Study guide
1.1 Oklahoma Electrical License Act & CIB Regulations
Oklahoma Journeyman Electrician Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Oklahoma Licensing Laws, Board Rules & Safety
1.1 Oklahoma Electrical License Act & CIB Regulations 1.2 OK Journeyman Exam Format, PSI Logistics & Codebook Navigation 1.3 OSHA Electrical Safety Standards (29 CFR 1926/1910) 1.4 NFPA 70E Electrical Safety in the Workplace & Arc Flash 1.5 Permits, Inspections, Structural Integrity & Job Estimating 1.6 Oklahoma's Adopted 2023 NEC: OUBCC Amendments You Must Know 1.7 OSHA 29 CFR 1926 Job-Site Safety: Sanitation, Signage, Ladders, Scaffolds & Fall Protection
2 Chapter 2: General Electrical Theory & Calculations
2.1 Ohm's Law, Watt's Law & DC Series/Parallel Circuits 2.2 AC Theory, Reactance, Impedance & Power Factor 2.3 Three-Phase Power Systems (Delta & Wye Configurations) 2.4 Electrical Units, Formulas & Conversions 2.5 Cost of Power in a Circuit, Efficiency & Troubleshooting/Test Instruments
3 Chapter 3: General Installation Requirements (NEC Article 110)
3.1 Examination, Identification, Installation & Use of Equipment (110.3) 3.2 Electrical Connections, Terminations & Torque Requirements (110.14) 3.3 Working Space, Clearances & Guarding of Live Parts (110.26 & 110.27) 3.4 Enclosure Types, Markings & Available Fault Current (110.24 & 110.28) 3.5 Installations Over 600 Volts: Article 110 Part III, Article 490 & Medium-Voltage Cable
4 Chapter 4: Branch Circuits & Feeders (NEC Articles 210, 215 & 225)
4.1 Branch Circuit Ratings, Multiwire Branch Circuits & Identification (210.3–210.10) 4.2 Ground-Fault Circuit-Interrupter (GFCI) Protection (210.8) 4.3 Arc-Fault Circuit-Interrupter (AFCI) Protection & Receptacle Outlets (210.12 & 210.52) 4.4 Outside Branch Circuits and Feeders (Article 225) & Feeder Sizing (Article 215)
5 Chapter 5: Services & Service Equipment (NEC Article 230)
5.1 Service Clearances, Overhead & Underground Service-Drop Requirements (230.9, 230.24 & 230.30) 5.2 Service-Entrance Conductors, Sizing & Installation (230.40–230.54) 5.3 Service Equipment Disconnecting Means, Overcurrent Protection & Emergency Disconnects (230.70–230.95)
6 Chapter 6: Electrical Load Calculations (NEC Article 220)
6.1 General Lighting, Small Appliance & Laundry Loads (NEC 220.41, 220.42, 220.45 & 220.52) 6.2 Standard Dwelling Unit Feeder & Service Calculations (NEC Article 220 Part III) 6.3 Optional Dwelling Unit Feeder & Service Calculations (NEC Article 220 Part IV) 6.4 Commercial & Multi-Family Load Calculations (Cooktops, Dryers, HVAC & Stores)
7 Chapter 7: Overcurrent Protection & Tap Rules (NEC Article 240)
7.1 Overcurrent Protection Fundamentals & Standard Ampere Ratings (240.4 & 240.6) 7.2 Feeder & Branch Circuit Tap Rules (NEC 240.21) 7.3 Ground-Fault Protection of Equipment & Selective Coordination (NEC 240.13, 240.86 & Article 245)
8 Chapter 8: Grounding and Bonding (NEC Article 250)
8.1 General Grounding Principles, System Grounding & Grounded Conductors (NEC 250.4, 250.20 & 250.24) 8.2 Grounding Electrode System & Grounding Electrode Conductor (GEC) Sizing (NEC 250.50, 250.52 & 250.66) 8.3 Equipment Grounding Conductors (EGC) Sizing & Installation (NEC 250.118, 250.120 & 250.122) 8.4 Bonding Requirements, Main/System Bonding Jumpers & Separately Derived Systems (NEC 250.28, 250.30 & 250.102)
