Study guide

1.4 Network Design: Originating Service Providers, Local Loops & Transport Facilities

NENA Emergency Number Professional ENP

Track your progress as you read

Finished sections get a check mark.

1 Introduction

About the NENA ENP Exam

2 Chapter 1: 9-1-1 Evolution & Legacy Network Architecture

1.1 Evolution of 9-1-1 & Central Office Tandem Architecture 1.2 Legacy Location Infrastructure: MSAG, ANI, ALI & ESN/ESZ 1.3 Legacy Network Signaling: CAMA, SS7 & Selective Routing 1.4 Network Design: Originating Service Providers, Local Loops & Transport Facilities 1.5 Signaling, Transport Protocols & Transmission Systems 1.6 Types and Features of 9-1-1 Systems: Basic, Enhanced & NG9-1-1

3 Chapter 2: Modern Location Technologies & MLTS

2.1 Wireless 9-1-1: Phase I, Phase II & Location Accuracy 2.2 Device-Based Location, Supplemental Data & RapidSOS 2.3 MLTS Compliance: Kari's Law & RAY BAUM'S Act

4 Chapter 3: NG911 i3 Core Network & Security

3.1 NG911 Architecture: The ESInet & Core Services 3.2 Border Control Function (BCF) & Security Edge 3.3 SIP Signaling in NG911 (RFC 3261) & Emergency Call Flow

5 Chapter 4: NG911 Location Services & Call Routing

4.1 Location Information Server (LIS) & PIDF-LO 4.2 Emergency Call Routing Function (ECRF) & LoST 4.3 Location Validation Function (LVF) & Legacy Gateways 4.4 NG9-1-1 PSAPs, EIDO, Additional Data & Transitional Elements

6 Chapter 5: Public Safety Radio, Broadband & FirstNet

5.1 Land Mobile Radio (LMR) Architecture & P25 Standards 5.2 Conventional vs. Trunked Radio Systems & Frequency Bands 5.3 Public Safety Broadband, FirstNet & Mission-Critical Services

7 Chapter 6: Call Processing, Accessibility & Protocol Systems

6.1 Call Answering Standards & Answering Point Workflows 6.2 Accessibility: TTY/TDD, Text-to-911 & Real-Time Text (RTT) 6.3 Emergency Protocol Systems & Medical Direction 6.4 PSAP Types & 9-1-1 Call Handling Equipment

8 Chapter 7: Computer Aided Dispatch & Information Systems

7.1 Computer Aided Dispatch (CAD) System Architecture 7.2 CAD Interfaces: Mobile Data, RMS & External Telematics 7.3 Logging Recorders & Synchronized Master Clocks 7.4 Non-Voice Communications & Information Networks 7.5 NENA Standards & Other Documents

9 Chapter 8: GIS for Next Generation 9-1-1

8.1 NG911 GIS Data Layers: Road Centerlines & Address Points 8.2 Boundary Polygons: PSAP, Law, Fire & EMS Jurisdictions 8.3 GIS Data Quality, Topology & Provisioning Workflows 8.4 9-1-1 Databases: Service Orders, ALI & Routing Records, Number Portability & Database Management

10 Chapter 9: Cybersecurity & CJIS Compliance

9.1 PSAP Cybersecurity Frameworks: NENA NG-SEC & NIST CSF 9.2 CJIS Security Policy: Access Control, MFA & Encryption 9.3 TDoS, Ransomware & Cyber Incident Response Planning

11 Chapter 10: Telecommunications Policy, Funding & Civil Rights

10.1 Regulatory Governance: FCC Authority & Part 9 Orders 10.2 9-1-1 Surcharges, Fee Diversion & Federal Grant Programs 10.3 Civil Rights & Language Access: Title VI & ADA Title II 10.4 Telecommunications Service Priority, Public Utility Commissions & the Canadian Framework 10.5 Special Legislative Areas: Alarms, Mass Notification, Pipelines & Other 9-1-1 Laws

12 Chapter 11: PSAP Governance, Strategy & Facility Design

11.1 PSAP Governance Models: Standalone, Co-Located & Consolidated 11.2 Strategic Planning & Performance Management 11.3 PSAP Facility Architecture, Physical Security & Ergonomics 11.4 Management Decision Making & Short-Range, Long-Range & Strategic Planning

