1.4 Oxygen Delivery Devices & Ventilation
NREMT EMT Certification Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction: NREMT EMT Exam Overview
NREMT EMT Certification Exam Overview NREMT Certification Process Study Strategies & Test-Taking Tips Content Domains & Weight Distribution Eligibility & Registration Career Paths After EMT Certification
2 Chapter 1: Airway, Respiration & Ventilation
1.1 Upper Airway Anatomy & Assessment 1.2 Lower Airway Anatomy & Physiology 1.3 Airway Obstruction Management 1.4 Oxygen Delivery Devices & Ventilation 1.5 Pediatric Airway Considerations
3 Chapter 2: Cardiology & Resuscitation
2.1 Cardiovascular Anatomy & Physiology 2.2 Cardiac Emergencies & Chest Pain Assessment 2.3 CPR & AED Use 2.4 Shock Recognition & Management 2.5 Cardiac Arrest Management
4 Chapter 3: Trauma
3.1 Mechanism of Injury & Scene Assessment 3.2 Bleeding Control & Wound Management 3.3 Musculoskeletal Injuries 3.4 Head, Spine & Chest Injuries 3.5 Burns & Environmental Trauma
5 Chapter 4: Medical, OB/GYN & Special Populations
4.1 Respiratory Emergencies 4.2 Neurological Emergencies 4.3 Allergic Reactions & Anaphylaxis 4.4 Poisoning, Overdose & Environmental Emergencies 4.5 Obstetric & Gynecological Emergencies 4.6 Pediatric Emergencies 4.7 Geriatric Considerations
6 Chapter 5: EMS Operations
5.1 Scene Safety & Hazmat Awareness 5.2 Documentation & Communication 5.3 Legal, Ethical & HIPAA Considerations 5.4 Responder Health & Infection Control
1.4 Oxygen Delivery Devices & Ventilation
Key Takeaways Explain This Topic AI
Nasal cannula delivers 24-44% oxygen at flow rates of 1-6 liters per minute (LPM).
Non-rebreather mask (NRB) delivers 60-90% oxygen at 10-15 LPM and requires the reservoir bag to be fully inflated before placing on the patient.
A bag-valve mask (BVM) with supplemental oxygen delivers nearly 100% oxygen; without oxygen it delivers approximately 21% (room air).
Two-rescuer BVM ventilation is more effective than one-rescuer because one person can maintain a proper mask seal while the other squeezes the bag.
Oropharyngeal airway (OPA) is used only in unresponsive patients with no gag reflex; sized from corner of the mouth to the earlobe or angle of the jaw.
Nasopharyngeal airway (NPA) can be used in patients with an intact gag reflex; sized from the nostril to the earlobe and contraindicated in suspected basilar skull fracture.
Pulse oximetry target is generally 94% or higher; for COPD patients, target 88-92% to avoid suppressing hypoxic drive.
Suctioning should not exceed 15 seconds in adults to prevent hypoxia; suction on withdrawal only.
Last updated: June 2026
Providing supplemental oxygen and assisting ventilations are core EMT skills. Choosing the right device depends on the patient's condition and oxygen needs.
Oxygen Delivery Devices
- Device Flow Rate (LPM) FiO2 Delivered Indications
- Nasal cannula 1-6 LPM 24-44% Mild hypoxia, patient who cannot tolerate a mask, long-term O2
- Simple face mask 6-10 LPM 35-60% Moderate hypoxia (must run at minimum 6 LPM to prevent CO2 rebreathing)
Non-rebreather mask (NRB) 10-15 LPM 60-90% Severe hypoxia, significant respiratory distress, shock, major trauma
- Bag-valve mask (BVM) 15 LPM (with O2) ~100% Apneic patients, respiratory failure, inadequate breathing
- BVM without oxygen N/A ~21% (room air) Emergency when no oxygen supply is available
- Nasal Cannula
Delivers low-flow oxygen at 1-6 LPM.
Each liter per minute increases FiO2 by approximately 4% above room air (21%).
Comfortable for the patient and allows eating and speaking.
Not appropriate for patients who are mouth-breathing exclusively.
Non-Rebreather Mask (NRB)
The reservoir bag must be fully inflated before placing the mask on the patient.
Run at 10-15 LPM to keep the reservoir bag inflated during inhalation.
One-way valves on the mask prevent the patient from rebreathing exhaled CO2.
Highest concentration of oxygen an EMT can deliver without assisting ventilations.
