Study guide

8.1 Composite Center of Gravity by Moments

NCCCO Rigger Level II Exam

Track your progress as you read

Finished sections get a check mark.

1 Certification and Exam Preparation

1.1 Current Exam, Eligibility and Scheduling 1.2 Practical Tasks and Examination-Specific Rules 1.3 Study Method, References and Recertification

2 Identify and Measure the Load

2.1 Load Identity, Dimensions and Units 2.2 Load Weight, Density and Complete Inventories 2.3 Composition, Structural Integrity and Special Handling

3 Center of Gravity and Support Geometry

3.1 Center of Gravity and Suspended Stability 3.2 Attachment Points and Complete Force Paths 3.3 Final Position, Landing Supports and Derigging Access

4 Route and Site Hazards

4.1 Travel Path, Clearance and Work-Zone Control 4.2 Power Lines, Clearance Options and Electrical Response 4.3 Weather, Temperature and Ground Conditions

5 Team Duties and Communications

5.1 Signalperson Duties and Reliable Signals 5.2 Equipment Operator Duties and Capacity Decisions 5.3 Lift Director, Qualified Rigger and Hazard Communication

6 Equipment Requirements and Lift Planning

6.1 Determine Equipment Requirements and Compatibility 6.2 Written Plans, Sequence and Change Control 6.3 Critical-Lift Criteria, Risk and Contingencies

7 Balanced Sling Forces

7.1 Two-Leg Tension and Angle Reference 7.2 Length-to-Height Geometry and Headroom 7.3 Horizontal Forces and Attachment Demand

8 Composite and Unequal Loads

8.1 Composite Center of Gravity by Moments 8.2 Off-Center Reactions and Compatible Sling Geometry 8.3 Three- and Four-Leg Assemblies and Load Sharing

9 Wire Rope, Chain and Metal Mesh Slings

9.1 Select and Use Wire-Rope Slings 9.2 Alloy-Chain Assemblies and Approved Adjustment 9.3 Metal-Mesh Slings: Selection, Contact and Removal

10 Synthetic Rope, Web and Roundslings

10.1 Synthetic-Rope Slings and Approved Splices 10.2 Synthetic-Web Slings and Material Compatibility 10.3 Roundslings, Core Protection and Performance Fibers

11 Hitch Application and Sling Protection

11.1 Vertical and Basket Hitch Capacity 11.2 Choker Hitches, Choke Angle and Bundles 11.3 Softeners, Bend Protection and Cut Protection

12 Shackles, Hooks and Collector Hardware

12.1 Shackle Types, Pin Seating and Side Loading 12.2 Hooks, Latches and Permitted Load Seating 12.3 Master Links, Rings and Swivels

13 Threaded Points and Adjustable Hardware

13.1 Eyebolts, Shoulder Seating and Angular Demand 13.2 Swivel Hoist Rings and Installation Torque 13.3 Turnbuckles and Chain Hardware in Adjustable Systems

14 Compression Hardware and Rigging Blocks

14.1 Wire-Rope Clips and Permitted Terminations 14.2 Wedge Sockets, Rope Alignment and Tail Security 14.3 Rigging Blocks, Resultants and Reeving

15 Manual, Lever and Powered Hoists

15.1 Manual Chain Falls and Vertical Hoisting 15.2 Lever Hoists, Pulling Direction and Controlled Adjustment 15.3 Air and Electric Hoists: Supply, Duty and Controls

16 Jacks, Rollers and Portable Supports

16.1 Jacks, Toe Ratings and Positive Support 16.2 Dollies, Skates, Rollers and Horizontal Control 16.3 A-Frames, Gantries and Trolley Compatibility

17 Structural Lifters and Clamps

17.1 Lifting Beams, Spreaders and Configuration Ratings 17.2 Plate Clamps, Material Limits and Grip Conditions 17.3 Beam Clamps as Attachments and Beam/Girder Lifters

18 Mechanical, Vacuum and Magnetic Devices

18.1 Mechanical and Vacuum Lifting Devices 18.2 Close-Proximity and Remotely Operated Lifting Magnets 18.3 Scrap and Material-Handling Grapples

19 Inspection, Removal and Records

19.1 Inspecting All Six Sling Families 19.2 Hook and Rigging-Hardware Inspection 19.3 Below-the-Hook Device Inspection and Testing

20 Lift Control, Rotation and Completion

20.1 Take-Up, Trial Lift and Load Control 20.2 Controlled Rotation, Upending and Multiple-Crane Lifts 20.3 Secure the Load, Remove Rigging and Stow Equipment

21 Technical Standards and Crane Capacity

21.1 Apply the Correct Standard and Regulatory Scope 21.2 Crane Charts, Suspended Weight and Capacity Deductions 21.3 Personnel Hoisting Under OSHA 1926.1431

8.1 Composite Center of Gravity by Moments

Key Takeaways Explain This Topic AI

Every component moment uses its own CG coordinate from the same datum.

