Study guide

2.1 License Required and Exemptions

New York Security or Fire Alarm Installer License Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts 1.2 81-Hour Qualifying Education 1.3 Application, Fees, and Fingerprints

2 Who Must Be Licensed

2.1 License Required and Exemptions 2.2 Install, Service, Maintain, Assist, and Network 2.3 Master Electrician Waiver 2.4 NYS DOS License versus NYC FDNY and Local Inspection

3 Business Practice, Employees, and Discipline

3.1 Employees, ID Cards, and Fingerprints 3.2 Qualifying Officers, Display, Records, and Advertising 3.3 Discipline, Criminal Bars, and Penalties

4 Standards and Codes

4.1 Standards Organizations 4.2 New York Uniform Fire Prevention and Building Code and the AHJ 4.3 Listed Equipment, Compatibility, and AHJ Approval

5 NEC and Article 760

5.1 NEC Overview for Alarm Work 5.2 Power-Limited versus Non-Power-Limited Fire Alarm Circuits 5.3 Fire Alarm Cable Types, Plenums, Risers, and Abandoned Cable

6 Basic Electricity I

6.1 Voltage, Current, Resistance, and Ohm’s Law 6.2 Series and Parallel Circuits 6.3 Power, Energy, and Watt’s Law

7 Basic Electricity II

7.1 AC, DC, Transformers, and Low-Voltage Power Supplies 7.2 Batteries for Alarm Systems 7.3 Meters, Opens, Shorts, and Ground Faults

8 Control Devices

8.1 Control Panel Functions and Architecture 8.2 Conventional Zones and IDCs 8.3 Addressable Systems and Signaling Line Circuits

9 Circuits, Battery Calculations, and Job Planning

9.1 Notification Appliance Circuits and Circuit Classes 9.2 Secondary Power and Battery Calculations 9.3 Job Planning and Record Keeping

10 Alarm Transmission

10.1 Digital Alarm Communicators and Legacy Phone Paths 10.2 IP, Cellular, and Dual-Path Communications 10.3 Central Stations, Signal Types, and Path Supervision

11 Motion Detection

11.1 Passive Infrared Motion Detection 11.2 Microwave, Ultrasonic, and Dual-Technology Sensors 11.3 Placement, Pet Immunity, Masking, and Walk-Test

12 Perimeter, Video, Access Control, and False Alarms

12.1 Perimeter Systems 12.2 CCTV / Video Surveillance and Specialty Systems 12.3 Access Control 12.4 False Alarm Prevention

13 Fire Detection Devices

13.1 Fire Behavior and Detector Application 13.2 Smoke Detection 13.3 Heat Detection

14 Other Initiating Devices and Notification

14.1 Manual Stations, Waterflow, Supervisory, Duct, and CO 14.2 Horns, Strobes, Speakers, and Candela 14.3 Notification Placement, Public Mode, and Accessibility

15 Fire Alarm Systems

15.1 System Types and Occupancy Context 15.2 Pathways, Classes, and Survivability 15.3 Elevator Recall, HVAC Shutdown, Door Release, and Suppression Release

16 Job Safety and Professional Conduct

16.1 Job Safety 16.2 Overview and Professional Conduct 16.3 Service Role versus Installation Role

17 Testing and Inspection

17.1 Acceptance Testing and Commissioning 17.2 Periodic Inspection, Testing, and Maintenance Frequencies 17.3 ITM Documentation and Records

18 Troubleshooting and Device Service

18.1 Testing and Troubleshooting Methods 18.2 Panels, Alarm Devices, and Communications Service 18.3 Specialty Service Items

19 Maintenance, Programming, and False-Alarm Reporting

19.1 Maintenance Programs and Contracts 19.2 Maintenance, Inspection, and False Alarm Reporting 19.3 Programming, Access Codes, Bypass, and Hours of Operation

2.1 License Required and Exemptions

Key Takeaways Explain This Topic AI

GBL §69-m has required a New York Department of State Security or Fire Alarm Installer license to engage in the business since October 1, 1992.

A licensee may employ unlicensed individuals only if the licensee issues identification cards in the form prescribed by the Secretary of State.

