Study guide

1.7 OSHA 29 CFR 1926 Job-Site Safety: Sanitation, Signage, Ladders, Scaffolds & Fall Protection

Oklahoma Journeyman Electrician Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Oklahoma Licensing Laws, Board Rules & Safety

1.1 Oklahoma Electrical License Act & CIB Regulations 1.2 OK Journeyman Exam Format, PSI Logistics & Codebook Navigation 1.3 OSHA Electrical Safety Standards (29 CFR 1926/1910) 1.4 NFPA 70E Electrical Safety in the Workplace & Arc Flash 1.5 Permits, Inspections, Structural Integrity & Job Estimating 1.6 Oklahoma's Adopted 2023 NEC: OUBCC Amendments You Must Know 1.7 OSHA 29 CFR 1926 Job-Site Safety: Sanitation, Signage, Ladders, Scaffolds & Fall Protection

2 Chapter 2: General Electrical Theory & Calculations

2.1 Ohm's Law, Watt's Law & DC Series/Parallel Circuits 2.2 AC Theory, Reactance, Impedance & Power Factor 2.3 Three-Phase Power Systems (Delta & Wye Configurations) 2.4 Electrical Units, Formulas & Conversions 2.5 Cost of Power in a Circuit, Efficiency & Troubleshooting/Test Instruments

3 Chapter 3: General Installation Requirements (NEC Article 110)

3.1 Examination, Identification, Installation & Use of Equipment (110.3) 3.2 Electrical Connections, Terminations & Torque Requirements (110.14) 3.3 Working Space, Clearances & Guarding of Live Parts (110.26 & 110.27) 3.4 Enclosure Types, Markings & Available Fault Current (110.24 & 110.28) 3.5 Installations Over 600 Volts: Article 110 Part III, Article 490 & Medium-Voltage Cable

4 Chapter 4: Branch Circuits & Feeders (NEC Articles 210, 215 & 225)

4.1 Branch Circuit Ratings, Multiwire Branch Circuits & Identification (210.3–210.10) 4.2 Ground-Fault Circuit-Interrupter (GFCI) Protection (210.8) 4.3 Arc-Fault Circuit-Interrupter (AFCI) Protection & Receptacle Outlets (210.12 & 210.52) 4.4 Outside Branch Circuits and Feeders (Article 225) & Feeder Sizing (Article 215)

5 Chapter 5: Services & Service Equipment (NEC Article 230)

5.1 Service Clearances, Overhead & Underground Service-Drop Requirements (230.9, 230.24 & 230.30) 5.2 Service-Entrance Conductors, Sizing & Installation (230.40–230.54) 5.3 Service Equipment Disconnecting Means, Overcurrent Protection & Emergency Disconnects (230.70–230.95)

6 Chapter 6: Electrical Load Calculations (NEC Article 220)

6.1 General Lighting, Small Appliance & Laundry Loads (NEC 220.41, 220.42, 220.45 & 220.52) 6.2 Standard Dwelling Unit Feeder & Service Calculations (NEC Article 220 Part III) 6.3 Optional Dwelling Unit Feeder & Service Calculations (NEC Article 220 Part IV) 6.4 Commercial & Multi-Family Load Calculations (Cooktops, Dryers, HVAC & Stores)

7 Chapter 7: Overcurrent Protection & Tap Rules (NEC Article 240)

7.1 Overcurrent Protection Fundamentals & Standard Ampere Ratings (240.4 & 240.6) 7.2 Feeder & Branch Circuit Tap Rules (NEC 240.21) 7.3 Ground-Fault Protection of Equipment & Selective Coordination (NEC 240.13, 240.86 & Article 245)

8 Chapter 8: Grounding and Bonding (NEC Article 250)

8.1 General Grounding Principles, System Grounding & Grounded Conductors (NEC 250.4, 250.20 & 250.24) 8.2 Grounding Electrode System & Grounding Electrode Conductor (GEC) Sizing (NEC 250.50, 250.52 & 250.66) 8.3 Equipment Grounding Conductors (EGC) Sizing & Installation (NEC 250.118, 250.120 & 250.122) 8.4 Bonding Requirements, Main/System Bonding Jumpers & Separately Derived Systems (NEC 250.28, 250.30 & 250.102)

