1 Introduction

About the NENA ENP Exam

2 Chapter 1: 9-1-1 Evolution & Legacy Network Architecture

1.1 Evolution of 9-1-1 & Central Office Tandem Architecture 1.2 Legacy Location Infrastructure: MSAG, ANI, ALI & ESN/ESZ 1.3 Legacy Network Signaling: CAMA, SS7 & Selective Routing 1.4 Network Design: Originating Service Providers, Local Loops & Transport Facilities 1.5 Signaling, Transport Protocols & Transmission Systems 1.6 Types and Features of 9-1-1 Systems: Basic, Enhanced & NG9-1-1

3 Chapter 2: Modern Location Technologies & MLTS

2.1 Wireless 9-1-1: Phase I, Phase II & Location Accuracy 2.2 Device-Based Location, Supplemental Data & RapidSOS 2.3 MLTS Compliance: Kari's Law & RAY BAUM'S Act

4 Chapter 3: NG911 i3 Core Network & Security

3.1 NG911 Architecture: The ESInet & Core Services 3.2 Border Control Function (BCF) & Security Edge 3.3 SIP Signaling in NG911 (RFC 3261) & Emergency Call Flow

5 Chapter 4: NG911 Location Services & Call Routing

4.1 Location Information Server (LIS) & PIDF-LO 4.2 Emergency Call Routing Function (ECRF) & LoST 4.3 Location Validation Function (LVF) & Legacy Gateways 4.4 NG9-1-1 PSAPs, EIDO, Additional Data & Transitional Elements

6 Chapter 5: Public Safety Radio, Broadband & FirstNet

5.1 Land Mobile Radio (LMR) Architecture & P25 Standards 5.2 Conventional vs. Trunked Radio Systems & Frequency Bands 5.3 Public Safety Broadband, FirstNet & Mission-Critical Services

7 Chapter 6: Call Processing, Accessibility & Protocol Systems

6.1 Call Answering Standards & Answering Point Workflows 6.2 Accessibility: TTY/TDD, Text-to-911 & Real-Time Text (RTT) 6.3 Emergency Protocol Systems & Medical Direction 6.4 PSAP Types & 9-1-1 Call Handling Equipment

8 Chapter 7: Computer Aided Dispatch & Information Systems

7.1 Computer Aided Dispatch (CAD) System Architecture 7.2 CAD Interfaces: Mobile Data, RMS & External Telematics 7.3 Logging Recorders & Synchronized Master Clocks 7.4 Non-Voice Communications & Information Networks 7.5 NENA Standards & Other Documents

9 Chapter 8: GIS for Next Generation 9-1-1

8.1 NG911 GIS Data Layers: Road Centerlines & Address Points 8.2 Boundary Polygons: PSAP, Law, Fire & EMS Jurisdictions 8.3 GIS Data Quality, Topology & Provisioning Workflows 8.4 9-1-1 Databases: Service Orders, ALI & Routing Records, Number Portability & Database Management

10 Chapter 9: Cybersecurity & CJIS Compliance

9.1 PSAP Cybersecurity Frameworks: NENA NG-SEC & NIST CSF 9.2 CJIS Security Policy: Access Control, MFA & Encryption 9.3 TDoS, Ransomware & Cyber Incident Response Planning

11 Chapter 10: Telecommunications Policy, Funding & Civil Rights

10.1 Regulatory Governance: FCC Authority & Part 9 Orders 10.2 9-1-1 Surcharges, Fee Diversion & Federal Grant Programs 10.3 Civil Rights & Language Access: Title VI & ADA Title II 10.4 Telecommunications Service Priority, Public Utility Commissions & the Canadian Framework 10.5 Special Legislative Areas: Alarms, Mass Notification, Pipelines & Other 9-1-1 Laws

12 Chapter 11: PSAP Governance, Strategy & Facility Design

11.1 PSAP Governance Models: Standalone, Co-Located & Consolidated 11.2 Strategic Planning & Performance Management 11.3 PSAP Facility Architecture, Physical Security & Ergonomics 11.4 Management Decision Making & Short-Range, Long-Range & Strategic Planning