Exemptions under GBL §69-m(2) and 19 NYCRR 195.2(c) cover motor vehicles, water vessels, and aircraft; single-station battery-operated smoke alarm devices; a property owner or proprietor and their employees on their own property or place of business; sprinkler systems; line-voltage connections to an outlet, junction box, or electrical distribution panel; and a single-door card-access entry system that does not detect or notify of intrusion, break-in, theft, movement, sound, or fire.

A license is required to sell a system when installation will be subcontracted (195.2(a)(2)), for CCTV or video used full-time or part-time to detect or monitor intrusion, break-in, theft, movement, sound, or fire, and for electrical entry systems that detect or notify regardless of the number of entry points (195.2(b)).

Application Path B's 3,500 hours apply only to New York experience obtained from October 1, 1989 through September 30, 1992; that figure is not a current experience minimum for new installers.

Last updated: September 2026

The New York Department of State (DOS) Security or Fire Alarm Installer written exam tests whether you can tell who must hold the statewide license before they advertise, bid, or pull cable. Independent ExamFinch materials for the New York Security or Fire Alarm Installer exam treat this as a General Business Law (GBL) Article 6-D scope question, not a local fire-department credential. Article 6-D and 19 NYCRR Part 195 decide who is in the business, who may employ helpers, and which narrow jobs sit outside the license.

Why Scope Questions Appear on the Written Exam

The 81-hour qualifying curriculum and the closed-book DOS sitting both expect you to apply statutory definitions. A candidate who can terminate a smoke detector still misses a licensing item if they think a sales office that never touches wire is unlicensed, or if they treat a single-station battery smoke alarm the same as a hard-wired system detector. This section uses the January 2023 DOS compilation of Article 6-D and Part 195, together with application DOS-1587-f-a (Rev. 12/24), so the distinctions match the law the exam is built on.

Engaging in the Business: GBL §69-l

Engaging in the business of installing, servicing, or maintaining security or fire alarm systems means holding out or undertaking to install, service, or maintain a security or fire alarm system . The statutory system is one designed to detect intrusion, break-in, movement, sound or fire .

Holding out is not limited to placing devices. Advertising "we install monitored fire alarms," bidding a commercial intrusion job, or signing a consumer agreement to maintain a system are all ways of holding out. Undertaking covers actually performing that work. If the detection purpose is present — intrusion, break-in, movement, sound, or fire — you are inside the Article 6-D definition even when the hardware also serves access control or video.

The detection list is the exam hinge. A locksmith who only hangs a mechanical lock is not, by that act alone, in the alarm business. The same person who sells and programs an electrical entry system that detects or notifies of intrusion is in the business, as 19 NYCRR 195.2(b) confirms for electrical entry systems regardless of how many doors are involved.

License Required Since October 1, 1992: GBL §69-m

GBL §69-m has required a DOS license to engage in this business since October 1, 1992 . That date is a licensing trigger, not an experience formula. Typical 2026 applicants qualify through Path A: the 81-hour course plus the written exam. Application Path B (3,500 hours of New York experience without the exam) is only for hours obtained in New York between October 1, 1989 and September 30, 1992 . Do not treat 3,500 hours as a current minimum for new installers.

A licensee may employ unlicensed individuals to perform the work, but only if the licensee issues identification cards in the form prescribed by the Secretary of State (SOS) . The employees do not become independently licensed by wearing the card. The licensed firm remains the party engaging in the business. Later chapters cover card specifications and fingerprint filing; the scope rule here is that unlicensed help is lawful only under a licensee who issues SOS-prescribed cards.

Work That Still Requires a License

19 NYCRR 195.2 closes several loopholes that show up as distractors.

Selling with a subcontracted install. Under 195.2(a)(2), a person who sells a security or fire alarm system when installation will be subcontracted must still be licensed. The sales office cannot hide behind "we never touch wire."

CCTV and video surveillance. A license is required for closed-circuit television or video surveillance when the system is used full-time or part-time for detection or monitoring of intrusion, break-in, theft, movement, sound, or fire. Once video is used to detect or monitor those events, even part-time, the installer license applies.

