1.1 OSHA Regulations & Subpart S Compliance 1.2 NFPA 70E Standards & Arc-Flash Protection 1.3 Lockout/Tagout (LOTO) & Absence-of-Voltage Verification 1.4 Jobsite Hazard Recognition & Fall/Trench Safety

2 Chapter 2: Electrical Theory & AC/DC Fundamentals

2.1 DC Fundamentals, Ohm's Law & Power 2.2 Series, Parallel & Combination Circuits 2.3 AC Fundamentals, Reactance & Magnetism 2.4 Impedance, Power Triangles & Power Factor

3 Chapter 3: NEC Layout, General Requirements & Services

3.1 NEC Structure, Navigation & Article 100 Definitions 3.2 NEC Article 110: General Requirements for Electrical Installations 3.3 NEC Article 230: Services & Service Equipment

4 Chapter 4: Branch Circuits, Feeders & Overcurrent Protection

4.1 Branch Circuits & Feeders 4.2 Commercial Load Calculations 4.3 Overcurrent Protection & Coordination

5 Chapter 5: Conductors, Insulation & Sizing Calculations

5.1 Conductor Construction, Materials & Insulation 5.2 Ampacity Determination & Table 310.16 5.3 Ampacity Derating & Adjustment Calculations 5.4 Conductor Installation, Pulling Tension & Splices

6 Chapter 6: Raceways, Boxes & Conduit Bending

6.1 Raceway Systems & Support Rules 6.2 Conduit Bending Principles & Mathematics 6.3 Raceway Fill Calculations 6.4 Box Sizing & Cable Tray Systems

7 Chapter 7: Commercial Wiring Methods, Devices & Special Occupancies

7.1 Commercial Wiring Devices & Receptacles 7.2 Switching Circuits & Commercial Controls 7.3 Commercial Lighting & Emergency Power Systems 7.4 Hazardous (Classified) Locations

8 Chapter 8: Motors, Motor Circuits & Overload Protection

8.1 Motor Principles & Nameplate Interpretation 8.2 Motor Feeder & Branch-Circuit Conductor Sizing 8.3 Motor Overload & Branch-Circuit Short-Circuit Protection

9 Chapter 9: Motor Controls, Ladder Logic & Industrial Drives

9.1 Magnetic Contactors, Starters & Relays 9.2 Control Circuits & Ladder Logic Schematics 9.3 Variable Frequency Drives (VFDs) & PLC Applications

10 Chapter 10: Transformers & Separately Derived Systems

10.1 Transformer Theory, Ratios & Single-Phase Connections 10.2 Three-Phase Transformer Configurations & Calculations 10.3 Transformer Sizing, Protection & Grounding

11 Chapter 11: Grounding & Bonding Systems (NEC Article 250)

11.1 Fundamental Concepts: Grounding vs. Bonding 11.2 Grounding Electrode System & GEC Sizing 11.3 Equipment Grounding Conductors (EGC) 11.4 Main, System & Supply-Side Bonding Jumpers

12 Chapter 12: Electrical Testing, Troubleshooting & Print Reading

12.1 Electrical Test Instruments & CAT Ratings 12.2 Systematic Circuit Troubleshooting & Fault Analysis 12.3 Electrical Drawings, Specifications & One-Line Diagrams 12.4 Fire Alarm Systems & Specialized Low-Voltage Wiring

2.2 Series, Parallel & Combination Circuits

Key Takeaways Explain This Topic AI

In a series circuit, current remains identical through all components ( I T = I 1 = I 2 = I n I_T = I_1 = I_2 = I_n I T ​ = I 1 ​ = I 2 ​ = I n ​ ), while total resistance equals the direct algebraic sum of individual resistances: R T = R 1 + R 2 + ⋯ + R n R_T = R_1 + R_2 + \dots + R_n R T ​ = R 1 ​ + R 2 ​ + ⋯ + R n ​ .

Kirchhoff's Voltage Law (KVL) dictates that the algebraic sum of all voltages around any closed circuit loop equals zero; source voltage equals the sum of individual component voltage drops.

In a parallel circuit, voltage is constant across all branches ( V T = V 1 = V 2 = V n V_T = V_1 = V_2 = V_n V T ​ = V 1 ​ = V 2 ​ = V n ​ ), while total branch currents sum to equal total supply current per Kirchhoff's Current Law (KCL): I T = I 1 + I 2 + ⋯ + I n I_T = I_1 + I_2 + \dots + I_n I T ​ = I 1 ​ + I 2 ​ + ⋯ + I n ​ .

