Study guide

7.3 Removing and Installing Bearings: Fits, Heating, and Mounting

NCCER Industrial Maintenance Mechanic Exam

Track your progress as you read

Finished sections get a check mark.

1 The NCCER Industrial Maintenance Mechanic Assessment

1.1 The IMM Journey-Level Credential and Assessment Specification 1.2 The Nine Content Domains: Item Counts and a Study Plan

2 Industrial Maintenance Mechanic Fundamentals

2.1 Safety Programs, PPE, and Hazard Communication 2.2 Hazardous Energy Control: Lockout/Tagout and Confined Space Entry 2.3 Tools of the Trade: Hand and Power Tools 2.4 Oxyfuel Cutting: Equipment, Safe Setup, and Cutting Practice 2.5 Ferrous Metal Piping Practices: Cutting, Threading, and Joining

3 Rigging and Mobile Equipment

3.1 Slings, Rigging Hardware, and Inspection Criteria 3.2 Load Weight, Center of Gravity, Sling Angle, and Hand Signals 3.3 Mobile and Support Equipment: Forklifts, Aerial Lifts, and Mobile Cranes

4 Craft Mathematics, Layout, and Precision Measurement

4.1 Craft-Related Mathematics: Fractions, Units, Area, and Volume 4.2 Advanced Trade Math: Right Triangles, Trigonometry, and Pipe Offsets 4.3 Basic Layout: Squaring, Leveling, and Transferring Elevations 4.4 Precision Measuring Tools: Micrometers, Verniers, and Dial Indicators 4.5 Gauges, Tolerances and Fits, and Torque Measurement

5 Construction Drawings and Blueprint Reading

5.1 Reading Construction Drawings: Views, Lines, Scales, and the Title Block 5.2 Orthographic, Isometric, Arrangement, and Foundation Drawings 5.3 Advanced Blueprint Reading: P&IDs, Instrument Tags, and Welding Symbols

6 Valves, Packing, and Mechanical Seals

6.1 Valve Types and Service Selection 6.2 Valve Construction, Markings, Pressure Classes, and Actuators 6.3 Removing and Installing Valves: Flange Bolting and Torque Sequence 6.4 Valve Maintenance: Packing, Stuffing Boxes, Gaskets, and O-Rings 6.5 Hydrostatic and Pneumatic Testing of Piping and Equipment 6.6 Mechanical Seals: Components, Types, and Installation

7 Bearings, Lubrication, and Couplings

7.1 Bearing Types, Designations, and Selection 7.2 Bearing Lubrication, Handling, and Failure Analysis 7.3 Removing and Installing Bearings: Fits, Heating, and Mounting 7.4 Couplings: Types, Selection, and Installation

8 Pumps, Baseplates, and Mechanical Drives

8.1 Pumps and Drivers: Centrifugal and Positive Displacement 8.2 Setting Baseplates and Soleplates: Leveling, Anchoring, and Grouting 8.3 Prealignment: Soft Foot, Runout, Pipe Strain, and Shims 8.4 Installing Belt and Chain Drives

9 Shaft Alignment: Conventional, Reverse, and Laser

9.1 Conventional Rim-and-Face Dial Indicator Alignment 9.2 Reverse Dial Indicator Alignment 9.3 Laser Shaft Alignment Systems

10 Maintenance Troubleshooting: Method, Pumps, and Gearboxes

10.1 Systematic Troubleshooting and Root Cause Analysis 10.2 Troubleshooting and Repairing Pumps 10.3 Troubleshooting and Repairing Gearboxes

11 Steam Systems, Boilers, and Process Vessels

11.1 Low-Pressure Steam Systems, Traps, and Condensate Return 11.2 High-Pressure Steam Generation and Boiler Auxiliaries 11.3 Distillation Towers, Vessels, and Internals

12 Compressors and Pneumatic Systems

12.1 Air Compressor Types, Operation, and Maintenance 12.2 Compressed Air Treatment, Storage, and Distribution 12.3 FRL Units, Pneumatic Valves, Actuators, and Speed Control

7.3 Removing and Installing Bearings: Fits, Heating, and Mounting

Key Takeaways Explain This Topic AI

Mounting force must always be applied to the ring being fitted, never transmitted through the balls or rollers.

Induction heaters and clean oil baths are the accepted heating methods, and bearing temperature should not exceed roughly 250 degrees Fahrenheit for standard bearings.

An open flame must never be used to heat a bearing, because it destroys the heat treatment and the lubricant.

