Study guide

9.1 Applying Quality Assurance Techniques in Sport Science Data Collection

NSCA Certified Performance and Sport Scientist CPSS

Track your progress as you read

Finished sections get a check mark.

1 Introduction: CPSS Exam Overview, Eligibility, and Case-Study Strategy

1.1 CPSS Exam Format, Eligibility Pathways, and the 2026 Blueprint 1.2 Mastering Athlete Case Studies and Research Review Scenarios

2 Chapter 1: Scientific Process, Adaptation Theory, and Periodization (Domain 1)

2.1 Training Principles, Adaptation Models, and Injury-Risk Mitigation 2.2 Evaluating Performance Programs Using the Scientific Process 2.3 Periodization Paradigms, Fitness-Fatigue Models, and Tapering

3 Chapter 2: Scientific Disciplines in Athlete Preparation (Domain 1)

3.1 Exercise Physiology, Bioenergetics, and Systemic Adaptations 3.2 Applied Biomechanics, Force-Time Kinetics, and Force-Velocity Profiling 3.3 Motor Learning, Skill Acquisition, and Constraints-Led Practice Design 3.4 Performance Nutrition, Recovery Modalities, and Sport Psychology

4 Chapter 3: Technology Review, Research Appraisal, and Knowledge Translation (Domain 1)

4.1 Critically Reviewing Sport Performance Products, Technologies, and Trends 4.2 Evaluating Research Studies: Design, Validity, and Practical Relevance 4.3 Communicating Research Findings to Support Evidence-Based Practice

5 Chapter 4: Sport Demands Analysis, KPIs, and Resource Strategy (Domain 2)

5.1 Researching Biomechanical, Tactical, and Technical Sport Demands 5.2 Physiological Demands, Injury Epidemiology, and Environmental Constraints 5.3 Qualitative and Mixed-Methods Research for Sport Demands Analysis 5.4 Collaborating with Stakeholders to Establish Key Performance Indicators 5.5 Identifying Resources and Strategies for Short- and Long-Term Goals

6 Chapter 5: Profiling Benchmarks and Needs Analysis Communication (Domain 2)

6.1 Developing Normative Benchmarks: Z-Scores, T-Scores, and Percentiles 6.2 Multidimensional Athlete Profiling and Return-to-Performance Milestones 6.3 Communicating Needs Analysis Results to Multidisciplinary Stakeholders

7 Chapter 6: Assessment Ethics, Safety Standards, and Tool Psychometrics (Domain 3)

7.1 Ethical, Legal, and Privacy Considerations in Athlete Data Collection 7.2 Evaluating Assessment Environments, Equipment, and Safety Standards 7.3 Validity, Reliability (ICC, CV%, TE), and Smallest Worthwhile Change

8 Chapter 7: Applied Assessment and Load-Monitoring Systems (Domain 3)

8.1 Movement Tracking Systems: GNSS/GPS, LPS, IMUs, and Optical Tracking 8.2 Neuromuscular Testing: Force Platforms, Isometric Pulls/Pushes, and VBT 8.3 Internal Load, Autonomic Readiness (HRV), Biomarkers, and PROMs

9 Chapter 8: Quality Assurance, Protocols, and Assessment Efficacy (Domain 3)

9.1 Applying Quality Assurance Techniques in Sport Science Data Collection 9.2 Developing, Documenting, and Standardizing Data Collection Protocols 9.3 Systematically Reevaluating Assessments, Protocols, and Interventions

10 Chapter 9: Data Governance, Storage Architecture, and Cleaning (Domain 4)

10.1 Data Privacy, Security Protocols, and Protecting Organizational Information 10.2 Designing Plans for Data Collection, Storage, Analysis, and AMS Workflows 10.3 Evaluating Data Quality, Signal Integrity, Outliers, and Cleaning Procedures