13 Chapter 12: Power Redundancy, COOP & Disaster Recovery

12.1 Electrical Power Redundancy: UPS Systems & Generator Sets 12.2 Continuity of Operations Planning (COOP) & Alternate Facilities 12.3 Disaster Recovery, Redundant Connectivity & Evacuation 12.4 Emergency Management: Disaster Types & the Four Phases

14 Chapter 13: Emergency Incident Management & NIMS/ICS

13.1 National Incident Management System (NIMS) & ICS Architecture 13.2 Emergency Operations Centers (EOC) & Incident Command Interfaces 13.3 Mutual Aid & Interagency Interoperability: MACS & MABAS

15 Chapter 14: Procurement, Contracts & Financial Management

14.1 Capital Budgeting, Operational Expense & Financial Auditing 14.2 Public Procurement: RFPs, RFQs & Bid Evaluations 14.3 Vendor Contracting: MSAs, SLAs & Life-Cycle Management

16 Chapter 15: Staffing Models, Scheduling & Wellness

15.1 PSAP Staffing Models: Erlang C & NENA Staffing Calculator 15.2 Shift Scheduling Models, Overtime & Fatigue Mitigation 15.3 Telecommunicator Wellness: CISM, Peer Support & PTSD

17 Chapter 16: Training, CTO Coaching & Quality Assurance

16.1 Adult Learning & Communications Training Officer (CTO) Models 16.2 Quality Assurance & Continuous Quality Improvement (APCO/NENA ANS 1.107) 16.3 Continuing Education, Certifications & Professional Pathways 16.4 Performance Management, Employee Feedback & Customer Service

18 Chapter 17: Employee Relations, Labor Standards & Legal Protections

17.1 Fair Labor Standards Act (FLSA) & Dispatcher Overtime Rules 17.2 EEO, Title VII, FMLA & ADA in the PSAP Workplace 17.3 Progressive Discipline, Just Cause & Union Negotiations 17.4 Employee Relations, Employment Rights & Labor-Management Relations 17.5 Employment Laws: ADEA, Pregnancy Protections, Uniform Guidelines, OSH Act & Canadian Law 17.6 Compensation Laws: Equal Pay Act, COBRA, Social Security Act & Affordable Care Act

19 Chapter 18: Records Governance, Liability & Public Relations

18.1 Public Records, FOIA & Recording Retention Schedules 18.2 Legal Liability, Tort Claims Acts & Immunity Doctrines 18.3 Public Relations, Media Inquiries & Community Outreach

20 Chapter 19: Recruiting, Hiring, Compensation & Retention

19.1 Recruiting: Workforce Needs, Outreach & Sourcing 19.2 Hiring Procedures: Testing, Interview Panels, Agency Tours & Background Checks 19.3 Compensation & Benefits: Job Analysis, Pay Structures & Medical Benefits 19.4 Employee Retention & Succession Planning

1.3 Legacy Network Signaling: CAMA, SS7 & Selective Routing

Key Takeaways Explain This Topic AI

Centralized Automatic Message Accounting (CAMA) trunks utilize in-band Multi-Frequency (MF) tones and reverse-battery wink-start supervision over 4-wire analog or DS0 circuits to transmit 7-, 8-, or 10-digit ANI.

Signaling System No. 7 (SS7) provides out-of-band Common Channel Signaling (CCS), utilizing ISDN User Part (ISUP) messaging (IAM, ACM, ANM) across high-speed data links to achieve sub-second call setup and native 10-digit ANI delivery.

ISDN Primary Rate Interface (ISDN-PRI) terminates 23 Bearer channels (voice) and 1 Delta channel (Q.931 packet signaling) into PSAP CPE, supporting Calling Party Subaddressing and dynamic channel management.

The E9-1-1 Selective Router (SR) tandem switch interrogates its internal Selective Routing Database (SRDB) using calling ANI to select the primary PSAP, falling back to Default Routing on data failure or Alternate Routing on facility/trunk saturation.

CAMA circuits suffer from unidirectional operation, slow 1.5–3.0 second setup latency, and trunk glare vulnerability, contrasting with bidirectional, monitored SS7 and ISDN-PRI architectures.

