Study guide
11.2 Rigging Math: Sling Angles, Tension Calculations & Center of Gravity
NCCER Boilermaker Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The Assessment, Boilermaker Craft, Safety, Tools & Crew Leadership
1.1 The NCCER Boilermaker Assessments: Format, Content Domains, Scoring & Credentials 1.2 Craft Fundamentals, Professional Roles & Industrial Safety 1.3 Confined Space Entry, Lockout/Tagout (LOTO) & Atmospheric Testing 1.4 Hand, Pneumatic, Electric & Hydraulic Boilermaker Tools 1.5 Crew Leadership, Job Planning, Production Tracking & Jobsite Communication
2 Chapter 2: Metallurgy, Base Materials, Oxyfuel, Air Carbon Arc & Plasma Cutting
2.1 Industrial Boiler Materials, Carbon & Alloy Steels, ASME Material Specs & Markings 2.2 Base Metal Surface Preparation, Joint Beveling & Fit-Up Cleanliness 2.3 Oxyfuel Cutting Principles, Equipment Setup, Torch Angles & Piercing Techniques 2.4 Air Carbon Arc Cutting and Gouging (CAC-A): Electrodes, Current, Air Supply, Technique & Defects 2.5 Plasma Arc Cutting (PAC): Torch Anatomy, Consumables, Gas Selection, Cut Quality & Safety
3 Chapter 3: Boiler Types, Steam Generation, Feedwater & Combustion Systems
3.1 Firetube Boiler Designs, Circulation Patterns & Operating Principles 3.2 Watertube Boiler Configurations, Natural & Forced Circulation, Drum Internals 3.3 Superheaters, Reheaters, Economizers & Air Heaters 3.4 Feedwater Systems, Deaerators, Condensate Return & Boiler Water Treatment 3.5 Combustion Systems: Burners, Stokers, Pulverizers, Fans & Draft Control
4 Chapter 4: Boiler Pressure & Nonpressure Components
4.1 Steam Drums, Mud Drums, Headers & Waterwalls 4.2 Nonpressure Components: Casing, Breeching, Baffles, Buckstays & Expansion Joints 4.3 Boiler Auxiliaries: Soot Blowers, Safety Valves, Gage Glasses & Blowdown Systems
5 Chapter 5: Valves, Gaskets, Fasteners, Anchors & Pipe Support Systems
5.1 Industrial Valve Types, Markings, Operation & Ratings 5.2 Gasket Materials, Flange Facings, Bolt Torque Sequences & Joint Assembly 5.3 Gasket Layout, Cutting & Fitting for Field-Made Gaskets 5.4 Fasteners, Anchors & Threaded Connection Hardware 5.5 Pipe Hangers, Supports, Rigid Restraints & Spring Can Installation/Adjustment
6 Chapter 6: Blueprint Reading, Welding Symbols & Construction Drawings
6.1 AWS Welding Symbols, Joint Geometry, Contours & NDE Designators 6.2 Piping Schematics, P&IDs, Isometric Drawings & Spool Sheets 6.3 Pressure Vessel General Arrangement, Detail Sheets, Coordinates & Elevations
7 Chapter 7: Trade Mathematics & Pipe Layout Calculations
7.1 Boilermaker Mechanical Trade Math: Offsets, Rolling Offsets & Travel Calculations 7.2 Vessel Volume, Surface Area, Circumference & Head Layout Computations 7.3 Mitered Turns, Segment Layout, Cutbacks & Branch Connections
8 Chapter 8: Pipe Fabrication - Socket Weld, Butt Weld, Threaded, Grooved & Spool Work
8.1 Pipe Materials, Nominal Pipe Size, Wall Schedules & Fitting Standards 8.2 Socket Weld Pipe Fabrication: The 1/16 in. Gap, Fillet Sizing & Cut Lengths 8.3 Butt Weld Pipe Fabrication: End Preparation, Alignment, Fit-Up & Cut Lengths 8.4 Pipe Layout Tools, Wrap-Arounds, Flange Squaring & Fabrication Tolerances 8.5 Threaded and Grooved Pipe Joining Systems 8.6 Spool Fabrication Workflow, Shop Versus Field Welds & Advanced Pipe Fabrication
9 Chapter 9: Tube Fabrication, Bending & Rolling
9.1 Boiler Tube Removal, Inspection, Wall Thinning & Replacement Criteria 9.2 Tube Preparation, Bending Radii, Ovality & Alignment Tolerances 9.3 Tube Expanding Mechanics, Rolling Torque Calculations, Wall Reduction & Flaring/Beading
