Study guide

9.1 Select and Use Wire-Rope Slings

NCCCO Rigger Level II Exam

Track your progress as you read

Finished sections get a check mark.

1 Certification and Exam Preparation

1.1 Current Exam, Eligibility and Scheduling 1.2 Practical Tasks and Examination-Specific Rules 1.3 Study Method, References and Recertification

2 Identify and Measure the Load

2.1 Load Identity, Dimensions and Units 2.2 Load Weight, Density and Complete Inventories 2.3 Composition, Structural Integrity and Special Handling

3 Center of Gravity and Support Geometry

3.1 Center of Gravity and Suspended Stability 3.2 Attachment Points and Complete Force Paths 3.3 Final Position, Landing Supports and Derigging Access

4 Route and Site Hazards

4.1 Travel Path, Clearance and Work-Zone Control 4.2 Power Lines, Clearance Options and Electrical Response 4.3 Weather, Temperature and Ground Conditions

5 Team Duties and Communications

5.1 Signalperson Duties and Reliable Signals 5.2 Equipment Operator Duties and Capacity Decisions 5.3 Lift Director, Qualified Rigger and Hazard Communication

6 Equipment Requirements and Lift Planning

6.1 Determine Equipment Requirements and Compatibility 6.2 Written Plans, Sequence and Change Control 6.3 Critical-Lift Criteria, Risk and Contingencies

7 Balanced Sling Forces

7.1 Two-Leg Tension and Angle Reference 7.2 Length-to-Height Geometry and Headroom 7.3 Horizontal Forces and Attachment Demand

8 Composite and Unequal Loads

8.1 Composite Center of Gravity by Moments 8.2 Off-Center Reactions and Compatible Sling Geometry 8.3 Three- and Four-Leg Assemblies and Load Sharing

9 Wire Rope, Chain and Metal Mesh Slings

9.1 Select and Use Wire-Rope Slings 9.2 Alloy-Chain Assemblies and Approved Adjustment 9.3 Metal-Mesh Slings: Selection, Contact and Removal

10 Synthetic Rope, Web and Roundslings

10.1 Synthetic-Rope Slings and Approved Splices 10.2 Synthetic-Web Slings and Material Compatibility 10.3 Roundslings, Core Protection and Performance Fibers

11 Hitch Application and Sling Protection

11.1 Vertical and Basket Hitch Capacity 11.2 Choker Hitches, Choke Angle and Bundles 11.3 Softeners, Bend Protection and Cut Protection

12 Shackles, Hooks and Collector Hardware

12.1 Shackle Types, Pin Seating and Side Loading 12.2 Hooks, Latches and Permitted Load Seating 12.3 Master Links, Rings and Swivels

13 Threaded Points and Adjustable Hardware

13.1 Eyebolts, Shoulder Seating and Angular Demand 13.2 Swivel Hoist Rings and Installation Torque 13.3 Turnbuckles and Chain Hardware in Adjustable Systems

14 Compression Hardware and Rigging Blocks

14.1 Wire-Rope Clips and Permitted Terminations 14.2 Wedge Sockets, Rope Alignment and Tail Security 14.3 Rigging Blocks, Resultants and Reeving

15 Manual, Lever and Powered Hoists

15.1 Manual Chain Falls and Vertical Hoisting 15.2 Lever Hoists, Pulling Direction and Controlled Adjustment 15.3 Air and Electric Hoists: Supply, Duty and Controls

16 Jacks, Rollers and Portable Supports

16.1 Jacks, Toe Ratings and Positive Support 16.2 Dollies, Skates, Rollers and Horizontal Control 16.3 A-Frames, Gantries and Trolley Compatibility

17 Structural Lifters and Clamps

17.1 Lifting Beams, Spreaders and Configuration Ratings 17.2 Plate Clamps, Material Limits and Grip Conditions 17.3 Beam Clamps as Attachments and Beam/Girder Lifters

18 Mechanical, Vacuum and Magnetic Devices

18.1 Mechanical and Vacuum Lifting Devices 18.2 Close-Proximity and Remotely Operated Lifting Magnets 18.3 Scrap and Material-Handling Grapples

19 Inspection, Removal and Records

19.1 Inspecting All Six Sling Families 19.2 Hook and Rigging-Hardware Inspection 19.3 Below-the-Hook Device Inspection and Testing

20 Lift Control, Rotation and Completion

20.1 Take-Up, Trial Lift and Load Control 20.2 Controlled Rotation, Upending and Multiple-Crane Lifts 20.3 Secure the Load, Remove Rigging and Stow Equipment

21 Technical Standards and Crane Capacity

21.1 Apply the Correct Standard and Regulatory Scope 21.2 Crane Charts, Suspended Weight and Capacity Deductions 21.3 Personnel Hoisting Under OSHA 1926.1431

9.1 Select and Use Wire-Rope Slings

Key Takeaways Explain This Topic AI

Diameter alone does not identify wire-rope sling capacity.