Electrical entry systems with detection. 195.2(b) requires a license for electrical entry systems that detect or notify of intrusion, break-in, theft, movement, sound, or fire, regardless of the number of entry points . The single-door exemption below applies only when the card-access system does not detect or notify of those events.

Hard-wired smoke detectors in the installation business. The battery-only exemption does not cover a hard-wired smoke detector installed in the business of installing alarm systems. If you are in that business and you install hard-wired smoke detection, you need the license.

Statutory Exemptions: GBL §69-m(2) and 19 NYCRR 195.2(c)

The exemptions are narrow. Memorize the list; there is no general "small job" exemption.

  • Activity License required? Authority
  • Motor vehicles, water vessels, aircraft alarm work No (exempt) 69-m(2) / 195.2(c)
  • Single-station battery-operated smoke alarm devices No (exempt) 69-m(2) / 195.2(c)
  • Hard-wired smoke detector installed in the alarm business Yes Contrast in 195.2(c)

Property owner or proprietor, and their employees, on their own property or place of business No (exempt) 69-m(2) / 195.2(c)

Sprinkler systems No (exempt from this installer license) 69-m(2) / 195.2(c)

Direct line-voltage connections to an outlet, junction box, or electrical distribution panel No (outside the alarm-system definition) 195.1 / 195.2(c)

Single-door card-access entry that does not detect/notify of intrusion, break-in, theft, movement, sound, or fire No (exempt) 195.2(c)

  • Electrical entry that does detect/notify, any number of doors Yes 195.2(b)
  • CCTV used full- or part-time to detect/monitor those events Yes 195.2
  • Selling a system whose install will be subcontracted Yes 195.2(a)(2)
  • Vehicles, vessels, and aircraft

Alarms installed on motor vehicles, water vessels, and aircraft sit outside Article 6-D. A shop that only outfits car alarms is not, for that work, a DOS security or fire alarm installer. The exemption does not follow the technician: the same person installing a building fire alarm still needs the license for the building work.

Battery smoke versus system smoke

Single-station battery-operated smoke alarm devices are exempt. These are the units that run on batteries and sound locally at that station. The moment the device is a hard-wired smoke detector installed as part of the business of installing alarm systems, the exemption does not apply. Exam items often pair "battery single-station" (exempt) with "hard-wired system detector" (licensed).

Owner and employees on their own property

A property owner or proprietor and their employees may work on their own property or place of business without the DOS installer license. The exemption is location-locked. The hardware-store owner who wires the store's own intrusion system is not, by that act, required to hold the installer license. The same owner who then offers to install a neighbor's system is holding out and needs the license. Employees covered here are employees of that owner or proprietor, not a contractor's traveling crew.

Sprinkler systems

Sprinkler systems are exempt from this installer license. Water-based suppression is not converted into an Article 6-D alarm installation merely because waterflow switches later report to a fire alarm control unit. Connecting those initiating devices to an alarm system is alarm work; the sprinkler piping trade itself is not.

Line-voltage connections

Line-voltage connections to an outlet, junction box, or electrical distribution panel are not treated as part of the alarm-system definition. That work is electrical construction, typically under a municipal electrical license. Low-voltage placement of panels, detectors, and notification appliances remains alarm work. Section 2.2 returns to this boundary in the 195.1 definition.

Single-door card access without detection

A single-door card-access entry system is exempt only when it does not detect or notify of intrusion, break-in, theft, movement, sound, or fire. Add door-forced, door-held, or alarm notification, or expand into a detecting entry system, and 195.2(b) pulls the work back into the license regardless of door count.

Applying the Rule on Exam Day

Walk the fact pattern in order:

Is someone holding out or undertaking to install, service, or maintain?

Is the system for intrusion, break-in, movement, sound, or fire — including CCTV or entry used for those purposes?

Does a listed exemption apply with its exact limits?

If the person is unlicensed help, is there a DOS licensee issuing SOS-prescribed ID cards?

If a sales company closes the contract and a licensed subcontractor lands the devices, 195.2(a)(2) still requires the seller to be licensed. If a facilities employee works only on the employer's own building, the owner exemption can apply. If Path B's 3,500 hours appear in a choice about today's new installer, reject it; those hours are a 1989–1992 New York window, not a current experience floor.