10 Chapter 10: Welding Processes, Preheat & Stress Relieving
10.1 SMAW, GTAW & FCAW Welding Processes in Pressure Vessel Applications 10.2 Electrode Selection, Storage, Baking & AWS Filler Metal Classifications 10.3 Preheating Standards, Interpass Temperature Control & Post-Weld Heat Treatment (PWHT)
11 Chapter 11: Rigging Equipment, Hardware & Crane Operations
11.1 Rigging Hardware: Slings, Shackles, Eye Bolts & Inspection Criteria 11.2 Rigging Math: Sling Angles, Tension Calculations & Center of Gravity 11.3 Crane Signals, Load Charts, Boom Angle Deratings & Critical Lift Planning
12 Chapter 12: Towers, Heat Exchangers & Refractory/BRIL Systems
12.1 Shell-and-Tube Heat Exchangers: Bundles, Baffles & Floating Heads 12.2 Fractionation Towers, Trays, Downcomers, Packing & Vessel Hardware 12.3 Refractory Materials (Brick, Castable, Ceramic Fiber), Anchoring & Lagging (BRIL)
13 Chapter 13: ASME Codes, Quality Assurance, NDE, Pressure Testing & System Cleaning
13.1 ASME Boiler & Pressure Vessel Code (Sections I, VIII, IX) & NBIC Standards 13.2 Quality Control, Material Test Reports (MTRs), Weld Mapping & Traceability 13.3 Nondestructive Examination (NDE): VT, PT, MT, UT, RT & Discontinuity Evaluation 13.4 Hydrostatic and Pneumatic Testing Procedures, Safety Precautions & MAWP Validation 13.5 System Flushing, Chemical Cleaning, Boil-Out, Steam Blows & Service Leak Testing
11.2 Rigging Math: Sling Angles, Tension Calculations & Center of Gravity
Key Takeaways Explain This Topic AI
Sling tension increases dramatically as the horizontal sling angle decreases, governed by the load multiplier formula: Tension Factor = L / H = 1 / sin(theta).
Rigging at horizontal sling angles below 30 degrees is strictly prohibited by ASME B30.9 and OSHA standards without formal engineering review due to extreme, non-linear tension amplification.
A standard choker hitch derates sling capacity to 75% when the choke angle is 120 degrees or greater; choke angles under 120 degrees require severe progressive capacity reductions down to 40%.
When rigging asymmetrical loads, the pick point located closest to the center of gravity (CG) carries the majority of the total weight and experiences the highest sling tension.
For rigid structures lifted with a four-leg bridle, standard engineering practice dictates designing each sling leg assuming only two legs support the entire load unless equalizers are utilized.
Last updated: August 2026
Rigging Math: Sling Angles, Tension Calculations & Center of Gravity
Core Concept: Rigging operations are governed by Newtonian mechanics and vector geometry. When multiple sling legs support a load at an angle, the tension in each leg exceeds the simple static weight divided by the number of legs. Boilermakers must accurately calculate horizontal sling angles, tension factors ( L / H L/H L / H ), choke angle deratings, and center of gravity (CG) offsets to guarantee that no rigging hardware or hoist line is stressed beyond its rated Working Load Limit (WLL).
1. Sling Hitch Configurations & Basic Load Ratings
The manner in which a sling is attached to the load determines its fundamental load-carrying capacity. VERTICAL HITCH CHOKER HITCH BASKET HITCH (D/d >= 25)
- | | / \
- | | / \
- | | / \
- [LOAD] [LOAD] (Choke >= 120 deg) +-------+
- O | [LOAD]| (Vertical legs)
- +-------+
- Capacity = 100% Capacity = 75% - 80% Capacity = 200%
- 1. Vertical Hitch ( 100 % 100\% 100% Baseline Capacity)
A single vertical sling supports the load directly beneath the crane hook. The full tensile capacity of the sling is utilized ( 1.0 × WLL 1.0 \times \text{WLL} 1.0 × WLL ), with zero angular or bending derating.
