Study guide

18.1 Mechanical and Vacuum Lifting Devices

NCCCO Rigger Level II Exam

Track your progress as you read

Finished sections get a check mark.

1 Certification and Exam Preparation

1.1 Current Exam, Eligibility and Scheduling 1.2 Practical Tasks and Examination-Specific Rules 1.3 Study Method, References and Recertification

2 Identify and Measure the Load

2.1 Load Identity, Dimensions and Units 2.2 Load Weight, Density and Complete Inventories 2.3 Composition, Structural Integrity and Special Handling

3 Center of Gravity and Support Geometry

3.1 Center of Gravity and Suspended Stability 3.2 Attachment Points and Complete Force Paths 3.3 Final Position, Landing Supports and Derigging Access

4 Route and Site Hazards

4.1 Travel Path, Clearance and Work-Zone Control 4.2 Power Lines, Clearance Options and Electrical Response 4.3 Weather, Temperature and Ground Conditions

5 Team Duties and Communications

5.1 Signalperson Duties and Reliable Signals 5.2 Equipment Operator Duties and Capacity Decisions 5.3 Lift Director, Qualified Rigger and Hazard Communication

6 Equipment Requirements and Lift Planning

6.1 Determine Equipment Requirements and Compatibility 6.2 Written Plans, Sequence and Change Control 6.3 Critical-Lift Criteria, Risk and Contingencies

7 Balanced Sling Forces

7.1 Two-Leg Tension and Angle Reference 7.2 Length-to-Height Geometry and Headroom 7.3 Horizontal Forces and Attachment Demand

8 Composite and Unequal Loads

8.1 Composite Center of Gravity by Moments 8.2 Off-Center Reactions and Compatible Sling Geometry 8.3 Three- and Four-Leg Assemblies and Load Sharing

9 Wire Rope, Chain and Metal Mesh Slings

9.1 Select and Use Wire-Rope Slings 9.2 Alloy-Chain Assemblies and Approved Adjustment 9.3 Metal-Mesh Slings: Selection, Contact and Removal

10 Synthetic Rope, Web and Roundslings

10.1 Synthetic-Rope Slings and Approved Splices 10.2 Synthetic-Web Slings and Material Compatibility 10.3 Roundslings, Core Protection and Performance Fibers

11 Hitch Application and Sling Protection

11.1 Vertical and Basket Hitch Capacity 11.2 Choker Hitches, Choke Angle and Bundles 11.3 Softeners, Bend Protection and Cut Protection

12 Shackles, Hooks and Collector Hardware

12.1 Shackle Types, Pin Seating and Side Loading 12.2 Hooks, Latches and Permitted Load Seating 12.3 Master Links, Rings and Swivels

13 Threaded Points and Adjustable Hardware

13.1 Eyebolts, Shoulder Seating and Angular Demand 13.2 Swivel Hoist Rings and Installation Torque 13.3 Turnbuckles and Chain Hardware in Adjustable Systems

14 Compression Hardware and Rigging Blocks

14.1 Wire-Rope Clips and Permitted Terminations 14.2 Wedge Sockets, Rope Alignment and Tail Security 14.3 Rigging Blocks, Resultants and Reeving

15 Manual, Lever and Powered Hoists

15.1 Manual Chain Falls and Vertical Hoisting 15.2 Lever Hoists, Pulling Direction and Controlled Adjustment 15.3 Air and Electric Hoists: Supply, Duty and Controls

16 Jacks, Rollers and Portable Supports

16.1 Jacks, Toe Ratings and Positive Support 16.2 Dollies, Skates, Rollers and Horizontal Control 16.3 A-Frames, Gantries and Trolley Compatibility

17 Structural Lifters and Clamps

17.1 Lifting Beams, Spreaders and Configuration Ratings 17.2 Plate Clamps, Material Limits and Grip Conditions 17.3 Beam Clamps as Attachments and Beam/Girder Lifters

18 Mechanical, Vacuum and Magnetic Devices

18.1 Mechanical and Vacuum Lifting Devices 18.2 Close-Proximity and Remotely Operated Lifting Magnets 18.3 Scrap and Material-Handling Grapples

19 Inspection, Removal and Records

19.1 Inspecting All Six Sling Families 19.2 Hook and Rigging-Hardware Inspection 19.3 Below-the-Hook Device Inspection and Testing

20 Lift Control, Rotation and Completion

20.1 Take-Up, Trial Lift and Load Control 20.2 Controlled Rotation, Upending and Multiple-Crane Lifts 20.3 Secure the Load, Remove Rigging and Stow Equipment

21 Technical Standards and Crane Capacity

21.1 Apply the Correct Standard and Regulatory Scope 21.2 Crane Charts, Suspended Weight and Capacity Deductions 21.3 Personnel Hoisting Under OSHA 1926.1431

18.1 Mechanical and Vacuum Lifting Devices

Key Takeaways Explain This Topic AI

Device capacity does not prove that the load shape and contact conditions are suitable.

