Study guide

18.2 Close-Proximity and Remotely Operated Lifting Magnets

NCCCO Rigger Level II Exam

Track your progress as you read

Finished sections get a check mark.

1 Certification and Exam Preparation

1.1 Current Exam, Eligibility and Scheduling 1.2 Practical Tasks and Examination-Specific Rules 1.3 Study Method, References and Recertification

2 Identify and Measure the Load

2.1 Load Identity, Dimensions and Units 2.2 Load Weight, Density and Complete Inventories 2.3 Composition, Structural Integrity and Special Handling

3 Center of Gravity and Support Geometry

3.1 Center of Gravity and Suspended Stability 3.2 Attachment Points and Complete Force Paths 3.3 Final Position, Landing Supports and Derigging Access

4 Route and Site Hazards

4.1 Travel Path, Clearance and Work-Zone Control 4.2 Power Lines, Clearance Options and Electrical Response 4.3 Weather, Temperature and Ground Conditions

5 Team Duties and Communications

5.1 Signalperson Duties and Reliable Signals 5.2 Equipment Operator Duties and Capacity Decisions 5.3 Lift Director, Qualified Rigger and Hazard Communication

6 Equipment Requirements and Lift Planning

6.1 Determine Equipment Requirements and Compatibility 6.2 Written Plans, Sequence and Change Control 6.3 Critical-Lift Criteria, Risk and Contingencies

7 Balanced Sling Forces

7.1 Two-Leg Tension and Angle Reference 7.2 Length-to-Height Geometry and Headroom 7.3 Horizontal Forces and Attachment Demand

8 Composite and Unequal Loads

8.1 Composite Center of Gravity by Moments 8.2 Off-Center Reactions and Compatible Sling Geometry 8.3 Three- and Four-Leg Assemblies and Load Sharing

9 Wire Rope, Chain and Metal Mesh Slings

9.1 Select and Use Wire-Rope Slings 9.2 Alloy-Chain Assemblies and Approved Adjustment 9.3 Metal-Mesh Slings: Selection, Contact and Removal

10 Synthetic Rope, Web and Roundslings

10.1 Synthetic-Rope Slings and Approved Splices 10.2 Synthetic-Web Slings and Material Compatibility 10.3 Roundslings, Core Protection and Performance Fibers

11 Hitch Application and Sling Protection

11.1 Vertical and Basket Hitch Capacity 11.2 Choker Hitches, Choke Angle and Bundles 11.3 Softeners, Bend Protection and Cut Protection

12 Shackles, Hooks and Collector Hardware

12.1 Shackle Types, Pin Seating and Side Loading 12.2 Hooks, Latches and Permitted Load Seating 12.3 Master Links, Rings and Swivels

13 Threaded Points and Adjustable Hardware

13.1 Eyebolts, Shoulder Seating and Angular Demand 13.2 Swivel Hoist Rings and Installation Torque 13.3 Turnbuckles and Chain Hardware in Adjustable Systems

14 Compression Hardware and Rigging Blocks

14.1 Wire-Rope Clips and Permitted Terminations 14.2 Wedge Sockets, Rope Alignment and Tail Security 14.3 Rigging Blocks, Resultants and Reeving

15 Manual, Lever and Powered Hoists

15.1 Manual Chain Falls and Vertical Hoisting 15.2 Lever Hoists, Pulling Direction and Controlled Adjustment 15.3 Air and Electric Hoists: Supply, Duty and Controls

16 Jacks, Rollers and Portable Supports

16.1 Jacks, Toe Ratings and Positive Support 16.2 Dollies, Skates, Rollers and Horizontal Control 16.3 A-Frames, Gantries and Trolley Compatibility

17 Structural Lifters and Clamps

17.1 Lifting Beams, Spreaders and Configuration Ratings 17.2 Plate Clamps, Material Limits and Grip Conditions 17.3 Beam Clamps as Attachments and Beam/Girder Lifters

18 Mechanical, Vacuum and Magnetic Devices

18.1 Mechanical and Vacuum Lifting Devices 18.2 Close-Proximity and Remotely Operated Lifting Magnets 18.3 Scrap and Material-Handling Grapples

19 Inspection, Removal and Records

19.1 Inspecting All Six Sling Families 19.2 Hook and Rigging-Hardware Inspection 19.3 Below-the-Hook Device Inspection and Testing

20 Lift Control, Rotation and Completion

20.1 Take-Up, Trial Lift and Load Control 20.2 Controlled Rotation, Upending and Multiple-Crane Lifts 20.3 Secure the Load, Remove Rigging and Stow Equipment

21 Technical Standards and Crane Capacity

21.1 Apply the Correct Standard and Regulatory Scope 21.2 Crane Charts, Suspended Weight and Capacity Deductions 21.3 Personnel Hoisting Under OSHA 1926.1431

18.2 Close-Proximity and Remotely Operated Lifting Magnets

Key Takeaways Explain This Topic AI

Close-proximity versus remote describes control location, not the magnetic power principle.

