Clarification 8.2 Wastewater Lagoons, Stabilization Ponds & Operational Control 8.3 Constructed Wetlands & Natural Treatment Systems 8.4 Septic Tanks, Media Filters, Aerobic Treatment Units & Grease Interceptors 8.5 Attached Growth Systems: Trickling Filters, RBCs & Fixed-Film Processes 8.6 Activated Sludge Microbiology, Aeration Basins & Secondary Clarifiers 8.7 Operational Process Control: F/M Ratio, MCRT / Sludge Age & SVI
9 Chapter 9: Nutrient Removal, Solids Handling & Effluent Management
9.1 Biological Nutrient Removal (BNR) in NC Nutrient-Sensitive Waters (NSW) 9.2 Sludge Stabilization, Aerobic/Anaerobic Digestion & Biosolids Management 9.3 Digester Gas Systems, Heating, Mixing & Explosion Safety 9.4 Composting, Thermal Drying & Alternative Solids Disposal 9.5 Odor Sources, Measurement & Control Technologies 9.6 Tertiary Filtration, Reclaimed Water & Reuse Under 15A NCAC 02U 9.7 Effluent Disinfection, Dechlorination & NPDES Permit Compliance
10 Chapter 10: Wastewater Collection Systems, Lift Stations & Field Operations
10.1 Wastewater Collection System Design, Lift Stations & Inflow and Infiltration (I/I) 10.2 Manholes, Service Taps, Laterals & Sewer Construction Practice 10.3 Sewer Cleaning, Root Control & Preventive Maintenance Programs 10.4 Collection System Inspection & Acceptance Testing 10.5 Job-Site Pre-Planning, Traffic Control & Field Work Safety
11 Chapter 11: Industrial Pretreatment & Physical/Chemical Treatment
11.1 Industrial Pretreatment Programs & Protecting the POTW 11.2 Physical/Chemical Treatment Processes for Industrial Wastewater 11.3 Groundwater Remediation Systems, Flow Equalization & Flow Measurement
12 Chapter 12: Laboratory, Safety, Utility Management & Applied Mathematics
12.1 Laboratory Analytical Methods, Sampling Procedures & QA/QC 12.2 Chemical Safety, Gaseous Chlorine Handling & Hazard Communication 12.3 Permit-Required Confined Space Entry & Excavation / Trenching Safety 12.4 Electrical Safety, Lockout/Tagout & Machine Guarding 12.5 Biological Hazards, PPE, Heat Stress & Personal Hygiene 12.6 Applied Water & Wastewater Mathematics & Process Calculations 12.7 Process Control Mathematics: Loading, Efficiency, Removal & Solids 12.8 Hydraulics, Pressure & Unit Conversion Mathematics 12.9 Utility Management: Personnel, Budgeting, Public Relations & Plant Security
7.3 Bacteriology, Sample Siting Plans & RTCR Compliance Sampling
Key Takeaways Explain This Topic AI
Coliforms are indicator organisms, not pathogens: total coliform indicates a possible pathway into the system, while E. coli indicates fecal contamination and triggers an acute violation.
Every public water system must sample according to a written sample siting plan, at the frequency set by population, and samples must be representative of water throughout the distribution system.
A total coliform positive routine sample triggers repeat samples — normally three, at the original site and at points upstream and downstream within five service connections — collected within 24 hours.
Exceeding the RTCR assessment triggers requires a Level 1 assessment by the system; an E. coli MCL violation or repeated Level 1 triggers require a Level 2 assessment by an approved party, and sanitary defects found must be corrected.
Sample bottles must be sterile, contain sodium thiosulfate when the water is chlorinated, be filled without rinsing to the fill line, be kept below 10 degrees Celsius, and reach the laboratory within the 30-hour drinking water holding time.
Last updated: September 2026
7.3 Bacteriology, Sample Siting Plans & RTCR Compliance Sampling
The Board's needs-to-know tables score Bacteriology on every surface and well examination, drawing from the Rules Governing Public Water Systems. This section covers what the organisms mean, how the samples are taken, and what happens when one comes back positive.
1. Indicator organisms
Group What it means
Total coliform A broad group of gram-negative, non-spore-forming, lactose-fermenting rods found in soil, vegetation, and intestines. Their presence signals a potential pathway — a breach, a low-pressure event, a defective seal, or biofilm growth.
Fecal coliform / E. coli A subset specific to the intestines of warm-blooded animals. Presence signals fecal contamination and possible pathogens.
