1 CT System Hardware & X-Ray Generation
X-Ray Tube Design and Focal Spots Tube Heat Loading, Bearings and Cooling Beam Filtration and Collimation Scanner Generations and Source/Detector Geometry Detector Technology & Data Acquisition Systems (DAS)
2 Gantry Mechanics & Ancillary Systems
Gantry Architecture, Clearance and Centering Slip Rings, Couch Motion and Load Safety Power Injector Hardware and Safety DICOM, Worklists and Image Archiving
3 Data Acquisition & Scanning Geometries
Axial vs. Helical Scanning & Pitch Mechanics Localizer/Scout Scans & Isocenter Alignment Beam Geometry, Slice Collimation & Data Sampling
4 Mathematical Reconstruction & Image Processing
Projection Data, Image Matrices and Voxel Sampling Filtered Back Projection and Reconstruction Kernels Iterative Reconstruction & AI-Powered Algorithms Hounsfield Unit Scale, Linear Attenuation & Windowing (WW/WL)
5 3D Visualization & Advanced Post-Processing
Multiplanar Reformation (MPR) & Curved Planar Reformation (CPR) Volume Rendering, Maximum/Minimum Intensity Projections & Virtual Endoscopy
6 Image Quality & Performance Metrics
Spatial Resolution, Modulation Transfer Function & Matrix Parameters MTF and Spatial-Resolution Testing Contrast Resolution, Quantum Noise & Temporal Resolution Interdependence of Image Quality Parameters & Radiation Dose
7 CT Artifacts Identification & Correction
Physics-Based Artifacts: Beam Hardening, Cupping & Partial Volume Averaging Equipment & Patient Artifacts: Ring, Motion, Metal & Windmill Effects
8 Quality Assurance & Routine Testing
Daily Quality Control: Water Calibration, Noise & Field Uniformity Periodic Quality Assurance: ACR Phantom Testing & Geometry Verification
9 Patient Communication, Screening & Preparation
Patient Identification, Clinical Screening & Pregnancy Protocols Informed Consent, Pre-Scan Fasting & Anxiety Management Patient Monitoring, Vital Signs Assessment & ECG Gating Setup
10 Infection Control & Medical Emergency Response
Infection Control, Aseptic Technique & Scanner Disinfection Medical Emergencies in the CT Suite: Vasovagal Reactions, Seizures & Code Protocols
11 Contrast Media Chemistry & Administration
Iodinated Contrast Properties: Osmolality, Viscosity & Molecular Structure Contrast Volume, Flow, Duration and Iodine Delivery Intravenous Access, Catheter Gauges & Power Injection Protocols Bolus Tracking, Test Bolus & Contrast Transit Dynamics
12 Non-Vascular Contrast & Adverse Reactions
Oral, Rectal and Enteral Contrast Intrathecal, Intra-articular and Cavitary Contrast Renal Impairment, CI-AKI Risk & Metformin Management Contrast Reactions: Categorization, Prophylaxis & Emergency Treatment
13 Neuroimaging & Head/Neck CT Protocols
Routine Brain and Trauma CT Technique Stroke, Hemorrhage and Targeted Skull-Base CT Facial Bones, Orbits & High-Resolution Temporal Bones Soft Tissue Neck & Paranasal Sinuses Protocols
14 Thoracic & Cardiovascular CT Protocols
Routine Chest CT: Pulmonary Parenchyma & Mediastinal Anatomy High-Resolution CT (HRCT) for Diffuse Interstitial Lung Disease Pulmonary Embolism & Cardiac CT Protocols
15 Abdominal & Pelvic CT Protocols
Multiphase Liver, Pancreas & Renal CT Protocols Gastrointestinal CT: Enterography, Colonography & Acute Abdomen Pelvic Cross-Sectional Anatomy & Gynecologic/Urologic Pathology
16 Musculoskeletal, Vascular & Interventional CT
Cervical, Thoracic and Lumbosacral Spine CT Extremity, Joint and Orthopedic Hardware CT CT Angiography (CTA): Carotid, Aortic & Peripheral Runoff Protocols CT-Guided Interventions: Biopsy, Abscess Drainage & Procedural Safety
17 Hybrid PET/CT and SPECT/CT Procedures
PET/CT Anatomy, Physiology and Attenuation Correction SPECT/CT Anatomy, Physiology and Attenuation Correction
18 Radiation Biology & Dose Descriptors
Radiation Physics, Cellular Interactions & Biological Risk Models Tissue Reactions, Stochastic Risk and Justification CTDI Measurement and Phantom References CTDI Weighting, Pitch and DLP Calculations Size-Specific Dose Estimates Effective-Dose Estimates and Diagnostic Reference Levels
19 Radiation Protection & Dose Optimization
Technical Dose Reduction: Tube Current Modulation & Pediatric ALARA Pediatric, Body-Habitus and Pregnancy Optimization Personnel Protection, Distance and Shielding Jurisdiction, Dose Limits and Personnel Monitoring
Infection Control, Aseptic Technique & Scanner Disinfection
Key Takeaways Explain This Topic AI
Hand hygiene is required even when gloves are used.
Device reprocessing follows the manufacturer and infection-control policy.
Transmission precautions depend on the suspected organism and exposure.
