Study guide

1.2 Ohm's Law and Electrical Power

ASTM NCATT Aircraft Electronics Technician AET

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: DC Electricity and Circuit Fundamentals

1.1 DC Basic Terms, Atomic Structure, and Charge 1.2 Ohm's Law and Electrical Power 1.3 Series and Parallel DC Circuits 1.4 Voltage Drop, Circuit Protection, and Aircraft Batteries 1.5 Basic Circuit Troubleshooting

2 Chapter 2: AC Electricity

2.1 AC Fundamentals and Sine Wave Metrics 2.2 Inductive Reactance and Inductance 2.3 Capacitive Reactance and Capacitance 2.4 Impedance, Resonance, Power Factor, and Three-Phase Systems

3 Chapter 3: Passive Components and Transformers

3.1 Resistors and Resistor Color Codes 3.2 Inductors, Capacitors, and RC/RL Time Constants 3.3 Transformers and Magnetic Circuits

4 Chapter 4: Semiconductor Devices and Active Circuits

4.1 Diodes, Rectifiers, and Zener Diodes 4.2 Transistors, Relays, and Switches 4.3 Filters, Oscillators, and Multivibrators 4.4 Limiter Circuits

5 Chapter 5: Digital Techniques and Logic Systems

5.1 Numbering Systems and Conversions 5.2 Logic Gates and Logic Families 5.3 Sequential Logic, Flip-Flops, Counters, and Displays

6 Chapter 6: Maintenance, Safety, and Documentation

6.1 Electrical Safety, PPE, First Aid, and Noise Exposure 6.2 ESD Control, FOD Prevention, and Hazmat 6.3 Use of Common Tools 6.4 Test Equipment Operation 6.5 Aviation Regulations, Publications, and Documentation

7 Chapter 7: Aircraft Fundamentals and Wiring Systems

7.1 Aircraft Wiring Harnesses and Conductors 7.2 Wiring Installation Practices, Safety Wire, and Corrosion 7.3 Wire Maintenance and Continuity Testing 7.4 Aircraft Structures, Aerodynamics, Flight Controls, and Ground Handling

1.2 Ohm's Law and Electrical Power

Key Takeaways Explain This Topic AI

Ohm's Law expresses the direct relationship between voltage (E), current (I), and resistance (R): I = E/R, E = I * R, and R = E/I.

Electrical power (P), measured in Watts, represents the rate of electrical energy consumption or conversion: P = E * I = I^2 * R = E^2 / R.

Electrical energy (W), measured in Joules or Watt-hours (Wh), is the total work performed over time: W = P * t.

Avionics system power calculations must account for nominal 28 VDC aircraft bus voltage variations (typically 24.0 VDC battery to 28.5 VDC generator output) to ensure correct wire sizing and heat dissipation management.

Last updated: July 2026

1.2 Ohm's Law and Electrical Power

Quick Takeaway: Ohm's Law establishes the fundamental proportionalities of DC circuits: I = E / R I = E/R I = E / R , E = I ⋅ R E = I \cdot R E = I ⋅ R , and R = E / I R = E/I R = E / I . Electrical power ( P P P ), measured in Watts, defines the rate of energy dissipation: P = E ⋅ I = I 2 R = E 2 / R P = E \cdot I = I^2 R = E^2 / R P = E ⋅ I = I 2 R = E 2 / R . In aircraft 28 VDC systems, calculating total bus current and power dissipation ensures correct circuit breaker sizing, wire gauge selection, and thermal management for flight-critical electronics.

Ohm's Law Fundamentals and Mathematical Relationships

Formulated by German physicist Georg Simon Ohm in 1827, Ohm's Law is the foundational relationship governing direct current electrical circuits. Ohm discovered that the current ( I I I ) flowing through a conductor between two points is directly proportional to the potential difference or voltage ( E E E ) across the two points and inversely proportional to the resistance ( R R R ) between them.