2. Choker Hitch ( 75 % 75\% 75% to 80 % 80\% 80% Capacity at ≥ 120 ∘ \ge 120^\circ ≥ 12 0 ∘ )
The sling passes around the load, and one eye is threaded through the opposite eye or through a sliding choker hook/shackle. Localized bending stress and radial pinching at the choke point reduce rated capacity to approximately 75 % 75\% 75% of the vertical hitch rating when the choke angle is 120 ∘ 120^\circ 12 0 ∘ or greater .
Choke Angle Derating Factors (ASME B30.9): If the geometry of the load forces the choke angle to be less than 120 ∘ 120^\circ 12 0 ∘ , severe capacity reductions apply:
Choke Angle Range (Degrees) Choke Capacity Factor (% of Vertical WLL)
120 ∘ to 180 ∘ 120^\circ\text{ to }180^\circ 12 0 ∘ to 18 0 ∘ 75 % 75\% 75% to 80 % 80\% 80% (Standard Choker Rating)
- 90 ∘ to 119 ∘ 90^\circ\text{ to }119^\circ 9 0 ∘ to 11 9 ∘ 65 % 65\% 65% ( 87 % 87\% 87% of choker rating)
- 60 ∘ to 89 ∘ 60^\circ\text{ to }89^\circ 6 0 ∘ to 8 9 ∘ 55 % 55\% 55% ( 74 % 74\% 74% of choker rating)
- 30 ∘ to 59 ∘ 30^\circ\text{ to }59^\circ 3 0 ∘ to 5 9 ∘ 45 % 45\% 45% ( 62 % 62\% 62% of choker rating)
- 0 ∘ to 29 ∘ 0^\circ\text{ to }29^\circ 0 ∘ to 2 9 ∘ 30 % 30\% 30% ( 40 % 40\% 40% of choker rating)
Choker Hardware Rule: When using a shackle to create a choker hitch, the bow of the shackle must ride on the sling body , and the shackle pin must be connected to the sling eye. Never force or hammer the choke loop downward to tighten the grip; it must be allowed to settle into its natural angle.
3. Basket Hitch ( 200 % 200\% 200% Capacity at 90 ∘ 90^\circ 9 0 ∘ Vertical Legs)
The sling cradles the load from beneath with both ends connected to the crane hook. If both sling legs are completely vertical ( 90 ∘ 90^\circ 9 0 ∘ to horizontal), the basket hitch provides 200 % 200\% 200% ( 2.0 × WLL 2.0 \times \text{WLL} 2.0 × WLL ) of the single-leg vertical capacity, provided the curvature ratio ( D / d D/d D / d ) meets standards:
D / d D/d D / d Ratio for Wire Rope: The diameter of the curved load surface ( D D D ) divided by the nominal diameter of the wire rope ( d d d ) must be at least 25 : 1 25:1 25 : 1 to achieve 100 % 100\% 100% of basket capacity. Smaller D / d D/d D / d ratios induce severe bending fatigue across outer wires, requiring engineering deratings (e.g., D / d = 10 → 85 % D/d = 10 \rightarrow 85\% D / d = 10 → 85% capacity; D / d = 2 → 65 % D/d = 2 \rightarrow 65\% D / d = 2 → 65% capacity).