Equivalent parallel resistance is always lower than the lowest branch resistance, calculated via reciprocal summation or the two-resistor product-over-sum formula: R T = R 1 × R 2 R 1 + R 2 R_T = \frac{R_1 \times R_2}{R_1 + R_2} R T ​ = R 1 ​ + R 2 ​ R 1 ​ × R 2 ​ ​ .

A Wheatstone bridge reaches balance when opposite branch resistance products are equal ( R 1 R 4 = R 2 R 3 R_1 R_4 = R_2 R_3 R 1 ​ R 4 ​ = R 2 ​ R 3 ​ ), producing zero potential difference across the central detector.

Last updated: October 2026

2.2 Series, Parallel & Combination Circuits

Commercial and industrial electrical systems consist of complex arrangements of series, parallel, and combination circuits. Whether evaluating voltage drop across a 300-foot branch circuit, wiring emergency exit signage across multi-pole terminal strips, or analyzing building management system (BMS) bridge sensors, a journey electrician must systematically reduce electrical networks to their equivalent parameters.

Series Circuit Laws & Analysis

A series circuit provides exactly one continuous, unbranching pathway for current flow. Every electron that leaves the power supply source must pass sequentially through every connected load before returning to the source.

1. Current in Series

Because there is only one conductive path, current is uniform at every point along the circuit:

  • I T = I 1 = I 2 = I 3 = ⋯ = I n I_T = I_1 = I_2 = I_3 = \dots = I_n I T ​ = I 1 ​ = I 2 ​ = I 3 ​ = ⋯ = I n ​
  • 2. Resistance in Series

Each added component introduces additional opposition to electron flow. Total series resistance ( R T R_T R T ​ ) equals the direct algebraic sum of all individual resistances:

R T = R 1 + R 2 + R 3 + ⋯ + R n R_T = R_1 + R_2 + R_3 + \dots + R_n R T ​ = R 1 ​ + R 2 ​ + R 3 ​ + ⋯ + R n ​

Total resistance in a series circuit is always strictly greater than the resistance of the largest individual resistor in the circuit.

3. Kirchhoff's Voltage Law (KVL)

Formulated by Gustav Kirchhoff in 1845, Kirchhoff's Voltage Law states that the algebraic sum of all electrical potentials (voltages) around any closed loop must equal zero:

∑ V = 0 ⟹ V S = V 1 + V 2 + V 3 + ⋯ + V n \sum V = 0 \implies V_S = V_1 + V_2 + V_3 + \dots + V_n ∑ V = 0 ⟹ V S ​ = V 1 ​ + V 2 ​ + V 3 ​ + ⋯ + V n ​

In physical terms, the electrical energy injected into the circuit loop by the voltage source ( V S V_S V S ​ ) is completely expended across the series components as individual voltage drops ( V n = I T × R n V_n = I_T \times R_n V n ​ = I T ​ × R n ​ ).

4. The Voltage Divider Rule

In a series circuit, the voltage drop across any individual resistor is directly proportional to its resistance relative to the total circuit resistance:

V x = V S × ( R x R T ) V_x = V_S \times \left(\frac{R_x}{R_T}\right) V x ​ = V S ​ × ( R T ​ R x ​ ​ )

Where:

V x = voltage drop across resistor R x V_x = \text{voltage drop across resistor } R_x V x ​ = voltage drop across resistor R x ​

  • V S = total source voltage V_S = \text{total source voltage} V S ​ = total source voltage
  • R x = resistance of component x R_x = \text{resistance of component } x R x ​ = resistance of component x
  • R T = total series resistance R_T = \text{total series resistance} R T ​ = total series resistance
  • Worked Example: Series Circuit & Voltage Drop

Problem: A 120 V 120\text{V} 120 V DC control source energizes three pilot indicators wired in series having resistances R 1 = 15 Ω R_1 = 15\ \Omega R 1 ​ = 15 Ω , R 2 = 25 Ω R_2 = 25\ \Omega R 2 ​ = 25 Ω , and R 3 = 60 Ω R_3 = 60\ \Omega R 3 ​ = 60 Ω . Determine total resistance, circuit current, and the individual voltage drop across each indicator.

