Study guide

1.3 Topographic Indices, Asphericity & Cone Localization

ABO-NCLE Advanced Contact Lens Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Corneal Topography, Tomography & Anterior Segment Imaging

1.1 Placido-Based Corneal Topography: Axial, Tangential & Elevation Maps 1.2 Corneal Tomography & Scheimpflug Imaging: Anterior/Posterior Elevation & Pachymetry 1.3 Topographic Indices, Asphericity & Cone Localization

2 Chapter 2: Complex Corneal Conditions & Surgical Alterations

2.1 Keratoconus, Pellucid Marginal Degeneration & Keratoglobus 2.2 Post-Keratoplasty (PKP/DALK) & Corneal Cross-Linking (CXL) 2.3 Post-Refractive Ectasia & Post-Refractive Surgery Corneas

3 Chapter 3: Prefit Ocular Surface Evaluation & Candidacy Assessment

3.1 Slit-Lamp Biomicroscopy & Ocular Surface Vital Staining 3.2 Tear Film Dynamics, Dry Eye & Severe Ocular Surface Disease 3.3 Patient History, Visual Needs Analysis & Specialty Lens Selection Strategy

4 Chapter 4: Scleral Lens Design Fundamentals & Sagittal Depth

4.1 Scleral Anatomy, Terminology & Sagittal Depth Principles 4.2 Central Corneal & Limbal Vault Clearance Optimization 4.3 Landing Zone Toricity, Quadrant-Specific Haptics & Edge Profiles

5 Chapter 5: Corneal RGP & Specialty Toric Designs for Irregular Corneas

5.1 Corneal RGP Fitting Philosophies: Apical Clearance vs Bearing vs Three-Point Touch 5.2 Bitoric & High-Toric RGP Calculations: SPE vs CPE & Induced Cylinder 5.3 Lens Materials, Hyper-Dk Polymers & Surface Coatings

6 Chapter 6: Hybrid & Piggyback Contact Lens Systems

6.1 Hybrid Lens Architecture: Rigid Center & Soft Hydrophilic Skirt Fitting 6.2 Hybrid Parameter Selection, Movement & Tear Exchange Optimization 6.3 Piggyback Systems: Carrier Selection, Power Calculations & Hypoxia Prevention

7 Chapter 7: Orthokeratology & Custom Prosthetic Lenses

7.1 Orthokeratology Reverse-Geometry Principles, Jessen Formula & Topographic Patterns 7.2 Prosthetic, Occlusive & Custom Soft Specialty Lenses for Irregular Corneas

8 Chapter 8: Specialty Lens Delivery, Application & Removal Techniques

8.1 Scleral Lens Application Protocols, Plungers & Bubble Prevention 8.2 Scleral, Hybrid & RGP Removal Techniques & Emergency Extraction 8.3 Patient Handling Training, Hygiene & Lens Inspection at Dispense

9 Chapter 9: Filling Solutions, Chemical Disinfection & Wearing Schedules

9.1 Preservative-Free Scleral Reservoir Filling Solutions & Fluid Dynamics 9.2 Disinfection Regimens, Conditioning Systems, Hydra-PEG Care & Adaptation Schedules

10 Chapter 10: Slit-Lamp Fit Evaluation & Optical Troubleshooting

10.1 Settling Time Dynamics & Slit-Lamp Evaluation of Vault Clearance 10.2 Midday Fogging, Tear Reservoir Debris & Lens Surface Wettability 10.3 Over-Refraction, Lenticular Astigmatism & Lens Flexure vs Warpage

11 Chapter 11: In-Office & Laboratory Specialty Lens Modifications

11.1 In-Office Corneal RGP Modifications: Edge Blending, Polishing & Power Changes 11.2 Scleral Parameter Adjustments: Sagittal Depth, Landing Zones & Micro-Vaults 11.3 Ortho-K & Hybrid Fit Problem Solving and Parameter Modifications

12 Chapter 12: Acute Complications, Corneal Pathology & Emergency Triage

12.1 Corneal Hypoxia, Neovascularization & Graft Rejection Recognition 12.2 Mechanical Staining Patterns, Dimple Veiling, Impingement & Conjunctival Prolapse 12.3 Infectious Keratitis, Infiltrative Events & Acute Triage Protocols

13 Chapter 13: Clinical Infection Control, Regulatory Standards & Practice Management

13.1 Diagnostic Fitting Set Decontamination, OSHA & Clinical Infection Control 13.2 FCLCA, Contact Lens Rule, FDA Regulatory Standards & SOAP Documentation

1.3 Topographic Indices, Asphericity & Cone Localization

Key Takeaways Explain This Topic AI

Simulated keratometry summarizes central orthogonal meridians and can miss the steepest point in decentered or irregular ectasia.

