Study guide

6.3 Frame Selection for Prescriptions

ABO NOCE National Opticianry Competency Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Ophthalmic Optics Terminology & Prescriptions

1.1 Ophthalmic Optics Terminology 1.2 Prescription Interpretation & Transposition 1.3 Measurement Systems & Conversions

2 Chapter 2: Lens Characteristics & Calculations

2.1 Lens Characteristics & Powers 2.2 Lens Formulas 2.3 Usable Accommodation & Range of Vision

3 Chapter 3: Prism, Decentration & Vertex Distance

Section 3.1: Prismatic Effects & Prentice's Rule Section 3.2: Decentration & Vertical Imbalance Section 3.3: Vertex Distance Compensation

4 Chapter 4: Ocular Anatomy & Physiology

4.1 Anatomy of the Eye 4.2 Physiology of Vision & Accommodation 4.3 Refractive Errors

5 Chapter 5: Ocular Pathology & Clinical Cues

5.1 Common Ocular Pathologies 5.2 Scope of Practice & Referral Cues 5.3 Visual Acuity & Testing Basics

6 Chapter 6: Frame Anatomy & Styles

6.1 Frame Materials 6.2 Frame Styles & Anatomy 6.3 Frame Selection for Prescriptions

7 Chapter 7: Lens Materials & Designs

7.1 Lens Materials Comparison 7.2 Multifocal & Trifocal Lenses 7.3 Aspheric & Digitally Surfaced Lenses

8 Chapter 8: Progressive Lenses & Coatings

Section 8.1: Progressive Addition Lenses Section 8.2: Lens Coatings Section 8.3: Lens Tints & Photochromics

9 Chapter 9: Specialty Products & Low Vision

9.1 Low Vision Aids 9.2 Safety Eyewear 9.3 Sports & Occupational Eyewear 9.4 Preassembled Eyewear & OTC Readers

10 Chapter 10: Manual Lensmetry

10.1 Lensmeter Operation & Verification 10.2 Verifying Cylinder Axis & Power 10.3 Measuring Prism on the Lensmeter

11 Chapter 11: Optical Measurement Instruments

11.1 Automated Lensmeters & Calibration 11.2 Lens Clock & Base Curves 11.3 Calipers, Thickness Gauges & PD Tools

12 Chapter 12: Dispensing Tools & Vertex Measurement

12.1 Dispensing Hand Tools 12.2 Distometer & Vertex Distance 12.3 Instrument Safety & Calibration

13 Chapter 13: Patient Measurements & History

13.1 Patient History & Needs Analysis 13.2 Measuring Pupillary Distance 13.3 Measuring Segment Height

14 Chapter 14: Frame Fitting & Troubleshooting

Section 14.1: Nosepad & Bridge Adjustments Section 14.2: Temple & Ear Adjustments Section 14.3: Troubleshooting Visual Complaints

15 Chapter 15: Laws, Regulations & Standards

15.1 ANSI Z80.1 Prescription Tolerances 15.2 ANSI Z87.1 & FDA Safety Regulations 15.3 FTC Eyeglass Rule & Professional Ethics 15.4 Universal Precautions, Coding, Insurance & FCLCA

6.3 Frame Selection for Prescriptions

Key Takeaways Explain This Topic AI

Decentration occurs when the patient's pupils do not align with the geometric centers of the frame eyewires, increasing lens thickness and weight.

Individual decentration is calculated as half the difference between the Frame PD (A + DBL) and the patient's Pupillary Distance (PD).

High-minus prescriptions require small, round, plastic frames to minimize and hide edge thickness, while avoiding rectangular shapes with large effective diameters.

High-plus prescriptions benefit from small, round frames and minimal decentration to keep center thickness and magnification to a minimum.

Progressive addition lenses require a frame with a sufficient B measurement (typically at least 28mm) and avoid sloped bottom rims to preserve the near reading zone.

Last updated: July 2026

  • 6.3 Frame Selection for Prescriptions
  • The Optics of Frame Selection

While patients often select frames based on fashion, the optician's primary responsibility is to ensure that the chosen frame is optically compatible with the patient's prescription. A poor frame choice can result in thick, heavy lenses, poor visual performance, and intolerance to the eyewear. The key to successful optical dispensing is understanding how lens shape, frame size, and eye positioning affect the final thickness, weight, and optical clarity of the lenses.

Decentration and Its Optical Consequences

Decentration is the displacement of the optical center of a lens from the geometric center of the frame's eyewire. Ideally, the optical center of the lens must line up directly with the patient's pupil to prevent unwanted prismatic effects.