Last updated: September 2026

1.3 Legacy Network Signaling: CAMA, SS7 & Selective Routing

Quick Answer: Legacy 9-1-1 call delivery relies on three primary telecommunications signaling protocols: Centralized Automatic Message Accounting (CAMA) utilizing in-band Multi-Frequency (MF) tones over analog/DS0 circuits, Signaling System No. 7 (SS7) utilizing out-of-band Common Channel Signaling (CCS) with ISUP messaging, and ISDN Primary Rate Interface (ISDN-PRI) terminating 23B+D channels into PSAP call-handling equipment. When a call reaches the E9-1-1 Selective Router tandem, the switch buffers the incoming ANI, queries its high-speed Selective Routing Database (SRDB) to identify the Emergency Service Number (ESN), and selects the primary PSAP trunk group. If ANI is missing or unresolvable (data failure), the router invokes Default Routing; if primary PSAP trunks are fully saturated or cut (facility failure), it invokes Alternate Routing.

1. Architecture of Dedicated Emergency Trunking

In public safety telecommunications, 9-1-1 calls are strictly prohibited from traversing shared, public inter-office trunks (IOTs). If emergency calls competed with commercial traffic on general telephone company trunk groups, a sudden surge in consumer calling (such as Mother's Day, severe weather, or commercial promotions) would generate "All Circuits Busy" conditions, blocking life-safety emergency calls.

To prevent contention, telephone companies engineer dedicated 9-1-1 trunk groups between Class 5 Central Offices, Selective Routers, and Public Safety Answering Points (PSAPs):

Physical Transport: Dedicated emergency trunks operate over channelized DS0 circuits (64 kbps digital time-slots within a 1.544 Mbps T1 carrier) or legacy 4-wire balanced analog audio pairs.

Engineering Rule: Every trunk group is sized according to strict traffic engineering formulas to achieve a P.01 Grade of Service , guaranteeing that during the Average Busy Hour (ABH), no more than 1% of emergency calls encounter a trunk busy signal.

2. Centralized Automatic Message Accounting (CAMA) Protocol Deep Dive

Originally engineered by the Bell System in the 1940s and 1950s to automate toll call billing for long-distance telephone service, CAMA was adapted in the 1970s as the de facto signaling standard for connecting Class 5 Central Offices to E9-1-1 Selective Routers, and Selective Routers to PSAP customer premises equipment (CPE).

Physical Transport & Supervisory Signaling

Transmission Circuit: Deployed over dedicated 4-wire analog circuits (separate transmit and receive pairs) or dedicated 64 kbps DS0 channels on digital T1 carriers.

Supervisory Signaling (E&M / Reverse Battery): CAMA uses DC loop signaling to indicate circuit states:

Seizure (Off-Hook): The originating Central Office seizes the idle trunk by applying an off-hook loop closure.

Wink Start Acknowledgment: When ready to receive digits, the Selective Router reverses circuit DC battery polarity for 140 to 290 milliseconds . This pulse is known as a wink start .

Digit Outpulsing: Upon detecting the wink, the Central Office pulses audio tones across the line.

Answer & Cut-Through: When the PSAP answers, a steady reverse-battery condition cuts through the two-way audio path and commences call timing.

Disconnect: Dropping loop current restores the circuit to an idle state.

In-Band Multi-Frequency (MF) Signaling Mechanics

CAMA transmits signaling data directly over the audio voice pair ( in-band ). It does not use consumer DTMF touch-tones. Instead, it uses Multi-Frequency (MF) signaling, combining two discrete audio frequencies selected from a pool of six tones (700, 900, 1100, 1300, 1500, and 1700 Hz): Transmission = [ KP ] + [ Information Digit ] + [ ANI Digits ] + [ ST ] \text{Transmission} = [\text{KP}] + [\text{Information Digit}] + [\text{ANI Digits}] + [\text{ST}] Transmission = [ KP ] + [ Information Digit ] + [ ANI Digits ] + [ ST ]

Key Pulse (KP): Pulsed at 1100 Hz + 1700 Hz for approximately 100 ms to prepare receiving registers.

Information Digit (Class of Service): Identifies line class (0 = standard line, 1 = multi-party line, 2 = ANI failure, 9 = test call).

ANI Digits: Traditional CAMA transmits 7 digits (NXX-XXXX). Modified/Extended CAMA transmits 10 digits ( KP + 0 + NPA + NXX + XXXX + ST ) or uses a two-burst sequence (NPA followed by NXX-XXXX) to support area code overlays.