9 Chapter 9: Wiring Methods & Materials (NEC Articles 300–314)
9.1 General Requirements for Wiring Methods, Underground Clearances & Firestopping (NEC Article 300) 9.2 Conductor Ampacity Ratings, Temperature Correction & Bundling Adjustments (Article 310 & Table 310.16) 9.3 Nonmetallic-Sheathed Cable (Type NM), Metal-Clad Cable (Type MC) & Armored Cable (Type AC) 9.4 Outlet, Device, Pull & Junction Boxes Sizing and Box Fill Calculations (NEC Article 314) 9.5 Temporary Installations (Article 590), Cranes & Hoists (Article 610), Elevators & Escalators (Article 620)
10 Chapter 10: Raceways, Tubing, Conduit Fill & Underground Systems
10.1 Rigid Metal Conduit (RMC), Intermediate Metal Conduit (IMC) & Electrical Metallic Tubing (EMT) 10.2 Nonmetallic Raceways (PVC, RTRC, Liquidtight) & Cable Trays (NEC Articles 352, 356, 392) 10.3 Conduit Fill Calculations (Chapter 9 Tables 1, 4 & 5, Annex C) & Pull Box Sizing (NEC 314.28)
11 Chapter 11: Motors, Controllers & Air Conditioning (NEC Articles 430 & 440)
11.1 Motor Full-Load Current (FLC), Branch Circuit Conductor Sizing & Disconnects (430.6, 430.22 & 430.102) 11.2 Motor Overload Protection & Motor Branch Circuit Short-Circuit/Ground-Fault Protection (430.32 & 430.52) 11.3 Motor Feeder Conductor Sizing & Feeder Overcurrent Protection (430.24 & 430.62) 11.4 Air Conditioning & Refrigeration Equipment (NEC Article 440: MCA, MOCP & Disconnects)
12 Chapter 12: Transformers & Equipment (NEC Articles 450, 410, 422 & 424)
12.1 Transformer Sizing, Protection & Voltage Calculations (NEC Article 450 & Table 450.3(B)) 12.2 Luminaires, Lampholders & Lamps Installation (NEC Article 410) 12.3 Appliances & Electric Water Heaters (NEC Article 422) 12.4 Fixed Electric Space-Heating Equipment (NEC Article 424) 12.5 Snow-Melting & De-Icing Equipment (Article 426) and Pipeline & Vessel Heating (Article 427) 12.6 Electric Signs & Outline Lighting (Article 600) and Lighting Systems 30 Volts or Less (Article 411)
13 Chapter 13: Special Occupancies & Hazardous Locations (NEC Articles 500–517)
13.1 Hazardous (Classified) Locations: Class I, II, and III (Articles 500, 501, 502 & 503) 13.2 Commercial Garages, Repair Facilities & Fuel Dispensing Facilities (Articles 511 & 514) 13.3 Health Care Facilities: Patient Care Spaces & Wiring Methods (Article 517) 13.4 Agricultural Buildings & Manufactured/Mobile Homes (Articles 547 & 550) 13.5 Bulk Storage Plants (Article 515) and Spray Application, Dipping & Coating (Article 516)
14 Chapter 14: Special Equipment, Swimming Pools & Low-Voltage Systems
14.1 Swimming Pools, Spas, Hot Tubs & Hydromassage Bathtubs (Article 680) 14.2 Emergency Systems, Legally Required & Optional Standby Systems (Articles 700, 701 & 702) 14.3 Class 1, 2, 3 & Class 4 Power-Limited Circuits (NEC Articles 722, 724, 725 & 726) and Fire Alarms (NEC Article 760) 14.4 RV Parks (Article 551), Floating Buildings (Article 553) & Marinas/Docking Facilities (Article 555)
1.1 Oklahoma Electrical License Act & CIB Regulations
Key Takeaways Explain This Topic AI
The Oklahoma Electrical License Act (59 O.S. § 1680 et seq.) and OAC Title 158, Chapter 40 establish state electrical licensing, administered by the Construction Industries Board with the seven-member Committee of Electrical Examiners (59 O.S. § 1683).