9 Chapter 9: Wiring Methods & Materials (NEC Articles 300–314)

9.1 General Requirements for Wiring Methods, Underground Clearances & Firestopping (NEC Article 300) 9.2 Conductor Ampacity Ratings, Temperature Correction & Bundling Adjustments (Article 310 & Table 310.16) 9.3 Nonmetallic-Sheathed Cable (Type NM), Metal-Clad Cable (Type MC) & Armored Cable (Type AC) 9.4 Outlet, Device, Pull & Junction Boxes Sizing and Box Fill Calculations (NEC Article 314) 9.5 Temporary Installations (Article 590), Cranes & Hoists (Article 610), Elevators & Escalators (Article 620)

10 Chapter 10: Raceways, Tubing, Conduit Fill & Underground Systems

10.1 Rigid Metal Conduit (RMC), Intermediate Metal Conduit (IMC) & Electrical Metallic Tubing (EMT) 10.2 Nonmetallic Raceways (PVC, RTRC, Liquidtight) & Cable Trays (NEC Articles 352, 356, 392) 10.3 Conduit Fill Calculations (Chapter 9 Tables 1, 4 & 5, Annex C) & Pull Box Sizing (NEC 314.28)

11 Chapter 11: Motors, Controllers & Air Conditioning (NEC Articles 430 & 440)

11.1 Motor Full-Load Current (FLC), Branch Circuit Conductor Sizing & Disconnects (430.6, 430.22 & 430.102) 11.2 Motor Overload Protection & Motor Branch Circuit Short-Circuit/Ground-Fault Protection (430.32 & 430.52) 11.3 Motor Feeder Conductor Sizing & Feeder Overcurrent Protection (430.24 & 430.62) 11.4 Air Conditioning & Refrigeration Equipment (NEC Article 440: MCA, MOCP & Disconnects)

12 Chapter 12: Transformers & Equipment (NEC Articles 450, 410, 422 & 424)

12.1 Transformer Sizing, Protection & Voltage Calculations (NEC Article 450 & Table 450.3(B)) 12.2 Luminaires, Lampholders & Lamps Installation (NEC Article 410) 12.3 Appliances & Electric Water Heaters (NEC Article 422) 12.4 Fixed Electric Space-Heating Equipment (NEC Article 424) 12.5 Snow-Melting & De-Icing Equipment (Article 426) and Pipeline & Vessel Heating (Article 427) 12.6 Electric Signs & Outline Lighting (Article 600) and Lighting Systems 30 Volts or Less (Article 411)

13 Chapter 13: Special Occupancies & Hazardous Locations (NEC Articles 500–517)

13.1 Hazardous (Classified) Locations: Class I, II, and III (Articles 500, 501, 502 & 503) 13.2 Commercial Garages, Repair Facilities & Fuel Dispensing Facilities (Articles 511 & 514) 13.3 Health Care Facilities: Patient Care Spaces & Wiring Methods (Article 517) 13.4 Agricultural Buildings & Manufactured/Mobile Homes (Articles 547 & 550) 13.5 Bulk Storage Plants (Article 515) and Spray Application, Dipping & Coating (Article 516)

14 Chapter 14: Special Equipment, Swimming Pools & Low-Voltage Systems

14.1 Swimming Pools, Spas, Hot Tubs & Hydromassage Bathtubs (Article 680) 14.2 Emergency Systems, Legally Required & Optional Standby Systems (Articles 700, 701 & 702) 14.3 Class 1, 2, 3 & Class 4 Power-Limited Circuits (NEC Articles 722, 724, 725 & 726) and Fire Alarms (NEC Article 760) 14.4 RV Parks (Article 551), Floating Buildings (Article 553) & Marinas/Docking Facilities (Article 555)

1.7 OSHA 29 CFR 1926 Job-Site Safety: Sanitation, Signage, Ladders, Scaffolds & Fall Protection

Key Takeaways Explain This Topic AI

PSI lists 29 CFR Part 1926 as a permitted open-book reference and allocates 4 scored items to Safety, whose sub-topics are general construction safety — sanitation, first aid, PPE, excavation, ladders, scaffolds, illumination, signage, material handling, SDS, and fall protection.

29 CFR 1926.501 sets the construction fall-protection trigger at 6 feet, and 1926.502 caps arresting force on a body harness at 1,800 pounds with free fall limited to 6 feet and deceleration distance to 3.5 feet.

Ladder side rails must extend at least 3 feet above the upper landing surface, and a portable ladder is pitched at roughly 4 to 1 — one foot of base offset for every four feet of working length (29 CFR 1926.1053).

Scaffolds must support their own weight plus at least 4 times the maximum intended load, and guardrails are required on scaffold platforms more than 10 feet above a lower level (29 CFR 1926.451).