Calculate total series resistance: R T = R 1 + R 2 + R 3 = 15 Ω + 25 Ω + 60 Ω = 100 Ω R_T = R_1 + R_2 + R_3 = 15\ \Omega + 25\ \Omega + 60\ \Omega = 100\ \Omega R T ​ = R 1 ​ + R 2 ​ + R 3 ​ = 15 Ω + 25 Ω + 60 Ω = 100 Ω

Calculate circuit current: I T = V S R T = 120 V 100 Ω = 1.2 Amps I_T = \frac{V_S}{R_T} = \frac{120\text{ V}}{100\ \Omega} = 1.2\text{ Amps} I T ​ = R T ​ V S ​ ​ = 100 Ω 120 V ​ = 1.2 Amps

Calculate individual voltage drops using Ohm's Law (or the Voltage Divider Rule): V 1 = I T × R 1 = 1.2 A × 15 Ω = 18 V V_1 = I_T \times R_1 = 1.2\text{ A} \times 15\ \Omega = 18\text{ V} V 1 ​ = I T ​ × R 1 ​ = 1.2 A × 15 Ω = 18 V V 2 = I T × R 2 = 1.2 A × 25 Ω = 30 V V_2 = I_T \times R_2 = 1.2\text{ A} \times 25\ \Omega = 30\text{ V} V 2 ​ = I T ​ × R 2 ​ = 1.2 A × 25 Ω = 30 V V 3 = I T × R 3 = 1.2 A × 60 Ω = 72 V V_3 = I_T \times R_3 = 1.2\text{ A} \times 60\ \Omega = 72\text{ V} V 3 ​ = I T ​ × R 3 ​ = 1.2 A × 60 Ω = 72 V

Verify via KVL: V S = V 1 + V 2 + V 3 = 18 V + 30 V + 72 V = 120 V ( Confirmed ) V_S = V_1 + V_2 + V_3 = 18\text{ V} + 30\text{ V} + 72\text{ V} = 120\text{ V} \quad (\text{Confirmed}) V S ​ = V 1 ​ + V 2 ​ + V 3 ​ = 18 V + 30 V + 72 V = 120 V ( Confirmed )

Parallel Circuit Laws & Analysis

A parallel circuit provides two or more independent branches across a common voltage source. Most practical utilization systems in commercial buildings—such as convenience receptacles, luminaires, and equipment subpanels—are connected in parallel so each load receives full system voltage independently.

1. Voltage in Parallel

Because all parallel branches connect directly across the common supply nodes, the voltage drop across each branch is identical and equals the source voltage:

  • V T = V 1 = V 2 = V 3 = ⋯ = V n V_T = V_1 = V_2 = V_3 = \dots = V_n V T ​ = V 1 ​ = V 2 ​ = V 3 ​ = ⋯ = V n ​
  • 2. Kirchhoff's Current Law (KCL)

Kirchhoff's Current Law states that the algebraic sum of currents entering and exiting any electrical node (junction) must equal zero. Total current entering a junction equals total current leaving that junction:

∑ I i n = ∑ I o u t ⟹ I T = I 1 + I 2 + I 3 + ⋯ + I n \sum I_{in} = \sum I_{out} \implies I_T = I_1 + I_2 + I_3 + \dots + I_n ∑ I in ​ = ∑ I o u t ​ ⟹ I T ​ = I 1 ​ + I 2 ​ + I 3 ​ + ⋯ + I n ​

3. Total Resistance in Parallel

Connecting additional branches in parallel creates more conductive pathways for electrons, which increases total circuit current. Therefore, adding parallel branches always decreases total equivalent resistance ( R T R_T R T ​ ). Equivalent parallel resistance is always strictly less than the resistance of the smallest branch .

