Study guide
1.2 81-Hour Qualifying Education
New York Security or Fire Alarm Installer License Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 81-Hour Qualifying Education 1.3 Application, Fees, and Fingerprints
2 Who Must Be Licensed
2.1 License Required and Exemptions 2.2 Install, Service, Maintain, Assist, and Network 2.3 Master Electrician Waiver 2.4 NYS DOS License versus NYC FDNY and Local Inspection
3 Business Practice, Employees, and Discipline
3.1 Employees, ID Cards, and Fingerprints 3.2 Qualifying Officers, Display, Records, and Advertising 3.3 Discipline, Criminal Bars, and Penalties
4 Standards and Codes
4.1 Standards Organizations 4.2 New York Uniform Fire Prevention and Building Code and the AHJ 4.3 Listed Equipment, Compatibility, and AHJ Approval
5 NEC and Article 760
5.1 NEC Overview for Alarm Work 5.2 Power-Limited versus Non-Power-Limited Fire Alarm Circuits 5.3 Fire Alarm Cable Types, Plenums, Risers, and Abandoned Cable
6 Basic Electricity I
6.1 Voltage, Current, Resistance, and Ohm’s Law 6.2 Series and Parallel Circuits 6.3 Power, Energy, and Watt’s Law
7 Basic Electricity II
7.1 AC, DC, Transformers, and Low-Voltage Power Supplies 7.2 Batteries for Alarm Systems 7.3 Meters, Opens, Shorts, and Ground Faults
8 Control Devices
8.1 Control Panel Functions and Architecture 8.2 Conventional Zones and IDCs 8.3 Addressable Systems and Signaling Line Circuits
9 Circuits, Battery Calculations, and Job Planning
9.1 Notification Appliance Circuits and Circuit Classes 9.2 Secondary Power and Battery Calculations 9.3 Job Planning and Record Keeping
10 Alarm Transmission
10.1 Digital Alarm Communicators and Legacy Phone Paths 10.2 IP, Cellular, and Dual-Path Communications 10.3 Central Stations, Signal Types, and Path Supervision
11 Motion Detection
11.1 Passive Infrared Motion Detection 11.2 Microwave, Ultrasonic, and Dual-Technology Sensors 11.3 Placement, Pet Immunity, Masking, and Walk-Test
12 Perimeter, Video, Access Control, and False Alarms
12.1 Perimeter Systems 12.2 CCTV / Video Surveillance and Specialty Systems 12.3 Access Control 12.4 False Alarm Prevention
13 Fire Detection Devices
13.1 Fire Behavior and Detector Application 13.2 Smoke Detection 13.3 Heat Detection
14 Other Initiating Devices and Notification
14.1 Manual Stations, Waterflow, Supervisory, Duct, and CO 14.2 Horns, Strobes, Speakers, and Candela 14.3 Notification Placement, Public Mode, and Accessibility
15 Fire Alarm Systems
15.1 System Types and Occupancy Context 15.2 Pathways, Classes, and Survivability 15.3 Elevator Recall, HVAC Shutdown, Door Release, and Suppression Release
16 Job Safety and Professional Conduct
16.1 Job Safety 16.2 Overview and Professional Conduct 16.3 Service Role versus Installation Role
17 Testing and Inspection
17.1 Acceptance Testing and Commissioning 17.2 Periodic Inspection, Testing, and Maintenance Frequencies 17.3 ITM Documentation and Records
18 Troubleshooting and Device Service
18.1 Testing and Troubleshooting Methods 18.2 Panels, Alarm Devices, and Communications Service 18.3 Specialty Service Items
19 Maintenance, Programming, and False-Alarm Reporting
19.1 Maintenance Programs and Contracts 19.2 Maintenance, Inspection, and False Alarm Reporting 19.3 Programming, Access Codes, Bypass, and Hours of Operation
1.2 81-Hour Qualifying Education
Key Takeaways Explain This Topic AI
Qualifying education is four 15-hour modules plus one 21-hour module, for 81 hours, and the applicant must pass the final examination for each module.