Start Pulse (ST): Pulsed at 1500 Hz + 1700 Hz to indicate completion of the digit stream.

Architectural Limitations of CAMA

Unidirectional Operation: CAMA trunks are strictly one-way (inbound to the PSAP). Call takers cannot originate outbound calls over CAMA facilities.

Call Setup Latency: Wink start, tone pulsing, and audio cut-through add noticeable setup delay (commonly a few seconds) before voice connection occurs.

In-Band Tone Bleed: Tones travel across the speech path; premature audio cut-through can result in audible MF beeps.

Data Capacity Constraints: CAMA cannot transmit alphanumeric text, caller names, or coordinates over the voice channel; location delivery requires an out-of-band query to an ALI database.

3. Signaling System No. 7 (SS7) & Out-of-Band Common Channel Signaling

As telephone networks modernized, Signaling System No. 7 (SS7) superseded CAMA between digital Central Offices and modern Selective Routers.

Common Channel Signaling (CCS) Architecture

SS7 completely decouples voice audio from signaling control:

Bearer Channels (DS0): Digital 64 kbps voice paths carry purely user speech.

Common Channel Signaling Links (56/64 kbps): High-speed packet-switched data networks operating in parallel carry call setup, supervisory control, and routing messages for thousands of circuits.

SS7 Network Nodes & ISUP Call Flow

SS7 utilizes three primary nodes: Service Switching Points (SSP) (originating/tandem switches), Signal Transfer Points (STP) (packet switches in redundant mated pairs), and Service Control Points (SCP) (centralized databases).

Emergency calls execute setup via the ISDN User Part (ISUP) protocol:

Initial Address Message (IAM): The originating SSP reserves an idle voice trunk (identified by a Circuit Identification Code - CIC) and transmits an IAM packet containing the full 10-digit Calling Party Number (CPN/ANI), Called Party Number (9-1-1), and Originating Line Information (OLI).

Address Complete Message (ACM): The Selective Router confirms circuit reservation and returns an ACM packet indicating that the destination is ringing.

Answer Message (ANM): When the PSAP answers, an ANM packet triggers instantaneous voice cut-through.

Release (REL) & Release Complete (RLC): Structured packet handshake that terminates the call and returns the trunk to idle.

SS7 Advantages over CAMA

Faster Setup: SS7 exchanges ISUP messages out-of-band, so call setup is typically much faster than in-band MF pulsing and the voice path carries no signaling tones.

Native 10-Digit ANI: Eliminates number truncation and modified CAMA complexity.

Continuous Circuit Telemetry: SS7 continuously monitors link integrity and voice trunk continuity, automatically routing around facility failures.

4. ISDN Primary Rate Interface (ISDN-PRI) Demarcation

While SS7 handles inter-office trunking, ISDN Primary Rate Interface (ISDN-PRI) is the premier digital standard terminating high-density trunk groups from the Selective Router directly into PSAP call-handling equipment (CPE).

The 23B+D Channel Architecture

In North America, an ISDN-PRI operates over a channelized 1.544 Mbps T1 carrier structured into 24 discrete 64 kbps time-slots:

23 B-Channels (Bearer Channels): Channels 1 through 23 carry clear-channel digital voice audio (G.711 PCM sampled at 8 kHz with 8-bit resolution).

1 D-Channel (Delta Channel): Channel 24 is dedicated to out-of-band call signaling using the ITU-T Q.931 protocol.

Q.931 Signaling & Information Elements

Call supervision on ISDN-PRI uses structured Q.931 packets: SETUP (carries 10-digit ANI, Bearer Capability, and Channel ID Information Elements), CALL PROCEEDING , ALERTING , CONNECT , and DISCONNECT/RELEASE .

Non-Facility Associated Signaling (NFAS)

In large communications centers requiring multiple T1 circuits, NFAS enables a single D-channel on a primary T1 to control B-channels across up to 20 separate T1 lines (up to 478 B-channels). A backup D-channel on a secondary T1 ensures seamless failover if the primary circuit experiences a physical cut.

5. The E9-1-1 Selective Router Tandem Switch & Routing Matrix

The Selective Router (SR) is a carrier-grade tandem switch (such as a Lucent 5ESS or Nortel DMS-100) that aggregates emergency traffic from Central Offices and routes it to regional PSAPs.