Three standard formulas calculate parallel equivalent resistance:

Reciprocal Formula (Any number of branches):

1 R T = 1 R 1 + 1 R 2 + 1 R 3 + ⋯ + 1 R n ⟹ R T = 1 1 R 1 + 1 R 2 + ⋯ + 1 R n \frac{1}{R_T} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots + \frac{1}{R_n} \implies R_T = \frac{1}{\frac{1}{R_1} + \frac{1}{R_2} + \dots + \frac{1}{R_n}} R T ​ 1 ​ = R 1 ​ 1 ​ + R 2 ​ 1 ​ + R 3 ​ 1 ​ + ⋯ + R n ​ 1 ​ ⟹ R T ​ = R 1 ​ 1 ​ + R 2 ​ 1 ​ + ⋯ + R n ​ 1 ​ 1 ​

Equal Resistors Rule:

If N N N identical resistors, each with resistance R R R , are in parallel:

R T = R N R_T = \frac{R}{N} R T ​ = N R ​

Product-Over-Sum Rule (Two branches only):

  • R T = R 1 × R 2 R 1 + R 2 R_T = \frac{R_1 \times R_2}{R_1 + R_2} R T ​ = R 1 ​ + R 2 ​ R 1 ​ × R 2 ​ ​
  • 4. Current Divider Rule (Two branches)

In a two-branch parallel network, total current divides inversely proportional to branch resistance:

I 1 = I T × ( R 2 R 1 + R 2 ) I 2 = I T × ( R 1 R 1 + R 2 ) I_1 = I_T \times \left(\frac{R_2}{R_1 + R_2}\right) \qquad I_2 = I_T \times \left(\frac{R_1}{R_1 + R_2}\right) I 1 ​ = I T ​ × ( R 1 ​ + R 2 ​ R 2 ​ ​ ) I 2 ​ = I T ​ × ( R 1 ​ + R 2 ​ R 1 ​ ​ )

For circuits with three or more branches, branch current is found directly via Ohm's Law:

I x = V T R x = I T × ( R T R x ) I_x = \frac{V_T}{R_x} = I_T \times \left(\frac{R_T}{R_x}\right) I x ​ = R x ​ V T ​ ​ = I T ​ × ( R x ​ R T ​ ​ )

Circuit Characteristic Series Circuit Parallel Circuit

Current Constant everywhere: I T = I 1 = I 2 = I n I_T = I_1 = I_2 = I_n I T ​ = I 1 ​ = I 2 ​ = I n ​ Additive: I T = I 1 + I 2 + ⋯ + I n I_T = I_1 + I_2 + \dots + I_n I T ​ = I 1 ​ + I 2 ​ + ⋯ + I n ​ (KCL)

Voltage Additive drops: V T = V 1 + V 2 + ⋯ + V n V_T = V_1 + V_2 + \dots + V_n V T ​ = V 1 ​ + V 2 ​ + ⋯ + V n ​ (KVL) Constant across branches: V T = V 1 = V 2 = V n V_T = V_1 = V_2 = V_n V T ​ = V 1 ​ = V 2 ​ = V n ​

Total Resistance Additive: R T = R 1 + R 2 + ⋯ + R n R_T = R_1 + R_2 + \dots + R_n R T ​ = R 1 ​ + R 2 ​ + ⋯ + R n ​ Reciprocal: R T = 1 / ∑ ( 1 / R n ) R_T = 1 / \sum (1/R_n) R T ​ = 1/ ∑ ( 1/ R n ​ )

Resistance Behavior R T > R_T > R T ​ > largest individual resistor R T < R_T < R T ​ < smallest individual branch resistor

  • Open-Circuit Effect Entire circuit de-energizes Only the open branch de-energizes
  • Combination (Series-Parallel) Circuit Reduction

Most real-world industrial control panels, communication circuits, and complex branch networks are combination circuits containing both series and parallel elements. Analyzing combination networks requires systematic equivalent-circuit reduction.

Step-by-Step Reduction Methodology

Inspect and Identify: Locate pure series pairs or pure parallel branches furthest from the supply source.

Collapse Branches: Replace identified groups with their calculated single equivalent resistance ( R e q 1 , R e q 2 R_{eq1}, R_{eq2} R e q 1 ​ , R e q 2 ​ , etc.).

Redraw the Schematic: Sketch the simplified circuit diagram at each reduction step to avoid topological errors.

Repeat: Continue collapsing series and parallel groups until the entire circuit is reduced to a single total equivalent resistance ( R T R_T R T ​ ).

Calculate Total Current: Apply Ohm's Law: I T = V S R T I_T = \frac{V_S}{R_T} I T ​ = R T ​ V S ​ ​ .

Back-Calculate: Trace backward through the simplified diagrams, applying KVL and KCL to solve for branch voltages and currents.