Include the below-the-hook device weight in the applicable crane load inventory.

Land and secure the load before operating a release mechanism.

Last updated: October 2026

Match the retaining method to the load

A mechanical lifting device retains a load through a designed geometry, engagement or gripping mechanism. Examples include C-hooks for coils, pallet lifters and purpose-built grabs. A vacuum lifter retains a suitable surface through a pressure difference across its pads. Both are below-the-hook devices, but they solve different load-handling problems and have different failure modes.

A coil lifter needs the specified coil dimensions, weight, orientation and CG range. A pallet lifter needs a stable, retained load on an appropriate pallet; fork capacity alone does not secure loose packages. A scissor grab needs the approved dimensions, contact conditions and operating sequence. Do not assume every mechanical device relies on friction, or that every grab remains locked after hoist tension is removed.

A vacuum lifter may be useful when attaching slings would damage a finished surface or when glass or sheet material lacks conventional lifting points. It must be intended for overhead lifting of that material. Hand-held vacuum cups and a below-the-hook lifting frame have different applications; hand cups do not become an approved crane lifter by attaching several to a sling.

Mechanical selection and operation

Verify the device's rated load, self-weight, dimensional range, load orientation, suspension connection and opening/closing mechanism. Determine how the load is captured and what could release it. A C-hook supporting a coil from its bore has a defined load position and counterbalance; extending its nose or using it on a different shape can shift the load outside the approved geometry.

Before lift-off, engage the mechanism fully according to the instructions. Keep hands clear of moving jaws and locking parts. Inspect for cracks, bent members, missing pins, damaged contact surfaces or an unreliable lock. A device that sometimes catches is defective even if it looks structurally intact.

During travel, avoid shock, collision and unapproved rotation. Observe engagement from a protected position. To release, first land and support the load, then operate the mechanism as directed. Never trigger release while someone is beneath a retained load or use a worker's hands to prevent the grab opening.

Vacuum selection variables

Vacuum capacity depends on more than the plate or glass weight. The proposed pad arrangement must suit dimensions, stiffness, curvature and surface condition. The lifter must also be rated for the planned horizontal, vertical or tilted orientation. Supporting a sheet horizontally and resisting sliding on a vertical sheet impose different demands.

  • Variable Why it matters
  • Porosity and surface texture Leakage may prevent adequate vacuum or shorten retention time
  • Oil, moisture or contamination Can reduce seal quality and sliding resistance
  • Pad condition and placement Damaged pads or inadequate coverage can lose retention
  • Flexible or cracked material Local pad loading may damage the load despite adequate weight rating
  • Temperature and elevation Can affect seals, pump performance and available pressure difference
  • Orientation and CG Changes pad demand, sliding tendency and bending

Use the manufacturer's selection worksheet and operating manual. Do not assign a universal vacuum value, pad spacing or emergency holding time. Some systems have independent circuits, reserve tanks and alarms; the actual arrangement determines the tests and response. A reserve tank does not guarantee retention on a leaking or unsuitable surface.

Inspection and readiness

Inspect pads, sealing lips, frame, hoses, fittings, filters, gauges, valves, alarms, battery or power supply and motion locks. Complete the specified vacuum and leakage tests. Establish that indications are readable by the person responsible for monitoring them and that the release control cannot be activated accidentally.

Check the charge or power condition before beginning. A powered pump may maintain a marginal seal until power is lost; that does not prove the load will remain attached during an outage. Plan a nearby safe landing area and a response to low vacuum, alarm or failed power. Keep personnel clear throughout the lift because retention can deteriorate quickly.

Selection example

A 900-lb polished panel is within a lifter's stated 1,200-lb capacity for vertical handling. The proposed pads lie partly over joints, and the panel's finish is damp. The numerical comparison alone is insufficient. Confirm the approved pad layout, soundness and surface conditions; clean and dry only by the permitted method, and complete the required tests. If these conditions cannot be met, select a different approved lifting method.

For the crane load inventory, include the lifter's self-weight. If the approved device weighs 350 lb, the panel and device contribute 1,250 lb before the separately applicable hook, rigging and load-line items. A device rating and a crane chart answer different capacity questions.

Lifting and release sequence

Position the pads on approved contact areas without dragging them across sharp features. Activate attachment, verify adequate vacuum and indications, and make the planned low trial lift. Check load balance and stability without reaching under the panel. Monitor vacuum continuously as required by the instructions while maintaining the exclusion area.

For an alarm, stop and follow the prescribed controlled landing response; do not continue to a distant destination on an assumed reserve time. Before intentional release, confirm that the panel is supported against tipping or sliding and that its weight has transferred to the destination. Release pads only through the designed control sequence. Store pads and the frame so sealing surfaces, hoses and controls remain protected.

Sources: CCO reference manual, ASME B30.20 extracts , WPG lifter selection , WPG operating resources .