Study guide

6.1 Property Conditions and Environmental Hazards

Ohio Real Estate Salesperson Exam

Track your progress as you read

Finished sections get a check mark.

1 Standalone Coverage Map

Standalone Coverage Map: National and Ohio Topics

2 National Portion: Chapter 1: Real Property Characteristics, Legal Descriptions & Property Use

1.1 Real Property vs. Personal Property 1.2 Physical and Economic Characteristics of Real Property 1.3 Legal Descriptions and Surveys 1.4 Land-Use Controls, Public & Private Restrictions, and Encumbrances

3 National Portion: Chapter 2: Forms of Ownership, Transfer & Recording of Title

2.1 Estates, Ownership Forms, Rights, and Interests 2.2 Deeds, Title Transfer, Title Insurance, and Recording

4 National Portion: Chapter 3: Property Value & Appraisal

3.1 The Concept of Value and Economic Principles 3.2 The Appraisal Process and USPAP Basics 3.3 Valuation Approaches (Sales Comparison, Cost, Income) and BPOs

5 National Portion: Chapter 4: Real Estate Contracts & Agency

4.1 Contract Types and Required Elements 4.2 Contract Performance, Breach, and Enforceability 4.3 Listing and Sales Contracts and Contingencies 4.4 Agency Relationships, Fiduciary Duties, and Disclosure

6 National Portion: Chapter 5: Real Estate Practice (Brokerage, Fair Housing, Risk)

5.1 Broker Responsibilities, Brokerage Agreements, and Compensation 5.2 Federal Fair Housing Law and Protected Classes 5.3 Advertising, Antitrust, and Risk Management

7 National Portion: Chapter 6: Property Disclosures & Environmental Issues

6.1 Property Conditions and Environmental Hazards 6.2 Disclosure Obligations, Stigmatized Property, and Liability

8 National Portion: Chapter 7: Financing & Settlement

7.1 Financing Concepts, Notes, Mortgages, and Deeds of Trust 7.2 Loan Types, Lender Requirements, PMI, and Mortgage Insurance 7.3 Federal Financing Regulations (RESPA, TILA, ECOA, TRID) 7.4 Settlement, Closing Statements, and Prorations

9 National Portion: Chapter 8: Real Estate Math Calculations

8.1 Area, Volume, and Valuation Calculations 8.2 Commission, Financing, and Interest Calculations 8.3 Proration, Transfer Tax, and Investment Math

10 Chapter 1: Ohio Division of Real Estate & Licensing

1.1 Ohio Division of Real Estate & Professional Licensing Overview 1.2 Ohio License Requirements 1.3 Ohio License Types and Broker Supervision 1.4 License Maintenance and Renewal

11 Chapter 2: Ohio Agency Law

2.1 Ohio Agency Relationships Overview 2.2 Dual Agency in Ohio 2.3 Ohio Agency Agreement Requirements 2.4 Commission and Compensation Rules

12 Chapter 3: Ohio Contracts & Property Disclosures

3.1 Ohio Purchase Contracts and Agreements 3.2 Ohio Property Disclosure Requirements 3.3 Trust Account Management 3.4 Ohio Closing Procedures

13 Chapter 4: Ohio Property Law & Special Topics

4.1 Ohio Fair Housing Laws 4.2 Ohio License Law Violations and Discipline 4.3 Ohio Property Rights and Ownership 4.4 Environmental Issues and Special Topics

6.1 Property Conditions and Environmental Hazards

Key Takeaways Explain This Topic AI

Federal lead-based paint disclosure applies to target housing built before 1978: EPA pamphlet, known-hazard disclosure, Lead Warning Statement, and a 10-day inspection opportunity.

Radon EPA action level is 4.0 pCi/L; mitigate above it with sub-slab depressurization and re-test.

Asbestos that is intact and non-friable is usually safest left undisturbed or encapsulated by licensed abatement, not scraped by the licensee.

Mold remediation starts with fixing the moisture source; wetlands are regulated under the Clean Water Act and filling may require a Section 404 permit.

The licensee recognizes and refers to qualified professionals; never diagnose, guarantee a fix, or remove hazards personally.

Last updated: June 2026

Why environmental knowledge is tested

The national exam expects a salesperson to recognize common environmental hazards, know who must act, and avoid practicing outside a license. You are not an inspector, an engineer, or a hazmat contractor. Your job is to recognize a red flag, disclose known material facts, and refer the client to a qualified professional. Memorize each hazard's source, the affected property type, and the federally required action.