Trenches and excavations 5 feet or deeper require a protective system unless made entirely in stable rock, spoil must be kept at least 2 feet from the edge, and a means of egress must be within 25 feet of lateral travel in trenches 4 feet or deeper (29 CFR 1926.651 and .652).

Last updated: August 2026

1.7 OSHA 29 CFR 1926 Job-Site Safety: Sanitation, Signage, Ladders, Scaffolds & Fall Protection

Section 1.3 covered the electrical half of job-site safety — energized work, lockout/tagout, GFCI versus an assured equipment grounding conductor program, and insulating rubber goods. The PSI Safety subject area is broader than that. Its eighteen listed sub-topics are ordinary construction-safety topics: job site sanitation, responsibility for providing PPE, excavation safety, emergency action plans, safety training, ventilation, first aid kit requirements, use of PPE, signs/signals/barricades, tools and equipment, ladders, workplace illumination, scaffolds, work around toxic materials, material cleanup and disposal, safety data sheets, handling and storing materials, and fall protection.

This is also the one subject area where the reference book does most of the work for you: 29 CFR Part 1926 is on the permitted reference list , so tab it before test day.

1. Sanitation, First Aid, and Emergency Planning

Requirement Standard The number that gets tested

Potable water 1926.51(a) Provided on every job; a common drinking cup is prohibited; single-use cups with a sanitary container and a waste receptacle

Non-potable water 1926.51(b) Outlets must be clearly marked as unfit for drinking, washing, or cooking

Toilets 1926.51(c) Required by employee count: 1 facility for 20 or fewer employees; 1 toilet seat and 1 urinal per 40 workers for 20–200; 1 toilet seat and 1 urinal per 50 workers above 200

Washing facilities 1926.51(f) Required near work involving harmful substances so employees can remove them at the end of the shift

First aid 1926.50 Medical personnel available for consultation; where no infirmary, clinic, or hospital is reasonably accessible, a person trained in first aid must be on site; first-aid supplies must be easily accessible and weatherproof

Emergency action plan 1926.35 Written (may be oral for 10 or fewer employees); must cover escape routes, critical-operations shutdown, employee accounting, rescue and medical duties, reporting, and the persons to contact; employees must be trained on it

Safety training 1926.21(b)(2) The employer must instruct each employee in the recognition and avoidance of unsafe conditions and in the regulations applicable to the hazards on that job

Ventilation 1926.57 Local exhaust or mechanical ventilation is required where dusts, fumes, mists, vapors, or gases threaten exposure limits — the go-to rule for cutting, welding, and solvent work in confined areas

Important

PPE is the employer’s cost. 29 CFR 1926.95(d) requires the employer to provide required PPE at no cost to the employee , with narrow exceptions such as non-specialty safety-toe footwear and non-specialty prescription safety eyewear that the employee is allowed to take off-site. "Buy your own hard hat" is not a lawful job-site policy.

2. Signs, Signals, Barricades, and Illumination

Subpart G (1926.200–.203) standardizes the color language of a job site:

Danger signs — red, black, and white. Used only where an immediate hazard exists.

Caution signs — yellow with a black panel. Warn against potential hazards or unsafe practices.

Warning signs — orange. Hazards between "caution" and "danger."

Safety instruction signs — white with a green panel. General safety information.

Directional and exit signs must be visible at all times where an exit is required.

Flaggers must use STOP/SLOW paddles, red flags, or approved lights and must wear high-visibility warning garments; at night the garment must be retroreflective.

Barricades for protection of workers must conform to the Manual on Uniform Traffic Control Devices where public traffic is involved.

Illumination is set by 1926.56 Table D-3, and the exam favors the two extremes:

  • Area Minimum illumination
  • General construction area lighting 5 foot-candles

General construction areas, concrete placement, excavation and waste areas, access ways, active storage areas, loading platforms, refueling, field maintenance 3 foot-candles

Indoors: warehouses, corridors, hallways, exitways 5 foot-candles

Tunnels, shafts, and general underground work areas 5 foot-candles (10 at the tunnel and shaft heading during drilling, mucking, and scaling)

  • General construction plant and shops 10 foot-candles
  • First-aid stations, infirmaries, and offices 30 foot-candles
  • 3. Tools, Ladders, and Scaffolds

Hand and power tools (1926.300–.305). All hand and power tools, whether furnished by the employer or the employee, must be maintained in safe condition. Guards on point-of-operation and rotating parts may never be removed while the tool is in use. Electric power tools must be grounded through a three-conductor cord or be listed double insulated ; pneumatic tool hose connections above 40 psi require a safety device at the source of supply to prevent whipping.