Mathematically, Ohm's Law is expressed in three equivalent forms:

Solving for Current ( I I I ): I = E R [Amperes = Volts / Ohms] I = \frac{E}{R} \quad \text{[Amperes = Volts / Ohms]} I = R E ​ [Amperes = Volts / Ohms]

Interpretation: Increasing system voltage increases current flow proportionally, whereas increasing circuit resistance reduces current flow proportionally.

Solving for Voltage / Potential Drop ( E E E ): E = I ⋅ R [Volts = Amperes × Ohms] E = I \cdot R \quad \text{[Volts = Amperes} \times \text{Ohms]} E = I ⋅ R [Volts = Amperes × Ohms]

Interpretation: The voltage drop across any resistive component equals the current passing through it multiplied by its resistance.

Solving for Resistance ( R R R ): R = E I [Ohms = Volts / Amperes] R = \frac{E}{I} \quad \text{[Ohms = Volts / Amperes]} R = I E ​ [Ohms = Volts / Amperes]

Interpretation: The effective resistance of a circuit or load can be determined by measuring the applied voltage and resulting current draw. Ohm's Law Triangle:

  • / E \
  • /-------\
  • / I | R \
  • ----------
  • E = I * R | I = E / R | R = E / I

In aircraft applications, standard nominal DC bus voltages are 14.0 VDC (light general aviation aircraft powered by 12 V lead-acid batteries) and 28.0 VDC (turboprop, business jet, and transport category aircraft powered by 24 V lead-acid or NiCd batteries, with generator output set to 28.5 VDC).

Electrical Power and Energy Equations

While Ohm's Law defines static voltage, current, and resistance, Watt's Law defines the work performed by electricity per unit of time. Electrical Power ( P P P ) is measured in Watts (W) , where one Watt represents an energy transfer rate of one Joule per second ( 1 W = 1 J/s 1\text{ W} = 1\text{ J/s} 1 W = 1 J/s ).

Power Wheel Formulas

By combining Ohm's Law ( E = I R E = IR E = I R ) with the basic power equation ( P = E I P = EI P = E I ), we derive three primary formulas for electrical power:

Standard Power Equation: P = E ⋅ I P = E \cdot I P = E ⋅ I

Used when system voltage and load current are known.

Joule Heating / Resistance-Current Equation: P = I 2 ⋅ R P = I^2 \cdot R P = I 2 ⋅ R

Used when load current and conductor resistance are known. This equation illustrates why high current leads to severe heating in wiring harnesses ( I 2 R I^2 R I 2 R losses).

Voltage-Resistance Equation: P = E 2 R P = \frac{E^2}{R} P = R E 2 ​

Used when system voltage and component internal resistance are known.

Mechanical Power Conversion

In aircraft electrical motor applications (e.g., flap actuators, fuel boost pumps, landing gear hydraulic power packs), electrical power is converted into mechanical horsepower (HP): 1 Horsepower (HP) = 746 Watts 1\text{ Horsepower (HP)} = 746\text{ Watts} 1 Horsepower (HP) = 746 Watts

Electrical Energy ( W W W )

Electrical Energy ( W W W ) represents total work performed over a given time interval ( t t t ): W = P ⋅ t W = P \cdot t W = P ⋅ t

SI units measure energy in Joules (J) ( 1 J = 1 Watt ⋅ second 1\text{ J} = 1\text{ Watt} \cdot \text{second} 1 J = 1 Watt ⋅ second ). In aviation battery capacity and power management, energy is commonly expressed in Watt-hours (Wh) or Kilowatt-hours (kWh) : W Wh = P Watts × t hours W_{\text{Wh}} = P_{\text{Watts}} \times t_{\text{hours}} W Wh ​ = P Watts ​ × t hours ​

Summary Matrix of DC Formulas

The following table summarizes all twelve mathematical combinations for solving E E E , I I I , R R R , and P P P in DC circuits:

Unknown Quantity Formula 1 (Basic) Formula 2 (Ohm Substitution) Formula 3 (Power Substitution) Standard Unit

Voltage ( E E E ) E = I ⋅ R E = I \cdot R E = I ⋅ R E = P I E = \frac{P}{I} E = I P ​ E = P ⋅ R E = \sqrt{P \cdot R} E = P ⋅ R ​ Volts ( V V V )