The historical Rabinowitz–McDonnell I–S and central-power thresholds are screening rules derived from particular Placido methods; exceeding one raises suspicion but does not independently establish keratoconus.

Q-value describes asphericity relative to the fitted model, but lens geometry is selected from the total corneal or scleral shape, visual goals, handling needs, and an on-eye assessment.

Nipple, oval, and globus are useful descriptive cone patterns, not rigid diameter cutoffs that automatically determine one lens modality.

Corneal GP, hybrid, piggyback, custom soft, and scleral options can overlap; select and verify the least burdensome modality that provides acceptable vision, physiology, stability, and handling.

Last updated: September 2026

1.3 Topographic Indices, Asphericity & Cone Localization

Accurate interpretation of corneal topography requires moving beyond subjective visual color inspection to objective quantitative indices. For contact lens practitioners, numerical indices support pattern recognition, while asphericity and cone description help form a fitting hypothesis that must be tested on eye.

Quantitative Topographic Indices

Modern topographers synthesize thousands of data points into standardized numerical indices designed to assist in screening, longitudinal monitoring, and lens selection.

Simulated Keratometry (SimK)

Simulated Keratometry emulates conventional manual keratometry by sampling curvature along two orthogonal meridians separated by 90 degrees at the 3.0 mm optical zone :

SimK1 (Flat K): The flattest meridian at the 3.0 mm zone.

SimK2 (Steep K): The meridian 90 degrees away from SimK1.

Δ K \Delta K Δ K (Corneal Astigmatism): SimK2 − SimK1 \text{SimK2} - \text{SimK1} SimK2 − SimK1 .

The SimK Trap in Ectasia: Because keratoconic cones are frequently decentered 3.0 mm to 5.0 mm away from the corneal center, the 3.0 mm SimK ring captures only the shoulder of the cone. Review the local curvature display, including the reported maximum value and its location, while recognizing that Kmax is device-dependent and does not alone establish diagnosis or lens geometry.

Optical Regularity and Asymmetry Indices

Surface Regularity Index (SRI): Measures local optical regularity across 256 points within the central 4.5 mm pupillary aperture. In a healthy eye, SRI approaches zero ( < 0.20 < 0.20 < 0.20 ). Elevated SRI values correlate directly with loss of spectacle best-corrected visual acuity (BCVA) caused by irregular astigmatism and higher-order optical aberrations (such as coma and trefoil).

Surface Asymmetry Index (SAI): Compares corneal power between 128 pairs of points situated 180 degrees apart along identical radial distances. High SAI values ( > 0.50 > 0.50 > 0.50 ) indicate pronounced asymmetry across the visual axis, characteristically observed in keratoconus, decentered refractive surgery ablations, and tilted penetrating keratoplasty (PKP) donor buttons.

Keratoconus Prediction Index (KPI): A multivariate discriminant index combining eight distinct topographic indices (including SimK1, SimK2, SAI, SRI, and differential sector powers). A KPI value > 0.23 > 0.23 > 0.23 indicates a high statistical probability of keratoconus.

The Rabinowitz-McDonnell Diagnostic Criteria

In 1989, Dr. Yaron Rabinowitz and Dr. Peter McDonnell established the clinical benchmark criteria for identifying keratoconus based on Placido topography.

The Inferior-Superior (I-S) Value

Keratoconus most commonly develops in the inferior corneal hemisphere. The I-S value quantifies vertical asymmetry by evaluating five points located 3.0 mm inferior to the center (at 210°, 240°, 270°, 300°, and 330°) and subtracting the average of five corresponding points located 3.0 mm superior to the center (at 30°, 60°, 90°, 120°, and 150°): I − S = K ˉ Inferior − K ˉ Superior I-S = \bar{K}_{\text{Inferior}} - \bar{K}_{\text{Superior}} I − S = K ˉ Inferior ​ − K ˉ Superior ​

Diagnostic Decision Rules

Historical Placido-screening publications described I–S and central-power cutoffs, with larger asymmetry or steeper values increasing suspicion. Treat these as method-specific screening aids. Modern assessment also considers scan quality, repeatability, anterior and posterior elevation, pachymetric progression, epithelial mapping, refraction, examination, and documented progression.