To calculate the total decentration of a pair of glasses, we must first determine the Frame PD (also called the Frame Center Distance, FCD):

Frame PD = A + DBL

where A is the horizontal lens width and DBL is the distance between lenses (bridge width).

The total decentration is the difference between the Frame PD and the patient's Pupillary Distance (PD) :

Total Decentration = Frame PD - Patient PD

To find the decentration required for each individual lens:

  • Decentration per Eye = (Frame PD - Patient PD) / 2
  • Why Minimizing Decentration Matters

Lens Blank Size: The lab must select a raw lens blank large enough to cover the frame shape after decentering the optical center. Larger decentration requires a larger lens blank.

Lens Thickness: For minus lenses, larger decentration leads to thicker temporal edges. For plus lenses, larger decentration leads to a thicker nasal center.

Weight: Excess thickness directly translates to excess weight, causing the glasses to slide down the nose and cause discomfort.

Aberrations: Looking through the peripheral portions of a highly decentered lens increases chromatic aberration and distortion.

Rule of Thumb: The ideal frame has a Frame PD that is equal to or very close to the patient's PD, resulting in zero or minimal decentration.

High Minus Prescriptions

Minus lenses are thin in the center and thickest at the edges. The power of a minus lens increases toward the periphery, meaning edge thickness increases exponentially with the size of the lens.

Selection Strategies for High Minus (e.g., above -4.00 D)

Choose Small Frame Sizes (A Measurement): Reducing the horizontal lens width from 55mm to 48mm can reduce edge thickness by up to 30%.

Opt for Round or Oval Shapes: Round shapes have a smaller Effective Diameter (ED) compared to rectangular or aviator shapes. Square or rectangular frames have sharp corners that extend far from the center, which catches the thickest, heaviest part of the minus lens.

Select Thick Plastic (Zyl) Frames: Plastic eyewires have a thicker profile than thin metal wires, which helps hide the visible edge of the lens.

Avoid Rimless and Semi-Rimless Styles: The exposed, thick edges of a high-minus lens in a semi-rimless or rimless frame look aesthetically unappealing and are prone to chipping.

High Plus Prescriptions

Plus lenses are thickest in the center and thin at the edges.

Selection Strategies for High Plus (e.g., above +4.00 D)

Choose Small, Round Frames: Plus lenses are surfaced from a blank where the center thickness is determined by the minimum edge thickness at the widest point. A small, round frame allows the lab to use a very small, thin lens blank, minimizing both center thickness and weight.

Minimize Decentration: High decentration in a plus lens results in an excessively thick center, creating a heavy lens that causes a "magnified eye" (bug-eye) effect.

Maintain a Short Vertex Distance: Fitting the frame close to the eye decreases the magnification effect and increases the patient's usable field of view.

Frame Selection for Progressive Lenses

Progressive Addition Lenses (PALs) provide a seamless transition from distance vision (top of the lens) to near vision (bottom of the lens) through an intermediate corridor.

Corridor Depth and the B Measurement

The vertical height of the frame eyewire is known as the B measurement .

Traditional PALs: Require a minimum B measurement of 28mm to 30mm (or a fitting height of at least 18-20mm from the pupil to the bottom rim) to ensure the entire reading zone is not cut off during the lens edging process.

Short-Corridor PALs: Designed for smaller frames, these lenses compress the intermediate zone, allowing fitting heights as low as 14mm to 16mm (with a B measurement of 22-24mm). However, the trade-off is a narrower intermediate corridor and a faster transition, which some patients find difficult to adapt to.

Shape Considerations: Avoid aviator styles or frames with drastically sloped bottom rims. The progressive corridor runs downward and slightly nasal. A sloped bottom-nasal corner will cut off the reading zone.

Prescription-Based Frame Selection Guidelines

Prescription Type Recommended Frame Characteristics Frame Features to Avoid Optical Reason

High Minus (>-4.00 D) Small, round/oval, thick plastic, minimal decentration Large, rectangular/square, rimless, metal frames Hides edge thickness, minimizes lens weight, prevents edge chipping

High Plus (>+4.00 D) Small, round/oval, minimal decentration, short vertex distance Large frames, high decentration, aviator shapes Minimizes center thickness and weight, reduces "bug-eye" magnification

Progressive Lenses (PALs) Adequate B measurement (>28mm), straight bottom rims Sloped bottom rims (aviators), extremely small B measurement Prevents cutting off the near reading zone, provides a comfortable intermediate corridor