Study guide

Section 14.1: Nosepad & Bridge Adjustments

ABO NOCE National Opticianry Competency Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Ophthalmic Optics Terminology & Prescriptions

1.1 Ophthalmic Optics Terminology 1.2 Prescription Interpretation & Transposition 1.3 Measurement Systems & Conversions

2 Chapter 2: Lens Characteristics & Calculations

2.1 Lens Characteristics & Powers 2.2 Lens Formulas 2.3 Usable Accommodation & Range of Vision

3 Chapter 3: Prism, Decentration & Vertex Distance

Section 3.1: Prismatic Effects & Prentice's Rule Section 3.2: Decentration & Vertical Imbalance Section 3.3: Vertex Distance Compensation

4 Chapter 4: Ocular Anatomy & Physiology

4.1 Anatomy of the Eye 4.2 Physiology of Vision & Accommodation 4.3 Refractive Errors

5 Chapter 5: Ocular Pathology & Clinical Cues

5.1 Common Ocular Pathologies 5.2 Scope of Practice & Referral Cues 5.3 Visual Acuity & Testing Basics

6 Chapter 6: Frame Anatomy & Styles

6.1 Frame Materials 6.2 Frame Styles & Anatomy 6.3 Frame Selection for Prescriptions

7 Chapter 7: Lens Materials & Designs

7.1 Lens Materials Comparison 7.2 Multifocal & Trifocal Lenses 7.3 Aspheric & Digitally Surfaced Lenses

8 Chapter 8: Progressive Lenses & Coatings

Section 8.1: Progressive Addition Lenses Section 8.2: Lens Coatings Section 8.3: Lens Tints & Photochromics

9 Chapter 9: Specialty Products & Low Vision

9.1 Low Vision Aids 9.2 Safety Eyewear 9.3 Sports & Occupational Eyewear 9.4 Preassembled Eyewear & OTC Readers

10 Chapter 10: Manual Lensmetry

10.1 Lensmeter Operation & Verification 10.2 Verifying Cylinder Axis & Power 10.3 Measuring Prism on the Lensmeter

11 Chapter 11: Optical Measurement Instruments

11.1 Automated Lensmeters & Calibration 11.2 Lens Clock & Base Curves 11.3 Calipers, Thickness Gauges & PD Tools

12 Chapter 12: Dispensing Tools & Vertex Measurement

12.1 Dispensing Hand Tools 12.2 Distometer & Vertex Distance 12.3 Instrument Safety & Calibration

13 Chapter 13: Patient Measurements & History

13.1 Patient History & Needs Analysis 13.2 Measuring Pupillary Distance 13.3 Measuring Segment Height

14 Chapter 14: Frame Fitting & Troubleshooting

Section 14.1: Nosepad & Bridge Adjustments Section 14.2: Temple & Ear Adjustments Section 14.3: Troubleshooting Visual Complaints

15 Chapter 15: Laws, Regulations & Standards

15.1 ANSI Z80.1 Prescription Tolerances 15.2 ANSI Z87.1 & FDA Safety Regulations 15.3 FTC Eyeglass Rule & Professional Ethics 15.4 Universal Precautions, Coding, Insurance & FCLCA

Section 14.1: Nosepad & Bridge Adjustments

Key Takeaways Explain This Topic AI

The frontal, splay, and flare angles of the nosepads must conform to the nasal anatomy to distribute weight and avoid pressure points.

Widening the nosepads lowers the frame height on the face and decreases the vertex distance.

Narrowing the nosepads raises the frame height on the face and increases the vertex distance.

Bending pad arms downward raises the frame front, while bending them upward lowers it, without changing the vertex distance.

All frame adjustments must be completed prior to taking pupillary distance (PD) or segment height measurements to ensure accuracy.

Last updated: July 2026

Section 14.1: Nosepad & Bridge Adjustments

Quick Summary: Proper nosepad and bridge adjustments are critical for determining the vertical alignment of the frame, the vertex distance, and how comfortably the spectacle weight is distributed across the nasal bridge. Opticians must master the alignment of three primary pad angles—frontal, splay, and flare—and understand how narrowing or widening the pads directly affects frame height and distance from the eyes.

Clinical Overview of Bridge Fitting

Spectacle frames are held on the face at three primary points of contact: the nasal bridge and the two ears. Among these, the bridge is responsible for bearing the majority of the spectacle weight and determining the vertical positioning of the lenses. A poorly fitted bridge causes physical discomfort, skin irritation, and optical misalignment, which can lead to visual fatigue.

When performing a frame fitting, the optician must evaluate the patient's nasal structure. Noses vary significantly in width, slope, and height of the nasal bridge. The primary goal of bridge adjustment is to distribute the weight of the frame over a large surface area of the nose, avoiding concentrated pressure points. A fundamental rule of opticianry is to always adjust and fit the frame to the patient's face before taking any optical measurements , such as pupillary distance (PD) or segment height (seg height). If a frame is measured before fitting, subsequent adjustments to the bridge or nosepads will change the resting position of the lenses, invalidating the measurements.