2. Sling Angle Tension Physics & Load Multipliers
When a multi-leg sling bridle is used, the horizontal sling angle ( θ \theta θ ) between the sling leg and the top surface of the load determines the total tension in each leg. CRANE HOOK
- /|\
- / | \
- Sling Leg / | \ Sling Leg
- Length (L) / |H \ Length (L)
- / | \
- / | \
- /theta | theta\
- +-------+-------+-------+-------+
- | CG |
- | [ LOAD ] |
- +-------------------------------+
- Sling Angle Load Multiplier Formula
The tension factor ( T F TF TF ), or load multiplier, is the mathematical ratio of the sling length ( L L L ) to the vertical height ( H H H ) from the load pick plane to the crane hook: Tension Factor ( T F ) = Sling Length ( L ) Vertical Height ( H ) = 1 sin θ \text{Tension Factor } (TF) = \frac{\text{Sling Length } (L)}{\text{Vertical Height } (H)} = \frac{1}{\sin\theta} Tension Factor ( TF ) = Vertical Height ( H ) Sling Length ( L ) = sin θ 1
Where θ \theta θ is the horizontal sling angle measured from the horizontal plane to the sling leg.
Standard Sling Angle Multipliers Table
Horizontal Sling Angle ( θ \theta θ ) sin θ \sin\theta sin θ Tension Factor ( T F = 1 / sin θ TF = 1/\sin\theta TF = 1/ sin θ ) Increase in Sling Tension
- 90 ∘ 90^\circ 9 0 ∘ (True Vertical) 1.000 1.000 1.000 1.000 1.000 1.000 0 % 0\% 0% (Base Load)
- 60 ∘ 60^\circ 6 0 ∘ (Standard Ideal) 0.866 0.866 0.866 1.155 1.155 1.155 + 15.5 % +15.5\% + 15.5%
- 50 ∘ 50^\circ 5 0 ∘ 0.766 0.766 0.766 1.305 1.305 1.305 + 30.5 % +30.5\% + 30.5%
- 45 ∘ 45^\circ 4 5 ∘ 0.707 0.707 0.707 1.414 1.414 1.414 + 41.4 % +41.4\% + 41.4%
- 35 ∘ 35^\circ 3 5 ∘ 0.574 0.574 0.574 1.743 1.743 1.743 + 74.3 % +74.3\% + 74.3%
30 ∘ 30^\circ 3 0 ∘ (Absolute Limit) 0.500 0.500 0.500 2.000 2.000 2.000 + 100 % +100\% + 100% (Tension Doubled!)
- 20 ∘ 20^\circ 2 0 ∘ (Unsafe) 0.342 0.342 0.342 2.924 2.924 2.924 + 192.4 % +192.4\% + 192.4%
- 10 ∘ 10^\circ 1 0 ∘ (Extreme Danger) 0.174 0.174 0.174 5.759 5.759 5.759 + 475.9 % +475.9\% + 475.9%
- 5 ∘ 5^\circ 5 ∘ (Near Failure) 0.087 0.087 0.087 11.474 11.474 11.474 + 1 , 047.4 % +1,047.4\% + 1 , 047.4%
CRITICAL RULE (ASME B30.9 & OSHA): Rigging at sling angles less than 30 ∘ 30^\circ 3 0 ∘ from horizontal is strictly prohibited without written engineering approval. As θ \theta θ approaches 0 ∘ 0^\circ 0 ∘ , tension approaches infinity, creating crushing horizontal forces that can collapse vessel walls and snap forged shackles.
Symmetrical Sling Tension Formula
For a symmetrical load where the center of gravity is equidistant between pick points: Tension per Leg ( T ) = ( Total Weight ( W ) Number of Effective Legs ( N ) ) × ( L H ) = W N × sin θ \text{Tension per Leg } (T) = \left(\frac{\text{Total Weight } (W)}{\text{Number of Effective Legs } (N)}\right) \times \left(\frac{L}{H}\right) = \frac{W}{N \times \sin\theta} Tension per Leg ( T ) = ( Number of Effective Legs ( N ) Total Weight ( W ) ) × ( H L ) = N × sin θ W
The Rigid Load / 4-Leg Bridle Rule
When lifting a rigid, non-flexible load (e.g., a thick-walled steam drum, heavy cast valve, or welded rectangular boiler casing) using a 4-leg sling bridle, only two diagonally opposite legs will carry virtually 100 % 100\% 100% of the total load weight , while the other two legs merely provide balance. Unless engineered equalizer beams or adjustable turnbuckles are incorporated, boilermakers must calculate sling tension assuming N = 2 N = 2 N = 2 rather than N = 4 N = 4 N = 4 .