Worked Example: Combination Circuit Reduction

Problem: A 120 V 120\text{V} 120 V DC distribution circuit supplies a network where resistor R 1 = 10 Ω R_1 = 10\ \Omega R 1 ​ = 10 Ω is in series with a parallel bank consisting of R 2 = 30 Ω R_2 = 30\ \Omega R 2 ​ = 30 Ω and R 3 = 60 Ω R_3 = 60\ \Omega R 3 ​ = 60 Ω . This entire arrangement is in series with a final resistor R 4 = 10 Ω R_4 = 10\ \Omega R 4 ​ = 10 Ω . +---[ R1: 10 Ω ]---+---[ R2: 30 Ω ]---+---[ R4: 10 Ω ]---+

  • | | | |
  • (120V) +---[ R3: 60 Ω ]---+ |
  • | |
  • +--------------------------------------------------------+

Reduce the parallel bank ( R 2 ∥ R 3 R_2 \parallel R_3 R 2 ​ ∥ R 3 ​ ): R 2 , 3 = R 2 × R 3 R 2 + R 3 = 30 × 60 30 + 60 = 1 , 800 90 = 20 Ω R_{2,3} = \frac{R_2 \times R_3}{R_2 + R_3} = \frac{30 \times 60}{30 + 60} = \frac{1,800}{90} = 20\ \Omega R 2 , 3 ​ = R 2 ​ + R 3 ​ R 2 ​ × R 3 ​ ​ = 30 + 60 30 × 60 ​ = 90 1 , 800 ​ = 20 Ω

Calculate total series resistance ( R T R_T R T ​ ): R T = R 1 + R 2 , 3 + R 4 = 10 Ω + 20 Ω + 10 Ω = 40 Ω R_T = R_1 + R_{2,3} + R_4 = 10\ \Omega + 20\ \Omega + 10\ \Omega = 40\ \Omega R T ​ = R 1 ​ + R 2 , 3 ​ + R 4 ​ = 10 Ω + 20 Ω + 10 Ω = 40 Ω

Calculate total source current ( I T I_T I T ​ ): I T = V S R T = 120 V 40 Ω = 3.0 Amps I_T = \frac{V_S}{R_T} = \frac{120\text{ V}}{40\ \Omega} = 3.0\text{ Amps} I T ​ = R T ​ V S ​ ​ = 40 Ω 120 V ​ = 3.0 Amps

Calculate series voltage drops:

Across R 1 R_1 R 1 ​ : V 1 = I T × R 1 = 3.0 A × 10 Ω = 30 V V_1 = I_T \times R_1 = 3.0\text{ A} \times 10\ \Omega = 30\text{ V} V 1 ​ = I T ​ × R 1 ​ = 3.0 A × 10 Ω = 30 V

Across R 4 R_4 R 4 ​ : V 4 = I T × R 4 = 3.0 A × 10 Ω = 30 V V_4 = I_T \times R_4 = 3.0\text{ A} \times 10\ \Omega = 30\text{ V} V 4 ​ = I T ​ × R 4 ​ = 3.0 A × 10 Ω = 30 V

Calculate parallel bank voltage ( V p a r a l l e l V_{parallel} V p a r a ll e l ​ ): V p a r a l l e l = V S − ( V 1 + V 4 ) = 120 V − ( 30 V + 30 V ) = 60 V V_{parallel} = V_S - (V_1 + V_4) = 120\text{ V} - (30\text{ V} + 30\text{ V}) = 60\text{ V} V p a r a ll e l ​ = V S ​ − ( V 1 ​ + V 4 ​ ) = 120 V − ( 30 V + 30 V ) = 60 V (Verification: V p a r a l l e l = I T × R 2 , 3 = 3.0 A × 20 Ω = 60 V V_{parallel} = I_T \times R_{2,3} = 3.0\text{ A} \times 20\ \Omega = 60\text{ V} V p a r a ll e l ​ = I T ​ × R 2 , 3 ​ = 3.0 A × 20 Ω = 60 V )

Calculate individual branch currents in the parallel bank:

Through R 2 R_2 R 2 ​ : I 2 = V p a r a l l e l R 2 = 60 V 30 Ω = 2.0 Amps I_2 = \frac{V_{parallel}}{R_2} = \frac{60\text{ V}}{30\ \Omega} = 2.0\text{ Amps} I 2 ​ = R 2 ​ V p a r a ll e l ​ ​ = 30 Ω 60 V ​ = 2.0 Amps