OAC 158:40-7-1(b) requires an Unlimited Electrical Journeyman applicant to be at least 18 and to verify 8,000 hours (4 years) of on-the-job experience under a journeyman or contractor while employed by a licensed electrical contractor, with at least 4,000 hours in commercial/industrial work and no more than 2,000 verified classroom hours of formal electrical education counted.
OAC 158:40-5-1(b) and (c) cap supervision at three registered apprentices per licensed journeyman or contractor.
Licenses expire on the last day of the licensee’s birth month (OAC 158:40-9-3(e)); a late fee attaches 30 days after expiration, renewal is possible up to one year from the original renewal date, and a license expired longer than one year cannot be renewed — the former holder must reapply and retest.
Effective January 1, 2026 (HB 3215), journeymen and contractors must complete 12 hours of approved continuing education every 36 months — six of them on OUBCC-adopted code revisions — and the Electrical Hearing Board may impose administrative fines of up to $500 per violation with a $1,000 maximum under 59 O.S. § 1695(B).
Last updated: August 2026
1.1 Oklahoma Electrical License Act & CIB Regulations
In the State of Oklahoma, the installation, alteration, repair, and maintenance of electrical conductors, equipment, and apparatus are governed by statutory law and administrative code designed to safeguard public health, life, and property from electrical hazards. The foundational statutes are codified under the Oklahoma Electrical License Act (Title 59 of the Oklahoma Statutes, Section 1680 et seq.) , and the implementing administrative rules are established under the Oklahoma Administrative Code (OAC) Title 158, Chapter 40 .
Every candidate preparing for the Oklahoma Unlimited Electrical Journeyman Examination must master these administrative rules, statutory definitions, licensing classifications, supervision ratios, and enforcement mechanisms.
1. Statutory Governance: CIB & The Committee of Electrical Examiners
The regulation and enforcement of electrical contracting and journeyman licensing are executed through a tiered administrative structure under the Oklahoma Construction Industries Board (CIB) . +-----------------------------------------------------------------------------+
- | OKLAHOMA ELECTRICAL REGULATORY STRUCTURE |
- | |
- | +-----------------------------------------+ |
- | | CONSTRUCTION INDUSTRIES BOARD | |
- | | (CIB) | |
- | +-----------------------------------------+ |
- | | |
- | +------------------+------------------+ |
- | | | |
- | v v |
- | +-----------------------------+ +-----------------------------+ |
- | | COMMITTEE OF ELECTRICAL | | HEARING BOARD | |
- | | EXAMINERS | | | |
- | | - 7 Members (CIB Appointed)| | - Adjudicates Formal Charges| |
- | | - Examines Qualifications | | - Fines: $500/violation | |
- | | - Formulates Exam Standards| | - Suspends / Revokes License| |
- | | - Recommends Rule Updates | | - Enforces Cease & Desist | |
- | +-----------------------------+ +-----------------------------+ |
- +-----------------------------------------------------------------------------+
- The Construction Industries Board (CIB)
The Construction Industries Board (59 O.S. § 1000.1 et seq.) is the overarching state regulatory agency tasked with licensing, testing, and disciplining the construction trades in Oklahoma, including Electrical, Plumbing, Mechanical, Roofing, and Home Inspection. The CIB maintains the official registry of all licensed contractors, journeymen, and registered apprentices.