Corneal Asphericity: Q-Value, Eccentricity, and Shape Factor

The human cornea is not spherical; it is an aspheric surface that changes in curvature from the center toward the limbus. Mathematically, the corneal cross-section is modeled as a conic section governed by three interrelated parameters: p = 1 − e 2 = 1 + Q ⟹ Q = − e 2 p = 1 - e^2 = 1 + Q \implies Q = -e^2 p = 1 − e 2 = 1 + Q ⟹ Q = − e 2

Shape Factor ( p p p ): Defines overall conic shape ( p = 1 p = 1 p = 1 is spherical, p < 1 p < 1 p < 1 is prolate, p > 1 p > 1 p > 1 is oblate).

Eccentricity ( e e e ): Quantifies the rate of radial flattening ( e = 0 e = 0 e = 0 is spherical; normal cornea e ≈ 0.40 e \approx 0.40 e ≈ 0.40 to 0.60 0.60 0.60 ).

Asphericity ( Q Q Q -Value): Measures deviation from a true sphere in dioptric terms.

Prolate vs. Oblate Geometries PROLATE (Normal Cornea): OBLATE (Post-Myopic LASIK / PRK / Ortho-K):

  • | |
  • / \ (Steep Center) \ / (Flat Center)
  • / \ (Flattens Peripherally) \ / (Steepens Peripherally)
  • | | | |
  • Q < 0 (avg -0.26) Q > 0

Normal Prolate Cornea ( Q < 0 Q < 0 Q < 0 , average Q ≈ − 0.26 Q \approx -0.26 Q ≈ − 0.26 , range − 0.10 -0.10 − 0.10 to − 0.35 -0.35 − 0.35 ): The central cornea is steepest and continuously flattens toward the periphery. In keratoconus, the cornea becomes hyperprolate ( Q < − 0.80 Q < -0.80 Q < − 0.80 to − 1.50 -1.50 − 1.50 ) , featuring an extraordinarily steep apex and dramatic peripheral flattening.

Oblate Cornea ( Q > 0 Q > 0 Q > 0 ): The central cornea is flat, while the mid-periphery and periphery steepen. Oblate geometries are created iatrogenically by myopic laser ablation (LASIK, PRK), radial keratotomy (RK), or orthokeratology (Ortho-K).

Contact Lens Design: Standard vs. Reverse Geometry

Standard Alignment Lenses: Designed for prolate corneas; the base curve parallels the central cornea, and peripheral curves flatten progressively to provide edge lift.

The Oblate Fitting Disaster: If a standard prolate lens is placed on an oblate post-LASIK cornea, the lens will rest heavily on the steeper mid-periphery while bridging far above the flat center. This creates massive central bubble entrapment, mid-peripheral bearing, and peripheral lens seal-off .

Reverse Geometry Lenses: An oblate cornea may benefit from a reverse-geometry design in which a steeper secondary zone helps align with the midperipheral knee. The exact relationship is design-specific. This allows the lens to clear the steep mid-periphery and align evenly over the flat central ablation zone.

Cone Morphological Classification

Keratoconic ectasias are classified clinically into three primary morphological profiles based on the geographic size, location, and boundaries of the cone:

1. Nipple Cones

Dimensions: Small diameter, ≤ 5.0 mm \le 5.0\ \text{mm} ≤ 5.0 mm (often 3.0 mm to 4.0 mm).

Location: Central or paracentral, typically displaced slightly inferonasal or inferotemporal.

Topographic Appearance: A round, circumscribed island of steep curvature surrounded by 360 degrees of normal, flat cornea. There is a high dioptric gradient between the cone and the surrounding tissue.

Contact Lens Selection: Successfully managed with small-diameter corneal RGPs (8.5 mm to 9.2 mm) using a multi-curve or aspheric design. The small diameter allows the lens to center directly over the compact cone without rocking. If lid forces cause decentration, an intralimbal design (10.5 mm to 11.2 mm) provides enhanced stability.