3. Center of Gravity (CG) Determination & Off-Center Tension
The Center of Gravity (CG) is the point about which the entire weight of an object is equally distributed in all directions. When a load is hoisted freely, the crane hook will automatically position itself directly above the load's center of gravity . If the hook is rigged off-center, the load will violently tip and swing until the CG aligns vertically beneath the hook. CRANE HOOK
- |
- v
- ( HOOK )
- / \
- Sling 1 / \ Sling 2
- (L1) / \ (L2)
- / | \
- / | \
- / v \
- Pick 1 +--+------(CG)--------+--+ Pick 2
- | |< d1 >| |< d2 >| |
- | [ ASYMMETRICAL ] |
- +------------------------+
- <------- D --------->
- Calculating Center of Gravity for Compound Objects
For an object composed of multiple components with distinct weights ( W 1 , W 2 , … , W n W_1, W_2, \dots, W_n W 1 , W 2 , … , W n ) and locations ( x 1 , x 2 , … , x n x_1, x_2, \dots, x_n x 1 , x 2 , … , x n ) relative to a reference datum: x ˉ = ∑ ( W i × x i ) ∑ W i = ( W 1 ⋅ x 1 ) + ( W 2 ⋅ x 2 ) + ⋯ + ( W n ⋅ x n ) W total \bar{x} = \frac{\sum (W_i \times x_i)}{\sum W_i} = \frac{(W_1 \cdot x_1) + (W_2 \cdot x_2) + \dots + (W_n \cdot x_n)}{W_{\text{total}}} x ˉ = ∑ W i ∑ ( W i × x i ) = W total ( W 1 ⋅ x 1 ) + ( W 2 ⋅ x 2 ) + ⋯ + ( W n ⋅ x n )
Resolving Tension with an Off-Center Center of Gravity
When the CG is not centered between pick points ( d 1 ≠ d 2 d_1 \ne d_2 d 1 = d 2 ), the vertical load share is unequal. Using static moment equilibrium ( ∑ M = 0 \sum M = 0 ∑ M = 0 ): Vertical Share at Pick Point 1 ( V 1 ) = W × ( d 2 d 1 + d 2 ) = W × ( d 2 D ) \text{Vertical Share at Pick Point 1 } (V_1) = W \times \left(\frac{d_2}{d_1 + d_2}\right) = W \times \left(\frac{d_2}{D}\right) Vertical Share at Pick Point 1 ( V 1 ) = W × ( d 1 + d 2 d 2 ) = W × ( D d 2 ) Vertical Share at Pick Point 2 ( V 2 ) = W × ( d 1 d 1 + d 2 ) = W × ( d 1 D ) \text{Vertical Share at Pick Point 2 } (V_2) = W \times \left(\frac{d_1}{d_1 + d_2}\right) = W \times \left(\frac{d_1}{D}\right) Vertical Share at Pick Point 2 ( V 2 ) = W × ( d 1 + d 2 d 1 ) = W × ( D d 1 )
Where:
W = Total load weight W = \text{Total load weight} W = Total load weight
D = d 1 + d 2 = Total distance between pick points D = d_1 + d_2 = \text{Total distance between pick points} D = d 1 + d 2 = Total distance between pick points
d 1 = Horizontal distance from Pick Point 1 to CG d_1 = \text{Horizontal distance from Pick Point 1 to CG} d 1 = Horizontal distance from Pick Point 1 to CG
d 2 = Horizontal distance from Pick Point 2 to CG d_2 = \text{Horizontal distance from Pick Point 2 to CG} d 2 = Horizontal distance from Pick Point 2 to CG
Once the vertical load shares ( V 1 , V 2 V_1, V_2 V 1 , V 2 ) are calculated, the actual tension in each sling leg is determined by applying the respective sling angle tension factor: T 1 = V 1 × ( L 1 H 1 ) = V 1 sin θ 1 T_1 = V_1 \times \left(\frac{L_1}{H_1}\right) = \frac{V_1}{\sin\theta_1} T 1 = V 1 × ( H 1 L 1 ) = sin θ 1 V 1 T 2 = V 2 × ( L 2 H 2 ) = V 2 sin θ 2 T_2 = V_2 \times \left(\frac{L_2}{H_2}\right) = \frac{V_2}{\sin\theta_2} T 2 = V 2 × ( H 2 L 2 ) = sin θ 2 V 2
Key Principle: The pick point closest to the center of gravity ( d 1 < d 2 d_1 < d_2 d 1 < d 2 ) carries the largest proportion of the weight ( V 1 > V 2 V_1 > V_2 V 1 > V 2 ) and will experience the highest tension force.
