Study guide
8.2 Scleral, Hybrid & RGP Removal Techniques & Emergency Extraction
ABO-NCLE Advanced Contact Lens Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Corneal Topography, Tomography & Anterior Segment Imaging
1.1 Placido-Based Corneal Topography: Axial, Tangential & Elevation Maps 1.2 Corneal Tomography & Scheimpflug Imaging: Anterior/Posterior Elevation & Pachymetry 1.3 Topographic Indices, Asphericity & Cone Localization
2 Chapter 2: Complex Corneal Conditions & Surgical Alterations
2.1 Keratoconus, Pellucid Marginal Degeneration & Keratoglobus 2.2 Post-Keratoplasty (PKP/DALK) & Corneal Cross-Linking (CXL) 2.3 Post-Refractive Ectasia & Post-Refractive Surgery Corneas
3 Chapter 3: Prefit Ocular Surface Evaluation & Candidacy Assessment
3.1 Slit-Lamp Biomicroscopy & Ocular Surface Vital Staining 3.2 Tear Film Dynamics, Dry Eye & Severe Ocular Surface Disease 3.3 Patient History, Visual Needs Analysis & Specialty Lens Selection Strategy
4 Chapter 4: Scleral Lens Design Fundamentals & Sagittal Depth
4.1 Scleral Anatomy, Terminology & Sagittal Depth Principles 4.2 Central Corneal & Limbal Vault Clearance Optimization 4.3 Landing Zone Toricity, Quadrant-Specific Haptics & Edge Profiles
5 Chapter 5: Corneal RGP & Specialty Toric Designs for Irregular Corneas
5.1 Corneal RGP Fitting Philosophies: Apical Clearance vs Bearing vs Three-Point Touch 5.2 Bitoric & High-Toric RGP Calculations: SPE vs CPE & Induced Cylinder 5.3 Lens Materials, Hyper-Dk Polymers & Surface Coatings
6 Chapter 6: Hybrid & Piggyback Contact Lens Systems
6.1 Hybrid Lens Architecture: Rigid Center & Soft Hydrophilic Skirt Fitting 6.2 Hybrid Parameter Selection, Movement & Tear Exchange Optimization 6.3 Piggyback Systems: Carrier Selection, Power Calculations & Hypoxia Prevention
7 Chapter 7: Orthokeratology & Custom Prosthetic Lenses
7.1 Orthokeratology Reverse-Geometry Principles, Jessen Formula & Topographic Patterns 7.2 Prosthetic, Occlusive & Custom Soft Specialty Lenses for Irregular Corneas
8 Chapter 8: Specialty Lens Delivery, Application & Removal Techniques
8.1 Scleral Lens Application Protocols, Plungers & Bubble Prevention 8.2 Scleral, Hybrid & RGP Removal Techniques & Emergency Extraction 8.3 Patient Handling Training, Hygiene & Lens Inspection at Dispense
9 Chapter 9: Filling Solutions, Chemical Disinfection & Wearing Schedules
9.1 Preservative-Free Scleral Reservoir Filling Solutions & Fluid Dynamics 9.2 Disinfection Regimens, Conditioning Systems, Hydra-PEG Care & Adaptation Schedules
10 Chapter 10: Slit-Lamp Fit Evaluation & Optical Troubleshooting
10.1 Settling Time Dynamics & Slit-Lamp Evaluation of Vault Clearance 10.2 Midday Fogging, Tear Reservoir Debris & Lens Surface Wettability 10.3 Over-Refraction, Lenticular Astigmatism & Lens Flexure vs Warpage
11 Chapter 11: In-Office & Laboratory Specialty Lens Modifications
11.1 In-Office Corneal RGP Modifications: Edge Blending, Polishing & Power Changes 11.2 Scleral Parameter Adjustments: Sagittal Depth, Landing Zones & Micro-Vaults 11.3 Ortho-K & Hybrid Fit Problem Solving and Parameter Modifications
12 Chapter 12: Acute Complications, Corneal Pathology & Emergency Triage
12.1 Corneal Hypoxia, Neovascularization & Graft Rejection Recognition 12.2 Mechanical Staining Patterns, Dimple Veiling, Impingement & Conjunctival Prolapse 12.3 Infectious Keratitis, Infiltrative Events & Acute Triage Protocols
13 Chapter 13: Clinical Infection Control, Regulatory Standards & Practice Management
13.1 Diagnostic Fitting Set Decontamination, OSHA & Clinical Infection Control 13.2 FCLCA, Contact Lens Rule, FDA Regulatory Standards & SOAP Documentation
8.2 Scleral, Hybrid & RGP Removal Techniques & Emergency Extraction
Key Takeaways Explain This Topic AI
Removal technique depends on lens type and product instructions; identify whether the lens is corneal GP, scleral, hybrid, or custom soft before selecting a method.