Bearing pullers must grip the ring that is being removed from its interference fit, so an inner ring puller grips the inner ring.

Shaft and housing dimensions must be measured before mounting, because an out-of-tolerance seat, not the bearing, causes most repeat failures.

Last updated: September 2026

Measure first, mount second

A new bearing does not fix a worn shaft. Before anything is removed, and again before anything is installed, measure:

Dimension Tool Why

Shaft seat diameter Outside micrometer, at several points and angles Confirms interference fit; catches taper and out-of-round

Housing bore Telescoping gauge and micrometer, or inside micrometer Confirms clearance fit; catches a bell-mouthed bore

Shaft shoulder squareness and radius Square and radius gauge A shoulder that is not square cocks the bearing; too large a fillet radius prevents the ring from seating

Shaft runout Dial indicator on V-blocks or in place A bent shaft will destroy any bearing

Recall the rule from Chapter 4: the ring that rotates relative to the load direction gets the interference fit. On a normal motor or pump this is the inner ring on the shaft, with a clearance fit for the outer ring in the housing. On a machine where the load rotates with the shaft — a rotating housing, an eccentric load — the relationship reverses.

If the shaft seat is undersized, the fix is a repair sleeve, metal spray and regrind, or shaft replacement. Knurling or center-punching a worn shaft to "raise" it is not a repair; it creates high points that collapse under load and guarantees a fretted, loose bearing within weeks.

Removing a bearing

Support the shaft or assembly so it does not drop when the bearing releases.

Pull on the ring that is tight. An inner ring pressed onto the shaft must be pulled by the inner ring . Gripping the outer ring and pulling forces the load through the balls or rollers and brinells the races — which does not matter for a bearing you are scrapping, but does matter when you are removing a bearing you intend to reuse or inspect, and it can shatter a ring and throw fragments.

Choose the tool for the access : two- or three-jaw puller, bearing separator (knife-edge splitter) behind the inner ring, hydraulic puller for large interference, or a press with the assembly supported under the ring being removed.

Heat can help. An induction heater or a bearing heater applied to the outer ring of a housed bearing expands it off its seat. Never apply an open flame.

Protect yourself. Bearing removal stores energy in the puller. Use a shield or a blanket, keep the puller square, and never stand in line with the jaws.

Keep the failed bearing for analysis. The wear pattern is the diagnosis, and Chapter 10 depends on it.

Mounting: cold methods

For light interference on smaller bearings:

Use a bearing fitting tool — a sleeve or driver that contacts only the ring being fitted — with a soft-face hammer, or press the bearing with an arbor press through the same kind of sleeve.

The mounting force must never pass through the rolling elements. Driving on the outer ring to seat an inner ring on the shaft puts the entire load through the balls and dents both raceways. Those dents are true brinelling, and the bearing will be noisy from the first hour.

Drive square . A cocked bearing binds on the shaft and is then very difficult to move either direction.

Mounting: heat methods

For medium and heavy interference fits, expand the inner ring instead of forcing it:

  • Method Notes
  • Induction heater Preferred; fast, clean, controlled, and demagnetizes on completion

Clean oil bath with thermostat Traditional and effective; the bearing must sit on a screen, never on the bottom of the tank

Electric hot plate or oven Acceptable with good temperature control

Open flame Never. Uncontrolled, overheats locally, destroys heat treatment and lubricant, and contaminates the bearing

The working rule is to heat the bearing roughly 150°F above the shaft temperature , which is normally enough for the ring to slide on freely, and to never exceed the manufacturer's limit of about 250°F (120°C) for standard bearings. Above that limit the hardened rings begin to temper and lose hardness permanently, and sealed or shielded bearings lose their grease charge.

Slide the hot bearing onto the shaft in one continuous motion until it seats against the shoulder, then hold it against the shoulder while it cools , because the ring contracts axially as well as radially and will pull away from the shoulder if it is not held.

A sealed or shielded bearing must never be put in an oil bath, because the oil contaminates the grease charge. Use an induction heater with the bearing's temperature monitored.

After mounting

Confirm the bearing is fully seated against the shoulder with a feeler gauge all the way around.

Check for free rotation : a correctly mounted bearing turns smoothly with no notchiness and no drag.

Verify the axial arrangement — one located end, one floating end. The floating bearing must actually be free to move in the housing.

Install locknuts and lockwashers correctly: bend the tab into a slot, not against the face, and use the correct spanner rather than a punch and hammer.

Lubricate before starting , to the correct fill, and set the relubrication interval in the maintenance system.