Pound-feet divided by pounds gives the CG distance in feet.

Added or removed components change both total weight and moment.

Last updated: October 2026

Choose one datum for the calculation

A datum is the reference from which component CG distances are measured. It can be chosen conveniently, provided every distance uses the same reference and direction. Choosing the left end of a skid often avoids negative coordinates, but it is not mathematically mandatory. A consistent signed coordinate system works as well.

For a composite load, multiply each component weight by its own CG distance from the datum. This product is its weight moment. Sum all moments and divide by the total weight: x ˉ = ∑ W i x i ∑ W i \bar{x}=\frac{\sum W_i x_i}{\sum W_i} x ˉ = ∑ W i ​ ∑ W i ​ x i ​ ​

The result is a distance, not a force or a moment. Units verify the operation: pound-feet divided by pounds gives feet. A result expressed in pound-feet after the final division indicates that the calculation has not been completed or the units have been mislabeled.

Work through a complete inventory

A training skid consists of a uniform 20-ft base weighing 4,000 lb, a 6,000-lb transformer whose CG is 5 ft from the left end, and a 2,000-lb pump whose CG is 16 ft from the left end. The base’s own CG is at 10 ft because the problem explicitly defines it as uniform.

  • Component Weight CG distance Moment
  • Uniform base 4,000 lb 10 ft 40,000 lb-ft
  • Transformer 6,000 lb 5 ft 30,000 lb-ft
  • Pump 2,000 lb 16 ft 32,000 lb-ft
  • Total 12,000 lb — 102,000 lb-ft

The composite CG is 102,000/12,000 = 8.5 ft from the left end . It lies toward the heavier transformer relative to the base’s midpoint. From the right end, the distance is 20 − 8.5 = 11.5 ft. These are different coordinates describing the same physical point.

The component’s mounting position is not always its CG. If a motor’s mounting feet are centered at 6 ft but its own CG is offset, use the actual CG coordinate. The problem’s supplied component centers represent their weight application points. Do not replace them with the center of the visible case unless uniformity or manufacturer information establishes that equivalence.

Extend the method to other axes

Apply the same weighted-average method independently for transverse and vertical coordinates. For example, two components weigh 3,000 and 1,000 lb, with vertical CG elevations of 2 and 6 ft above the same base datum. Their composite elevation is (3,000 × 2 + 1,000 × 6)/4,000 = 3 ft . That result informs stability, while the longitudinal coordinate informs support reactions.

A three-dimensional coordinate inventory uses each component’s x, y and z positions. The arithmetic does not change, but the physical interpretation does. Do not use an elevation as a horizontal moment arm in a two-support longitudinal reaction problem.

Handle removed or added components

Adding an accessory changes both total weight and total moment. A 1,000-lb accessory added at 18 ft to the 12,000-lb skid increases moment to 120,000 lb-ft and weight to 13,000 lb. The new CG is approximately 9.231 ft from the datum. Reusing 8.5 ft would describe the old assembly.

Removing a component can be represented by subtracting its weight and moment from a known complete inventory. The remaining weight must be positive and the subtraction must refer to the same datum. This bookkeeping is valid only when the original total and the removed component information are reliable. It does not establish the CG of unknown hidden contents.

Check the answer physically

With positive component weights, a coordinate calculated as a weighted average lies between the smallest and largest component CG coordinates. If all component centers lie between 5 and 16 ft, a result at 22 ft cannot follow from that inventory. Check signs, units, omitted weights and moment sums before proceeding.

A hollow or open-frame object can have a CG in empty space. The weighted-average result need not lie within solid material. An L-shaped frame’s balance point may be outside either individual member. This does not permit attaching directly at an unsupported point; it tells where the resultant weight acts.

From CG to rigging

The computed coordinate must be related to actual picks. If the left pick is 2 ft from the datum, the 8.5-ft CG is 6.5 ft from that pick. If the right pick is at 18 ft, it is 9.5 ft from the CG. Those distances, not 8.5 and 11.5 from the load ends, belong in the support-reaction calculation.

Document the component configuration so the calculation remains traceable. Secure movable masses as approved, confirm retained contents and compare the result with manufacturer information where available. A trial lift then checks observed attitude; it cannot make an inaccurate component inventory reliable.

Treat uncertain and shifting contents separately

A partially filled vessel can change its effective mass distribution as it tilts. The fixed-coordinate weighted average describes only the stated condition; it does not establish the CG for every later attitude. Obtain the approved handling information, drain or secure contents where authorized, or have the changing condition assessed before planning rotation.

An inventory also needs attached guards, accessories and the structural base. Leaving the base out because it appears uniform removes both its weight and its moment from the total. In the skid example, omitting the 4,000-lb base would incorrectly give 62,000/8,000 = 7.75 ft. That arithmetic is internally consistent but describes a different incomplete load.

Source: CCO Level II load-characteristic and calculation scope .