2. Oval Cones

Dimensions: Medium diameter, 5.0 mm 5.0\ \text{mm} 5.0 mm to 6.0 mm 6.0\ \text{mm} 6.0 mm .

Location: Markedly decentered inferotemporally, frequently drooping toward the mid-periphery.

Topographic Appearance: An ellipsoid steep zone extending well beyond the central 4.0 mm zone, creating severe vertical and oblique asymmetry.

Contact Lens Selection: Conventional small corneal RGPs frequently fail because they tilt and rock across the steep superior shoulder of the cone, leading to heavy superior bearing, severe inferior edge standoff, 3 and 9 o'clock staining, and frequent lens ejection. Optimal modalities include large intralimbal RGPs (10.8 mm to 11.8 mm) , hybrid lenses (rigid gas permeable center with a soft silicone hydrogel skirt), or mini-scleral lenses (15.0 mm to 16.5 mm) that vault the decentered cone entirely.

3. Globus Cones

Dimensions: Large diameter, > 6.0 mm > 6.0\ \text{mm} > 6.0 mm , involving > 75 % > 75\% > 75% of the corneal surface .

Location: Generalized, limbus-to-limbus thinning and protrusion.

Topographic Appearance: Diffuse steepening encompassing nearly the entire anterior topography without a distinct transition zone.

Contact Lens Selection: Small corneal GPs may be difficult to stabilize on an extensive or decentered pattern, but they are not categorically contraindicated. A larger corneal, intralimbal, hybrid, custom soft, piggyback, or scleral design may be selected after diagnostic assessment.

Differential Diagnosis: Pellucid Marginal Degeneration (PMD)

PMD is characterized by a narrow, crescentic band of stromal thinning located 1.0 mm to 2.0 mm superior to the inferior limbus. Topography shows high against-the-rule astigmatism with a characteristic but not exclusive "butterfly" or "crab-claw" pattern of inferior steepening wrapping upward around the mid-periphery. PMD often makes a small corneal GP difficult to stabilize, but modality selection remains individualized and can include larger corneal, custom soft, hybrid, piggyback, or scleral designs.

Cone Morphology, Asphericity & Specialty Lens Selection

Classification Physical Diameter Corneal Location Topographic Signature Asphericity ( Q Q Q ) Primary Contact Lens Modality Secondary / Specialty Alternative

Nipple Cone ≤ 5.0 mm \le 5.0\ \text{mm} ≤ 5.0 mm Central / Paracentral Circumscribed round steep island Hyperprolate ( Q < − 0.80 Q < -0.80 Q < − 0.80 ) Small corneal RGP ( 8.5 − 9.2 mm 8.5 - 9.2\ \text{mm} 8.5 − 9.2 mm ) Intralimbal RGP ( 10.5 − 11.2 mm 10.5 - 11.2\ \text{mm} 10.5 − 11.2 mm )

Oval Cone 5.0 − 6.0 mm 5.0 - 6.0\ \text{mm} 5.0 − 6.0 mm Inferotemporal mid-periphery Decentered ellipsoid steep zone Hyperprolate ( Q < − 1.00 Q < -1.00 Q < − 1.00 ) Scleral lens ( 15.0 − 16.5 mm 15.0 - 16.5\ \text{mm} 15.0 − 16.5 mm ) Intralimbal RGP or Hybrid lens

Globus Cone > 6.0 mm > 6.0\ \text{mm} > 6.0 mm Global ( > 75 % > 75\% > 75% of cornea) Generalized limbus-to-limbus steepening Extreme prolate ( Q < − 1.50 Q < -1.50 Q < − 1.50 ) Scleral lens ( 16.5 − 18.5 mm 16.5 - 18.5\ \text{mm} 16.5 − 18.5 mm ) Scleral lens with toric haptics

Pellucid (PMD) Peripheral band Inferior ( 1 − 2 mm 1 - 2\ \text{mm} 1 − 2 mm above limbus) "Crab-claw" / "Butterfly" pattern Severe irregular astigmatism Scleral lens ( 16.0 − 17.5 mm 16.0 - 17.5\ \text{mm} 16.0 − 17.5 mm ) Quadrant-specific bitoric RGP

Post-Myopic Ablation Variable Central optical zone Flat central plateau; steep periphery Oblate ( Q > 0 Q > 0 Q > 0 ) Reverse geometry RGP / Scleral Custom wavefront soft lens