Selective Routing Database (SRDB) Mechanics

The router operates using memory translation tables:

ANI Ingestion: The SR buffers the incoming 10-digit or 7-digit ANI from the CAMA or SS7 trunk.

SRDB Indexing: The SR performs an in-memory lookup in the Selective Routing Database (SRDB) , associating the ANI with a unique Emergency Service Number (ESN) .

Trunk Translation: The SR references its trunk translation table to map the ESN to the outgoing dedicated trunk group connected to the Primary PSAP .

Outpulsing: The SR seizes an idle channel in that trunk group and delivers the call and ANI to the PSAP.

6. Selective Router Routing Hierarchy & Failover Logic

To ensure that life-safety calls are never lost, the Selective Router executes a deterministic failover hierarchy:

Primary Selective Routing: Normal operation. The incoming ANI matches an SRDB entry, resolves to an ESN, and terminates at the primary PSAP.

Default Routing (Data Failure Mode): Triggers when the router cannot identify the caller's telephone number or location. This occurs when ANI is missing, unlisted, corrupted by line noise, or arriving from trunks lacking ANI capability. Because selective routing cannot be performed, the router executes a hardcoded trunk table: every call arriving over that specific incoming Central Office trunk group is steered to a pre-assigned Default PSAP responsible for that wire center's general territory.

Alternate Routing (Facility / Capacity Failure Mode): Triggers when dedicated trunks to the primary PSAP are saturated ( All Trunks Busy - ATB ) or physically severed. The router automatically diverts calls to a designated backup PSAP, secondary facility, or 10-digit administrative rollover number.

Night Service: Scheduled time-of-day diversion, rerouting calls to a consolidated 24-hour dispatch center.

Trunk Glare Protection

In telephony, glare occurs when both ends of a two-way trunk attempt simultaneous seizure, causing call collision. To eliminate glare, legacy 9-1-1 networks mandate that CAMA and basic PSAP emergency trunks operate strictly as one-way incoming circuits to the PSAP.

7. End-to-End Signaling Comparison Matrix

Technical Attribute CAMA (Analog / Digital MF) SS7 (Common Channel Signaling) ISDN-PRI (Primary Rate Interface)

Signaling Method In-band Multi-Frequency (MF) tones Out-of-band packet-switched CCS Out-of-band packet-switched (Q.931)

Signaling Channel Carried directly on talk path Dedicated 56/64 kbps data link Dedicated 64 kbps D-Channel (ch 24)

Supervisory Handshake Reverse-battery Wink Start (140-290 ms) ISUP Messages (IAM, ACM, ANM) Q.931 Messages (SETUP, CONNECT)

ANI Transmission In-band MF ( KP + COS + ANI + ST ) Digital data field in IAM packet Information Element (IE) in SETUP

ANI Capacity 7 or 8 digits (standard); 10 (modified) Native 10-digit (CPN / ANI) Native 10-digit (CPN / Subaddress)

Setup Latency Slowest (seconds of in-band MF pulsing) Faster (out-of-band ISUP messaging) Faster (D-channel Q.931 messaging)

Directionality One-way incoming only (no glare) Two-way capable with glare control Dynamic two-way channel allocation

Primary Area Class 5 to SR / SR to Legacy PSAP Central Office to Selective Router Selective Router to Modern PSAP CPE

Fault Telemetry Blind until seized (circuit testing needed) Continuous link & trunk monitoring Continuous D-channel keepalive

8. Operational Traps & ENP Exam Watch

MF Tones vs. DTMF Tones: Do not confuse consumer DTMF (touch-tones) with Multi-Frequency (MF) tones used on CAMA trunks. CAMA uses 2-of-6 inter-office frequencies (700, 900, 1100, 1300, 1500, 1700 Hz) framed by KP and ST.

The Wink Start Handshake: A CAMA trunk requires the receiving switch/PSAP to return a momentary reverse-battery pulse lasting 140 to 290 milliseconds . Without a wink, the originating switch times out and logs an ANI failure.

Default Routing vs. Alternate Routing Root Causes: Default Routing = Data Failure (missing or garbled ANI). Alternate Routing = Facility / Capacity Failure (trunks saturated or severed).