11 Chapter 10: Statistical Modeling, Feedback Delivery, and Analytical Limitations (Domain 4)

11.1 Inferential Statistics, Correlation, Regression, ANOVA, and Effect Sizes 11.2 Longitudinal Load Modeling: ACWR, EWMA, Monotony, Strain, and Change Detection 11.3 Data Visualization, Dashboard Design, and Timely Stakeholder Feedback 11.4 Communicating Analytical Limitations, Bias, and Uncertainty

9.1 Applying Quality Assurance Techniques in Sport Science Data Collection

Key Takeaways Explain This Topic AI

Force platforms require unloaded zeroing (tare) prior to every individual athlete trial to eliminate piezoelectric charge decay or strain-gauge thermal drift, plus an undisturbed 1.0–2.0 s quiet weighing phase before movement initiation.

Open-circuit metabolic carts require a three-part pre-test calibration: ambient environmental entry (barometric pressure, temperature, relative humidity), 3.00 L syringe flow-volume linearity verification across 0.5–8.0 L/s (within ±1.0%), and two-point gas analyzer calibration (e.g., 16.00% O2 and 4.00% CO2 vs. ambient air at 20.93% O2 and 0.03–0.04% CO2).

ISAK anthropometric quality assurance mandates Harpenden caliper jaw spring tension of 10.0 g/mm² and intra-tester Technical Error of Measurement (TEM) of ≤5.0% for skinfolds and ≤1.0% for girths and bone breadths.

Circadian rhythm causes core temperature, nerve conduction velocity, and maximal neuromuscular power to peak in the late afternoon (16:00–19:00, roughly 3–8% above morning values), whereas serum cortisol and testosterone peak shortly after morning awakening (07:00–09:00).

Pre-test dehydration (USG ≥ 1.020) reduces extracellular fluid volume and increases electrical impedance during Bioelectrical Impedance Analysis (BIA), artificially underestimating fat-free mass and overestimating body fat percentage.

Last updated: October 2026

Applying Quality Assurance Techniques in Sport Science Data Collection

High-precision sport science modeling is futile if the underlying raw measurements are corrupted by instrument drift, biological confounding, or improper trial execution. Quality Assurance (QA) encompasses the systematic pre-session hardware calibrations and environmental controls established before testing begins, whereas Quality Control (QC) refers to the real-time operational checks and trial acceptance criteria enforced during data acquisition to guarantee valid, repeatable observations.

Pre-Session Metrological Calibration and Zeroing Procedures

Every measurement sensor translates a physical phenomenon (force, gas fraction, optical refraction, X-ray attenuation, or electrical impedance) into an electrical voltage. Over time and across changing ambient conditions, this voltage-to-unit transfer function drifts. Rigorous metrological calibration anchors the sensor back to certified physical standards.

1. Force Platforms (Piezoelectric and Strain-Gauge Systems)

Force plates rely on either piezoelectric quartz crystals (which generate an electrical charge proportional to applied mechanical stress) or strain-gauge load cells (which change electrical resistance under mechanical deformation).

Pre-Trial Unloaded Zeroing (Tare): Piezoelectric sensors experience continuous charge decay through their charge amplifiers, while strain gauges exhibit thermal drift as ambient room or floor temperature fluctuates. Consequently, the force platform must be completely unloaded and software-zeroed ( tared ) immediately prior to every individual athlete trial .

Quiet Weighing Phase Verification: Once the athlete steps onto the zeroed plates, the practitioner must enforce a completely motionless 1.0 – 2.0 s 1.0\text{–}2.0\text{ s} 1.0 – 2.0 s quiet standing phase before initiating a Countermovement Jump ( CMJ \text{CMJ} CMJ ) or Squat Jump ( SJ \text{SJ} SJ ). Because forward numerical integration ( v ( t ) = ∫ F net ( t ) − m g m d t v(t) = \int \frac{F_{\text{net}}(t) - mg}{m}\,dt v ( t ) = ∫ m F net ​ ( t ) − m g ​ d t ) uses this initial window to calculate exact system mass ( m = F ˉ z g m = \frac{\bar{F}_z}{g} m = g F ˉ z ​ ​ ), even a ± 15 N \pm 15\text{ N} ± 15 N postural sway during the weighing phase introduces a cumulative velocity integration drift that severely distorts concentric impulse and jump height.