19 NYCRR 196.11 requires a 70 percent mark on each approved-course final; that percentage is the school final, not a published Department of State written-exam score.
19 NYCRR 196.10 requires physical attendance of 12 of 15 hours in Modules 1–4 and 18 of 21 hours in Module 5, exclusive of sessions devoted to examinations.
The Department of State currently states there are no continuing education requirements for the Security or Fire Alarm Installer license.
Proof of the approved course must be an original completion certificate for each module; provider approval is issued annually and should be verified before tuition is paid.
Last updated: September 2026
The 81-hour qualifying course is not optional homework for a typical 2026 Path A applicant. The Department of State requires completion of the prescribed modules and a passing score on each module final before the school may certify you. ExamFinch independent study material that helps candidates prepare for the NY DOS Security or Fire Alarm Installer exam treats those modules as the topic map for the walk-in written exam, because the bulletin says the state paper is based on the 81-hour prelicensing curriculum.
Why the hour rules are testable
Title 19 of the New York Codes, Rules and Regulations (NYCRR) Part 196 is the course-approval part. Section 196.10 sets attendance. Section 196.11 sets the 70 percent module-final mark. Schools cannot hand you a final if you have not met attendance. DOS will not treat a photocopy as a substitute when the application calls for an original certificate. Those are licensing facts, not classroom courtesy.
There are no continuing education requirements at this time, according to DOS. That sentence surprises electricians who hold other New York credentials that require biennial hours. For this license, the education fight is the initial 81 hours and the five module finals, not a later continuing-education cycle—unless DOS later changes the rule.
The five-module package
Applicants satisfy education by completing four 15-hour modules and one 21-hour module :
- Module Official title Classroom hours Minimum attendance exclusive of exam sessions
- 1 Installations: Standards, Codes and Techniques 15 12 hours
- 2 Control Panels and Alarm Transmissions 15 12 hours
- 3 Security Systems 15 12 hours
- 4 Fire Technology 15 12 hours
- 5 Service and Maintenance of Alarm Systems 21 18 hours
Those hours add to 81 . Module 5 is the long module because service, inspection, troubleshooting, and maintenance occupy more of a working installer's week than any single installation topic.
19 NYCRR 196.10(a) states that to complete any course, a person must physically attend 12 hours of each 15-hour offering and 18 hours of each 21-hour offering, exclusive of sessions devoted to examinations . Final examinations may not be presented to students who have not completed the attendance requirements. On a 15-hour module you may miss 3 instructional hours (15 − 12). On Module 5 you may miss 3 instructional hours (21 − 18). Missing a four-hour Saturday block on a 15-hour module drops you to 11 attended hours, which is below 12, so the school may not give the final.
A common trap is to read "12 of 15" as permission to skip the exam session or to treat exam time as part of the 12 hours. Exam sessions do not count toward the 12 or the 18. You need the instructional minimum plus the written module final.
19 NYCRR 196.11 requires that all final examinations be written and presented within a reasonable time after the course work, and that a mark of 70% be achieved. That 70 percent is the approved-course final. The DOS walk-in written exam is reported only as passed or failed; do not import the school 70 percent onto the state letter, and do not assume a 68 percent school final is "close enough" because DOS does not print a percentage.
You must pass each module final. Passing four modules and failing Module 5 does not produce an 81-hour certificate.
What each module is for
Module 1 — Installations: Standards, Codes and Techniques covers listing and labeling, the New York Uniform Fire Prevention and Building Code, National Fire Protection Association standards as they appear in the state curriculum, and the craft of placing cable and devices correctly.
Module 2 — Control Panels and Alarm Transmissions covers how a panel supervises circuits, how signals leave the premises, and the job-planning content that sits in that module.