13 Chapter 12: Power Redundancy, COOP & Disaster Recovery

12.1 Electrical Power Redundancy: UPS Systems & Generator Sets 12.2 Continuity of Operations Planning (COOP) & Alternate Facilities 12.3 Disaster Recovery, Redundant Connectivity & Evacuation 12.4 Emergency Management: Disaster Types & the Four Phases

14 Chapter 13: Emergency Incident Management & NIMS/ICS

13.1 National Incident Management System (NIMS) & ICS Architecture 13.2 Emergency Operations Centers (EOC) & Incident Command Interfaces 13.3 Mutual Aid & Interagency Interoperability: MACS & MABAS

15 Chapter 14: Procurement, Contracts & Financial Management

14.1 Capital Budgeting, Operational Expense & Financial Auditing 14.2 Public Procurement: RFPs, RFQs & Bid Evaluations 14.3 Vendor Contracting: MSAs, SLAs & Life-Cycle Management

16 Chapter 15: Staffing Models, Scheduling & Wellness

15.1 PSAP Staffing Models: Erlang C & NENA Staffing Calculator 15.2 Shift Scheduling Models, Overtime & Fatigue Mitigation 15.3 Telecommunicator Wellness: CISM, Peer Support & PTSD

17 Chapter 16: Training, CTO Coaching & Quality Assurance

16.1 Adult Learning & Communications Training Officer (CTO) Models 16.2 Quality Assurance & Continuous Quality Improvement (APCO/NENA ANS 1.107) 16.3 Continuing Education, Certifications & Professional Pathways 16.4 Performance Management, Employee Feedback & Customer Service

18 Chapter 17: Employee Relations, Labor Standards & Legal Protections

17.1 Fair Labor Standards Act (FLSA) & Dispatcher Overtime Rules 17.2 EEO, Title VII, FMLA & ADA in the PSAP Workplace 17.3 Progressive Discipline, Just Cause & Union Negotiations 17.4 Employee Relations, Employment Rights & Labor-Management Relations 17.5 Employment Laws: ADEA, Pregnancy Protections, Uniform Guidelines, OSH Act & Canadian Law 17.6 Compensation Laws: Equal Pay Act, COBRA, Social Security Act & Affordable Care Act

19 Chapter 18: Records Governance, Liability & Public Relations

18.1 Public Records, FOIA & Recording Retention Schedules 18.2 Legal Liability, Tort Claims Acts & Immunity Doctrines 18.3 Public Relations, Media Inquiries & Community Outreach

20 Chapter 19: Recruiting, Hiring, Compensation & Retention

19.1 Recruiting: Workforce Needs, Outreach & Sourcing 19.2 Hiring Procedures: Testing, Interview Panels, Agency Tours & Background Checks 19.3 Compensation & Benefits: Job Analysis, Pay Structures & Medical Benefits 19.4 Employee Retention & Succession Planning

1.4 Network Design: Originating Service Providers, Local Loops & Transport Facilities

Key Takeaways Explain This Topic AI

Originating service providers include incumbent and competitive local exchange carriers (ILECs and CLECs), wireless carriers, and VoIP service providers; interexchange carriers (IXCs) carry long-distance traffic rather than local 9-1-1 calls.

Interconnected VoIP providers must deliver E9-1-1 with a callback number and location, using a VoIP Positioning Center and ESQK pseudo-ANI in legacy networks or native SIP in NG9-1-1.

An area code overlay adds a new code over the same region and requires 10-digit local dialing, while a split changes some customers' area code and requires ALI and routing updates.

Transport facilities (copper, fiber, microwave, and coaxial cable) differ in capacity, power dependence, and failure modes, so resilient 9-1-1 designs use route and media diversity.

TDoS attacks flood voice lines and DDoS attacks flood IP systems; defenses include carrier filtering, BCF rate limiting, overflow routing, and incident response plans that avoid blocking legitimate 9-1-1 calls.

Last updated: September 2026

1.4 Network Design: Originating Service Providers, Local Loops & Transport Facilities

Quick Answer: Every 9-1-1 call starts with an originating service provider (OSP) : an incumbent or competitive local exchange carrier (ILEC or CLEC), a wireless carrier, or a VoIP service provider (VSP). The call travels over a local loop (copper, coaxial cable, fiber, or radio) to the provider's switch or softswitch, then over dedicated 9-1-1 trunks or IP links to a selective router or NG9-1-1 core. Transport facilities include copper, fiber optic, microwave, and coaxial cable , each with different capacity, power, and failure characteristics. Numbering changes such as area code overlays and splits , the N-1-1 codes , and quality-of-service and security threats ( TDoS and DDoS ) all affect how reliably calls reach the PSAP.