Periodic Static Linearity and Center of Pressure ( CoP \text{CoP} CoP ) Audits: Monthly or quarterly, staff should perform a multi-point static deadweight calibration across the functional range ( 200 N 200\text{ N} 200 N to 5000 N 5000\text{ N} 5000 N ) using certified NIST-traceable masses (verifying linearity error ≤ ± 0.5 – 1.0 % \le \pm 0.5\text{–}1.0\% ≤ ± 0.5 – 1.0% ), inspect inter-axis crosstalk ( F x , F y F_x, F_y F x ​ , F y ​ bleed into F z F_z F z ​ ), and verify spatial Center of Pressure ( CoP \text{CoP} CoP ) accuracy across a 9-point surface grid using a calibrated point-loading rod (acceptable spatial error ≤ ± 2.0 mm \le \pm 2.0\text{ mm} ≤ ± 2.0 mm ).

2. Metabolic Carts (Open-Circuit Indirect Calorimetry)

Indirect calorimetry calculates oxygen uptake ( V ˙ O 2 \dot{V}\text{O}_2 V ˙ O 2 ​ ) and carbon dioxide production ( V ˙ CO 2 \dot{V}\text{CO}_2 V ˙ CO 2 ​ ) via the Haldane transformation by multiplying expired minute ventilation ( V ˙ E \dot{V}_E V ˙ E ​ ) by the difference between inspired and expired gas fractions. Because errors in flow and gas concentration multiply together, a metabolic cart requires a mandatory three-part calibration after the manufacturer-specified electronic warm-up (often about 30 min 30\text{ min} 30 min ):

Ambient Environmental Calibration: Enter verified local barometric pressure ( P B P_B P B ​ ) from a calibrated barometer, ambient room temperature ( ∘ C ^\circ\text{C} ∘ C ) , and relative humidity ( % RH \%\text{RH} % RH ) . These parameters govern the ideal gas law conversions between ATPS \text{ATPS} ATPS (Ambient Temperature and Pressure, Saturated), BTPS \text{BTPS} BTPS (Body Temperature and Pressure, Saturated, used to express V ˙ E \dot{V}_E V ˙ E ​ ), and STPD \text{STPD} STPD (Standard Temperature and Pressure, Dry: 0 ∘ C 0^\circ\text{C} 0 ∘ C , 760 mmHg 760\text{ mmHg} 760 mmHg , 0 % 0\% 0% humidity, used to express V ˙ O 2 \dot{V}\text{O}_2 V ˙ O 2 ​ and V ˙ CO 2 \dot{V}\text{CO}_2 V ˙ CO 2 ​ ).

Volume and Flow Turbine / Pneumotachograph Calibration: Connect a certified 3.00 L 3.00\text{ L} 3.00 L calibration syringe to the flow sensor and execute 5–10 full strokes across a spectrum of physiological flow rates ( 0.5 to 8.0 L ⋅ s − 1 0.5\text{ to }8.0\text{ L}\cdot\text{s}^{-1} 0.5 to 8.0 L ⋅ s − 1 ) to simulate both resting breathing and maximal exercise hyperpnea. The integrated volume must read within ± 1.0 % \pm 1.0\% ± 1.0% ( 2.97 to 3.03 L 2.97\text{ to }3.03\text{ L} 2.97 to 3.03 L ).