The Committee of Electrical Examiners (59 O.S. § 1683)
The Committee of Electrical Examiners serves as the technical authority advising the CIB. It consists of seven (7) members appointed by the CIB:
Members represent diverse sectors of the electrical industry, including licensed electrical contractors (commercial/industrial and residential), licensed electrical journeymen, registered professional electrical engineers, and municipal electrical inspectors.
Primary Powers & Duties:
Review and evaluate examination applications and candidate qualifications.
Develop, maintain, and update licensing examinations in coordination with testing partners (PSI).
Conduct hearings and investigations regarding applicant qualifications and trade competency.
Propose amendments to OAC Title 158, Chapter 40, to align state rules with updated editions of the National Electrical Code (NFPA 70).
The CIB Hearing Board & Disciplinary Authority (59 O.S. § 1689)
When complaints or notices of violation are filed against licensed electricians or unlicensed individuals performing electrical work, the case is referred to the CIB Hearing Board .
The Hearing Board conducts administrative hearings governed by the Oklahoma Administrative Procedures Act (75 O.S. § 250 et seq.).
Enforcement Remedies & Sanctions:
Administrative fines of up to $500.00 for each violation , with the total fine capped at $1,000.00 (59 O.S. § 1695(B)). Each day a person remains in violation may be charged as a separate violation.
Formal reprimand, license probation, suspension, or permanent license revocation.
Issuance of formal Cease and Desist Orders against unlicensed individuals or unbonded contractors.
Injunction proceedings filed in Oklahoma District Courts to halt illegal contracting operations.
2. Licensing Classifications & Scope of Authority
Oklahoma law establishes five primary credential tiers for electrical work under 59 O.S. § 1682 and OAC 158:40-1-2. (Two narrow add-on classifications also exist: the refinery electrical journeyman under OAC 158:40-7-6, restricted to refinery facilities, and the temporary electrical journeyman .)
Credential Classification Scope of Permitted Electrical Work Required Supervisory Authority
Unlimited Electrical Contractor Planning, laying out, designing, bidding, contracting, installing, and supervising all electrical wiring, fixtures, apparatus, and systems of any voltage, amperage, or occupancy classification across commercial, industrial, and residential structures. Autonomous business entity; must hold active $5,000 state surety bond and minimum $50,000 commercial general liability insurance. May employ journeymen and apprentices.
Residential Electrical Contractor Planning, laying out, bidding, contracting, installing, and repairing electrical wiring and apparatus limited to one- and two-family dwelling units in a singularly constructed structure with a maximum of two dwelling units and at least five feet of separation from any other dwelling unit or structure. Apartments, motels, and multi-family townhomes are outside the residential scope (OAC 158:40-7-2(a)). Autonomous business entity within residential scope; requires state surety bond and general liability insurance.
Unlimited Electrical Journeyman Installing, altering, repairing, maintaining, and connecting electrical conductors, apparatus, and equipment for all commercial, industrial, institutional, and residential facilities. Must perform work under the employment and direction of an active licensed Electrical Contractor. May directly supervise up to 3 registered apprentices.
Residential Electrical Journeyman Installing, altering, and repairing electrical wiring and equipment within the same one- and two-family residential scope defined by OAC 158:40-7-2(a); qualification requires 4,000 hours (2 years) of apprentice experience with no more than 1,000 classroom hours credited. Must work under the employment and direction of a licensed Electrical Contractor. Restricted from commercial and industrial jobs.
Electrical Apprentice Assisting licensed journeymen and contractors in performing physical electrical installations, rough-in, wire pulling, and device mounting. Must be registered with the CIB and work under the continuous, direct on-the-job supervision of a licensed journeyman or contractor. Cannot work independently.