Use the manufacturer’s applicable D/d guidance and avoid applying a factor twice.

OSHA construction rules prohibit sling or bridle eyes formed with clips or knots.

Last updated: October 2026

Recognize the complete rated assembly

A wire-rope sling is an assembly of rope and approved terminations used to support a load. Rope construction, grade, core, size, termination and hitch affect its rated capacity and handling characteristics. A nominal diameter alone does not identify an interchangeable sling.

Wire rope consists of wires arranged into strands around a core. A fiber core and an independent wire-rope core have different behavior and temperature limitations. Construction influences flexibility, abrasion resistance and bending performance. Use the assembly identification and manufacturer information rather than estimating rating from the number of visible strands.

Common terminations include mechanically formed eyes, hand-spliced eyes and sockets in approved assemblies. The termination is part of the rating. A damaged sleeve is a removal/evaluation issue; it does not provide an unused percentage of rope strength that may safely be consumed. Never teach that an impaired eye remains usable because its original termination efficiency exceeded the working load.

Read the relevant capacity

The vertical , choker and basket ratings describe different load paths. A vertical single leg carries its full applied tension. A choker has bending and contact at the choke and uses its applicable rating. A basket can use two supporting portions, but capacity depends on angle, bend diameter, balance and the rated arrangement.

  • Selection input Why it matters
  • Rope construction and size Identifies the applicable assembly table
  • Core and terminations Affect permitted service and assembly rating
  • Hitch Selects the relevant capacity basis
  • Sling angle Changes the demanded tension or rated total
  • Bend diameter Can reduce permissible capacity
  • Contact surface May require protection against damage

Do not multiply a table rating by a factor already included in its heading. If a table gives a two-leg assembly WLL at 45 degrees, its angle effect is already included. If it gives a single-leg vertical WLL, compare it with the calculated inclined leg tension or use an explicitly provided conversion. Mixing these approaches can double-derate or overrate the system.

Understand bend ratio

D/d compares the diameter of the object or bearing surface around which the sling bends, D, with the rope diameter, d. A smaller bend makes rope work harder and can reduce rated sling capacity. The applicable manufacturer bend guidance and table basis control the adjustment. There is no one D/d factor table valid for every rope construction, hitch and eye.

If an exercise explicitly supplies an unadjusted basket rating of 12,000 lb and an applicable bend factor of 0.80, the adjusted rating is 9,600 lb. Apply this only when the factor is required and not already included. It is not permission to use the same 0.80 factor on another diameter or construction.

Check eye bending and body bending separately where the instructions distinguish them. A sling body around a small pipe and its eye around a small hook present different contact conditions. A thimble protects an approved eye geometry but does not eliminate all other bend limitations.

Install without damaging the rope

Avoid kinks, twists, crushing and abrasion. Do not drag a loaded sling across a sharp edge, hammer a kink straight or pull the sling from beneath a landed load. Position the sling so its body and eyes follow the permitted path and protection remains in place. Hands must remain clear as tension develops.

A basket must be balanced to prevent slipping. A choker must tighten in its intended location without bearing the splice or fitting improperly against the load. Long bundles need a method that retains all pieces, not a belief that friction alone will prevent every loose piece from escaping.

OSHA 1926.251 prohibits forming sling or bridle eyes with wire-rope clips or knots. The blueprint’s separate clip topic concerns permitted rope terminations in their applicable uses; it does not authorize construction of a clip-made sling eye in conflict with that regulation. Use a compliant fabricated sling rather than field improvisation.

Inspect and protect the assembly

Look for broken wires, kinks, birdcaging, crushed areas, severe corrosion, heat damage and damaged attachments. A glove can help protect against sharp wires, but do not draw bare hands along the rope. Identify damage over the complete length and at terminations. The inspection chapter distinguishes ASME and OSHA broken-wire criteria instead of applying one number to every rope use.

For temperature, the cited OSHA rules require permanent removal of fiber-core slings exposed above 200°F. Non-fiber-core wire rope used above 400°F or below −60°F requires manufacturer recommendations. Do not apply a generic heat derating without checking the complete assembly and its fittings.

Selection scenario

Two slings have the same diameter, but one has a different core, construction and hitch rating. The rigger cannot substitute it based on appearance. Confirm its applicable WLL, bend limits and service conditions, recalculate if the geometry changes, and verify that its eye fits the selected hardware. After use, store it to avoid corrosion, kinking and mechanical damage, preserving readable identification.

Sources: CCO reference booklet , OSHA construction rigging , CMCO sling guidance .