Two-Point Gas Analyzer Calibration: Calibrate the O 2 \text{O}_2 O 2 ​ analyzer (paramagnetic or zirconia fuel cell) and CO 2 \text{CO}_2 CO 2 ​ analyzer (nondispersive infrared) across two known points: (a) uncontaminated ambient room air ( 20.93 % O 2 20.93\%\ \text{O}_2 20.93% O 2 ​ , 0.03 – 0.04 % CO 2 0.03\text{–}0.04\%\ \text{CO}_2 0.03 – 0.04% CO 2 ​ , balance N 2 \text{N}_2 N 2 ​ ), ensuring the sampling line is not drawing exhaled breath from nearby athletes, and (b) a gravimetrically certified span reference gas cylinder (typically 16.00 % O 2 16.00\%\ \text{O}_2 16.00% O 2 ​ , 4.00 % CO 2 4.00\%\ \text{CO}_2 4.00% CO 2 ​ , balance N 2 \text{N}_2 N 2 ​ ). Post-test verification against the reference cylinder must show analyzer drift < ± 0.02 – 0.05 % < \pm 0.02\text{–}0.05\% < ± 0.02 – 0.05% absolute gas fraction.

3. Refractometers, Blood Lactate Analyzers, and Body Composition Instruments

Urine Specific Gravity ( USG \text{USG} USG ) Refractometers: Zero the optical or digital prism before each testing session using distilled or deionized water , verifying an exact baseline reading of 1.000 1.000 1.000 , and wipe the prism completely dry between athlete samples.

Portable Blood Lactate Analyzers: Verify sensor strip accuracy prior to each testing day using manufacturer-supplied low ( 1.0 – 2.0 mmol ⋅ L − 1 1.0\text{–}2.0\text{ mmol}\cdot\text{L}^{-1} 1.0 – 2.0 mmol ⋅ L − 1 ) and high ( 8.0 – 12.0 mmol ⋅ L − 1 8.0\text{–}12.0\text{ mmol}\cdot\text{L}^{-1} 8.0 – 12.0 mmol ⋅ L − 1 ) lactate control solutions and confirm the lot-specific calibration code. During capillary sampling from the earlobe or fingertip, clean the site with alcohol, allow it to dry completely, lance the skin, wipe away the first drop of blood (which is diluted by interstitial fluid and contaminated by eccrine sweat lactate), and draw a free-flowing second drop without forcefully squeezing ("milking") the tissue.

Dual-Energy X-Ray Absorptiometry ( DEXA \text{DEXA} DEXA ): Execute a daily morning QA scan using the manufacturer's anthropomorphic aluminium/hydroxyapatite spine phantom block. Plot the phantom's Bone Mineral Density ( BMD \text{BMD} BMD ) and soft-tissue attenuation on a longitudinal Shewhart/Levey-Jennings control chart; values must remain within ± 1.0 – 1.5 % \pm 1.0\text{–}1.5\% ± 1.0 – 1.5% (or ± 2 SD \pm 2\text{ SD} ± 2 SD ) of the factory reference mean.

ISAK Skinfolds and Anthropometry: Verify Harpenden skinfold caliper jaw spring compression tension at 10.0 g ⋅ mm − 2 10.0\text{ g}\cdot\text{mm}^{-2} 10.0 g ⋅ mm − 2 across the full opening range and check zero closure before each session. Anthropometrists must satisfy International Society for the Advancement of Kinanthropometry (ISAK) Technical Error of Measurement ( TEM \text{TEM} TEM ) benchmarks: post-certification intra-tester TEM ≤ 5.0 % \text{TEM} \le 5.0\% TEM ≤ 5.0% for skinfolds and ≤ 1.0 % \le 1.0\% ≤ 1.0% for girths and bone breadths (Level 2/3 standards; ≤ 7.5 % \le 7.5\% ≤ 7.5% and ≤ 1.5 % \le 1.5\% ≤ 1.5% at Level 1).