Bag-Valve Mask (BVM)
The BVM is the EMT's primary tool for assisting ventilations :
Connected to supplemental O2 at 15 LPM, it delivers close to 100% oxygen.
Without supplemental oxygen, it delivers approximately 21% (room air).
One-Rescuer BVM Technique:
Position yourself at the head of the patient.
Select the appropriate mask size.
Use the C-E clamp technique: form a "C" with thumb and index finger over the mask and an "E" with the remaining three fingers under the jaw.
Squeeze the bag to deliver approximately 500-600 mL per breath over 1 second.
Watch for visible chest rise — do NOT overventilate.
Two-Rescuer BVM Technique (preferred):
One rescuer holds the mask with both hands using bilateral C-E clamp technique for a better seal.
The second rescuer squeezes the bag.
This method provides a superior mask seal and more consistent ventilations.
- Airway Adjuncts
- Oropharyngeal Airway (OPA)
Purpose: Prevents the tongue from obstructing the airway in unconscious patients.
Sizing: Measure from the corner of the mouth to the earlobe (or angle of the jaw).
Insertion in adults: Insert with the tip pointing toward the roof of the mouth (upside down), then rotate 180 degrees as it passes over the tongue.
Insertion in children: Insert with the tip pointed toward the tongue (right-side up) using a tongue depressor to hold the tongue down. Do NOT rotate — risk of trauma to the soft palate.
Contraindication: Patients with a gag reflex. If the patient gags during insertion, remove it immediately.
Nasopharyngeal Airway (NPA)
Purpose: Maintains airway patency; can be used in patients with or without a gag reflex.
Sizing: Measure from the nostril to the earlobe (or tip of the nose to the earlobe).
Insertion: Lubricate with a water-soluble lubricant, insert into the right nostril (or larger nostril) with the bevel toward the septum, and advance gently along the floor of the nasal cavity.
Contraindication: Suspected basilar skull fracture (signs include raccoon eyes, Battle's sign, or cerebrospinal fluid leaking from nose/ears).
Pulse Oximetry
Pulse oximetry (SpO2) measures the percentage of hemoglobin saturated with oxygen:
- Normal SpO2: 95-100%
- General target: Maintain SpO2 at 94% or above
COPD patients: Target 88-92% — these patients may rely on a hypoxic drive for breathing, and excessive oxygen can suppress their respiratory drive
Limitations: Pulse oximetry may be inaccurate in hypothermia, carbon monoxide poisoning, poor perfusion, nail polish, and anemia
Suctioning
Suctioning removes blood, vomitus, secretions, and other fluids from the airway.
- Key Suctioning Rules
- Maximum suction time: 15 seconds in adults, 10 seconds in children, 5 seconds in infants
- Suction on withdrawal only (not while inserting the catheter)
- Preoxygenate the patient before suctioning if possible
- Use a rigid (Yankauer) catheter for the oropharynx
- Use a flexible (French) catheter for the nasopharynx and through airway adjuncts
- If the patient has copious secretions requiring repeated suctioning, ventilate between each attempt
Matching the Device to the Patient
Choosing an oxygen device is a clinical decision. The guiding rule: passive devices (cannula, simple mask, non-rebreather) help a patient breathing adequately on their own; a patient breathing inadequately or not at all needs a BVM to move air for them. A non-rebreather cannot rescue a patient whose tidal volume or rate is too low. When you see shallow depth, an abnormal rate with poor quality, declining mental status, or cyanosis despite oxygen, escalate to assisted ventilation with the BVM .
Common Ventilation Errors
Overventilation — too hard, too fast, or too much volume raises intrathoracic pressure, reduces venous return, and forces air into the stomach ( gastric distension ), raising aspiration risk. Deliver just enough to make the chest visibly rise , over 1 second per breath.
Poor mask seal — the most common reason ventilation fails; the two-rescuer technique (one holds a two-handed seal, the other ventilates) is preferred whenever staffing allows.
Wrong rate — for a non-breathing patient with a pulse, ventilate about every 5-6 seconds for adults and every 3-5 seconds for infants and children, reassessing the pulse regularly.
Carbon Monoxide and the Pulse Oximeter Trap
A standard pulse oximeter cannot distinguish oxygen from carbon monoxide on hemoglobin, so a carbon monoxide poisoning patient may show a falsely normal SpO2 while being dangerously hypoxic. Patients from a fire, enclosed running engine, or faulty furnace should receive high-flow oxygen via non-rebreather regardless of the SpO2 reading .