3. Experience Prerequisites & Credentialing Criteria
To qualify for the Oklahoma Unlimited Electrical Journeyman Examination, an applicant must document verifiable on-the-job electrical experience to the Committee of Electrical Examiners under OAC 158:40-7-1(b) . (OAC 158:40-5-1 governs apprentice registration and supervision; it is the unlimited electrical license rule at 158:40-7-1 that sets journeyman experience.) +-----------------------------------------------------------------------------+
- | UNLIMITED JOURNEYMAN EXPERIENCE PREREQUISITE MATRIX |
- | |
- | TOTAL EXPERIENCE MANDATE: 8,000 HOURS (Approx. 4 Full Years) |
- | |
- | +-----------------------------------------------------------------------+ |
- | | MANDATORY ON-THE-JOB COMMERCIAL / INDUSTRIAL EXPERIENCE | |
- | | Minimum 4,000 Hours (50% of total) must be verified in commercial, | |
- | | industrial, or institutional electrical installations. | |
- | +-----------------------------------------------------------------------+ |
- | + |
- | +-----------------------------------------------------------------------+ |
- | | REMAINING 4,000 HOURS CAN BE SATISFIED BY: | |
- | | (1) Additional Commercial/Industrial On-the-Job Experience, OR | |
- | | (2) Residential Electrical Installation On-the-Job Experience, OR | |
- | | (3) Formal Electrical Classroom Hours (Capped at 2,000 Hours max) | |
- | +-----------------------------------------------------------------------+ |
- +-----------------------------------------------------------------------------+
Detailed Experience Rules (OAC 158:40-7-1(b)):
Total Hours Requirement: An applicant for the Unlimited Journeyman license must document at least 8,000 hours (or 4 years) of legal electrical work experience under the supervision of a licensed contractor.
Commercial/Industrial Floor: At least 4,000 hours of the 8,000-hour total must consist of commercial and/or industrial electrical work. Pure residential experience alone will never qualify a candidate for the Unlimited Journeyman examination.
Education Credit Cap: OAC 158:40-7-1(b) allows no more than 2,000 verified actual classroom hours of formal electrical education to be counted toward the 8,000-hour requirement. The cap is written in terms of classroom hours , not a generic 50% allowance, and education credit cannot substitute for the mandatory 4,000-hour commercial/industrial field experience. Verifiable military electrical experience is handled separately: OAC 158:40-9-2.1 (with OAC 158:1-3-10) governs acceptance of military education, training, and experience toward licensure, so military service is credited under that rule rather than under the 2,000-hour classroom cap.
Residential Journeyman Experience: Requires a minimum of 4,000 hours (2 years) of verified electrical experience, with up to 1,000 hours allowable for approved formal vocational education credit.
4. Apprentice Registration & On-the-Job Supervision Ratios
Oklahoma law requires every person learning the trade who is not a licensed journeyman or contractor to maintain an active Apprentice Registration with the CIB before touching any electrical wiring or equipment on a job site.
The Mandatory 3:1 Supervision Ratio (OAC 158:40-5-1(b) and (c))
To maintain job site safety and code compliance, Oklahoma enforces a strict numerical cap on apprentice oversight:
Important
Oklahoma Apprentice-to-Journeyman Ratio: No licensed electrical contractor or journeyman shall supervise more than three (3) registered apprentices on any active job site at any time ( 3:1 Ratio ). +-----------------------------------------------------------------------------+
- | OKLAHOMA APPRENTICE SUPERVISION RATIO |
- | |
- | [1 Licensed Journeyman or Contractor] |
- | | |
- | +-----------+-----------+ |
- | | | | |
- | v v v |
- | [Apprentice 1] [Apprentice 2] [Apprentice 3] <--- COMPLIANT (3:1 Max) |
- | |
- | [Apprentice 4] ------------------------------> [VIOLATION OF OAC 158:40] |
- +-----------------------------------------------------------------------------+
- Direct On-the-Job Supervision Defined
Physical Presence: "Direct on-the-job supervision" means the licensed journeyman or contractor is physically present on the same job site premises where the apprentices are actively working and is readily accessible to inspect, direct, and correct the work.