Instrument / Modality Pre-Session Calibration Standard Tolerance / Acceptance Criterion Critical Operational Error to Avoid

Force Platforms Unloaded hardware/software tare before every trial; static deadweight & 9-point CoP \text{CoP} CoP grid audit Weighing phase fluctuation < ± 5 N < \pm 5\text{ N} < ± 5 N ; static linearity ≤ ± 1.0 % \le \pm 1.0\% ≤ ± 1.0% ; CoP \text{CoP} CoP error ≤ ± 2.0 mm \le \pm 2.0\text{ mm} ≤ ± 2.0 mm Failing to re-zero between trials or allowing movement during the 1.0 – 2.0 s 1.0\text{–}2.0\text{ s} 1.0 – 2.0 s weighing phase

Metabolic Cart Environmental ( P B , T , % RH P_B, T, \%\text{RH} P B ​ , T , % RH ), 3.00 L 3.00\text{ L} 3.00 L syringe across 0.5 – 8.0 L ⋅ s − 1 0.5\text{–}8.0\text{ L}\cdot\text{s}^{-1} 0.5 – 8.0 L ⋅ s − 1 , 2-point gas ( 20.93 % / 0.03 % 20.93\%/0.03\% 20.93%/0.03% vs. 16.00 % / 4.00 % 16.00\%/4.00\% 16.00%/4.00% ) Syringe volume within ± 1.0 % \pm 1.0\% ± 1.0% ( 2.97 – 3.03 L 2.97\text{–}3.03\text{ L} 2.97 – 3.03 L ); gas analyzer drift < ± 0.03 % < \pm 0.03\% < ± 0.03% Calibrating ambient air in a poorly ventilated room containing elevated exhaled CO 2 \text{CO}_2 CO 2 ​

Refractometer ( USG \text{USG} USG ) Zero-point calibration using distilled or deionized water at room temperature Baseline distilled water reading = 1.000 = 1.000 = 1.000 ; athlete euhydration cutoff < 1.020 < 1.020 < 1.020 Residual water droplets on prism diluting subsequent athlete urine specimen

Blood Lactate Analyzer Low ( 1 – 2 mmol ⋅ L − 1 1\text{–}2\text{ mmol}\cdot\text{L}^{-1} 1 – 2 mmol ⋅ L − 1 ) and High ( 8 – 12 mmol ⋅ L − 1 8\text{–}12\text{ mmol}\cdot\text{L}^{-1} 8 – 12 mmol ⋅ L − 1 ) control solutions & lot code check Control readings within manufacturer target window (typically ± 0.2 – 0.4 mmol ⋅ L − 1 \pm 0.2\text{–}0.4\text{ mmol}\cdot\text{L}^{-1} ± 0.2 – 0.4 mmol ⋅ L − 1 ) Analysing the first blood drop (sweat lactate contamination) or milking the finger (interstitial dilution)

DEXA Scanner Daily morning scan of anthropomorphic hydroxyapatite spine phantom block Phantom BMD \text{BMD} BMD and fat/lean mass within ± 1.0 – 1.5 % \pm 1.0\text{–}1.5\% ± 1.0 – 1.5% ( ± 2 SD \pm 2\text{ SD} ± 2 SD ) on Levey-Jennings chart Scanning athletes post-exercise, dehydrated, or after eating a large meal

ISAK Skinfold Calipers Jaw spring tension verification ( 10.0 g ⋅ mm − 2 10.0\text{ g}\cdot\text{mm}^{-2} 10.0 g ⋅ mm − 2 ) & Vernier scale zero check Intra-tester TEM ≤ 5.0 % \text{TEM} \le 5.0\% TEM ≤ 5.0% (skinfolds) and ≤ 1.0 % \le 1.0\% ≤ 1.0% (breadths/girths) Failing to mark anatomical landmarks or reading caliper before/after the 2 s 2\text{ s} 2 s compression mark

Controlling Biological, Circadian, and Behavioral Pre-Test Variance

Even a perfectly calibrated sensor yields noisy longitudinal data if the athlete's internal physiological state varies between testing sessions.

