Study guide
9.1 Conventional Rim-and-Face Dial Indicator Alignment
NCCER Industrial Maintenance Mechanic Exam
Track your progress as you read
Finished sections get a check mark.
1 The NCCER Industrial Maintenance Mechanic Assessment
1.1 The IMM Journey-Level Credential and Assessment Specification 1.2 The Nine Content Domains: Item Counts and a Study Plan
2 Industrial Maintenance Mechanic Fundamentals
2.1 Safety Programs, PPE, and Hazard Communication 2.2 Hazardous Energy Control: Lockout/Tagout and Confined Space Entry 2.3 Tools of the Trade: Hand and Power Tools 2.4 Oxyfuel Cutting: Equipment, Safe Setup, and Cutting Practice 2.5 Ferrous Metal Piping Practices: Cutting, Threading, and Joining
3 Rigging and Mobile Equipment
3.1 Slings, Rigging Hardware, and Inspection Criteria 3.2 Load Weight, Center of Gravity, Sling Angle, and Hand Signals 3.3 Mobile and Support Equipment: Forklifts, Aerial Lifts, and Mobile Cranes
4 Craft Mathematics, Layout, and Precision Measurement
4.1 Craft-Related Mathematics: Fractions, Units, Area, and Volume 4.2 Advanced Trade Math: Right Triangles, Trigonometry, and Pipe Offsets 4.3 Basic Layout: Squaring, Leveling, and Transferring Elevations 4.4 Precision Measuring Tools: Micrometers, Verniers, and Dial Indicators 4.5 Gauges, Tolerances and Fits, and Torque Measurement
5 Construction Drawings and Blueprint Reading
5.1 Reading Construction Drawings: Views, Lines, Scales, and the Title Block 5.2 Orthographic, Isometric, Arrangement, and Foundation Drawings 5.3 Advanced Blueprint Reading: P&IDs, Instrument Tags, and Welding Symbols
6 Valves, Packing, and Mechanical Seals
6.1 Valve Types and Service Selection 6.2 Valve Construction, Markings, Pressure Classes, and Actuators 6.3 Removing and Installing Valves: Flange Bolting and Torque Sequence 6.4 Valve Maintenance: Packing, Stuffing Boxes, Gaskets, and O-Rings 6.5 Hydrostatic and Pneumatic Testing of Piping and Equipment 6.6 Mechanical Seals: Components, Types, and Installation
7 Bearings, Lubrication, and Couplings
7.1 Bearing Types, Designations, and Selection 7.2 Bearing Lubrication, Handling, and Failure Analysis 7.3 Removing and Installing Bearings: Fits, Heating, and Mounting 7.4 Couplings: Types, Selection, and Installation
8 Pumps, Baseplates, and Mechanical Drives
8.1 Pumps and Drivers: Centrifugal and Positive Displacement 8.2 Setting Baseplates and Soleplates: Leveling, Anchoring, and Grouting 8.3 Prealignment: Soft Foot, Runout, Pipe Strain, and Shims 8.4 Installing Belt and Chain Drives
9 Shaft Alignment: Conventional, Reverse, and Laser
9.1 Conventional Rim-and-Face Dial Indicator Alignment 9.2 Reverse Dial Indicator Alignment 9.3 Laser Shaft Alignment Systems
10 Maintenance Troubleshooting: Method, Pumps, and Gearboxes
10.1 Systematic Troubleshooting and Root Cause Analysis 10.2 Troubleshooting and Repairing Pumps 10.3 Troubleshooting and Repairing Gearboxes
11 Steam Systems, Boilers, and Process Vessels
11.1 Low-Pressure Steam Systems, Traps, and Condensate Return 11.2 High-Pressure Steam Generation and Boiler Auxiliaries 11.3 Distillation Towers, Vessels, and Internals
12 Compressors and Pneumatic Systems
12.1 Air Compressor Types, Operation, and Maintenance 12.2 Compressed Air Treatment, Storage, and Distribution 12.3 FRL Units, Pneumatic Valves, Actuators, and Speed Control
9.1 Conventional Rim-and-Face Dial Indicator Alignment
Key Takeaways Explain This Topic AI
Misalignment has two components in each plane: offset, where the centerlines are parallel but displaced, and angularity, where the centerlines converge.
A rim reading is twice the actual centerline offset, while a face reading measures angularity across the diameter the indicator sweeps.
Both shafts are rotated together so that coupling hub runout and shaft bow cancel out of the readings.
The validity rule for a full sweep is that the top reading plus the bottom reading must equal the left reading plus the right reading.
Bracket sag must be measured on a mandrel and subtracted from the readings, because the indicator bracket droops under its own weight.
Last updated: September 2026
Why alignment is worth a third of a domain
Domain 8, Maintenance and Troubleshooting , contributes 15 of 115 items and references five modules — 32306 Conventional Alignment , 32404 Reverse Alignment , 32405 Laser Alignment , 32407 Troubleshooting and Repairing Pumps , and 32408 Troubleshooting and Repairing Gearboxes . Three of those five are alignment, which is why this guide devotes a full chapter to it.
Misalignment is the leading mechanical cause of premature bearing and seal failure in rotating equipment. A misaligned coupling applies a cyclic bending load to both shafts on every revolution.