Through R 3 R_3 R 3 ​ : I 3 = V p a r a l l e l R 3 = 60 V 60 Ω = 1.0 Amp I_3 = \frac{V_{parallel}}{R_3} = \frac{60\text{ V}}{60\ \Omega} = 1.0\text{ Amp} I 3 ​ = R 3 ​ V p a r a ll e l ​ ​ = 60 Ω 60 V ​ = 1.0 Amp

Verify KCL at junction: I T = I 2 + I 3 = 2.0 A + 1.0 A = 3.0 A ( Confirmed ) I_T = I_2 + I_3 = 2.0\text{ A} + 1.0\text{ A} = 3.0\text{ A} \quad (\text{Confirmed}) I T ​ = I 2 ​ + I 3 ​ = 2.0 A + 1.0 A = 3.0 A ( Confirmed )

Bridge Circuits (Wheatstone Bridge)

A Wheatstone bridge is a four-arm resistive network ( R 1 , R 2 , R 3 , R 4 R_1, R_2, R_3, R_4 R 1 ​ , R 2 ​ , R 3 ​ , R 4 ​ ) connected in a diamond topology with an excitation voltage V S V_S V S ​ applied across nodes A A A and B B B , and a sensitive detector (galvanometer or differential amplifier) connected across intermediate nodes C C C and D D D . Node A (+)

  • / \
  • [ R1 ] [ R2 ]
  • / \
  • Node C --- (G) --- Node D
  • \ /
  • [ R3 ] [ R4 ]
  • \ /
  • Node B (-)

The bridge achieves a balanced condition when the electrical potential at Node C C C equals the electrical potential at Node D D D , resulting in zero potential difference ( V C D = 0 V V_{CD} = 0\text{ V} V C D ​ = 0 V ) and zero current through the detector:

R 1 R 3 = R 2 R 4 ⟹ R 1 × R 4 = R 2 × R 3 \frac{R_1}{R_3} = \frac{R_2}{R_4} \implies R_1 \times R_4 = R_2 \times R_3 R 3 ​ R 1 ​ ​ = R 4 ​ R 2 ​ ​ ⟹ R 1 ​ × R 4 ​ = R 2 ​ × R 3 ​

If three resistor values are known precisely, the fourth unknown resistance is determined with high accuracy:

R 4 = R 2 × R 3 R 1 R_4 = \frac{R_2 \times R_3}{R_1} R 4 ​ = R 1 ​ R 2 ​ × R 3 ​ ​

In industrial commercial instrumentation, Wheatstone bridges form the core sensing circuitry in resistance temperature detectors (RTDs) (e.g., Pt100 sensors), piezoresistive pressure transducers, and structural strain gauges.

Circuit Troubleshooting: Open vs. Short Circuit Symptoms

Diagnosing field faults requires recognizing the exact symptoms that open circuits and short circuits produce in series versus parallel arrangements:

Fault Condition Series Circuit Behavior Parallel Circuit Behavior

Open Circuit Total current drops to zero ( I T = 0 I_T = 0 I T ​ = 0 ). Zero voltage drop appears across all intact resistors ( V R = 0 V_R = 0 V R ​ = 0 ). Full source voltage appears directly across the open break. The affected branch drops to zero current ( I b r a n c h = 0 I_{branch} = 0 I b r an c h ​ = 0 ). Remaining parallel branches continue operating normally. Total current drops ( I T ↓ I_T \downarrow I T ​ ↓ ), and equivalent circuit resistance rises ( R T ↑ R_T \uparrow R T ​ ↑ ).

Short Circuit Resistance of the shorted component drops to zero ( R s h o r t → 0 R_{short} \to 0 R s h or t ​ → 0 ). Total resistance decreases ( R T ↓ R_T \downarrow R T ​ ↓ ), increasing circuit current ( I T ↑ I_T \uparrow I T ​ ↑ ). Remaining components experience higher voltage drops and elevated thermal stress. The short bypasses all parallel branches. Total resistance collapses toward zero ( R T → 0 R_T \to 0 R T ​ → 0 ). Massive fault current flows until the upstream overcurrent protective device (fuse or breaker) clears the fault.

Loading diagram... Combination Series-Parallel Circuit Reduction Flow