Study guide
15.3 Air and Electric Hoists: Supply, Duty and Controls
NCCCO Rigger Level II Exam
Track your progress as you read
Finished sections get a check mark.
1 Certification and Exam Preparation
1.1 Current Exam, Eligibility and Scheduling 1.2 Practical Tasks and Examination-Specific Rules 1.3 Study Method, References and Recertification
2 Identify and Measure the Load
2.1 Load Identity, Dimensions and Units 2.2 Load Weight, Density and Complete Inventories 2.3 Composition, Structural Integrity and Special Handling
3 Center of Gravity and Support Geometry
3.1 Center of Gravity and Suspended Stability 3.2 Attachment Points and Complete Force Paths 3.3 Final Position, Landing Supports and Derigging Access
4 Route and Site Hazards
4.1 Travel Path, Clearance and Work-Zone Control 4.2 Power Lines, Clearance Options and Electrical Response 4.3 Weather, Temperature and Ground Conditions
5 Team Duties and Communications
5.1 Signalperson Duties and Reliable Signals 5.2 Equipment Operator Duties and Capacity Decisions 5.3 Lift Director, Qualified Rigger and Hazard Communication
6 Equipment Requirements and Lift Planning
6.1 Determine Equipment Requirements and Compatibility 6.2 Written Plans, Sequence and Change Control 6.3 Critical-Lift Criteria, Risk and Contingencies
7 Balanced Sling Forces
7.1 Two-Leg Tension and Angle Reference 7.2 Length-to-Height Geometry and Headroom 7.3 Horizontal Forces and Attachment Demand
8 Composite and Unequal Loads
8.1 Composite Center of Gravity by Moments 8.2 Off-Center Reactions and Compatible Sling Geometry 8.3 Three- and Four-Leg Assemblies and Load Sharing
9 Wire Rope, Chain and Metal Mesh Slings
9.1 Select and Use Wire-Rope Slings 9.2 Alloy-Chain Assemblies and Approved Adjustment 9.3 Metal-Mesh Slings: Selection, Contact and Removal
10 Synthetic Rope, Web and Roundslings
10.1 Synthetic-Rope Slings and Approved Splices 10.2 Synthetic-Web Slings and Material Compatibility 10.3 Roundslings, Core Protection and Performance Fibers
11 Hitch Application and Sling Protection
11.1 Vertical and Basket Hitch Capacity 11.2 Choker Hitches, Choke Angle and Bundles 11.3 Softeners, Bend Protection and Cut Protection
12 Shackles, Hooks and Collector Hardware
12.1 Shackle Types, Pin Seating and Side Loading 12.2 Hooks, Latches and Permitted Load Seating 12.3 Master Links, Rings and Swivels
13 Threaded Points and Adjustable Hardware
13.1 Eyebolts, Shoulder Seating and Angular Demand 13.2 Swivel Hoist Rings and Installation Torque 13.3 Turnbuckles and Chain Hardware in Adjustable Systems
14 Compression Hardware and Rigging Blocks
14.1 Wire-Rope Clips and Permitted Terminations 14.2 Wedge Sockets, Rope Alignment and Tail Security 14.3 Rigging Blocks, Resultants and Reeving
15 Manual, Lever and Powered Hoists
15.1 Manual Chain Falls and Vertical Hoisting 15.2 Lever Hoists, Pulling Direction and Controlled Adjustment 15.3 Air and Electric Hoists: Supply, Duty and Controls
16 Jacks, Rollers and Portable Supports
16.1 Jacks, Toe Ratings and Positive Support 16.2 Dollies, Skates, Rollers and Horizontal Control 16.3 A-Frames, Gantries and Trolley Compatibility
17 Structural Lifters and Clamps
17.1 Lifting Beams, Spreaders and Configuration Ratings 17.2 Plate Clamps, Material Limits and Grip Conditions 17.3 Beam Clamps as Attachments and Beam/Girder Lifters
18 Mechanical, Vacuum and Magnetic Devices
18.1 Mechanical and Vacuum Lifting Devices 18.2 Close-Proximity and Remotely Operated Lifting Magnets 18.3 Scrap and Material-Handling Grapples
19 Inspection, Removal and Records
19.1 Inspecting All Six Sling Families 19.2 Hook and Rigging-Hardware Inspection 19.3 Below-the-Hook Device Inspection and Testing
20 Lift Control, Rotation and Completion
20.1 Take-Up, Trial Lift and Load Control 20.2 Controlled Rotation, Upending and Multiple-Crane Lifts 20.3 Secure the Load, Remove Rigging and Stow Equipment
21 Technical Standards and Crane Capacity
21.1 Apply the Correct Standard and Regulatory Scope 21.2 Crane Charts, Suspended Weight and Capacity Deductions 21.3 Personnel Hoisting Under OSHA 1926.1431
15.3 Air and Electric Hoists: Supply, Duty and Controls
Key Takeaways Explain This Topic AI
Air pressure and flow must be adequate at the hoist.