Current ( I I I ) I = E R I = \frac{E}{R} I = R E ​ I = P E I = \frac{P}{E} I = E P ​ I = P R I = \sqrt{\frac{P}{R}} I = R P ​ ​ Amperes ( A A A )

Resistance ( R R R ) R = E I R = \frac{E}{I} R = I E ​ R = E 2 P R = \frac{E^2}{P} R = P E 2 ​ R = P I 2 R = \frac{P}{I^2} R = I 2 P ​ Ohms ( Ω \Omega Ω )

Power ( P P P ) P = E ⋅ I P = E \cdot I P = E ⋅ I P = I 2 ⋅ R P = I^2 \cdot R P = I 2 ⋅ R P = E 2 R P = \frac{E^2}{R} P = R E 2 ​ Watts ( W W W )

  • Worked Avionics Calculation: Step-by-Step 28 VDC Essential Bus Load Analysis
  • Problem Scenario

An avionics technician is auditing the electrical load on an aircraft's 28.0 VDC Essential Bus during emergency battery-only operation. The bus supplies three parallel loads:

Primary Flight Display (PFD): Consumes 112 Watts 112\text{ Watts} 112 Watts of power.

VHF Com/Nav Transceiver: Consumes 84 Watts 84\text{ Watts} 84 Watts during transmit.

Avionics Cooling Fan: Possesses an internal operating resistance of 14.0 Ω 14.0\ \Omega 14.0 Ω .

Calculate:

(a) Current drawn by each load.

(b) Total current drawn from the 28.0 VDC essential bus.

(c) Total power consumed by the essential bus loads.

(d) Total thermal energy dissipated over a 45-minute battery endurance flight (in Watt-hours and Joules). +28.0 VDC Essential Bus -----------------------------------------+

  • | | |
  • [PFD] [VHF Com] [Cooling Fan]
  • 112 W 84 W R = 14.0 Ohm
  • | | |
  • Airframe Ground Return -------+--------------+--------------+
  • Step-by-Step Solution

Step 1: Calculate individual load currents.

For the PFD ( P 1 = 112 W P_1 = 112\text{ W} P 1 ​ = 112 W , E = 28.0 V E = 28.0\text{ V} E = 28.0 V ): I PFD = P 1 E = 112 W 28.0 V = 4.0 A I_{\text{PFD}} = \frac{P_1}{E} = \frac{112\text{ W}}{28.0\text{ V}} = 4.0\text{ A} I PFD ​ = E P 1 ​ ​ = 28.0 V 112 W ​ = 4.0 A

For the VHF Transceiver ( P 2 = 84 W P_2 = 84\text{ W} P 2 ​ = 84 W , E = 28.0 V E = 28.0\text{ V} E = 28.0 V ): I VHF = P 2 E = 84 W 28.0 V = 3.0 A I_{\text{VHF}} = \frac{P_2}{E} = \frac{84\text{ W}}{28.0\text{ V}} = 3.0\text{ A} I VHF ​ = E P 2 ​ ​ = 28.0 V 84 W ​ = 3.0 A

For the Avionics Cooling Fan ( R 3 = 14.0 Ω R_3 = 14.0\ \Omega R 3 ​ = 14.0 Ω , E = 28.0 V E = 28.0\text{ V} E = 28.0 V ): I Fan = E R 3 = 28.0 V 14.0 Ω = 2.0 A I_{\text{Fan}} = \frac{E}{R_3} = \frac{28.0\text{ V}}{14.0\ \Omega} = 2.0\text{ A} I Fan ​ = R 3 ​ E ​ = 14.0 Ω 28.0 V ​ = 2.0 A

Step 2: Calculate total essential bus current ( I total I_{\text{total}} I total ​ ).