1. Originating Service Providers (OSPs)

The ENP Body of Knowledge groups the companies that originate 9-1-1 calls under originating service providers . Each type connects to the 9-1-1 network differently and falls under different rules.

Provider Type What It Is How It Reaches 9-1-1 9-1-1 Considerations

Incumbent LEC (ILEC) The traditional local telephone company that owned the local network before competition (regional Bell companies and independent telcos) End office to selective router over dedicated 9-1-1 trunks; often also the legacy 9-1-1 system service provider Historically maintained ALI and selective routing databases under state tariffs

Competitive LEC (CLEC) A local carrier that entered the market after the Telecommunications Act of 1996 opened local competition Interconnects its switch to the selective router and sends subscriber records to the 9-1-1 database provider Must arrange 9-1-1 interconnection and keep its customers' ALI records accurate

Interexchange Carrier (IXC) A long-distance carrier that carries calls between local access and transport areas (LATAs) Does not normally originate local 9-1-1 calls Matters for administrative lines, long-haul transport, and backbone diversity

Wireless (CMRS) Carrier Cellular and PCS providers Mobile switching center to selective router, or IP to NG9-1-1 Phase I and Phase II location and location-based routing (Chapter 2)

VoIP Service Provider (VSP) Providers of voice over IP, including cable companies and over-the-top services VoIP Positioning Center and pseudo-ANI into the selective router, or native SIP into NG9-1-1 Interconnected VoIP must provide E9-1-1 with registered or dispatchable location

Interconnected VoIP and 9-1-1

The FCC's 2005 VoIP 9-1-1 order required interconnected VoIP providers (services that use a broadband connection, need IP-compatible equipment, and let users both receive calls from and place calls to the public telephone network) to deliver 9-1-1 calls with the caller's callback number and Registered Location . In legacy networks, a VoIP Positioning Center (VPC) assigns an ESQK pseudo-ANI so the selective router can route the call and the ALI database can return the location. Under the rules implementing RAY BAUM'S Act Section 506, fixed VoIP must now deliver dispatchable location automatically, and non-fixed (nomadic) VoIP must deliver dispatchable location or an approved alternative.

  • 2. The Local Loop and Numbering
  • The Local Loop

The local loop (the "last mile") connects the customer's premises to the provider's central office or network node:

Copper twisted pair: Traditional plain old telephone service (POTS). The central office supplies roughly -48 volts DC over the loop, so a corded phone keeps working during a commercial power outage as long as the central office has power.

Coaxial cable: Hybrid fiber-coax cable plant carries voice as VoIP, and the modem at the home needs local power.

Fiber: Fiber to the premises carries voice through an optical network terminal that also needs local power.

Fixed wireless: Radio links to the home, which likewise depend on local power.

Because fiber, cable, and fixed wireless home voice service is not line powered , FCC rules require providers of those services to offer subscribers backup power options (an 8-hour option and a 24-hour option) and to explain that service will not work in an outage without backup power. PSAP public education should explain this limitation, especially to people who rely on a home phone.

Area Code Overlays and Splits

When a numbering plan area (NPA) runs out of numbers, regulators add capacity in one of two ways:

Geographic split: The region is divided, and customers in one part receive a new area code. Their telephone numbers change, so ALI records, selective routing tables, and callback data must be updated carefully.

Overlay: A new area code is added over the same geography. Existing customers keep their numbers, but 10-digit local dialing becomes necessary because two area codes serve the same place.

9-1-1 is still dialed as three digits in both cases. The larger risks are database and equipment updates: PSAPs should verify that CAD, ALI displays, callback functions, and speed dials handle the new area code. The 2020 designation of 988 for the Suicide and Crisis Lifeline forced 10-digit local dialing in areas that used 988 as a local exchange prefix, a reminder that numbering decisions ripple into PSAP systems.

N-1-1 Abbreviated Dialing Codes

The FCC assigns several N-1-1 codes that PSAPs deal with regularly:

  • Code Use PSAP Relevance
  • 2-1-1 Community information and referral services Referral option for non-emergency social service needs
  • 3-1-1 Non-emergency municipal government services Reduces non-emergency load on 9-1-1 lines
  • 5-1-1 Traffic and transportation information Road closure and travel information

7-1-1 Telecommunications Relay Services (TRS) Relay users can reach PSAP administrative lines, but 9-1-1 itself must accept direct TTY and text

  • 8-1-1 "Call before you dig" utility locating Pipeline and utility damage prevention (Chapter 10)
  • 9-1-1 Emergency services The universal emergency number

Directory assistance (4-1-1) and repair service (6-1-1) are carrier conventions rather than FCC assignments.