The geometry
Shaft misalignment is described in two planes — vertical and horizontal — and in each plane it has two components :
Offset (parallel) misalignment : the shaft centerlines are parallel but displaced from one another.
Angular misalignment : the shaft centerlines are not parallel; they converge at an angle.
Real machines have both, in both planes, so a complete alignment is four numbers : vertical offset, vertical angularity, horizontal offset, horizontal angularity.
The classic vibration signature of misalignment is elevated vibration at twice running speed , with unusually high axial vibration — a distinguishing feature, because unbalance produces high radial vibration at one times running speed and relatively little axial.
Rim and face: what each indicator measures
In the rim-and-face method, a bracket is clamped to one shaft or hub and carries two indicators reading the opposite hub:
The rim indicator rides the outside diameter of the opposite hub. As the shafts rotate, it registers the offset between the centerlines — but it registers it twice , because the plunger is pushed in on the high side and released on the low side. Actual offset equals half the rim total indicator reading.
The face indicator rides the face of the opposite hub. Its reading is the difference in axial gap from one side to the other, which is angularity expressed across the diameter the indicator sweeps.
Setting up
Lock out and verify both machines.
Complete every prealignment check from Chapter 8: soft foot, runout, pipe strain, and thermal growth targets.
Rotate both shafts together. This is the rule that makes the method work: if only one shaft is turned, the coupling hub runout and any shaft bow on the other machine go straight into the readings. Rotating both together cancels them.
Mark both hubs at 12, 3, 6, and 9 o'clock and take readings at those four positions, always rotating in the same direction as normal machine rotation and always returning to 12 o'clock to confirm the indicators re-zero.
Zero both indicators at the 12 o'clock position.
Bracket sag
An indicator bracket is a cantilever. It droops under the weight of the indicators, and the droop reverses between the top and bottom positions, so it appears in the readings as a pure vertical offset that does not exist.
Measure it. Clamp the bracket on a rigid pipe or mandrel of the same span, zero the indicator at 12 o'clock, rotate to 6 o'clock, and read. That value — always negative — is the sag. Subtract it from the bottom rim reading before calculating anything.
Sag of 0.005 inch or more is common with a long bracket. Ignoring it can put the correction in the wrong direction entirely.
Validating the readings
Before you calculate anything, check the arithmetic of the sweep:
Top + Bottom = Left + Right
A full 360-degree sweep returns the indicator to its starting point, so the two opposing pairs must sum to the same value. If they do not, something moved: the bracket slipped, a bolt is loose, the shaft floated axially, or the indicator stuck. Re-take the readings rather than calculating from invalid data. This validity rule is the single most useful quality check in the whole procedure.
Calculating the moves
Corrections follow from similar triangles. With rim and face readings from a complete sweep:
Angular correction (from the face reading). The face reading is the gap difference across the indicator sweep diameter. The shim change needed at a given foot is: Shim change = Face reading × Distance from coupling to that foot Diameter swept by the face indicator \text{Shim change} = \frac{\text{Face reading} \times \text{Distance from coupling to that foot}}{\text{Diameter swept by the face indicator}} Shim change = Diameter swept by the face indicator Face reading × Distance from coupling to that foot
Offset correction (from the rim reading). Half the rim TIR is the actual offset, and that amount is added to or subtracted from both feet equally .
The two corrections are then combined: the front foot and back foot each get the offset correction plus their own angular correction, and the result is the total shim change at each foot.
Worked example. Face reading TIR is 0.010 inch on a 6-inch diameter sweep. The front foot is 12 inches from the coupling and the back foot is 30 inches.
- Front foot angular change: 0.010 × 12 ÷ 6 = 0.020 inch
- Back foot angular change: 0.010 × 30 ÷ 6 = 0.050 inch
If the rim TIR is 0.014 inch, the offset is 0.007 inch, applied equally at both feet. The signs — add or remove shim — follow from which side the high readings fall on, and a sketch of the actual machine drawn to the side is worth more than any memorized sign convention.
Horizontal moves and final checks
Vertical corrections are made with shims . Horizontal corrections are made by moving the machine sideways , which is what jackscrews on the baseplate are for. Driving a machine sideways with a sledgehammer both overshoots and damages the feet.
Work vertical first, then horizontal , and re-read after every move. When the readings are inside tolerance:
Torque all hold-down bolts to specification in a consistent pattern.
Re-check the readings with the bolts tight. A correct set of numbers with loose bolts means nothing.
Re-check soft foot, because shim changes can introduce it.
Record the final readings, shim values at each foot, and the thermal targets used.
Tolerances
Alignment tolerance tightens as speed rises, because the same offset produces a higher cyclic velocity at the coupling. Widely used industry guidance, expressed in thousandths of an inch (mils):
- Speed Offset, excellent Offset, acceptable Angularity, acceptable
- 600 rpm 5.0 mils 9.0 mils 1.0 mil/in
- 1,200 rpm 2.5 mils 4.0 mils 0.5 mil/in
- 1,800 rpm 2.0 mils 3.0 mils 0.3 mil/in
- 3,600 rpm 1.0 mil 1.5 mils 0.2 mil/in
Where the equipment manufacturer publishes a tolerance, that value governs over any general table.