Ladders (1926.1053). The most-tested ladder numbers are:

Side rails of a ladder used for access to an upper landing must extend at least 3 feet (0.9 m) above the landing surface, unless a grab rail is provided.

Non-self-supporting portable ladders are set at a pitch of about 4 to 1 — the base is one foot out for every four feet of working length.

Ladders may not be tied together to create longer sections unless designed for it, and rungs must be kept free of oil, grease, and wet paint.

Portable metal or conductive ladders may not be used where the employee or the ladder could contact energized conductors.

Employees must be trained by a competent person (1926.1060) on ladder hazards, maximum intended load, and proper erection.

Scaffolds (1926.451). Every scaffold and its components must support its own weight plus at least 4 times the maximum intended load . Platforms must be fully planked, and each platform must be at least 18 inches wide except in specific narrow-work situations. Guardrail systems are required on scaffold platforms more than 10 feet above a lower level , with the top rail between 38 and 45 inches for scaffolds erected under the current rule. A competent person must supervise erection, moving, dismantling, and altering, and must inspect the scaffold before each work shift. Training is required by 1926.454.

4. Materials, Toxic Substances, and Housekeeping

Handling and storing materials (1926.250). Maximum safe load limits must be posted in storage areas of buildings under construction, and aisles and passageways must be kept clear. The stacking limits are exam favorites:

Brick may not be stacked more than 7 feet high; a loose brick stack must be tapered back 2 inches in every foot above the 4-foot level.

Masonry blocks stacked higher than 6 feet must be tapered back one-half block per tier above the 6-foot level.

Lumber piles may not exceed 20 feet when handled by a forklift, or 16 feet when handled manually, and must be stacked on level, solidly supported sills with nails withdrawn.

Housekeeping and disposal (1926.25). Form and scrap lumber with protruding nails must be kept clear of work areas, passageways, and stairs; combustible scrap and debris must be removed at regular intervals; and containers must be provided for collection of oily or flammable waste.

Toxic materials. 1926.55 controls exposure to gases, vapors, fumes, dusts, and mists, requiring administrative or engineering controls first and PPE only where those are not feasible. Specific expanded standards apply to lead (1926.62) , asbestos (1926.1101) , and respirable crystalline silica (1926.1153) — the last of which reaches electricians directly whenever concrete is cored, chased, or sawed.

Hazard communication and SDS. 1926.59 adopts 29 CFR 1910.1200 for construction. The employer must maintain a written hazard communication program, keep a chemical inventory, ensure containers are labeled, make safety data sheets readily accessible on the job site, and train employees. SDSs follow a standardized 16-section format; Sections 1–8 (identification, hazards, composition, first aid, firefighting, accidental release, handling and storage, exposure controls) carry the information a crew needs during an incident.

5. Excavation and Fall Protection

Excavations (Subpart P, 1926.650–.652).

A protective system — sloping, benching, shoring, or shielding — is required for excavations 5 feet or deeper unless the excavation is made entirely in stable rock.

Excavations deeper than 20 feet require a protective system designed by a registered professional engineer .

Spoil piles and equipment must be kept at least 2 feet back from the edge.

In trenches 4 feet or deeper , a stairway, ladder, or ramp must be within 25 feet of lateral travel .

A competent person must inspect the excavation daily, before each shift, and after every rainstorm.

Maximum allowable slopes for a simple sloped excavation less than 20 feet deep: Type A soil ¾:1 (53°), Type B soil 1:1 (45°), Type C soil 1½:1 (34°) .

Fall protection (Subpart M, 1926.501 and .502).

Construction fall protection is triggered at 6 feet above a lower level — guardrails, safety nets, or a personal fall arrest system.

Guardrails: top rail 42 inches ±3 inches , midrail at about 21 inches , and a 3½-inch toeboard where objects could fall on people below. The top rail must withstand a 200-pound force.

Personal fall arrest systems: must limit arresting force to 1,800 pounds when used with a body harness, limit free fall to 6 feet or less , bring the worker to a complete stop within a 3.5-foot deceleration distance, and be anchored to a point capable of supporting 5,000 pounds per attached employee (or designed with a safety factor of at least two under a qualified person’s supervision).

Body belts are prohibited as part of a personal fall arrest system.

Holes , including skylights, must be guarded by covers, guardrails, or personal fall arrest systems; covers must support at least twice the weight of employees, equipment, and materials that may cross them and must be marked "HOLE" or "COVER."