Study guide
7.3 Horizontal Forces and Attachment Demand
NCCCO Rigger Level II Exam
Track your progress as you read
Finished sections get a check mark.
1 Certification and Exam Preparation
1.1 Current Exam, Eligibility and Scheduling 1.2 Practical Tasks and Examination-Specific Rules 1.3 Study Method, References and Recertification
2 Identify and Measure the Load
2.1 Load Identity, Dimensions and Units 2.2 Load Weight, Density and Complete Inventories 2.3 Composition, Structural Integrity and Special Handling
3 Center of Gravity and Support Geometry
3.1 Center of Gravity and Suspended Stability 3.2 Attachment Points and Complete Force Paths 3.3 Final Position, Landing Supports and Derigging Access
4 Route and Site Hazards
4.1 Travel Path, Clearance and Work-Zone Control 4.2 Power Lines, Clearance Options and Electrical Response 4.3 Weather, Temperature and Ground Conditions
5 Team Duties and Communications
5.1 Signalperson Duties and Reliable Signals 5.2 Equipment Operator Duties and Capacity Decisions 5.3 Lift Director, Qualified Rigger and Hazard Communication
6 Equipment Requirements and Lift Planning
6.1 Determine Equipment Requirements and Compatibility 6.2 Written Plans, Sequence and Change Control 6.3 Critical-Lift Criteria, Risk and Contingencies
7 Balanced Sling Forces
7.1 Two-Leg Tension and Angle Reference 7.2 Length-to-Height Geometry and Headroom 7.3 Horizontal Forces and Attachment Demand
8 Composite and Unequal Loads
8.1 Composite Center of Gravity by Moments 8.2 Off-Center Reactions and Compatible Sling Geometry 8.3 Three- and Four-Leg Assemblies and Load Sharing
9 Wire Rope, Chain and Metal Mesh Slings
9.1 Select and Use Wire-Rope Slings 9.2 Alloy-Chain Assemblies and Approved Adjustment 9.3 Metal-Mesh Slings: Selection, Contact and Removal
10 Synthetic Rope, Web and Roundslings
10.1 Synthetic-Rope Slings and Approved Splices 10.2 Synthetic-Web Slings and Material Compatibility 10.3 Roundslings, Core Protection and Performance Fibers
11 Hitch Application and Sling Protection
11.1 Vertical and Basket Hitch Capacity 11.2 Choker Hitches, Choke Angle and Bundles 11.3 Softeners, Bend Protection and Cut Protection
12 Shackles, Hooks and Collector Hardware
12.1 Shackle Types, Pin Seating and Side Loading 12.2 Hooks, Latches and Permitted Load Seating 12.3 Master Links, Rings and Swivels
13 Threaded Points and Adjustable Hardware
13.1 Eyebolts, Shoulder Seating and Angular Demand 13.2 Swivel Hoist Rings and Installation Torque 13.3 Turnbuckles and Chain Hardware in Adjustable Systems
14 Compression Hardware and Rigging Blocks
14.1 Wire-Rope Clips and Permitted Terminations 14.2 Wedge Sockets, Rope Alignment and Tail Security 14.3 Rigging Blocks, Resultants and Reeving
15 Manual, Lever and Powered Hoists
15.1 Manual Chain Falls and Vertical Hoisting 15.2 Lever Hoists, Pulling Direction and Controlled Adjustment 15.3 Air and Electric Hoists: Supply, Duty and Controls
16 Jacks, Rollers and Portable Supports
16.1 Jacks, Toe Ratings and Positive Support 16.2 Dollies, Skates, Rollers and Horizontal Control 16.3 A-Frames, Gantries and Trolley Compatibility
17 Structural Lifters and Clamps
17.1 Lifting Beams, Spreaders and Configuration Ratings 17.2 Plate Clamps, Material Limits and Grip Conditions 17.3 Beam Clamps as Attachments and Beam/Girder Lifters
18 Mechanical, Vacuum and Magnetic Devices
18.1 Mechanical and Vacuum Lifting Devices 18.2 Close-Proximity and Remotely Operated Lifting Magnets 18.3 Scrap and Material-Handling Grapples
19 Inspection, Removal and Records
19.1 Inspecting All Six Sling Families 19.2 Hook and Rigging-Hardware Inspection 19.3 Below-the-Hook Device Inspection and Testing
20 Lift Control, Rotation and Completion
20.1 Take-Up, Trial Lift and Load Control 20.2 Controlled Rotation, Upending and Multiple-Crane Lifts 20.3 Secure the Load, Remove Rigging and Stow Equipment
21 Technical Standards and Crane Capacity
21.1 Apply the Correct Standard and Regulatory Scope 21.2 Crane Charts, Suspended Weight and Capacity Deductions 21.3 Personnel Hoisting Under OSHA 1926.1431
7.3 Horizontal Forces and Attachment Demand
Key Takeaways Explain This Topic AI
Opposing horizontal forces can balance globally while compressing the payload.