Heterotrophic plate count (HPC) Non-specific count of bacteria able to grow on a nutrient medium; used as a general measure of distribution biological activity and residual effectiveness.
Coliforms are used because they are numerous when contamination exists, survive longer in water than most pathogens, and are inexpensive to detect — the pathogens themselves are too sporadic and too costly to monitor directly.
2. Sample siting plan and frequency
Every system must maintain a written sample siting plan listing the routine and repeat sampling locations and the schedule. Requirements the plan must satisfy:
Sites must be representative of water throughout the distribution system , not clustered near the plant.
The plan identifies repeat sample locations upstream and downstream of each routine site.
Routine monitoring frequency is set by population served , from once per month for the smallest systems up to many samples per month for large systems.
Sites must be protected from cross-connection and from sampling errors — no leaking faucets, no swivel or aerator taps, no hose bibs adjacent to hazards.
Distribution residual disinfectant sampling runs alongside coliform monitoring: under 18C .1302(a)(2) Table A, Class D systems collect 1 residual sample weekly, Class C systems 3, and Class A and B systems 5, at locations representing maximum residence time or high water age, with same-day samples taken from different locations.
3. Correct sampling technique
Select an approved sampling tap on a service line — not a hose bib, not a swivel faucet, not a tap with an aerator or screen.
Remove the aerator if present; disinfect the tap if the site protocol requires it.
Flush long enough to draw water from the main, typically 3 to 5 minutes, then reduce to a smooth pencil-sized stream.
Measure the disinfectant residual and record it with the sample.
Open the sterile bottle without touching the inside of the cap or bottle neck; do not rinse the bottle — it contains sodium thiosulfate to neutralize the chlorine residual so bacteria are not killed in transit.
Fill to the 100 mL fill line , leaving headspace for mixing, and cap immediately.
Label completely, complete the chain of custody, and place on ice at below 10 °C without freezing.
Deliver so the laboratory can begin analysis within the drinking water holding time — 30 hours from collection (wastewater fecal coliform samples have a far shorter 8-hour limit).
Analytical methods. Membrane filtration passes 100 mL through a 0.45 micrometre filter incubated on a selective medium; m-Endo produces coliform colonies with a green metallic sheen. Defined-substrate tests such as Colilert use ONPG, hydrolyzed by beta-galactosidase to give a yellow color for total coliforms, and MUG, hydrolyzed by beta-glucuronidase to fluoresce blue under 365 nm UV for E. coli . Incubation is 24 hours at 35 °C ± 0.5 °C.
- 4. When a sample is total coliform positive Routine sample TOTAL COLIFORM POSITIVE
- |
- +--> Analyze that sample for E. coli
- |
+--> Collect REPEAT samples within 24 hours:
- at the original site,
- within five service connections UPSTREAM,
- within five service connections DOWNSTREAM
- |
- +--> Any repeat positive -> another round of repeats
- |
- +--> Evaluate against the ASSESSMENT TRIGGERS
Assessment triggers. A Level 1 assessment is required when a system collecting 40 or more samples per month has more than 5.0 percent of samples total coliform positive, when a system collecting fewer than 40 samples has two or more total coliform positive samples in a month, or when a system fails to take every required repeat sample. A Level 2 assessment , performed by an approved party, is required after an E. coli MCL violation or after a second Level 1 trigger within a rolling 12-month period. Sanitary defects identified in either assessment must be corrected , and the assessment form must be submitted to the State.
The E. coli MCL is violated when a routine sample is total coliform positive and a repeat is E. coli positive, when a routine is E. coli positive and a repeat is total coliform positive, when a system fails to take all required repeats after an E. coli positive routine, or when a system fails to test for E. coli after a total coliform positive repeat. That violation is acute and requires Tier 1 public notice within 24 hours.
5. Investigating a positive — the operator's checklist
Confirm the sampling technique and site: aerator, hose, unflushed line, non-sterile handling, or an expired bottle explain a great many single positives.
Check the residual at the site and upstream: a zero or near-zero residual points to water age, a dead end, or a loss of feed.
Look for pressure loss events — main breaks, hydrant use, pump failures, fires — in the preceding days.
Inspect storage: hatch seals, vents, overflow screens, and floating covers are the classic intrusion pathways.
Review cross-connection potential at and near the site.
Flush, re-disinfect where appropriate, and re-sample; document every step in the log.
Warning
Do not ‘wash out’ a positive. Flushing a line and resampling to obtain a clean result without collecting the required repeat samples is both a monitoring violation and a missed chance to find the real defect. Take the repeats the rule requires first.