For most scleral lenses, a removal plunger is placed near the inferior or inferotemporal edge to break the seal; central pulling is avoided.
If a scleral lens is tight or painful, lubricate, confirm plunger position, use controlled edge release, and seek clinical help rather than pulling harder.
Hybrid removal follows the exact manufacturer technique to protect the rigid-soft junction; do not assume a scleral plunger method applies.
Teach an approved backup method or caregiver plan, inspect the eye and lens after difficulty, and triage persistent pain, redness, or reduced vision.
Last updated: September 2026
8.2 Scleral, Hybrid, and Corneal GP Removal
Removal begins by identifying the lens. Corneal GPs, sclerals, hybrids, and custom soft lenses interact with lids and ocular tissue differently. Use the technique taught for the exact product and adapt it to the patient's dexterity and anatomy.
Preparation
Wash, rinse, and dry hands. Work over a clean protected surface away from an open drain. Use good lighting and a mirror or stand if helpful. Inspect the eye before removal. Significant pain, marked redness, discharge, trauma, or reduced vision may require immediate clinical advice.
Lubricating the eye with a compatible preservative-free drop can help when the surface is dry. Do not use tap water, saliva, or an unapproved oil.
Scleral Removal with a Plunger
For most scleral designs, look slightly upward and attach the small removal plunger near the inferior or inferotemporal lens edge, not at the center. Gently lift the edge to admit air and release the seal, then guide the lens away.
The purpose is to break the peripheral seal, not to pull the whole fluid reservoir directly forward. Central plunger placement can create excessive suction and should be avoided unless a specific product or clinician explicitly teaches otherwise.
Keep the upper lid controlled so it does not close over the lens during release. Use slow, controlled force. Do not jerk, twist aggressively, or continue pulling through pain.
Manual Scleral Removal
A clinician may teach an approved manual backup method using the lid margin to lift an edge while the patient looks in the directed gaze. Technique varies with diameter, lid anatomy, and lens design. It should be practiced in office before being relied upon at home.
Do not dig a fingernail under the lens or press hard on the globe. If the patient cannot perform a backup method safely, provide a spare plunger, accessible storage plan, or trained caregiver.
A Tight or Stuck Scleral Lens
Pause rather than pulling harder. Verify that the device is a removal plunger and is located at the edge. Add compatible lubrication and allow blinking. Look for conjunctival swelling over the edge, severe compression, or a lens displaced from its normal position.
If the lens will not release with the taught method, or if there is significant pain, stop and contact the clinic. Do not use a sharp object, forceps, improvised suction cup, or repeated digital massage over a sealed lens.
Recurrent tight removal should prompt reassessment of landing-zone alignment, wear time, tissue swelling, edge profile, and application products.
Corneal GP Removal
Common methods include the blink method, in which the lids are positioned beyond opposite lens edges and a blink ejects the lens, or a small GP plunger used according to instruction. The lens should be centered before removal when possible.
Avoid chasing a decentered lens with fingernails. If it moves under a lid, use gaze and lid manipulation as taught; seek help if it cannot be located or if pain persists.
Hybrid Removal
Hybrid lenses have a rigid center bonded to a soft skirt. Follow the current manufacturer's method, which may use dry fingers on the skirt or another specified technique. Avoid pinching, folding, or pulling across the junction. Do not assume that a suction plunger on the rigid center is safe; use one only if the exact product instructions and clinician authorize it.
A dry skirt, tight fit, or technique error can make removal difficult. Lubricate as directed and release the skirt gently. A cracked junction, torn skirt, or separation means the lens should not be reapplied.
After Removal
Inspect the lens for chips, cracks, warpage, deposits, skirt tears, or junction damage. Clean and disinfect it using the prescribed system. Inspect the eye for staining, indentation, rebound redness, epithelial defect, or persistent discomfort when difficulty occurred.
Red Flags
Urgent clinical evaluation is appropriate for persistent pain, photophobia, increasing redness, discharge, reduced vision, suspected abrasion, a broken lens, or inability to remove the lens safely. Do not apply topical anesthetic at home or continue wearing a damaged lens.
Exam Traps
A scleral removal plunger generally goes near an edge, not the center.
Brute force is not a remedy for a stuck lens.
Hybrid technique is manufacturer-specific.
Fingernails and improvised tools are unsafe.
Recurrent removal difficulty is information about fit, tissue response, or training.