At 45 degrees, inward force equals the vertical reaction in this model.
A larger sling does not improve the payload structure’s strength.
Last updated: October 2026
Inclined slings also pull inward
An inclined sling provides an upward component and a horizontal component. The upward component supports weight. The horizontal component pulls the attachment toward the hook’s vertical projection. In a simple balanced bridle, the opposing horizontal forces balance globally but still act locally on the payload, its lugs and the structure between them.
Let R be the vertical reaction at a pick, T its sling tension and θ the angle from horizontal. The inward force F is: F = T cos θ = R tan θ F=T\cos\theta=\frac{R}{\tan\theta} F = T cos θ = tan θ R
The load can therefore be in overall equilibrium while carrying substantial compression or bending. “The horizontal forces cancel” does not mean the structure feels no force. It means their vector sum is zero for the complete idealized body.
Compare the same load at different angles
For a balanced 16,000-lb load, each vertical reaction is 8,000 lb. At 60 degrees from horizontal, tension is approximately 9,238 lb and the inward force at each pick is approximately 4,619 lb. At 45 degrees, tension is approximately 11,314 lb and inward force is 8,000 lb. At 30 degrees, tension is 16,000 lb and inward force is approximately 13,856 lb.
- Horizontal angle Leg tension Inward force at each pick
- 60° 9,238 lb 4,619 lb
- 45° 11,314 lb 8,000 lb
- 30° 16,000 lb 13,856 lb
These rounded values use trigonometric calculations before rounding the results. A supplied factor of 1.155 would instead give 9,240 lb for the 60-degree tension. Small differences from an explicitly rounded factor are not contradictions; mixing rounding methods without explanation is the problem.
Evaluate the payload structure
A thin tank shell may tolerate its own vertical weight but not inward compression from a direct bridle. A long fabricated member may be vulnerable to bending or buckling when force enters outside its intended plane. A lug and weld may be designed for a particular direction rather than any resultant of the same magnitude.
The rigger must identify the actual load path and verify the approved handling conditions. Comparing leg tension only with sling WLL leaves the attachment and intervening structure unevaluated. A larger sling can transmit an even larger force into the same weak panel; it does not strengthen the panel.
Spreader bars can carry inward forces in their member when arranged with approved top bridles and vertical lower drops. Lifting beams can provide vertical lower connections while taking bending through their structure. The actual device must be rated for its configuration, span and forces. Neither generic name approves a homemade beam or an unverified compression member.
Distinguish force direction from magnitude
A connection rated for a vertical pull may not accept a side load of the same numerical value. A shouldered eyebolt has angle-dependent instructions; a shackle may have permitted side-load reductions; a hoist ring needs room to align. The capacity review must use the relevant direction and manufacturer information.
The term “load on the lug” may mean a vertical reaction, an inclined resultant or another specified force. Read the question carefully and label the requested quantity. If the question asks for inward compression at the pick, answering leg tension confuses components. If it asks for sling tension, answering half the payload weight is equally incomplete.
Local-force example
A load is balanced and each attachment supplies 10,000 lb vertically. The slings are at 45 degrees from horizontal. Each sling carries approximately 14,142 lb, and each attachment also receives 10,000 lb inward. The two inward forces oppose each other, but the payload structure between those attachments must carry their effect. It is not correct to say the attachments experience only the 10,000-lb vertical share.
Use force checks to choose a remedy
If inward demand is unsuitable, possible remedies include an approved spreader or beam, a different attachment arrangement, more suitable geometry or a redesigned handling method. The responsible qualified person must verify the resulting system. Moving the hook higher can reduce inward force, but available headroom and approved sling lengths may limit that option.
Do not improvise with an ordinary pipe between the slings. Its compression, buckling, connection and retention capacity have not been established. The approved lifting device must also retain the lower load safely and remain stable through the movement.
A useful calculation check is to resolve the calculated tension back into vertical and horizontal components. The vertical components must sum to the supported weight under the assumed model, and the horizontal components must satisfy equilibrium. If they do not, either the arithmetic or the proposed geometry is inconsistent.
Derive force without a tangent function
For a right triangle with horizontal distance D and rise H, inward force is the vertical reaction multiplied by D/H. A 6,000-lb vertical reaction with D = 4 ft and H = 8 ft produces 3,000 lb inward. This calculation uses only division and multiplication and is useful with the examination's four-function calculator.
The corresponding leg length is approximately 8.944 ft, making tension about 6,708 lb. The components describe one force: an 8-ft rise and 4-ft run establish both the magnitude and direction. Moving the pick or hook requires updating both components. A separate convenient inward-force value cannot be assigned without checking the resulting geometry.
Source: CCO reference materials .