Circadian Diurnal Variation

Human physiology is governed by an endogenous 24 -hour 24\text{-hour} 24 -hour circadian clock in the hypothalamic suprachiasmatic nucleus:

Neuromuscular and Metabolic Peak ( 16 : 00 – 19 : 00 16:00\text{–}19:00 16 : 00 – 19 : 00 ): Core body temperature rises by ∼ 0.5 – 0.8 ∘ C \sim 0.5\text{–}0.8^\circ\text{C} ∼ 0.5 – 0. 8 ∘ C from early morning to late afternoon, accelerating peripheral nerve conduction velocity, sarcoplasmic reticulum Ca 2 + \text{Ca}^{2+} Ca 2 + kinetics, and actin-myosin cross-bridge cycling. Consequently, isometric peak force, isokinetic torque, CMJ \text{CMJ} CMJ height, and short-sprint performance are 3 – 8 % 3\text{–}8\% 3 – 8% higher in the late afternoon ( 16 : 00 – 19 : 00 16:00\text{–}19:00 16 : 00 – 19 : 00 ) than in the early morning ( 07 : 00 – 09 : 00 07:00\text{–}09:00 07 : 00 – 09 : 00 ).

Endocrine Morning Acrophase ( 07 : 00 – 09 : 00 07:00\text{–}09:00 07 : 00 – 09 : 00 ): Conversely, resting serum cortisol and total/free testosterone peak within 30 – 60 min 30\text{–}60\text{ min} 30 – 60 min of morning awakening and decline through the day: cortisol roughly halves (or more) by late afternoon, while testosterone falls less (often about 20 – 25 % 20\text{–}25\% 20 – 25% ).

Standardization Rule: Longitudinal retests for any given athlete must be scheduled at the exact same time of day ( ± 1 hour \pm 1\text{ hour} ± 1 hour ) .

Prior Exercise, Hydration, Nutrition, and Ergogenic Controls

Prior Exercise Abstinence: Athletes must abstain from heavy eccentric, plyometric, or high-volume training for 24 – 48 hours 24\text{–}48\text{ hours} 24 – 48 hours prior to testing to avoid low-frequency neuromuscular fatigue and delayed-onset muscle soreness.

Hydration Verification and the BIA Impedance Mechanism: Athletes must present in a verified euhydrated state ( USG < 1.020 \text{USG} < 1.020 USG < 1.020 ) before performance or body composition testing. Hydration control is especially critical for Bioelectrical Impedance Analysis ( BIA \text{BIA} BIA ) . BIA \text{BIA} BIA introduces a weak alternating current through the body and measures electrical impedance ( Z = R 2 + X c 2 Z = \sqrt{R^2 + X_c^2} Z = R 2 + X c 2 ​ ​ ) to estimate Total Body Water ( TBW \text{TBW} TBW ), assuming that Fat-Free Mass ( FFM \text{FFM} FFM ) is ∼ 73 % \sim 73\% ∼ 73% water and conducts electricity readily via dissolved electrolytes, whereas adipose tissue is anhydrous and resistive. If an athlete arrives dehydrated (e.g., USG = 1.028 \text{USG} = 1.028 USG = 1.028 after morning practice or fluid restriction), extracellular fluid volume drops and whole-body electrical impedance ( Z Z Z ) increases. The BIA \text{BIA} BIA algorithm interprets higher impedance as lower TBW \text{TBW} TBW and lower FFM \text{FFM} FFM , artificially overestimating body fat percentage ( % BF \%\text{BF} % BF ) by 2 – 4 % 2\text{–}4\% 2 – 4% ! Conversely, acute hyperhydration or post-exercise cutaneous vasodilation and elevated skin temperature lowers electrical impedance, overestimating FFM \text{FFM} FFM and underestimating % BF \%\text{BF} % BF .

Nutritional and Ergogenic Standardization: For DEXA \text{DEXA} DEXA and BIA \text{BIA} BIA , athletes should be tested overnight fasted ( 8 – 12 hours 8\text{–}12\text{ hours} 8 – 12 hours ) , bladder voided, and prior to any exercise. For maximal performance testing, athletes should consume a standardized carbohydrate-rich meal 2 – 3 hours 2\text{–}3\text{ hours} 2 – 3 hours prior and strictly replicate (or abstain from) acute ergogenic aids such as caffeine ( 3 – 6 mg ⋅ kg − 1 3\text{–}6\text{ mg}\cdot\text{kg}^{-1} 3 – 6 mg ⋅ kg − 1 ) , which independently elevates peak power and time-to-exhaustion.