Electric hoist duty can limit repetitive operation.
Follow product-specific loss-of-supply and isolation procedures.
Last updated: October 2026
Powered operation adds supply requirements
Air hoists use compressed air to drive their mechanism. Electric hoists use a specified electrical supply and controls. Both require adequate rated capacity, suitable suspension, correct chain or rope, travel range and manufacturer-supported operation. The power source does not change the need to calculate load and verify every connection.
Choose equipment for the required speed and precision, duty, environment and control method. A fast production hoist may be unsuitable for a delicate placement if its permitted controls cannot provide the needed movement. A light portable hoist may have a duty limitation that matters in repetitive lifting. Catalog capacity alone is not a complete selection.
Air-hoist selection
An air hoist needs the specified pressure and flow at the hoist . A compressor’s nominal rating at its outlet does not prove the pressure remains adequate after long hoses, restrictive fittings or simultaneous tool use. Inadequate supply can affect speed, control and operation.
Check hose size, connections, filtration, lubrication and water-control requirements from the manual. Do not assume every air hoist uses the same pressure or that increasing supply above the specified range is permitted. Higher pressure is not an authorized capacity increase.
Air-powered equipment is not automatically approved for every explosive or hazardous environment. The hoist’s materials, controls and any spark-resistant or hazardous-location provisions must fit the actual classification. A motor without an electrical cord does not remove mechanical sparks, static or other ignition considerations.
Verify pendant or control operation, emergency stop where provided, brake or load-holding function and the approved response to loss of air. Do not assume every system holds identically after supply failure. The manufacturer’s procedure and planned contingency establish what operators must do.
Electric-hoist selection
An electric hoist needs the correct voltage, phase, frequency and other specified supply conditions. Improvised extensions, damaged cables or unsuitable controls can create electrical and operational hazards. Installation must meet the equipment instructions and applicable electrical requirements through qualified personnel.
The duty rating describes permitted operation over time, not just one load’s weight. Frequent starts, extended running or repetitive near-rated lifts can overheat equipment beyond its intended duty. Select the product for the actual cycle rather than assuming all same-capacity hoists can work continuously.
Check controls, travel limits, overload devices where provided, brakes and emergency-stop functions under the manual’s inspection procedure. Limit switches are not ordinary operating targets to strike repeatedly. A failed safety or control device requires the applicable out-of-service response; bypassing it is not a way to complete the lift.
- Powered-hoist item Air system Electric system
- Supply Specified pressure and flow Specified electrical supply
- Distribution Hoses and fittings Cables and connections
- Duty Product operating cycle Motor and control duty rating
- Controls Approved pendant/valves Approved pendant or control system
- Failure response Manufacturer’s air-loss procedure Manufacturer’s power/control-loss procedure
- Common force-path checks
Both types need an approved upper support and lower rigging. Include equipment deadweight in the support demand where applicable. A trolley installation also requires beam and wheel compatibility. The rated hoist does not independently approve the runway or clamp.
Keep the load chain or rope straight and correctly reeved. Do not wrap it around the load as a sling, side pull against an obstruction or use the mechanism to drag a load in an unapproved direction. Unexpected resistance can indicate a snag, alignment problem or insufficient capacity.
Supply scenario
An air hoist operates slowly after another crew connects several tools to the same air line. The operator should stop safely and verify supply and operating conditions. Raising compressor pressure beyond the hoist limit or pulling the payload by hand while operating the hoist is not an approved remedy.
For an electric example, repeated lifting trips a protective device. The correct response is assessment of duty, supply, load and equipment condition by authorized personnel. Resetting repeatedly or bypassing protection can conceal the cause and expose the load to loss of control.
Operation and isolation
Take slack slowly, verify seating and conduct the required functional and trial checks. Keep personnel clear and maintain effective signals when required. Controls should command deliberate movement rather than sudden repeated starts that shock the system.
Before maintenance, follow the applicable isolation and lockout/tagout procedures. A stopped pendant does not establish that stored pressure or electrical energy is isolated. Operators should report defects and place equipment out of use through the prescribed process, not repair a loaded mechanism.
After stable landing, release and remove gear safely. Inspect for new damage and store or park the hoist according to its manual. The complete powered system must remain identifiable, maintained and suitable for the next task.
Sources: CCO powered-hoist topics , CMCO hoist manuals , CMCO equipment catalog .