Since the loads are connected in parallel across the bus: I total = I PFD + I VHF + I Fan = 4.0 A + 3.0 A + 2.0 A = 9.0 A I_{\text{total}} = I_{\text{PFD}} + I_{\text{VHF}} + I_{\text{Fan}} = 4.0\text{ A} + 3.0\text{ A} + 2.0\text{ A} = 9.0\text{ A} I total ​ = I PFD ​ + I VHF ​ + I Fan ​ = 4.0 A + 3.0 A + 2.0 A = 9.0 A

Step 3: Calculate total power consumed ( P total P_{\text{total}} P total ​ ).

Using P = E ⋅ I total P = E \cdot I_{\text{total}} P = E ⋅ I total ​ : P total = 28.0 V × 9.0 A = 252.0 Watts P_{\text{total}} = 28.0\text{ V} \times 9.0\text{ A} = 252.0\text{ Watts} P total ​ = 28.0 V × 9.0 A = 252.0 Watts

Alternatively, summing individual powers ( P Fan = E ⋅ I Fan = 28 × 2 = 56 W P_{\text{Fan}} = E \cdot I_{\text{Fan}} = 28 \times 2 = 56\text{ W} P Fan ​ = E ⋅ I Fan ​ = 28 × 2 = 56 W ): P total = 112 W + 84 W + 56 W = 252.0 Watts P_{\text{total}} = 112\text{ W} + 84\text{ W} + 56\text{ W} = 252.0\text{ Watts} P total ​ = 112 W + 84 W + 56 W = 252.0 Watts

Step 4: Calculate total energy consumed ( W W W ) during 45 minutes ( 0.75 hours 0.75\text{ hours} 0.75 hours ).

Energy in Watt-hours: W Wh = P total × t = 252.0 W × 0.75 h = 189.0 Watt-hours (Wh) W_{\text{Wh}} = P_{\text{total}} \times t = 252.0\text{ W} \times 0.75\text{ h} = 189.0\text{ Watt-hours (Wh)} W Wh ​ = P total ​ × t = 252.0 W × 0.75 h = 189.0 Watt-hours (Wh)

Energy in Joules ( 1 Wh = 3 , 600 Joules 1\text{ Wh} = 3,600\text{ Joules} 1 Wh = 3 , 600 Joules ): W Joules = 189.0 Wh × 3 , 600 J/Wh = 680 , 400 Joules (680.4 kJ) W_{\text{Joules}} = 189.0\text{ Wh} \times 3,600\text{ J/Wh} = 680,400\text{ Joules (680.4 kJ)} W Joules ​ = 189.0 Wh × 3 , 600 J/Wh = 680 , 400 Joules (680.4 kJ)

Avionics Trap: The I 2 R I^2 R I 2 R Quadratic Heating Trap and 28V vs 14V Aircraft Architecture

A critical design mistake made by entry-level technicians is failing to appreciate the quadratic nature of I 2 R I^2 R I 2 R power loss in aircraft wire harnesses. If current through a wire doubles, the power dissipated as heat increases by a factor of 2 2 = 4 2^2 = 4 2 2 = 4 . If current triples, heating increases by 3 2 = 9 3^2 = 9 3 2 = 9 .

This mathematical reality explains why transport-category aircraft use 28 VDC (or higher AC voltages like 115 VAC) rather than 14 VDC . To deliver 2 , 800 Watts 2,800\text{ Watts} 2 , 800 Watts of power to a hydraulic pump motor:

At 14 VDC , current draw is I = 2800 / 14 = 200 Amperes I = 2800 / 14 = 200\text{ Amperes} I = 2800/14 = 200 Amperes .

At 28 VDC , current draw is I = 2800 / 28 = 100 Amperes I = 2800 / 28 = 100\text{ Amperes} I = 2800/28 = 100 Amperes .

Halving the current reduces heat dissipation in feeder cables by 75 % 75\% 75% ( 1 / 4 of original I 2 R loss 1/4\text{ of original } I^2 R\text{ loss} 1/4 of original I 2 R loss ), allowing aircraft designers to use significantly lighter gauge wire (e.g., AWG 2 instead of AWG 0000), saving hundreds of pounds of airframe weight while dramatically improving thermal safety margins.