3. Transport Facilities

The physical media that connect customers, central offices, selective routers, ESInets, and PSAPs have distinct strengths and weaknesses:

Medium Capacity Strengths Weaknesses Typical 9-1-1 Use

Copper Low (DS0 up to T1 per pair) Line powered, widely installed Distance limits, electrical noise, corrosion, cable theft Legacy CAMA trunks, administrative lines, older ALI data circuits

Fiber optic Very high (gigabits and more) Immune to electrical interference, long reach Vulnerable to cuts, needs powered electronics ESInet backbones, SONET rings, carrier transport

Microwave Moderate to high Quick to deploy, avoids buried-cable cuts Needs line of sight, rain fade at higher frequencies, depends on towers Backup paths, radio system backhaul, remote sites

Coaxial cable High but shared Uses existing cable plant Shared capacity, needs amplifiers and local power Cable VoIP subscribers, some agency links

Designing for Diversity

A single cut should never isolate a PSAP. Common design practices include:

Route diversity: Two paths that do not share conduit, poles, bridges, or building entrances (Chapter 12).

Media diversity: Pairing fiber with licensed microwave or with another carrier's facilities.

Trunk distribution: Splitting 9-1-1 trunk groups across separate facilities and, in NG9-1-1, across geographically separate core sites.

Monitoring: Circuit alarms with clear escalation, backed by the FCC's rules requiring providers to notify PSAPs of 9-1-1 outages.

4. Trunking, Switching, and Routing Configurations

Several network configurations appear on the exam and connect to other sections:

Direct trunked: Each end office sends 9-1-1 calls straight to one PSAP over dedicated trunks, common in Basic 9-1-1 (1.1).

Tandem (selective router): End offices trunk to a 9-1-1 tandem that selects the PSAP by ESN. Older analog tandems relied on MF signaling; digital tandems support SS7 and digital trunks.

End office routing: The end office itself selects the PSAP, which works only when office boundaries match PSAP boundaries.

Grade of service: Trunk groups are sized for a blocking probability, typically P.01 (1 call in 100 blocked in the busy hour), using Erlang B (1.1 and 6.1).

Wireless and PBX interconnection: Mobile switching centers and MLTS/PS-ALI systems use their own trunking and database arrangements (Chapter 2).

Common practice is to provision at least two 9-1-1 trunks from each originating office, over diverse facilities where possible, so one failure does not block all calls.

  • 5. Quality of Service and Network Security
  • Quality of Service (QoS)

Once calls move onto IP networks, voice quality depends on delay, jitter, and packet loss. ESInet designs mark voice traffic for priority queuing and use carrier service-level agreements to bound delay (3.1).

Telephone Denial of Service (TDoS) and DDoS

TDoS floods 9-1-1 or administrative lines with automated or malicious calls so legitimate callers cannot get through. In October 2016, a malicious link that made iPhones dial 9-1-1 repeatedly disrupted PSAPs in several states.

Distributed Denial of Service (DDoS) overwhelms IP systems, such as ESInet interfaces, CAD servers, or public websites, with traffic from many sources.

Defenses include carrier-level filtering, call-pattern monitoring, BCF rate limiting and anomaly detection in NG9-1-1, overflow routing to partner PSAPs, and incident response plans (3.2 and 9.3). Because federal rules protect calls to 9-1-1 from caller ID-based blocking, mitigation must avoid dropping legitimate emergency calls.

6. Operational Traps & ENP Exam Watch

CLEC vs. IXC: CLECs compete for local service after the 1996 Act; IXCs carry long-distance traffic between LATAs.

Overlay vs. Split: Overlays keep existing numbers but require 10-digit local dialing; splits change some customers' area codes.

Line Power: Only traditional copper POTS is powered from the central office; fiber, cable, and VoIP phones need local backup power.

Interconnected VoIP: The E9-1-1 obligation applies to interconnected VoIP (two-way calling with the public network), not to every internet voice app.

7-1-1 Is Not a 9-1-1 Substitute: Relay users may reach PSAP administrative lines through 7-1-1, but PSAPs must still provide direct TTY and text access to 9-1-1.