Unsupervised Apprentices Prohibited: An apprentice may never be left alone on a job site to perform electrical installations, rough-in, or wiring terminations without a licensed electrician physically present.
5. License Renewal, Continuing Education & The 1-Year Retest Rule
Maintaining an active Oklahoma electrical license requires adherence to statutory renewal deadlines and mandatory continuing education cycles. +-----------------------------------------------------------------------------+
- | LICENSE LIFECYCLE & RENEWAL FLOW |
- | |
- | [ACTIVE LICENSE ISSUED] |
- | | |
- | v |
- | [ANNUAL BIRTH-MONTH RENEWAL] |
- | - License expires on last day of licensee's birth month annually. |
- | - Must pay renewal fee and maintain active standing. |
- | | |
- | +------------------------------+ |
- | | (If Renewed on Time) | (If Unrenewed / Expired) |
- | v v |
- | [LICENSE STAYS ACTIVE] [GRACE PERIOD (0 - 12 MONTHS)] |
- | - Complete 12 Hours CE per - Late renewal allowed with penalty fee. |
- | 36 months (HB 3215). - Work is ILLEGAL while expired. |
- | | |
- | v (Past 12 Months Expired) |
- | [PERMANENT CANCELLATION] |
- | - License CANNOT be reinstated. |
- | - MUST re-apply and RETAKE PSI EXAM. |
- +-----------------------------------------------------------------------------+
Key Lifecycle Mandates:
Birth-Month Renewal (OAC 158:40-9-3(e)): All licenses and alarm endorsements have a duration of no longer than one year and expire on the last day of the licensee's birth month each year.
Continuing Education (CE) Mandate (OAC 158:40-9-4, as amended by HB 3215):
Effective January 1, 2026 , HB 3215 doubled the requirement: a journeyman or contractor license cannot be renewed unless the licensee completed twelve (12) hours of Committee-approved continuing education in the thirty-six (36) months preceding expiration.
Six of those twelve hours must cover codes and revisions adopted by the OUBCC; the other six may cover electrical theory, NFPA 70E safe work practices, the licensing Act, or CIB trade regulations.
Registered apprentices must complete 3 hours of CE every year as of January 1, 2026, unless they are a student apprentice or enrolled in an approved course.
A licensee is exempt from CE for three (3) years from the date they passed their current licensing exam (OAC 158:40-9-4(a)(5)).
Sixty (60) minutes constitutes one instructional hour, and the training location must be outside the regular workplace or after regular working hours.
The 1-Year (12-Month) Cancellation / Retest Rule (OAC 158:40-9-3(c)):
A late renewal fee attaches thirty (30) days after expiration (journeyman renewal $75, or $100 with the late fee).
A license may be renewed up to one (1) year from the original renewal date once CE is met. Any license that remains expired longer than one year shall not be renewed .
An individual with a canceled license cannot pay late fees to revive it; they must submit a brand new application, meet all current prerequisite requirements, and pass the complete state licensing examination again before working.
6. Municipal Registration & State Preemption
Candidates must understand the legal boundary between state licensing authority and municipal jurisdiction under 59 O.S. § 1693 :
State License Preemption: An Oklahoma state electrical license preempts local trade competency testing. No municipality, city, or county may require a state-licensed electrician to take a local electrical competency examination or prove trade qualifications beyond the state license.
Permitted Municipal Authority: Cities and incorporated towns are legally permitted to:
Establish local electrical inspection departments and appoint electrical inspectors.
Require state-licensed electrical contractors to register with the city prior to pulling permits.
Assess a reasonable, non-discriminatory annual municipal registration fee.
Require electrical permits and enforce local amendments to the building/electrical code (provided local codes meet or exceed state minimums).
Unlicensed Contracting in Municipalities: Performing electrical contracting without a state license inside an incorporated municipality violates both state statute and local ordinances, subjecting the violator to concurrent prosecution by the municipal court and the CIB Hearing Board.