A recurring trap: the exam rewards the answer that recommends a professional inspection , not the answer where the licensee personally diagnoses, prices, or guarantees a fix. If an option has you saying "there is no problem" or "I removed it myself," it is almost always wrong.

Keep three distinctions straight as you study: the hazard's source (where it comes from), its trigger date or threshold (such as the 1978 lead cutoff or the 4.0 pCi/L radon level), and the required action (disclose, test, encapsulate, mitigate, or permit). Exam questions usually swap one of these three so you pick a hazard that sounds right but pairs the wrong number or action.

Lead-based paint

Lead-based paint is the most heavily tested hazard because it has its own federal disclosure rule. The Residential Lead-Based Paint Hazard Reduction Act (Title X, 1992) and EPA/HUD regulations apply to most housing built before 1978 , the year residential lead paint was banned.

For target housing built before 1978, the seller or landlord must:

Give buyers/tenants the EPA pamphlet Protect Your Family From Lead in Your Home .

Disclose any known lead hazards and provide any available reports.

Include the Lead Warning Statement and signatures in the contract.

Give purchasers a 10-day period to conduct a lead risk assessment or inspection (the period can be shortened or waived by mutual written agreement).

Worked example: A home built in 1965 sells. The buyer wants the 10-day inspection window. Closing was scheduled in 7 days. The parties may either extend closing or mutually agree in writing to shorten/waive the window. The licensee cannot simply ignore the requirement.

Exemptions include housing built 1978 or later , zero-bedroom units (studios, lofts), housing for the elderly/disabled with no children, and rentals with an inspection finding no lead. Penalties for noncompliance can reach roughly $11,000 or more per violation and treble damages in a private suit.

Asbestos, radon, mold, and wetlands

Use this comparison table to lock in the source and action for each hazard:

Hazard Typical source Risk Required/expected action

Asbestos Insulation, pipe wrap, floor tile, popcorn ceilings (pre-1980s) Lung disease when fibers become airborne (friable) Leave intact if undisturbed; encapsulate or have licensed abatement remove. Do not disturb.

Radon Naturally occurring radioactive gas from soil/rock, enters through foundation #2 cause of lung cancer Test with kit/professional; EPA action level 4.0 pCi/L ; mitigate with sub-slab depressurization fan/venting.

Mold Moisture intrusion, leaks, high humidity Respiratory and allergic effects Fix the moisture source ; clean/remediate; no single federal cleanup standard.

Wetlands Low-lying water-saturated land Development restrictions Federally regulated under the Clean Water Act ; building/filling may need a Section 404 permit (Army Corps of Engineers).

Asbestos rule: intact, non-friable asbestos is often safest left alone. The wrong answer usually has a licensee "scraping the popcorn ceiling" before listing.

Radon math: A basement tests at 5.2 pCi/L. Because that exceeds the EPA action level of 4.0 pCi/L, the EPA recommends mitigation. A common mitigation reduces the reading below 2.0 pCi/L; always re-test after a fan is installed.

Wetlands trap: A buyer plans to fill a marshy back acre to build a garage. The exam answer is to verify whether a Section 404 permit is required before any filling, not to assume private land may be filled freely.

Underground storage tanks, PCBs, CFCs, and groundwater

The exam also tests a cluster of secondary hazards. Underground storage tanks (USTs) for heating oil or fuel can leak and contaminate soil and groundwater; EPA registration and monitoring rules apply, and abandoned tanks are a liability flag on older or rural properties. PCBs (polychlorinated biphenyls) appear in old electrical transformers and fluorescent light ballasts. CFCs (chlorofluorocarbons) relate to older refrigeration and air-conditioning equipment and ozone rules.

Watch for groundwater and well/septic issues on rural transactions: a private well needs potability testing, and a failing septic system is a material condition that affects value and habitability.

Putting it together: the licensee's recognition checklist

When you walk a property, train yourself to flag age and condition cues:

Pre-1978 construction triggers the lead-based paint disclosure rule automatically.

Popcorn ceilings, old floor tile, or pipe wrap in pre-1980s homes suggest possible asbestos; recommend testing before any disturbance.

Musty odor or visible staining suggests moisture and possible mold; recommend the moisture source be found and fixed.

A basement or slab-on-grade home in a radon-prone area warrants a radon test, especially because results above 4.0 pCi/L require mitigation.

Low, wet, or marshy land warrants a wetlands determination before any filling or building.

Cost-of-inaction example: A licensee who fails to recommend a lead inspection on a 1968 home, and the buyer's child is later harmed, exposes both the licensee and seller to civil liability and license discipline. The defensive move is always documentation: note in writing that you recommended a professional inspection and provided the required disclosures.