The Three Nosepad Angles

To achieve a comfortable, slip-free, and pain-free fit, the flat surface of each nosepad must rest completely flat against the nose. This requires the optician to analyze and adjust the nosepads along three separate axes of rotation, corresponding to three primary angles: the frontal angle, the splay angle, and the flare angle. FRONT VIEW TOP VIEW

  • Frontal Angle Splay Angle
  • \\ | /
  • \\ | /
  • [ ] [ ] [ ]
  • Nose Nose
  • 1. Frontal Angle

The frontal angle is the vertical tilt of the nosepads when viewed from the front of the frame. The human nose is narrower at the top and flares outward toward the cheeks, typically creating a slope of approximately 20 degrees from the vertical plane. The nosepads must be rotated so that their vertical inclination matches this slope. If the frontal angle is too vertical (less than 20 degrees) or too flared (greater than 20 degrees), the pad will not rest flat. Instead, either the upper or lower edge of the pad will dig into the nasal tissue, causing redness, indentations, and discomfort.

2. Splay Angle

The splay angle is the horizontal angle of the nosepads when viewed from above, looking down onto the frame. The nose splays outward as it moves from the bridge toward the face. The standard splay angle is between 25 and 30 degrees. Properly adjusting the splay angle ensures that the entire face of the nosepad, from front to back, makes contact with the nose. If the splay angle is too narrow, the back edge of the pad will dig into the nose; if it is too wide, the front edge will dig in. Misalignment here reduces the friction holding the frame, causing the glasses to slide down.

3. Flare Angle

The flare angle (sometimes referred to as the transverse or lateral angle) is the tilt of the nosepad when viewed from the side. It represents the slope of the nose as it projects outward from the forehead to the tip, which typically ranges from 10 to 15 degrees. If the nosepads do not match the flare angle, the top or bottom of the pad will tilt away from the nose, leaving a single sharp edge to support the frame's weight.

Mechanics of Nosepad and Pad Arm Adjustments

Adjustable nosepads are mounted on malleable wire arms called pad arms . These arms are manipulated using specialized pad adjusting pliers , which allow the optician to adjust the position and angle of the pads without scratching the frame or tearing the soft silicone pads.

Narrowing vs. Widening Nosepads

The distance between the two nosepads is the primary adjustment used to alter the frame's vertical height and distance from the eyes ( vertex distance ):

Widening the Nosepads (Spreading) : Spreading the nosepads farther apart increases the bridge opening. This allows the frame to slide lower on the patient's nose. Consequently, widening the nosepads lowers the frame vertically on the face and decreases the vertex distance (moving the lenses closer to the eyes).

Narrowing the Nosepads : Squeezing the nosepads closer together reduces the bridge opening. This prevents the frame from sliding down, causing it to ride higher on the nose. Narrowing the nosepads raises the frame vertically and increases the vertex distance (moving the lenses farther from the eyes).

Vertical Pad Arm Shifts

Sometimes, an optician needs to change the vertical height of a frame without altering the vertex distance. This is done by bending both pad arms vertically relative to the frame front:

Bending both pad arms downward pushes the frame front upward , raising the glasses on the patient's face.

Bending both pad arms upward allows the frame front to drop downward , lowering the glasses on the face.

Lateral Shifting and Vertex Distance Adjustments

If a frame is off-center (e.g., sitting too far to the patient's left), both pad arms must be adjusted in the same direction to shift the frame:

To shift the frame to the patient's right, the optician bends both pad arms toward the patient's right.

To adjust vertex distance independently of height, the optician can bend both pad arms closer to the frame front (decreasing vertex distance) or push them farther back from the frame front (increasing vertex distance).

Bridge Types and Material Considerations

Frame materials and bridge designs dictate how adjustments are executed:

Metal Frames : Usually feature adjustable nosepads mounted on pad arms. Nosepads are available in various materials, such as silicone (high friction, prevents slipping, soft on skin) and acetate (hard plastic, durable, slides on/off easily). Mountings are typically screw-on, snap-on, or slide-on.

Plastic (Cellulose Acetate) Frames : Standard plastic frames have fixed, molded bridges. The fit of a zyl frame relies on selecting a frame during dispensing that matches the patient's nose. Zyl bridges include the saddle bridge , which spreads weight uniformly across the top and sides of the nose, and the keyhole bridge , which flares outward at the top, touching only the sides of the nose. If a plastic frame sits too low, opticians can insert adhesive silicone nosepads or retrofit the frame by drilling and installing metal pad arms.

Nosepad Adjustment Effect Matrix

The following matrix summarizes how specific pad and pad arm adjustments alter the vertical position of the frame and the vertex distance:

  • Pad Arm Adjustment Vertical Frame Position Vertex Distance Effect Primary Clinical Use
  • Narrow Nosepads Raises the frame Increases vertex distance Frame sits too low; eyelashes touching lenses
  • Widen Nosepads Lowers the frame Decreases vertex distance Frame sits too high; vertex distance too long
  • Bend Pad Arms Down Raises the frame No change Frame sits too low; vertex distance is correct
  • Bend Pad Arms Up Lowers the frame No change Frame sits too high; vertex distance is correct
  • Bend Pad Arms Back No change Decreases vertex distance Eyelashes clear, but field of view is narrow
  • Bend Pad Arms Forward No change Increases vertex distance Eyelashes are touching the lenses
  • Shift Both Arms Right Shifts frame right No change Corrects horizontal frame misalignment