- 4. Step-by-Step Worked Numerical Examples
- Example 1: Symmetrical Steam Drum Lift
Given: A utility boiler steam drum weighs 24 , 000 pounds 24,000\text{ pounds} 24 , 000 pounds . It is lifted using a two-leg symmetrical wire rope sling bridle. Each sling leg is 12 feet 12\text{ feet} 12 feet long ( L L L ), and the vertical height ( H H H ) from the lifting lugs to the crane hook is 8.485 feet 8.485\text{ feet} 8.485 feet (corresponding to a horizontal sling angle θ = 45 ∘ \theta = 45^\circ θ = 4 5 ∘ ).
Step 1: Calculate the Tension Factor ( T F TF TF ): T F = L H = 12 ft 8.485 ft = 1.414 ( or 1 sin 45 ∘ = 1 0.7071 = 1.414 ) TF = \frac{L}{H} = \frac{12\text{ ft}}{8.485\text{ ft}} = 1.414 \quad \left(\text{or } \frac{1}{\sin 45^\circ} = \frac{1}{0.7071} = 1.414\right) TF = H L = 8.485 ft 12 ft = 1.414 ( or sin 4 5 ∘ 1 = 0.7071 1 = 1.414 )
Step 2: Calculate Vertical Load per Leg ( V V V ): V = W N = 24 , 000 lbs 2 = 12 , 000 lbs per leg V = \frac{W}{N} = \frac{24,000\text{ lbs}}{2} = 12,000\text{ lbs per leg} V = N W = 2 24 , 000 lbs = 12 , 000 lbs per leg
Step 3: Calculate Actual Tension in Each Sling Leg ( T T T ): T = V × T F = 12 , 000 lbs × 1.414 = 16 , 968 lbs per leg T = V \times TF = 12,000\text{ lbs} \times 1.414 = 16,968\text{ lbs per leg} T = V × TF = 12 , 000 lbs × 1.414 = 16 , 968 lbs per leg
Result: Each sling leg and shackle must have a Working Load Limit (WLL) of at least 17 , 000 pounds 17,000\text{ pounds} 17 , 000 pounds ( 8.5 tons 8.5\text{ tons} 8.5 tons ). Sizing the sling merely for 12 , 000 lbs 12,000\text{ lbs} 12 , 000 lbs would result in a severe overload.
Example 2: Asymmetrical Shell-and-Tube Heat Exchanger
Given: A chemical process heat exchanger weighs 36 , 000 pounds 36,000\text{ pounds} 36 , 000 pounds . The distance between lifting lugs is 20 feet 20\text{ feet} 20 feet ( D D D ). Due to heavy internal tube sheet and channel head forging at End 1, the center of gravity is located 5 feet 5\text{ feet} 5 feet from Lug 1 ( d 1 = 5 ft d_1 = 5\text{ ft} d 1 = 5 ft ) and 15 feet 15\text{ feet} 15 feet from Lug 2 ( d 2 = 15 ft d_2 = 15\text{ ft} d 2 = 15 ft ). Sling Leg 1 is rigged at a 60 ∘ 60^\circ 6 0 ∘ horizontal angle, while Sling Leg 2 is rigged at a 45 ∘ 45^\circ 4 5 ∘ horizontal angle.