Last updated: October 2026
Infection prevention in a shared CT environment
A CT room repeatedly receives patients with different infection risks, including patients whose infection has not yet been recognized. Standard precautions therefore apply to every patient. They include hand hygiene, risk-based personal protective equipment (PPE), safe injection practices, sharps safety and cleaning of equipment. Transmission-based precautions add measures for specific suspected or confirmed organisms and routes of spread.
Think of the infection chain as an organism, reservoir, exit route, mode of transmission, entry route and susceptible host. Interrupting a link reduces transmission risk; it does not prove that every exposure has been eliminated. A contaminated glove can carry an organism from a patient to a console, then to another patient's line. Preventing that sequence requires attention to both patient contact and environmental contact.
Hand hygiene and gloves
Clean hands before touching a patient, before an aseptic task, after potential exposure to body fluids, after patient contact and after touching the patient's surroundings. Perform hand hygiene after removing gloves. Gloves can have defects or contaminate hands during removal, and wearing them does not replace hand hygiene.
CDC prefers alcohol-based hand sanitizer in most clinical situations when hands are not visibly soiled. Use soap and water when hands are visibly dirty and as additionally recommended during outbreaks of C. difficile or norovirus. Although alcohol does not reliably kill C. difficile spores, CDC's routine clinical preference for sanitizer does not automatically change for every CDI encounter. Follow the infection-prevention program's organism-specific policy and contact precautions. Avoid a simplified exam rule that sanitizer is always prohibited for every CDI patient.
For soap-and-water cleaning, cover all hand surfaces, rinse and dry thoroughly. For alcohol rub, use enough product to cover the hands and rub until dry. Pay attention to fingertips, thumbs and between fingers. Do not put on gloves over wet sanitizer or top off a partially filled dispenser with a different product. Remove contaminated gloves before handling clean supplies or typing at a console that other staff will use.
Choose PPE for the exposure and organism
Precaution Typical CT workflow implication
Standard Gloves for anticipated blood or body-fluid contact; eye and clothing protection when splash is possible
Contact Gown and gloves as indicated, with attention to contaminated surfaces and transport equipment
Droplet Appropriate mask protection under the organism-specific policy; patient source control during transport when tolerated
Airborne Fit-tested respirator and room/transport arrangements coordinated with infection prevention
Respiratory particles exist across a size continuum; do not use an arbitrary diameter or a fixed distance to claim that transmission is impossible beyond that boundary. An N95 designation describes filtration performance under a test standard, not a hard particle-size cutoff below which particles pass freely. Respirator selection, fit testing and seal checks matter.
For a patient requiring airborne precautions, coordinate transport, patient masking when appropriate, staff protection and room clearance. A CT room is not automatically an airborne infection isolation room. Air clearance depends on ventilation, air changes per hour, mixing and the target removal level. Do not assign one mandatory vacancy time to every scanner room or assume that scheduling all such patients last is the only permissible approach.
Aseptic vascular access and injection
Prepare the site and disinfect access points with the approved agent and required contact time; allow drying as directed. Keep sterile parts sterile. A needle or syringe that has entered a patient's line is contaminated even when there is no visible blood. Replacing the needle does not make the syringe safe for another patient.
Use single-dose containers for one patient as directed. A pharmacy bulk package is not automatically permission to repeatedly draw doses in a busy scanner room; its labeling specifies the environment and conditions of use. Approved multipatient contrast systems have a distinct, cleared design and instructions, including patient-specific components and time limits. Never improvise multipatient use of an ordinary single-use injector set because a check valve is present.
A practical sequence is to prepare clean supplies, perform hand hygiene, use aseptic technique to connect the patient-specific fluid path, inspect and remove air as directed, and avoid contaminating the connector during positioning. If a component becomes contaminated, replace it rather than wiping an inaccessible sterile surface and assuming sterility has been restored.
Cleaning and disinfection
The table, positioning aids and other noncritical surfaces contacting intact skin generally require appropriate cleaning and low-level disinfection, with additional organism-specific measures when needed. First remove visible soil; organic material can impair disinfectant performance. Use a product compatible with the scanner and effective for the intended organism. Keep the surface wet for the product's labeled contact time. Different agents and concentrations have different times; “one minute for every wipe” is not a valid general rule.
For C. difficile environments, follow the facility's sporicidal environmental-disinfection policy. Do not pour bleach into scanner openings or calculate a dilution without knowing the stock concentration and approved procedure. Protect electronics from liquid entry and clean controls that were touched by contaminated hands. An intact positioning cushion can be disinfected; a torn porous cushion may need replacement because contamination cannot be reliably removed.
Sharps, exposure and documentation
Dispose of sharps immediately in a suitable nearby sharps container; do not recap a used needle by hand. Place other waste in the appropriate category under facility and jurisdictional rules. A blood-stained item is not classified by one universal national disposal rule for every setting.
After a needlestick or mucosal exposure, perform immediate first aid, report promptly and follow occupational-health evaluation. Preserve the information needed to assess the exposure without delaying care. Document unusual contamination events and room restrictions so that the next team does not unknowingly reuse compromised equipment. Infection prevention is a chain of ordinary actions whose reliability matters during both routine throughput and emergencies.
References: CDC clinical hand hygiene , CDC infection-control guidance , and the contrast system's cleared instructions for use.