Air gaps and thin material can reduce rated holding capacity.

Do not assume a magnet approved for one plate will retain a stack.

Last updated: October 2026

Magnetic attraction is conditional

A lifting magnet retains a suitable ferromagnetic load through magnetic attraction. The nameplate rating applies under defined material, thickness, contact and operating conditions. It is not a guaranteed capacity on every steel object, and it does not apply to nonmagnetic materials merely because they are metal.

The blueprint names both close-proximity operated magnets and remotely operated magnets . A close-proximity device requires a person near the magnet to operate its handle or control. A remotely operated device allows control from a separated station or transmitted command. This distinction affects access, release protection, communication and exposure; it does not identify whether the magnet is permanent or electrically energized.

A permanent magnet can retain a load without continuous electrical power, although a powered switching mechanism may be present in some designs. An electromagnet needs its designed electrical supply and may have a specified backup system. Do not claim that all magnets release immediately on loss of site power or that all retain indefinitely. Read the exact operating and emergency instructions.

Select for the actual contact conditions

Verify material suitability, load weight, dimensions, thickness, surface condition, flatness or curvature, temperature and CG. Thin material may have reduced capacity. Rust, paint, mill scale, dirt and uneven contact can introduce an air gap , reducing the magnetic circuit's effectiveness. A rating obtained on a thick clean test plate cannot automatically be transferred to a thin painted sheet.

Magnets for flat plate and round stock may have different rated capacities and contact geometry. A long flexible plate can peel away from the magnet even when its total weight is low. Use the specified minimum thickness, layout and derating chart; no single percentage accounts for all combinations of air gap and thickness.

  • Question Evidence needed
  • Is the material magnetically suitable? Identified material and manufacturer approval
  • Is the surface suitable? Contact condition and permitted air-gap limits
  • Is the load thick and stiff enough? Product thickness and geometry ratings
  • Can it rotate safely? Approval for the proposed orientation and motion
  • Will multiple magnets share? Approved assembly and individual load distribution

Do not lift several stacked plates unless the device and procedure expressly permit that application. Attraction through the top plate does not establish reliable retention of every lower sheet. Likewise, loose attached pieces can fall independently of the main magnetic load.

Close-proximity operation

Plan safe access to position and activate the magnet while the load is supported. Follow the manufacturer's handle, latch or interlock procedure. A switching lever must be secured in the operating position as specified; a lever that cannot lock correctly is a stop condition.

After activation, move clear before weight is taken. Never ride with the magnet, use the handle to steady a suspended load or reach below the payload to check contact. The close-proximity operator needs a protected retreat path, particularly when the load may swing or rotate during take-up.

At the destination, land and support the load fully before approaching to release. Confirm the load cannot roll, tip or slide when magnetic attraction is removed. Follow the release sequence without forcing a jammed lever or bypassing a safety catch. Keep body parts away from pinch points between the magnet and steel.

Remote operation

Remote controls must be identifiable, functioning and protected from unintended release. Test the command and indications according to the instructions before a loaded operation. Verify the operator can distinguish the selected magnet, attachment state and release command. A wireless signal reaching the device does not prove that the load is securely attached.

Arrange communication with the crane operator and signalperson. Keep control of the release function assigned, and establish what happens on control loss, power loss or low reserve indication. Follow the manufacturer's emergency procedure rather than cycling the release control to diagnose a suspended magnet.

A remotely operated magnet can remove the need to stand next to the load during activation, but the route and destination still need exclusion areas. People must not pass beneath the load because the operator is distant. Use the intended alarms or backup indications and stop if the required monitoring is unavailable.

Rating example

A supplied product chart permits 1,000 lb on the proposed material and thickness after its stated surface reduction. The magnet itself weighs 180 lb. An 850-lb item is below that stated magnetic limit, but the crane must account for at least 1,030 lb from those two items. The comparison remains conditional on the load's geometry, contact and approved orientation. A 1,200-lb rating from a different thickness row cannot replace the applicable 1,000-lb value.

Inspection and handling

Inspect identification, structural members, lifting connection, magnet face, operating mechanism, locks, cables, connectors and power/backup system as applicable. Damage, overheating, loose connections, unreliable controls or a rough damaged contact face require assessment before use. Keep surfaces clean by the specified method; grinding a damaged face can alter its designed geometry.

Make the specified controlled trial lift in a protected area. Watch for incomplete contact, sliding or movement of attached pieces. Avoid impact and sudden acceleration. After landing, release deliberately and store the magnet so its face, cables and control mechanism are protected. Inspection frequency and records belong to the applicable ASME B30.20 program and manufacturer guidance, rather than an invented universal test before every lift.

Sources: CCO reference manual, lifting-magnet provisions , CMCO magnet application guidance .