Step 1: Calculate Vertical Load Share on Each Lug: V 1 = W × ( d 2 D ) = 36 , 000 lbs × ( 15 ft 20 ft ) = 36 , 000 × 0.75 = 27 , 000 lbs V_1 = W \times \left(\frac{d_2}{D}\right) = 36,000\text{ lbs} \times \left(\frac{15\text{ ft}}{20\text{ ft}}\right) = 36,000 \times 0.75 = 27,000\text{ lbs} V 1 = W × ( D d 2 ) = 36 , 000 lbs × ( 20 ft 15 ft ) = 36 , 000 × 0.75 = 27 , 000 lbs V 2 = W × ( d 1 D ) = 36 , 000 lbs × ( 5 ft 20 ft ) = 36 , 000 × 0.25 = 9 , 000 lbs V_2 = W \times \left(\frac{d_1}{D}\right) = 36,000\text{ lbs} \times \left(\frac{5\text{ ft}}{20\text{ ft}}\right) = 36,000 \times 0.25 = 9,000\text{ lbs} V 2 = W × ( D d 1 ) = 36 , 000 lbs × ( 20 ft 5 ft ) = 36 , 000 × 0.25 = 9 , 000 lbs
Step 2: Determine Tension Factors for Each Leg: T F 1 = 1 sin 60 ∘ = 1 0.866 = 1.155 TF_1 = \frac{1}{\sin 60^\circ} = \frac{1}{0.866} = 1.155 T F 1 = sin 6 0 ∘ 1 = 0.866 1 = 1.155 T F 2 = 1 sin 45 ∘ = 1 0.707 = 1.414 TF_2 = \frac{1}{\sin 45^\circ} = \frac{1}{0.707} = 1.414 T F 2 = sin 4 5 ∘ 1 = 0.707 1 = 1.414
Step 3: Calculate Actual Sling Tension: T 1 = V 1 × T F 1 = 27 , 000 lbs × 1.155 = 31 , 185 lbs T_1 = V_1 \times TF_1 = 27,000\text{ lbs} \times 1.155 = 31,185\text{ lbs} T 1 = V 1 × T F 1 = 27 , 000 lbs × 1.155 = 31 , 185 lbs T 2 = V 2 × T F 2 = 9 , 000 lbs × 1.414 = 12 , 726 lbs T_2 = V_2 \times TF_2 = 9,000\text{ lbs} \times 1.414 = 12,726\text{ lbs} T 2 = V 2 × T F 2 = 9 , 000 lbs × 1.414 = 12 , 726 lbs
Result: Sling Leg 1 experiences 31 , 185 lbs 31,185\text{ lbs} 31 , 185 lbs of tension (requiring a 16 -ton 16\text{-ton} 16 -ton shackle/sling), whereas Sling Leg 2 experiences 12 , 726 lbs 12,726\text{ lbs} 12 , 726 lbs of tension. Lug 1 supports 75 % 75\% 75% of the total load weight.
Example 3: Rigid Boiler Casing with a 4-Leg Bridle
Given: A fabricated steel boiler casing box weighs 28 , 000 pounds 28,000\text{ pounds} 28 , 000 pounds . It is lifted using a 4-leg wire rope bridle hooked into corner pad eyes at a 45 ∘ 45^\circ 4 5 ∘ horizontal sling angle. The casing is extremely rigid with no equalizer assembly.
Engineering Resolution: Because the load is rigid, only 2 legs are assumed to carry the entire load ( N = 2 N = 2 N = 2 ): V design = 28 , 000 lbs 2 = 14 , 000 lbs per leg V_{\text{design}} = \frac{28,000\text{ lbs}}{2} = 14,000\text{ lbs per leg} V design = 2 28 , 000 lbs = 14 , 000 lbs per leg T leg = V design × ( 1 sin 45 ∘ ) = 14 , 000 lbs × 1.414 = 19 , 796 lbs T_{\text{leg}} = V_{\text{design}} \times \left(\frac{1}{\sin 45^\circ}\right) = 14,000\text{ lbs} \times 1.414 = 19,796\text{ lbs} T leg = V design × ( sin 4 5 ∘ 1 ) = 14 , 000 lbs × 1.414 = 19 , 796 lbs
Result: Each of the 4 sling legs must be rated for at least 20 , 000 pounds 20,000\text{ pounds} 20 , 000 pounds ( 10 tons 10\text{ tons} 10 tons ) WLL to prevent structural failure when 2 legs carry the entire load.