Real-Time Intra-Session Quality Control (Trial Acceptance Criteria)

During testing, the sport scientist must inspect every raw trace or physiological readout immediately and reject invalid trials in real time rather than attempting post-hoc salvage:

Isometric Mid-Thigh Pull ( IMTP \text{IMTP} IMTP ): Inspect the force-time curve before saving. Reject and repeat any trial displaying an unstable pre-trial baseline, an initial downward countermovement unloading dip > 50 N > 50\text{ N} > 50 N prior to force onset, or visible loss of grip/posture.

Squat Jump ( SJ \text{SJ} SJ ): Enforce a motionless 3 s 3\text{ s} 3 s isometric hold at the prescribed 90 ∘ 90^\circ 9 0 ∘ knee angle. Reject any trial exhibiting a downward countermovement dip > 50 N > 50\text{ N} > 50 N before concentric push-off, as even a small stretch-shortening cycle pre-stretch can inflate concentric peak power and jump height.

Countermovement Jump ( CMJ \text{CMJ} CMJ ) and Contact Mats: In hands-on-hips (akimbo) protocols, reject trials where the hands detach from the iliac crests. When using flight-time contact mats or optical beams ( h = 1 8 g t flight 2 h = \frac{1}{8} g t_{\text{flight}}^2 h = 8 1 ​ g t flight 2 ​ ), reject any trial in which the athlete flexes the hips/knees ("tucks") or dorsiflexes the ankles at landing, which artificially prolongs flight time and inflates jump height by a few centimetres.

Maximal Oxygen Uptake ( V ˙ O 2 max ⁡ \dot{V}\text{O}_{2\max} V ˙ O 2 m a x ​ ) Verification Criteria: To confirm that an athlete achieved a true physiological V ˙ O 2 max ⁡ \dot{V}\text{O}_{2\max} V ˙ O 2 m a x ​ rather than a submaximal symptom-limited V ˙ O 2 peak \dot{V}\text{O}_{2\text{peak}} V ˙ O 2 peak ​ , check first for the primary criterion : a V ˙ O 2 \dot{V}\text{O}_2 V ˙ O 2 ​ plateau (an increase in V ˙ O 2 < 150 mL ⋅ min − 1 \dot{V}\text{O}_2 < 150\text{ mL}\cdot\text{min}^{-1} V ˙ O 2 ​ < 150 mL ⋅ min − 1 or < 2.1 mL ⋅ kg − 1 ⋅ min − 1 < 2.1\text{ mL}\cdot\text{kg}^{-1}\cdot\text{min}^{-1} < 2.1 mL ⋅ kg − 1 ⋅ min − 1 despite an increase in external workload). When a plateau is absent, verify attainment of secondary maximal criteria (or administer a supramaximal verification stage at 105 – 110 % 105\text{–}110\% 105 – 110% peak work rate): Respiratory Exchange Ratio ( RER = V ˙ CO 2 V ˙ O 2 ≥ 1.10 – 1.15 \text{RER} = \frac{\dot{V}\text{CO}_2}{\dot{V}\text{O}_2} \ge 1.10\text{–}1.15 RER = V ˙ O 2 ​ V ˙ CO 2 ​ ​ ≥ 1.10 – 1.15 ) , peak heart rate within ± 10 bpm \pm 10\text{ bpm} ± 10 bpm of age-predicted or known individual HR max ⁡ \text{HR}_{\max} HR m a x ​ , post-exercise blood lactate ≥ 8.0 mmol ⋅ L − 1 \ge 8.0\text{ mmol}\cdot\text{L}^{-1} ≥ 8.0 mmol ⋅ L − 1 , and Borg Rating of Perceived Exertion RPE ≥ 18 / 20 \text{RPE} \ge 18/20 RPE ≥ 18/20 (or ≥ 9 / 10 \ge 9/10 ≥ 9/10 on the CR10 scale).