Module 3 — Security Systems covers motion detection, perimeter devices, access control, closed-circuit television used in a detection context, and false-alarm awareness.
Module 4 — Fire Technology covers detectors, notification, system types, and the job-safety topics the bulletin later names on the state exam.
Module 5 — Service and Maintenance of Alarm Systems covers testing, troubleshooting, programming awareness, and the service role versus the installation role.
Later chapters in this guide teach those subjects in depth. This section is about proving you took an approved course the way DOS measures it.
Approved providers and original certificates
DOS lists organizations that have submitted coursework and received approval. Course approval is issued on an annual basis. Call the school and, if needed, the Division of Licensing Services at (518) 474-4429 before you pay tuition.
Providers published on the Get a License page at the time of this writing—verify current approval before you enroll—are:
- Electrical Training Center Inc., 65 Elm Street, Copiague, NY 11726, (631) 226-8021
- Firetech Licensing Academy, 1 Blue Hill Plaza, Suite 1509, Pearl River, NY 10965, (845) 445-6224
- Metropolitan Burglar and Fire Alarm Association, 2133 66th Street, Brooklyn, NY 11204, (718) 894-6712
- New York Low Voltage Contractor's Association, Inc., 2133 66th Street, Brooklyn, NY 11204, (718) 894-6712
- Skybridge Restoration Inc., 3262 Steinway Street, 2nd Floor, Astoria, NY 11103, (929) 424-3447
Proof of successful completion must be furnished to DOS by an original certificate at the time of application. Submit all completion certificates. A school email screenshot is not the original certificate.
Out-of-state schooling and older industry courses
DOS may waive the 81-hour New York classroom package if you document an equivalent level of schooling. The application instructions ask for an official transcript or an original certificate from a recognized school, plus an official description of the subject matter, sent with a letter requesting a waiver to the Bureau of Educational Standards, P.O. Box 22001, Albany, NY 12201-2001. Do not assume a weekend class from another state is automatically accepted.
The application also describes credit, in 15- or 21-hour blocks, for certain industry programs that were not approved before January 1, 1993, if the subject matter covers the full field. That is a historical evaluation path, not the default 2026 route. Typical new installers complete the five currently approved modules.
How education sequences with the walk-in exam
Path A takes the exam before the application . Education certificates travel with the application, together with the original PASSED notice. You can sit the walk-in exam after you finish modules, or you can finish remaining modules after a pass as long as every original certificate is in the packet when you apply and the pass notice is still within two years. The clean sequence most schools recommend is: meet attendance, pass all five 70 percent finals, sit the DOS walk-in, then apply. Do not wait until month 23 of a pass notice to discover a missing Module 5 original.
Realistic schoolhouse scenarios
Scenario 1 — The 11-hour trap. A student misses a four-hour Saturday block in Module 3. Remaining attended hours are 11. 19 NYCRR 196.10 requires 12 instructional hours exclusive of the exam. The school may not present the final. Makeup hours must be instructional hours, not "just take the test."
Scenario 2 — Confusing two different scoring systems. A student scores 68 percent on the Module 2 school final and assumes "DOS only mails pass/fail, so 68 is close enough." The 70 percent rule is the course rule. The school cannot certify Module 2 at 68 percent.
Scenario 3 — Photocopy packet. A candidate scans five certificates, prints copies, and mails them with DOS-1587-f-a. DOS asks for original certificates. The application stalls while the two-year exam result and the five-month fingerprint receipt keep aging.
Scenario 4 — Continuing-education myth. A licensed installer from another trade tells a helper that the New York alarm license needs recurring continuing-education hours every two years. DOS currently states there are no continuing education requirements. The helper must still complete the 81-hour initial package.
Scenario 5 — Fire-only seminar. A sprinkler fitter enrolls in a fire-tech seminar that is not a DOS-approved five-module sequence. Module 3 security hours are missing. The written exam still names motion detection, perimeter systems, access control, and closed-circuit television.